[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-392-11":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":560},{"id":5,"name":6,"category":7,"favorite":8},392,"继电保护","特种作业",0,11,50,1668,[13,31,41,51,64,74,84,96,108,120,130,140,148,160,170,180,190,202,214,226,236,246,258,270,280,290,300,310,320,332,342,354,366,376,386,398,410,422,432,444,454,464,476,486,498,508,520,530,540,550],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":30},716866,1,"单选题","电力系统继电保护由测量部分、逻辑部分和()构成。",[19,23,26],{"key":20,"text":21,"correct":22},"A",".显示部分",false,{"key":24,"text":25,"correct":22},"B",".判断部分",{"key":27,"text":28,"correct":29},"C",".执行部分",true,"",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":24,"analysis":30},716867,"电动机纵差动保护接线时,机端电流互感器与中性点侧电流互感器()。",[35,37,39],{"key":20,"text":36,"correct":22},".型号相同,变比不同",{"key":24,"text":38,"correct":29},".型号相同,变比相同",{"key":27,"text":40,"correct":22},".型号不同,变比相同",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":24,"analysis":30},716868,"二次系统中,由直流电源和供电网络构成,实现供给二次系统工作电源的系统称为()。",[45,47,49],{"key":20,"text":46,"correct":22},".信号系统",{"key":24,"text":48,"correct":29},".操作电源系统",{"key":27,"text":50,"correct":22},".调节系统",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":24,"analysis":30},716869,"微机保护对模数变换系统采样数据进行分析、计算和判断,实现各种继电保护功能的方法称为()。",[55,57,59,61],{"key":20,"text":56,"correct":22},".动作特性",{"key":24,"text":58,"correct":29},".算法",{"key":27,"text":60,"correct":22},".数据中断",{"key":62,"text":63,"correct":22},"D",".数据采集",{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":24,"analysis":30},716870,"整定限时电流速断保护动作电流时,可靠系数取()。",[68,70,72],{"key":20,"text":69,"correct":22},"0.5-1.0",{"key":24,"text":71,"correct":29},"1.1-1.2",{"key":27,"text":73,"correct":22},"1.0",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":24,"analysis":30},716871,"自动重合闸装置按照重合闸的动作次数可分为()和二次(多次)重合闸。",[78,80,82],{"key":20,"text":79,"correct":22},".单相重合闸",{"key":24,"text":81,"correct":29},".一次重合闸",{"key":27,"text":83,"correct":22},".三相重合闸",{"id":85,"libraryId":5,"type":15,"typeLabel":16,"stem":86,"options":87,"answer":27,"analysis":30},716872,"根据变压器励磁涌流特点,当保护鉴别不是励磁涌流时须()。",[88,90,92,94],{"key":20,"text":89,"correct":22},".起动合闸",{"key":24,"text":91,"correct":22},".闭锁保护",{"key":27,"text":93,"correct":29},".开放保护",{"key":62,"text":95,"correct":22},".发闭锁信号",{"id":97,"libraryId":5,"type":15,"typeLabel":16,"stem":98,"options":99,"answer":62,"analysis":30},716873,"变压器内部发生严重故障时,油箱内产生大量气体,使瓦斯继电器动作,则()。",[100,102,104,106],{"key":20,"text":101,"correct":22},".发出轻瓦斯信号",{"key":24,"text":103,"correct":22},".发出过负荷信号",{"key":27,"text":105,"correct":22},".发出过电流信号",{"key":62,"text":107,"correct":29},".保护跳闸,断开变压器各侧断路器",{"id":109,"libraryId":5,"type":15,"typeLabel":16,"stem":110,"options":111,"answer":62,"analysis":30},716874,"备用电源自动投入装置动作时,通过合()断路器或备用变压器断路器实现备用电源的投入。",[112,114,116,118],{"key":20,"text":113,"correct":22},".工作线路",{"key":24,"text":115,"correct":22},".工作母线",{"key":27,"text":117,"correct":22},".工作变压器",{"key":62,"text":119,"correct":29},".备用线路",{"id":121,"libraryId":5,"type":15,"typeLabel":16,"stem":122,"options":123,"answer":27,"analysis":30},716875,"微机保护具有信号测量、()、出口执行等布线逻辑保护的功能。",[124,126,128],{"key":20,"text":125,"correct":22},".模数变换",{"key":24,"text":127,"correct":22},".人机接口",{"key":27,"text":129,"correct":29},".逻辑判断",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":27,"analysis":30},716876,"继电保护连接片(或称为压板)用于()。",[134,136,138],{"key":20,"text":135,"correct":22},".增加触点容量",{"key":24,"text":137,"correct":22},".增大保护固有动作时间",{"key":27,"text":139,"correct":29},".投入\u002F退出保护,接通\u002F断开保护出口",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":20,"analysis":30},716877,"电动机纵差动保护接线电流互感器二次回路发生断线时应()。",[144,145,146],{"key":20,"text":91,"correct":29},{"key":24,"text":93,"correct":22},{"key":27,"text":147,"correct":22},".直接跳闸",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":24,"analysis":30},716878,"线路纵差保护在线路区外短路()。",[152,154,156,158],{"key":20,"text":153,"correct":22},".保护迅速动作",{"key":24,"text":155,"correct":29},".保护不动作",{"key":27,"text":157,"correct":22},".保护延时动作",{"key":62,"text":159,"correct":22},".须等待相邻保护拒动时再动作",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":24,"analysis":30},716879,"电动机运行时,电压互感器一次或二次发生断线时,低电压保护()。",[164,166,168],{"key":20,"text":165,"correct":22},".经延时跳闸",{"key":24,"text":167,"correct":29},".不应动作",{"key":27,"text":169,"correct":22},".瞬时跳闸",{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":24,"analysis":30},716880,"电动机负序电流保护动作时限特性,可以根据需要选择定时限特性或()。",[174,176,178],{"key":20,"text":175,"correct":22},".长延时特性",{"key":24,"text":177,"correct":29},".反时限特性",{"key":27,"text":179,"correct":22},".短延时特性",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":24,"analysis":30},716881,"电力系统出现振荡属于()。",[184,186,188],{"key":20,"text":185,"correct":22},".故障状态",{"key":24,"text":187,"correct":29},".异常运行状态",{"key":27,"text":189,"correct":22},".正常运行状态",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":20,"analysis":30},716882,"变压器内部发生轻微故障,产生少量气体流向油枕,使重瓦斯继电器动作,发出()。",[194,196,198,200],{"key":20,"text":195,"correct":29},".轻瓦斯信号",{"key":24,"text":197,"correct":22},".重瓦斯信号",{"key":27,"text":199,"correct":22},".保护跳闸信号",{"key":62,"text":201,"correct":22},".过负荷信号",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":27,"analysis":30},716883,"某企业的电动机装设过热保护,在运行中由于过负荷产生过热,当积累热量达到过热积累告警定值时保护将起动()。",[206,208,210,212],{"key":20,"text":207,"correct":22},".过热闭锁",{"key":24,"text":209,"correct":22},".过热跳闸",{"key":27,"text":211,"correct":29},".过热告警",{"key":62,"text":213,"correct":22},".过热禁止再起动",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":20,"analysis":30},716884,"对于容量在()且电流速断保护灵敏度不满足要求的变压器应装设纵差动保护。",[218,220,222,224],{"key":20,"text":219,"correct":29},".2000kV以上",{"key":24,"text":221,"correct":22},".6300kV以上",{"key":27,"text":223,"correct":22},".800kV及以上",{"key":62,"text":225,"correct":22},".400kV及以上",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":27,"analysis":30},716885,"上下级定时限过电流保护按照选择性要求,其动作时间应为()。",[230,232,234],{"key":20,"text":231,"correct":22},".上下级整定值相等",{"key":24,"text":233,"correct":22},".下条线路定时限过电流保护整定值大",{"key":27,"text":235,"correct":29},".本线路定时限过电流保护整定值大",{"id":237,"libraryId":5,"type":15,"typeLabel":16,"stem":238,"options":239,"answer":20,"analysis":30},716886,"对()的变压器,可以装设单独的电流速断保护,与气体保护配合构成变压器的主保护。",[240,242,244],{"key":20,"text":241,"correct":29},".中、小容量",{"key":24,"text":243,"correct":22},".大容量",{"key":27,"text":245,"correct":22},".超大容量",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":24,"analysis":30},716887,"断路器控制方式中,按照控制断路器数量的不同可分为()和一对N控制。",[250,252,254,256],{"key":20,"text":251,"correct":22},".一对二控制",{"key":24,"text":253,"correct":29},".一对一控制",{"key":27,"text":255,"correct":22},".一对三控制",{"key":62,"text":257,"correct":22},".一对四控制",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":20,"analysis":30},716888,"变压器气体保护包括重瓦斯保护和()。",[262,264,266,268],{"key":20,"text":263,"correct":29},".轻瓦斯保护",{"key":24,"text":265,"correct":22},".过负荷保护",{"key":27,"text":267,"correct":22},".零序电流保护",{"key":62,"text":269,"correct":22},".速断电流保护",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":27,"analysis":30},716889,"变压器内部故障时在变压器差动保护中,流入差回路的电流为变压器两侧电流的()。",[274,276,278],{"key":20,"text":275,"correct":22},".功率和",{"key":24,"text":277,"correct":22},".相角和",{"key":27,"text":279,"correct":29},".相量和",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":27,"analysis":30},716890,"电力系统是由发电厂、变电所、送电线路、配电线路、()组成的整体。",[284,286,288],{"key":20,"text":285,"correct":22},".变压器",{"key":24,"text":287,"correct":22},".断路器",{"key":27,"text":289,"correct":29},".电力用户",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":27,"analysis":30},716891,"当通过电流继电器的电流小于返回电流时,继电器返回,动合触点()。",[294,296,298],{"key":20,"text":295,"correct":22},".闭合",{"key":24,"text":297,"correct":22},".任意位置",{"key":27,"text":299,"correct":29},".断开",{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":20,"analysis":30},716892,"三段式零序电流保护加装()元件后,构成三段式零序方向电流保护。",[304,306,308],{"key":20,"text":305,"correct":29},".零序功率方向",{"key":24,"text":307,"correct":22},".正序功率方向",{"key":27,"text":309,"correct":22},".低电压",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":27,"analysis":30},716893,"当电流互感器以一次电流从某端流入,二次电流从按减极性原则标注规定正方向的同名端流出时,则电流互感器一次、二次电流相位()。",[314,316,318],{"key":20,"text":315,"correct":22},".与交、直流有关",{"key":24,"text":317,"correct":22},".相反",{"key":27,"text":319,"correct":29},".相同",{"id":321,"libraryId":5,"type":15,"typeLabel":16,"stem":322,"options":323,"answer":27,"analysis":30},716894,"我国变电站一次主接线备用电源自动投入的主要一次接线方案有:低压母线分段备自投接线、()及进线备自投接线等。",[324,326,328,330],{"key":20,"text":325,"correct":22},".暗备用自投",{"key":24,"text":327,"correct":22},".明备用自投",{"key":27,"text":329,"correct":29},".变压器备自投接线",{"key":62,"text":331,"correct":22},".无功备用自投",{"id":333,"libraryId":5,"type":15,"typeLabel":16,"stem":334,"options":335,"answer":27,"analysis":30},716895,"高压电动机运行常见的异常运行状态有:起动时间过长、()或三相不平衡、堵转、过负荷引起的过电流、供电电压过低或过高。",[336,338,340],{"key":20,"text":337,"correct":22},".一相绕组的匝间短路",{"key":24,"text":339,"correct":22},".定子绕组的相间短路故障",{"key":27,"text":341,"correct":29},".一相熔断器熔断",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":62,"analysis":30},716896,"变压器油箱外故障包括套管破碎通过外壳发生的单相接地故障、引出线的套管闪络故障及()等。",[346,348,350,352],{"key":20,"text":347,"correct":22},".绕组间的相间故障",{"key":24,"text":349,"correct":22},".一相绕组匝间短路",{"key":27,"text":351,"correct":22},".绕组与铁芯之间的单相接地故障",{"key":62,"text":353,"correct":29},".出线上的相间故障",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":62,"analysis":30},716897,"电流互感器二次应该装有一个(),以防止互感器一、二次绕组绝缘击穿时危及设备和人身安全。",[358,360,362,364],{"key":20,"text":359,"correct":22},".继电保护",{"key":24,"text":361,"correct":22},".熔断器",{"key":27,"text":363,"correct":22},".安全防护罩",{"key":62,"text":365,"correct":29},".保安接地点",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":20,"analysis":30},716898,"当电动机供电网络电压降低后恢复,电动机自起动时起动电流()额定电流。",[370,372,374],{"key":20,"text":371,"correct":29},".大于",{"key":24,"text":373,"correct":22},".小于",{"key":27,"text":375,"correct":22},".等于",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":20,"analysis":30},716899,"能够使低电压继电器开始动作的()称为低电压继电器的动作电压。",[380,382,384],{"key":20,"text":381,"correct":29},".最大电压",{"key":24,"text":383,"correct":22},".最小电压",{"key":27,"text":385,"correct":22},".任意电压",{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":20,"analysis":30},716900,"电动机堵转保护采用()构成。",[390,392,394,396],{"key":20,"text":391,"correct":29},".定时限动作特性",{"key":24,"text":393,"correct":22},".反时限动作特性",{"key":27,"text":395,"correct":22},".长延时动作特性",{"key":62,"text":397,"correct":22},".短延时动作特性",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":24,"analysis":30},716901,"距离保护装置所测量的阻抗与保护安装处至短路点的()成正比。",[402,404,406,408],{"key":20,"text":403,"correct":22},".电压",{"key":24,"text":405,"correct":29},".距离",{"key":27,"text":407,"correct":22},".电流",{"key":62,"text":409,"correct":22},".电压差",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":24,"analysis":30},716902,"瞬时电流速断保护反应线路故障电流增大时动作,动作延时()。",[414,416,418,420],{"key":20,"text":415,"correct":22},".2秒",{"key":24,"text":417,"correct":29},".0秒",{"key":27,"text":419,"correct":22},".0.5秒",{"key":62,"text":421,"correct":22},".1秒",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":20,"analysis":30},716903,"电动机起动时间过长保护动作于()。",[426,428,430],{"key":20,"text":427,"correct":29},".跳闸",{"key":24,"text":429,"correct":22},".信号",{"key":27,"text":431,"correct":22},".减负荷",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":27,"analysis":30},716904,"造成变压器差动保护不平衡电流的因素有()、两侧电流互感器二次阻抗不完全匹配、变压器分接头调整等。",[436,438,440,442],{"key":20,"text":437,"correct":22},".电压互感器的影响",{"key":24,"text":439,"correct":22},".保护定值偏高",{"key":27,"text":441,"correct":29},".电流互感器变比标准化",{"key":62,"text":443,"correct":22},".差动继电器动作电流偏小",{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":24,"analysis":30},716905,"电动机纵差动保护接线采用比率制动特性,应保证躲过电动机全电压起动时、外部三相短路电动机向外供给短路电流时以及()差动回路的不平衡电流。",[448,450,452],{"key":20,"text":449,"correct":22},".内部两相短路时",{"key":24,"text":451,"correct":29},".正常运行时",{"key":27,"text":453,"correct":22},".内部三相短路时",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":27,"analysis":30},716906,"对单侧有电源的辐射形电网,电流保护装设在线路的()。",[458,460,462],{"key":20,"text":459,"correct":22},".中间",{"key":24,"text":461,"correct":22},".末端",{"key":27,"text":463,"correct":29},".始端",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":20,"analysis":30},716907,"变压器差动保护灵敏度校验按照保护范围内()校验。",[468,470,472,474],{"key":20,"text":469,"correct":29},".最小短路电流",{"key":24,"text":471,"correct":22},".最大短路电流",{"key":27,"text":473,"correct":22},".最大不平衡电流",{"key":62,"text":475,"correct":22},".最大负荷电流",{"id":477,"libraryId":5,"type":15,"typeLabel":16,"stem":478,"options":479,"answer":24,"analysis":30},716908,"变压器低电压起动的过电流保护的电压元件动作电压整定,按照躲过()。",[480,482,484],{"key":20,"text":481,"correct":22},".正常运行母线可能出现的最低工作电压",{"key":24,"text":483,"correct":29},".额定电压",{"key":27,"text":485,"correct":22},".最大工作电压",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":62,"analysis":30},716909,"某变电站断路器、隔离开关采用闭锁控制回路,在进行隔离开关及断路器操作时时,其逻辑关系应为()。",[490,492,494,496],{"key":20,"text":491,"correct":22},".断路器、隔离开关可同时进行操作",{"key":24,"text":493,"correct":22},".断路器合闸时,才能操作隔离开关",{"key":27,"text":495,"correct":22},".无论断路器处于合闸或分闸,均可操作隔离开关",{"key":62,"text":497,"correct":29},".断路器处于分闸时,才能操作隔离开关",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":20,"analysis":30},716910,"变压器低电压起动的过电流保护的电压元件接在降压变压器()母线电压互感器二次侧线电压,反应三相线电压降低时动作。",[502,504,506],{"key":20,"text":503,"correct":29},".低压侧",{"key":24,"text":505,"correct":22},".高压侧",{"key":27,"text":507,"correct":22},".高压侧或低压侧",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":24,"analysis":30},716911,"对一次电力系统的发电、输配电以及用电的全过程进行监视、控制、调节调度,以及必要的保护等作用的设备称为()。",[512,514,516,518],{"key":20,"text":513,"correct":22},".高压设备",{"key":24,"text":515,"correct":29},".一次设备",{"key":27,"text":517,"correct":22},".低压设备",{"key":62,"text":519,"correct":22},".二次设备",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":27,"analysis":30},716912,"电流继电器的返回电流与动作电流之比称为电流继电器的()。",[524,526,528],{"key":20,"text":525,"correct":22},".灵敏系数",{"key":24,"text":527,"correct":22},".可靠系数",{"key":27,"text":529,"correct":29},".返回系数",{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":20,"analysis":30},716913,"当电动机供电网络电压降低时,电动机转速会()。",[534,536,538],{"key":20,"text":535,"correct":29},".下降",{"key":24,"text":537,"correct":22},".升高",{"key":27,"text":539,"correct":22},".不变",{"id":541,"libraryId":5,"type":15,"typeLabel":16,"stem":542,"options":543,"answer":24,"analysis":30},716914,"零序电流I段动作电流的整定为()。",[544,546,548],{"key":20,"text":545,"correct":22},".躲过本线路末端短路可能出现的最大短路电流",{"key":24,"text":547,"correct":29},".躲过本线路末端接地短路流过保护的最大零序电流",{"key":27,"text":549,"correct":22},".躲过下级线路末端接地短路流过保护的最大零序电流",{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":20,"analysis":30},716915,"对单侧有电源的辐射形电网,当短路点距离系统电源越近,短路电流()。",[554,556,558],{"key":20,"text":555,"correct":29},".越大",{"key":24,"text":557,"correct":22},".越小",{"key":27,"text":559,"correct":22},".无论远近均相等",[561,564,567,569,572,575],{"id":562,"name":563,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":565,"name":566,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":568,"name":566,"category":7,"favorite":8},336,{"id":570,"name":571,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":573,"name":574,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":576,"name":577,"category":7,"favorite":8},353,"(N1)叉车司机"]