[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-392-10":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":545},{"id":5,"name":6,"category":7,"favorite":8},392,"继电保护","特种作业",0,10,50,1668,[13,31,44,54,64,76,86,98,108,118,130,142,152,162,172,182,192,204,214,224,234,244,253,263,271,281,291,301,311,323,333,345,353,363,374,384,394,404,414,424,436,448,460,470,480,492,502,514,525,535],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":30},716816,1,"单选题","电气安全管理人员应具备必要的()知识,并要根据实际情况制定安全措施,有计划地组织安全管理生产。",[19,23,27],{"key":20,"text":21,"correct":22},"A","组织管理",false,{"key":24,"text":25,"correct":26},"B","电气安全",true,{"key":28,"text":29,"correct":22},"C","电气基础","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":20,"analysis":30},716817,"自动重合闸按照()的原理起动。",[35,37,39,41],{"key":20,"text":36,"correct":26},".控制开关位置与断路器位置不对应",{"key":24,"text":38,"correct":22},".辅助接点与断路器位置不对应",{"key":28,"text":40,"correct":22},".备用电源与工作电源电压不相等",{"key":42,"text":43,"correct":22},"D",".故障线路与正常线路电压不相等",{"id":45,"libraryId":5,"type":15,"typeLabel":16,"stem":46,"options":47,"answer":20,"analysis":30},716818,"电动机容量在()时,纵差动保护采用两相式接线。",[48,50,52],{"key":20,"text":49,"correct":26},".5MW以下",{"key":24,"text":51,"correct":22},".2MW及以上",{"key":28,"text":53,"correct":22},".2MW以下",{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":20,"analysis":30},716819,"变压器低电压起动的过电流保护的灵敏度比定时限过电流保护的灵敏度()。",[58,60,62],{"key":20,"text":59,"correct":26},".高",{"key":24,"text":61,"correct":22},".低",{"key":28,"text":63,"correct":22},".不变",{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":20,"analysis":30},716820,"备用电源自动投入装置工作时,当工作母线失压时,自投装置应()。",[68,70,72,74],{"key":20,"text":69,"correct":26},".正确动作",{"key":24,"text":71,"correct":22},".不动作,发出异常信号",{"key":28,"text":73,"correct":22},".不动作",{"key":42,"text":75,"correct":22},".拒绝动作",{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":20,"analysis":30},716821,"电流互感器二次回路不能装设熔断器,不设置切换回路,防止电流互感器()。",[80,82,84],{"key":20,"text":81,"correct":26},".二次回路开路",{"key":24,"text":83,"correct":22},".一、二次绕组绝缘击穿",{"key":28,"text":85,"correct":22},".二次电流过大",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":20,"analysis":30},716822,"变压器瓦斯保护接线中切换片XB切换到试验位置,在变压器内部发生严重故障瓦斯保护动作时()。",[90,92,94,96],{"key":20,"text":91,"correct":26},".只发信号,不跳闸",{"key":24,"text":93,"correct":22},".只将低压侧断路器切除",{"key":28,"text":95,"correct":22},".只将高压侧断路器切除",{"key":42,"text":97,"correct":22},".断开变压器各侧断路器",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":28,"analysis":30},716823,"对双绕组变压器,过负荷保护装在()。",[102,104,106],{"key":20,"text":103,"correct":22},".电源侧或负荷侧",{"key":24,"text":105,"correct":22},".负荷侧",{"key":28,"text":107,"correct":26},".电源侧",{"id":109,"libraryId":5,"type":15,"typeLabel":16,"stem":110,"options":111,"answer":24,"analysis":30},716824,"中性点不接地系统发生单相接地故障,非故障线路零序电流方向为()。",[112,114,116],{"key":20,"text":113,"correct":22},".由线路流向母线",{"key":24,"text":115,"correct":26},".由母线流向线路",{"key":28,"text":117,"correct":22},".不确定",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":20,"analysis":30},716825,"变压器正常运行时励磁电流一般约为变压器额定电流的()。",[122,124,126,128],{"key":20,"text":123,"correct":26},"3%-5%",{"key":24,"text":125,"correct":22},"6-8倍",{"key":28,"text":127,"correct":22},"3-5倍",{"key":42,"text":129,"correct":22},"10%-15%",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":20,"analysis":30},716826,"将交流一次侧大电流转换成可供测量、保护等二次设备使用的二次侧电流的变流设备称为()。",[134,136,138,140],{"key":20,"text":135,"correct":26},".电流互感器",{"key":24,"text":137,"correct":22},".电压互感器",{"key":28,"text":139,"correct":22},".电流表",{"key":42,"text":141,"correct":22},".电压表",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":20,"analysis":30},716827,"瞬时电流速断保护对线路范围的保护是通过对()的合理整定来保证选择性的。",[146,148,150],{"key":20,"text":147,"correct":26},".动作电流",{"key":24,"text":149,"correct":22},".返回电流",{"key":28,"text":151,"correct":22},".动作电压",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":20,"analysis":30},716828,"变压器纵差动保护或电流速断保护动作后()。",[156,158,160],{"key":20,"text":157,"correct":26},".跳开变压器各侧断路器",{"key":24,"text":159,"correct":22},".给出异常信号",{"key":28,"text":161,"correct":22},".给出轻瓦斯信号",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":24,"analysis":30},716829,"既能关合、承载、开断运行回路的负荷电流,并能关合、承载短路等异常电流,但不能开断短路故障电流的开关设备为()。",[166,168,170],{"key":20,"text":167,"correct":22},"变压器",{"key":24,"text":169,"correct":26},"负荷开关",{"key":28,"text":171,"correct":22},"断路器",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":20,"analysis":30},716830,"继电保护装置中过电压继电器反应()而动作。",[176,178,180],{"key":20,"text":177,"correct":26},".电压增大",{"key":24,"text":179,"correct":22},".电流减小",{"key":28,"text":181,"correct":22},".电流增大",{"id":183,"libraryId":5,"type":15,"typeLabel":16,"stem":184,"options":185,"answer":28,"analysis":30},716831,"低压母线分段备自投接线的动作过程描述为()。",[186,188,190],{"key":20,"text":187,"correct":22},".主供电源失电,跳开备用电源断路器,在确认跳闸并判断备用电源正常运行时闭合分段断路器",{"key":24,"text":189,"correct":22},".主供电源失电,跳开主供电源断路器,延时后闭合主供电源断路器",{"key":28,"text":191,"correct":26},".主供电源失电,跳开主供电源断路器,在确认跳闸并判断备用电源正常运行时闭合分段断路器",{"id":193,"libraryId":5,"type":15,"typeLabel":16,"stem":194,"options":195,"answer":24,"analysis":30},716832,"对于容量在10000kVA以下的变压器,当过电流保护动作时间大于()时,应装设纵差动保护。",[196,198,200,202],{"key":20,"text":197,"correct":22},".2.5S",{"key":24,"text":199,"correct":26},".0.5S",{"key":28,"text":201,"correct":22},".1S",{"key":42,"text":203,"correct":22},".1.5S",{"id":205,"libraryId":5,"type":15,"typeLabel":16,"stem":206,"options":207,"answer":20,"analysis":30},716833,"当变压器发生内部严重故障时,引起电流互感器饱和,二次电流波形发生畸变,变压器差动速断元件将()。",[208,210,212],{"key":20,"text":209,"correct":26},".可靠动作",{"key":24,"text":211,"correct":22},".可靠制动",{"key":28,"text":213,"correct":22},".发出异常信号",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":28,"analysis":30},716834,"中性点直接接地系统发生接地故障,在三相中将产生大小相等、相位相同的()。",[218,220,222],{"key":20,"text":219,"correct":22},".负序电压、负序电流",{"key":24,"text":221,"correct":22},".正序电压、正序电流",{"key":28,"text":223,"correct":26},".零序电压、零序电流",{"id":225,"libraryId":5,"type":15,"typeLabel":16,"stem":226,"options":227,"answer":24,"analysis":30},716835,"中性点不接地系统发生单相接地故障,非故障线路零序电流()。",[228,230,232],{"key":20,"text":229,"correct":22},".等于0",{"key":24,"text":231,"correct":26},".等于本线路对地电容电流",{"key":28,"text":233,"correct":22},".等于各线路对地电容电流之和",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":20,"analysis":30},716836,"三段式电流保护中限时电流速断的特点为()。",[238,240,242],{"key":20,"text":239,"correct":26},".带有短延时,通过动作电流的整定和短延时保证选择性,可以保护线路全长",{"key":24,"text":241,"correct":22},".无动作延时,通过动作电流的整定保证选择性,只能保护线路始端一部分",{"key":28,"text":243,"correct":22},".带有较长延时,通过动作电流间的灵敏度配合、动作时限的配合保证选择性,能够保护本线路的全长和相邻线路的全长",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":20,"analysis":30},716837,"某变电站油浸式变压器大修后,气体保护出口切换片放于试验位置,突然变压器内部发生相间短路,瓦斯保护动作时结果为()。",[248,250,251,252],{"key":20,"text":249,"correct":26},".发重瓦斯信号,不跳闸",{"key":24,"text":93,"correct":22},{"key":28,"text":97,"correct":22},{"key":42,"text":95,"correct":22},{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":28,"analysis":30},716838,"()采用分级动作,阻止电压降低,避免发生电压崩溃而造成大停电事故。",[257,259,261],{"key":20,"text":258,"correct":22},".继电保护装置",{"key":24,"text":260,"correct":22},".自动重合闸装置",{"key":28,"text":262,"correct":26},".按电压降低自动减负荷装置",{"id":264,"libraryId":5,"type":15,"typeLabel":16,"stem":265,"options":266,"answer":24,"analysis":30},716839,"变压器重瓦斯保护动作时将()。",[267,269,270],{"key":20,"text":268,"correct":22},".延时动作于信号",{"key":24,"text":157,"correct":26},{"key":28,"text":161,"correct":22},{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":20,"analysis":30},716840,"断路器“防跳”措施有()和电气防跳两种。",[275,277,279],{"key":20,"text":276,"correct":26},".机械防跳",{"key":24,"text":278,"correct":22},".手动防跳",{"key":28,"text":280,"correct":22},".人为闭锁防跳",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":20,"analysis":30},716841,"电力系统中母线发生故障,故障的性质绝大部分为()。",[285,287,289],{"key":20,"text":286,"correct":26},".永久性故障",{"key":24,"text":288,"correct":22},".瞬时性故障",{"key":28,"text":290,"correct":22},".间歇性故障",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":24,"analysis":30},716842,"电流互感器的接线方式中,只有二相装有电流互感器和一个电流元件,流入电流元件的电流为两相电流差的接线方式为()。",[295,297,299],{"key":20,"text":296,"correct":22},".三相完全星形接线",{"key":24,"text":298,"correct":26},".两相电流差接线",{"key":28,"text":300,"correct":22},".两相不完全星形接线",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":20,"analysis":30},716843,"电力系统继电保护采用()衡量其可靠性。",[305,307,309],{"key":20,"text":306,"correct":26},".正确动作率",{"key":24,"text":308,"correct":22},".误动作次数",{"key":28,"text":310,"correct":22},".正确动作次数",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":28,"analysis":30},716844,"变压器差动保护的差动元件,当任一差动元件动作时保护即出口跳闸称为()。",[315,317,319,321],{"key":20,"text":316,"correct":22},".分相制动",{"key":24,"text":318,"correct":22},".三相制动",{"key":28,"text":320,"correct":26},".分相差动",{"key":42,"text":322,"correct":22},".三相差动",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":24,"analysis":30},716845,"变压器差动速断元件的动作电流整定时大于变压器的()。",[327,329,331],{"key":20,"text":328,"correct":22},".最大负荷电流",{"key":24,"text":330,"correct":26},".励磁涌流",{"key":28,"text":332,"correct":22},".最大不平衡电流",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":28,"analysis":30},716846,"备用电源自动投入装置应保证工作电源断开后,()才能投入。",[337,339,341,343],{"key":20,"text":338,"correct":22},".工作线路",{"key":24,"text":340,"correct":22},".工作母线",{"key":28,"text":342,"correct":26},".备用电源",{"key":42,"text":344,"correct":22},".工作变压器",{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":28,"analysis":30},716847,"利用电力系统发生相间短路的主要特征可以构成反应()的阶段式电流保护。",[349,351,352],{"key":20,"text":350,"correct":22},".电压升高",{"key":24,"text":179,"correct":22},{"key":28,"text":181,"correct":26},{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":24,"analysis":30},716848,"采用二次谐波制动原理构成的变压器差动保护,当出现短路电流时将()。",[357,359,361],{"key":20,"text":358,"correct":22},".闭锁保护",{"key":24,"text":360,"correct":26},".开放保护",{"key":28,"text":362,"correct":22},".给出闭锁信号",{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":42,"analysis":30},716849,"某区域电力系统由于发生故障引起系统频率下降,此时自动低频减载装置将()。",[367,368,370,372],{"key":20,"text":73,"correct":22},{"key":24,"text":369,"correct":22},".自动断开所有负荷",{"key":28,"text":371,"correct":22},".自动断开重要负荷",{"key":42,"text":373,"correct":26},".自动断开非重要负荷",{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":376,"options":377,"answer":24,"analysis":30},716850,"电压互感器二次回路应装设(),防止电压互感器二次回路短路。",[378,380,382],{"key":20,"text":379,"correct":22},".安全防护罩",{"key":24,"text":381,"correct":26},".熔断器或自动开关",{"key":28,"text":383,"correct":22},".继电保护",{"id":385,"libraryId":5,"type":15,"typeLabel":16,"stem":386,"options":387,"answer":20,"analysis":30},716851,"燃烧与()爆炸原理相同。",[388,390,392],{"key":20,"text":389,"correct":26},"化学",{"key":24,"text":391,"correct":22},"物理",{"key":28,"text":393,"correct":22},"核",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":24,"analysis":30},716852,"继电保护装置对保护范围内故障的反应能力称为继电保护的()。",[398,400,402],{"key":20,"text":399,"correct":22},".选择性",{"key":24,"text":401,"correct":26},".灵敏性",{"key":28,"text":403,"correct":22},".快速性",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":20,"analysis":30},716853,"断路器控制方式中,按照控制断路器数量的不同可分为一对一控制和()。",[408,410,412],{"key":20,"text":409,"correct":26},".一对N控制",{"key":24,"text":411,"correct":22},".一对三控制",{"key":28,"text":413,"correct":22},".一对二控制",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":24,"analysis":30},716854,"继电保护中根据逻辑部分的输出,完成继电保护发出断路器跳闸命令或信号的是()的作用。",[418,420,422],{"key":20,"text":419,"correct":22},".显示部分",{"key":24,"text":421,"correct":26},".执行部分",{"key":28,"text":423,"correct":22},".跳闸部分",{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":20,"analysis":30},716855,"电流互感器一次侧接(),二次侧接负载。",[428,430,432,434],{"key":20,"text":429,"correct":26},".系统一次电流",{"key":24,"text":431,"correct":22},".继电器线圈",{"key":28,"text":433,"correct":22},".电压互感器二次侧",{"key":42,"text":435,"correct":22},".表计",{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":28,"analysis":30},716856,"安装接线图包括屏面布置图、()及端子排图。",[440,442,444,446],{"key":20,"text":441,"correct":22},".原理接线图",{"key":24,"text":443,"correct":22},".流程图",{"key":28,"text":445,"correct":26},".屏背面接线图",{"key":42,"text":447,"correct":22},".逻辑框图",{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":28,"analysis":30},716857,"在变压器差动保护中,由于两侧电流互感器二次阻抗不完全匹配造成的不平衡电流在计算时引入()、电流互感器变比误差系数及非周期分量系数等措施。",[452,454,456,458],{"key":20,"text":453,"correct":22},".电压平衡调整",{"key":24,"text":455,"correct":22},".电流平衡调整",{"key":28,"text":457,"correct":26},".电流互感器同型系数",{"key":42,"text":459,"correct":22},".调整电压互感器的变比",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":20,"analysis":30},716858,"当电动机的容量小于2MW且电流速断保护不能满足灵敏度要求的电动机采用()。",[464,466,468],{"key":20,"text":465,"correct":26},".纵差动保护",{"key":24,"text":467,"correct":22},".起动时间过长保护",{"key":28,"text":469,"correct":22},".低电压保护",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":24,"analysis":30},716859,"过电压继电器的()之比称为过电压继电器的返回系数。",[474,476,478],{"key":20,"text":475,"correct":22},".返回电流与动作电流",{"key":24,"text":477,"correct":26},".返回电压与动作电压",{"key":28,"text":479,"correct":22},".动作电流与返回电流",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":28,"analysis":30},716860,"变压器低电压起动的过电流保护由电流元件、电压元件和()构成。",[484,486,488,490],{"key":20,"text":485,"correct":22},".功率元件",{"key":24,"text":487,"correct":22},".零序元件",{"key":28,"text":489,"correct":26},".时间元件",{"key":42,"text":491,"correct":22},".负序元件",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":20,"analysis":30},716861,"零序电流III段保护动作时限与反应相间故障过电流保护动作时限比较()。",[496,498,500],{"key":20,"text":497,"correct":26},".零序电流III段保护动作时限小于过电流保护动作时限",{"key":24,"text":499,"correct":22},".零序电流III段保护动作时限大于过电流保护动作时限",{"key":28,"text":501,"correct":22},".零序电流III段保护动作时限等于过电流保护动作时限",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":28,"analysis":30},716862,"电动机的过负荷保护采用定时限特性时,保护动作时限应大于(),一般取9~16S。",[506,508,510,512],{"key":20,"text":507,"correct":22},".电动机的最大允许堵转时间",{"key":24,"text":509,"correct":22},".电动机的速断保护动作时间",{"key":28,"text":511,"correct":26},".电动机的起动时间",{"key":42,"text":513,"correct":22},".电动机的最大允许过热时间",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":42,"analysis":30},716863,"微机保护是指将微型机、微控制器等作为核心部件构成的()。",[518,520,522,524],{"key":20,"text":519,"correct":22},".低压开关柜",{"key":24,"text":521,"correct":22},".仿真系统",{"key":28,"text":523,"correct":22},".高压开关柜",{"key":42,"text":383,"correct":26},{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":20,"analysis":30},716864,"在双侧电源线路上实现自动重合闸,应考虑()的问题。",[529,531,533],{"key":20,"text":530,"correct":26},".合闸时两侧电源间的同步",{"key":24,"text":532,"correct":22},".合闸时间",{"key":28,"text":534,"correct":22},".合闸方式",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":28,"analysis":30},716865,"自动低频减载装置的作用为()及保证重要负荷用电。",[539,541,543],{"key":20,"text":540,"correct":22},".保证普通负荷正常运行",{"key":24,"text":542,"correct":22},".保证继电保护动作的选择性",{"key":28,"text":544,"correct":26},".保证电力系统安全稳定运行",[546,549,552,554,557,560],{"id":547,"name":548,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":550,"name":551,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":553,"name":551,"category":7,"favorite":8},336,{"id":555,"name":556,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":558,"name":559,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":561,"name":562,"category":7,"favorite":8},353,"(N1)叉车司机"]