[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-392-1":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":549},{"id":5,"name":6,"category":7,"favorite":8},392,"继电保护","特种作业",0,1,50,1668,[13,33,45,55,67,76,88,100,110,120,130,140,152,164,174,184,194,206,218,228,240,250,257,267,277,287,299,309,319,329,341,349,361,371,383,395,405,415,426,438,448,458,469,479,489,499,509,519,529,539],{"id":14,"libraryId":5,"type":9,"typeLabel":15,"stem":16,"options":17,"answer":26,"analysis":32},716366,"单选题","变压器电流速断保护动作电流按躲过变压器负荷侧母线短路时流过保护的最大短路电流,并躲过()整定。",[18,22,25,29],{"key":19,"text":20,"correct":21},"A",".变压器电源侧母线短路时流过保护的最大短路电流",false,{"key":23,"text":24,"correct":21},"B",".最大负荷电流",{"key":26,"text":27,"correct":28},"C",".变压器空载投入时的励磁涌流",true,{"key":30,"text":31,"correct":21},"D",".最小负荷电流","",{"id":34,"libraryId":5,"type":9,"typeLabel":15,"stem":35,"options":36,"answer":26,"analysis":32},716367,"在正常情况下没有断开的备用电源或备用线路,而是工作在分段母线状态,靠分段断路器取得相互备用的备用方式称为()。",[37,39,41,43],{"key":19,"text":38,"correct":21},".变压器备用",{"key":23,"text":40,"correct":21},".明备用",{"key":26,"text":42,"correct":28},".暗备用",{"key":30,"text":44,"correct":21},".母线备用",{"id":46,"libraryId":5,"type":9,"typeLabel":15,"stem":47,"options":48,"answer":19,"analysis":32},716368,"电力系统出现过负荷属于()。",[49,51,53],{"key":19,"text":50,"correct":28},".异常运行状态",{"key":23,"text":52,"correct":21},".故障状态",{"key":26,"text":54,"correct":21},".正常运行状态",{"id":56,"libraryId":5,"type":9,"typeLabel":15,"stem":57,"options":58,"answer":23,"analysis":32},716369,"变压器主保护包括()、电流速断保护、纵差动保护。",[59,61,63,65],{"key":19,"text":60,"correct":21},".过负荷保护",{"key":23,"text":62,"correct":28},".气体保护",{"key":26,"text":64,"correct":21},".零序保护",{"key":30,"text":66,"correct":21},".过电流保护",{"id":68,"libraryId":5,"type":9,"typeLabel":15,"stem":69,"options":70,"answer":23,"analysis":32},716370,"测量仪表一般用于反应()的电流,因此一般不允许继电保护与测量仪表共用同一电流互感器。",[71,72,74],{"key":19,"text":52,"correct":21},{"key":23,"text":73,"correct":28},".正常状态",{"key":26,"text":75,"correct":21},".异常状态",{"id":77,"libraryId":5,"type":9,"typeLabel":15,"stem":78,"options":79,"answer":26,"analysis":32},716371,"微机保护数据采集系统包括()、模拟滤波器、采样保持、多路转换、模数转换等功能模块。",[80,82,84,86],{"key":19,"text":81,"correct":21},".逻辑判断",{"key":23,"text":83,"correct":21},".软件算法",{"key":26,"text":85,"correct":28},".电压形成",{"key":30,"text":87,"correct":21},".人机接口",{"id":89,"libraryId":5,"type":9,"typeLabel":15,"stem":90,"options":91,"answer":23,"analysis":32},716372,"实际电流互感器在电流变换过程中存在误差,一次电流与二次电流之比并不等于其变比,称为()。",[92,94,96,98],{"key":19,"text":93,"correct":21},".相角误差",{"key":23,"text":95,"correct":28},".变比误差",{"key":26,"text":97,"correct":21},".相对误差",{"key":30,"text":99,"correct":21},".绝对误差",{"id":101,"libraryId":5,"type":9,"typeLabel":15,"stem":102,"options":103,"answer":19,"analysis":32},716373,"零序电流III段保护动作电流的整定原则为()。",[104,106,108],{"key":19,"text":105,"correct":28},".躲过最大不平衡电流",{"key":23,"text":107,"correct":21},".躲过线路最大负荷电流",{"key":26,"text":109,"correct":21},".与下级线路零序电流II段保护配合",{"id":111,"libraryId":5,"type":9,"typeLabel":15,"stem":112,"options":113,"answer":19,"analysis":32},716374,"电力系统中性点不接地系统发生单相接地故障时,三相线电压()。",[114,116,118],{"key":19,"text":115,"correct":28},".对称",{"key":23,"text":117,"correct":21},".不对称",{"key":26,"text":119,"correct":21},".某一线电压为0,其余两线电压不变",{"id":121,"libraryId":5,"type":9,"typeLabel":15,"stem":122,"options":123,"answer":23,"analysis":32},716375,"继电保护中相间短路通常仅考虑三相短路、()几种情况。",[124,126,128],{"key":19,"text":125,"correct":21},".单相接地短路",{"key":23,"text":127,"correct":28},".两相短路",{"key":26,"text":129,"correct":21},".二相断开",{"id":131,"libraryId":5,"type":9,"typeLabel":15,"stem":132,"options":133,"answer":23,"analysis":32},716376,"电动机正序过电流保护可作为电动机的()。",[134,136,138],{"key":19,"text":135,"correct":21},".堵转保护",{"key":23,"text":137,"correct":28},".对称过负荷保护",{"key":26,"text":139,"correct":21},".起动时间过长保护",{"id":141,"libraryId":5,"type":9,"typeLabel":15,"stem":142,"options":143,"answer":23,"analysis":32},716377,"电力系统的故障性质可分为永久性故障和()。",[144,146,148,150],{"key":19,"text":145,"correct":21},".线路故障",{"key":23,"text":147,"correct":28},".瞬时性故障",{"key":26,"text":149,"correct":21},".电缆故障",{"key":30,"text":151,"correct":21},".母线故障",{"id":153,"libraryId":5,"type":9,"typeLabel":15,"stem":154,"options":155,"answer":26,"analysis":32},716378,"本线路的限时电流速断保护动作时间的整定原则为()。",[156,158,160,162],{"key":19,"text":157,"correct":21},".与下级线路限时电流速断保护配合",{"key":23,"text":159,"correct":21},".与本线路瞬时电流速断保护配合",{"key":26,"text":161,"correct":28},".与下级线路瞬时电流速断保护配合",{"key":30,"text":163,"correct":21},".与零序电流速断保护配合",{"id":165,"libraryId":5,"type":9,"typeLabel":15,"stem":166,"options":167,"answer":26,"analysis":32},716379,"电流保护中电磁型电流继电器的返回系数一般不小于()。",[168,170,172],{"key":19,"text":169,"correct":21},".2",{"key":23,"text":171,"correct":21},".0.2",{"key":26,"text":173,"correct":28},".0.85",{"id":175,"libraryId":5,"type":9,"typeLabel":15,"stem":176,"options":177,"answer":19,"analysis":32},716380,"时间继电器在继电保护中主要实现()。",[178,180,182],{"key":19,"text":179,"correct":28},".动作延时",{"key":23,"text":181,"correct":21},".出口跳闸",{"key":26,"text":183,"correct":21},".启动保护",{"id":185,"libraryId":5,"type":9,"typeLabel":15,"stem":186,"options":187,"answer":26,"analysis":32},716381,"分立元件构成的继电保护二次接线图,展开式原理图中正电源采用的标号为()。",[188,190,192],{"key":19,"text":189,"correct":21},".400-599",{"key":23,"text":191,"correct":21},"201,202",{"key":26,"text":193,"correct":28},".101,201",{"id":195,"libraryId":5,"type":9,"typeLabel":15,"stem":196,"options":197,"answer":30,"analysis":32},716382,"变压器油箱外故障包括引出线上的相间故障、引出线的套管闪络故障及()等。",[198,200,202,204],{"key":19,"text":199,"correct":21},".绕组间的相间故障",{"key":23,"text":201,"correct":21},".一相绕组匝间短路",{"key":26,"text":203,"correct":21},".绕组与铁芯之间的单相接地故障",{"key":30,"text":205,"correct":28},".套管破碎通过外壳发生的单相接地故障",{"id":207,"libraryId":5,"type":9,"typeLabel":15,"stem":208,"options":209,"answer":23,"analysis":32},716383,"变电站直流操作电源中()属于独立电源。",[210,212,214,216],{"key":19,"text":211,"correct":21},".复式整流直流电源",{"key":23,"text":213,"correct":28},".蓄电池组直流电源",{"key":26,"text":215,"correct":21},".硅整流电容储能直流电源",{"key":30,"text":217,"correct":21},".交流电源-直流发电机组",{"id":219,"libraryId":5,"type":9,"typeLabel":15,"stem":220,"options":221,"answer":23,"analysis":32},716384,"微机保护的基本构成包括硬件和()。",[222,224,226,227],{"key":19,"text":223,"correct":21},".模数变换",{"key":23,"text":225,"correct":28},".软件",{"key":26,"text":87,"correct":21},{"key":30,"text":81,"correct":21},{"id":229,"libraryId":5,"type":9,"typeLabel":15,"stem":230,"options":231,"answer":26,"analysis":32},716385,"电流继电器动作后,使继电器返回到原始状态的最大电流称为电流继电器的()。",[232,234,236,238],{"key":19,"text":233,"correct":21},".动作电流",{"key":23,"text":235,"correct":21},".返回系数",{"key":26,"text":237,"correct":28},".返回电流",{"key":30,"text":239,"correct":21},".感应电流",{"id":241,"libraryId":5,"type":9,"typeLabel":15,"stem":242,"options":243,"answer":26,"analysis":32},716386,"电流继电器的()之比称为电流继电器的返回系数。",[244,246,248],{"key":19,"text":245,"correct":21},".返回电压与动作电压",{"key":23,"text":247,"correct":21},".动作电流与返回电流",{"key":26,"text":249,"correct":28},".返回电流与动作电流",{"id":251,"libraryId":5,"type":9,"typeLabel":15,"stem":252,"options":253,"answer":23,"analysis":32},716387,"电力系统出现频率降低属于()。",[254,255,256],{"key":19,"text":52,"correct":21},{"key":23,"text":50,"correct":28},{"key":26,"text":54,"correct":21},{"id":258,"libraryId":5,"type":9,"typeLabel":15,"stem":259,"options":260,"answer":23,"analysis":32},716388,"电动机过热保护为电动机各种过负荷引起的过热提供保护,也作为电动机短路、起动时间过长、堵转等的()。",[261,263,265],{"key":19,"text":262,"correct":21},".主保护",{"key":23,"text":264,"correct":28},".后备保护",{"key":26,"text":266,"correct":21},".主要保护",{"id":268,"libraryId":5,"type":9,"typeLabel":15,"stem":269,"options":270,"answer":19,"analysis":32},716389,"继电保护中用于测量被保护对象的各类运行参数,在故障情况下将测得的故障参数与给定的整定值进行比较,将比较结果输出给逻辑部分的是()的作用。",[271,273,275],{"key":19,"text":272,"correct":28},".测量部分",{"key":23,"text":274,"correct":21},".逻辑部分",{"key":26,"text":276,"correct":21},".显示部分",{"id":278,"libraryId":5,"type":9,"typeLabel":15,"stem":279,"options":280,"answer":23,"analysis":32},716390,"限时电流速断保护的保护范围为线路全长,灵敏度校验应选择()进行校验。",[281,283,285],{"key":19,"text":282,"correct":21},".对保护最有利的情况",{"key":23,"text":284,"correct":28},".对保护最不利的情况",{"key":26,"text":286,"correct":21},".随便一种情况",{"id":288,"libraryId":5,"type":9,"typeLabel":15,"stem":289,"options":290,"answer":23,"analysis":32},716391,"变压器零序电流保护用于反应()。",[291,293,295,297],{"key":19,"text":292,"correct":21},".外部故障引起的过电流",{"key":23,"text":294,"correct":28},".变压器高压侧系统的接地故障",{"key":26,"text":296,"correct":21},".油箱漏油造成油面降低",{"key":30,"text":298,"correct":21},".三相对称过负荷",{"id":300,"libraryId":5,"type":9,"typeLabel":15,"stem":301,"options":302,"answer":23,"analysis":32},716392,"电动机的外部发生两相短路,电动机的正序电流()负序电流。",[303,305,307],{"key":19,"text":304,"correct":21},".大于",{"key":23,"text":306,"correct":28},".小于",{"key":26,"text":308,"correct":21},".等于",{"id":310,"libraryId":5,"type":9,"typeLabel":15,"stem":311,"options":312,"answer":26,"analysis":32},716393,"人工急救胸外挤压法应以每分钟约()次的频率有节奏均匀的挤压,挤压与放松的时间相当。",[313,315,317],{"key":19,"text":314,"correct":21},"60",{"key":23,"text":316,"correct":21},"80",{"key":26,"text":318,"correct":28},"100",{"id":320,"libraryId":5,"type":9,"typeLabel":15,"stem":321,"options":322,"answer":19,"analysis":32},716394,"变压器接地保护也称为()。",[323,325,327],{"key":19,"text":324,"correct":28},".变压器零序保护",{"key":23,"text":326,"correct":21},".变压器正序保护",{"key":26,"text":328,"correct":21},".变压器负序保护",{"id":330,"libraryId":5,"type":9,"typeLabel":15,"stem":331,"options":332,"answer":19,"analysis":32},716395,"电压互感器一次绕组和二次绕组的极性通常采用()标注。",[333,335,337,339],{"key":19,"text":334,"correct":28},".减极性原则",{"key":23,"text":336,"correct":21},".加极性原则",{"key":26,"text":338,"correct":21},".阶梯时限原则",{"key":30,"text":340,"correct":21},".同极性原则",{"id":342,"libraryId":5,"type":9,"typeLabel":15,"stem":343,"options":344,"answer":26,"analysis":32},716396,"电力系统短路中发生()的几率最小。",[345,346,347],{"key":19,"text":125,"correct":21},{"key":23,"text":127,"correct":21},{"key":26,"text":348,"correct":28},".三相短路",{"id":350,"libraryId":5,"type":9,"typeLabel":15,"stem":351,"options":352,"answer":30,"analysis":32},716397,"采用二次谐波制动原理构成的变压器差动保护,当出现励磁涌流时将()。",[353,355,357,359],{"key":19,"text":354,"correct":21},".开放保护",{"key":23,"text":356,"correct":21},".发动作信号",{"key":26,"text":358,"correct":21},".起动合闸",{"key":30,"text":360,"correct":28},".闭锁保护",{"id":362,"libraryId":5,"type":9,"typeLabel":15,"stem":363,"options":364,"answer":19,"analysis":32},716398,"自动重合闸装置按照重合闸作用断路器的方式可分为三相重合闸、单相重合闸和()。",[365,367,369],{"key":19,"text":366,"correct":28},".综合重合闸",{"key":23,"text":368,"correct":21},".二次重合闸",{"key":26,"text":370,"correct":21},".一次重合闸",{"id":372,"libraryId":5,"type":9,"typeLabel":15,"stem":373,"options":374,"answer":26,"analysis":32},716399,"变压器电流速断保护作为变压器的主保护,动作时间为()。",[375,377,379,381],{"key":19,"text":376,"correct":21},".1S",{"key":23,"text":378,"correct":21},".0.5S",{"key":26,"text":380,"correct":28},".0S",{"key":30,"text":382,"correct":21},".1.5S",{"id":384,"libraryId":5,"type":9,"typeLabel":15,"stem":385,"options":386,"answer":26,"analysis":32},716400,"对于容量在800kVA及以上的油浸式变压器以及()的车间内油浸式变压器,应装设瓦斯保护。",[387,389,391,393],{"key":19,"text":388,"correct":21},".500kV及以上",{"key":23,"text":390,"correct":21},".500kV及以下",{"key":26,"text":392,"correct":28},".400kV及以上",{"key":30,"text":394,"correct":21},".600kV及以上",{"id":396,"libraryId":5,"type":9,"typeLabel":15,"stem":397,"options":398,"answer":26,"analysis":32},716401,"电动机的过负荷保护的动作时间与()相配合。",[399,401,403],{"key":19,"text":400,"correct":21},".电动机的最大允许堵转时间",{"key":23,"text":402,"correct":21},".电动机的速断保护动作时间",{"key":26,"text":404,"correct":28},".电动机的允许过负荷时间",{"id":406,"libraryId":5,"type":9,"typeLabel":15,"stem":407,"options":408,"answer":23,"analysis":32},716402,"当断路器重合于永久性故障,继电保护再次跳开断路器切除故障,这一过程带来影响之一为()。",[409,411,413],{"key":19,"text":410,"correct":21},".影响继电保护动作的可靠性",{"key":23,"text":412,"correct":28},".使电力系统以及一些电气设备再次受到故障冲击",{"key":26,"text":414,"correct":21},".影响自动重合闸的动作性能",{"id":416,"libraryId":5,"type":9,"typeLabel":15,"stem":417,"options":418,"answer":26,"analysis":32},716403,"对于容量在()单独运行变压器应装设纵差动保护。",[419,421,423,425],{"key":19,"text":420,"correct":21},".800kV及以上",{"key":23,"text":422,"correct":21},".10000kV以下",{"key":26,"text":424,"correct":28},".10000kV以上",{"key":30,"text":392,"correct":21},{"id":427,"libraryId":5,"type":9,"typeLabel":15,"stem":428,"options":429,"answer":23,"analysis":32},716404,"造成变压器差动保护不平衡电流的因素有电流互感器变比标准化、两侧电流互感器二次阻抗不完全匹配及()等。",[430,432,434,436],{"key":19,"text":431,"correct":21},".电压互感器的影响",{"key":23,"text":433,"correct":28},".变压器分接头调整",{"key":26,"text":435,"correct":21},".保护定值偏高",{"key":30,"text":437,"correct":21},".差动继电器动作电流偏小",{"id":439,"libraryId":5,"type":9,"typeLabel":15,"stem":440,"options":441,"answer":23,"analysis":32},716405,"为保证零序电流保护有较稳定的保护区和灵敏度,考虑中性点接地的多少、分布时,应使电网中对应零序电流的网络尽可能()。",[442,444,446],{"key":19,"text":443,"correct":21},".灵活,可随时调整",{"key":23,"text":445,"correct":28},".保持不变或变化较小",{"key":26,"text":447,"correct":21},".有较大变化",{"id":449,"libraryId":5,"type":9,"typeLabel":15,"stem":450,"options":451,"answer":23,"analysis":32},716406,"继电保护装置是在()或异常运行情况下动作的一种自动装置。",[452,454,456],{"key":19,"text":453,"correct":21},".频率升高",{"key":23,"text":455,"correct":28},".电力系统故障",{"key":26,"text":457,"correct":21},".频率降低",{"id":459,"libraryId":5,"type":9,"typeLabel":15,"stem":460,"options":461,"answer":19,"analysis":32},716407,"常用的变压器相间短路的后备保护有过电流保护、低电压起动的过电流保护、()、负序过电流保护、阻抗保护等。",[462,464,466,468],{"key":19,"text":463,"correct":28},".复合电压起动的过电流保护",{"key":23,"text":465,"correct":21},".电流速断保护",{"key":26,"text":467,"correct":21},".变压器差动保护",{"key":30,"text":62,"correct":21},{"id":470,"libraryId":5,"type":9,"typeLabel":15,"stem":471,"options":472,"answer":26,"analysis":32},716408,"电动机运行中由过热保护跳闸时()。",[473,475,477],{"key":19,"text":474,"correct":21},".电动机禁止再起动回路动作,电动机可以再起动",{"key":23,"text":476,"correct":21},".电动机禁止再起动回路不动作,电动机可以再起动",{"key":26,"text":478,"correct":28},".电动机禁止再起动回路动作,电动机不能再起动",{"id":480,"libraryId":5,"type":9,"typeLabel":15,"stem":481,"options":482,"answer":23,"analysis":32},716409,"中性点不接地系统通常采用接地选线和()的方式实现单相接地保护。",[483,485,487],{"key":19,"text":484,"correct":21},".零序电流I段保护",{"key":23,"text":486,"correct":28},".绝缘监视",{"key":26,"text":488,"correct":21},".零序电流II段保护",{"id":490,"libraryId":5,"type":9,"typeLabel":15,"stem":491,"options":492,"answer":26,"analysis":32},716410,"电力系统发生不对称短路,各相序电流中()的三相大小相等,相位相同。",[493,495,497],{"key":19,"text":494,"correct":21},".正序电流",{"key":23,"text":496,"correct":21},".负序电流",{"key":26,"text":498,"correct":28},".零序电流",{"id":500,"libraryId":5,"type":9,"typeLabel":15,"stem":501,"options":502,"answer":23,"analysis":32},716411,"限时电流速断保护灵敏度校验条件为以本线路()两相短路时,流过保护的最小短路电流进行校验。",[503,505,507],{"key":19,"text":504,"correct":21},".首端",{"key":23,"text":506,"correct":28},".末端",{"key":26,"text":508,"correct":21},".中间",{"id":510,"libraryId":5,"type":9,"typeLabel":15,"stem":511,"options":512,"answer":19,"analysis":32},716412,"电动机的相间短路保护动作于()。",[513,515,517],{"key":19,"text":514,"correct":28},".跳闸",{"key":23,"text":516,"correct":21},".信号",{"key":26,"text":518,"correct":21},".减负荷",{"id":520,"libraryId":5,"type":9,"typeLabel":15,"stem":521,"options":522,"answer":26,"analysis":32},716413,"中性点直接接地系统发生接地故障,()零序电压最高。",[523,525,527],{"key":19,"text":524,"correct":21},".直接接地的中性点",{"key":23,"text":526,"correct":21},".远离故障点",{"key":26,"text":528,"correct":28},".接地故障点",{"id":530,"libraryId":5,"type":9,"typeLabel":15,"stem":531,"options":532,"answer":23,"analysis":32},716414,"Ⅱ类设备的防触电保护是采取()措施。这种设备不采用保护接地的措施,也不依赖于安装条件。",[533,535,537],{"key":19,"text":534,"correct":21},"安全电压",{"key":23,"text":536,"correct":28},"双重绝缘",{"key":26,"text":538,"correct":21},"变压器油绝缘",{"id":540,"libraryId":5,"type":9,"typeLabel":15,"stem":541,"options":542,"answer":23,"analysis":32},716415,"自动低频减载装置按照()下降的不同程度,自动分级断开相应的非重要负荷。",[543,545,547],{"key":19,"text":544,"correct":21},".电压",{"key":23,"text":546,"correct":28},".频率",{"key":26,"text":548,"correct":21},".电流",[550,553,556,558,561,564],{"id":551,"name":552,"category":7,"favorite":9},401,"高处安装、维护、拆除",{"id":554,"name":555,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":557,"name":555,"category":7,"favorite":8},336,{"id":559,"name":560,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":562,"name":563,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":565,"name":566,"category":7,"favorite":8},353,"(N1)叉车司机"]