[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-390-8":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":505},{"id":5,"name":6,"category":7,"favorite":8},390,"高压电工","特种作业",0,8,50,1312,[13,31,41,51,61,71,81,91,101,111,121,131,141,151,161,171,181,191,201,211,221,229,239,249,259,269,276,283,291,301,311,321,331,341,351,361,371,381,391,401,411,421,429,436,446,456,466,475,485,495],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":30},715404,1,"单选题","金属氧化锌避雷器安装时,接地引下线应尽量()。",[19,23,26],{"key":20,"text":21,"correct":22},"A","短",false,{"key":24,"text":25,"correct":22},"B","长",{"key":27,"text":28,"correct":29},"C","短而直",true,"",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":20,"analysis":30},715405,"线路验电应逐相进行。同杆架设的多层电力线路验电时,先验低压后验高压、()。",[35,37,39],{"key":20,"text":36,"correct":29},"先验下层后验上层",{"key":24,"text":38,"correct":22},"验下层",{"key":27,"text":40,"correct":22},"先验上层后验下层",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":24,"analysis":30},715406,"电力变压器按冷却介质可分为()和干式两种。",[45,47,49],{"key":20,"text":46,"correct":22},"风冷式",{"key":24,"text":48,"correct":29},"油浸式",{"key":27,"text":50,"correct":22},"自冷式",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":20,"analysis":30},715407,"电力系统进行无功补偿起到的作用之一是()。",[55,57,59],{"key":20,"text":56,"correct":29},"提高设备利用效率",{"key":24,"text":58,"correct":22},"提高设备可靠性",{"key":27,"text":60,"correct":22},"提高设备安全性",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":24,"analysis":30},715408,"低压电网中的TN-C-S系统,整个系统内()。",[65,67,69],{"key":20,"text":66,"correct":22},"中性线(零线)N和保护线PE是合用的",{"key":24,"text":68,"correct":29},"中性线(零线)N与保护线PE是部分合用的",{"key":27,"text":70,"correct":22},"中性线(零线)N与保护线PE是分开的",{"id":72,"libraryId":5,"type":15,"typeLabel":16,"stem":73,"options":74,"answer":27,"analysis":30},715409,"高分断能力高压熔断器的特点之一是分断()的能力强。",[75,77,79],{"key":20,"text":76,"correct":22},"负荷电流",{"key":24,"text":78,"correct":22},"过负荷电流",{"key":27,"text":80,"correct":29},"短路电流",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":24,"analysis":30},715410,"隔离开关的主要作用之一是()。",[85,87,89],{"key":20,"text":86,"correct":22},"隔离电流",{"key":24,"text":88,"correct":29},"倒闸操作",{"key":27,"text":90,"correct":22},"拉合负荷电流",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":27,"analysis":30},715411,"变压器的铁芯是()部分。",[95,97,99],{"key":20,"text":96,"correct":22},"开路",{"key":24,"text":98,"correct":22},"电路",{"key":27,"text":100,"correct":29},"磁路",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":20,"analysis":30},715412,"继电保护装置按被保护的对象分类,有电力线路保护、发电机保护、变压器保护、电动机保护、()等。",[105,107,109],{"key":20,"text":106,"correct":29},"母线保护",{"key":24,"text":108,"correct":22},"差动保护",{"key":27,"text":110,"correct":22},"后备保护",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":20,"analysis":30},715413,"变压器的额定电流等于绕组的额定容量除以该绕组的额定电压及相应的相系数()。",[115,117,119],{"key":20,"text":116,"correct":29},"单相和三相均为√3",{"key":24,"text":118,"correct":22},"单相和三相均为1",{"key":27,"text":120,"correct":22},"三相为1,单相为√3",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":24,"analysis":30},715414,"电杆底盘基础的作用()。",[125,127,129],{"key":20,"text":126,"correct":22},"以防电杆倒塌",{"key":24,"text":128,"correct":29},"以防电杆下沉",{"key":27,"text":130,"correct":22},"以防电杆上拔",{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":24,"analysis":30},715415,"供电电压允许偏差通常是以电压实际值和电压额定值之差与电压()之比的百分数来表示。",[135,137,139],{"key":20,"text":136,"correct":22},"实际值",{"key":24,"text":138,"correct":29},"额定值",{"key":27,"text":140,"correct":22},"瞬时值",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":24,"analysis":30},715416,"KYN28-10型高压开关柜小车室内的主回路触头盒遮挡帘板具有()的作用。",[145,147,149],{"key":20,"text":146,"correct":22},"保护设备安全",{"key":24,"text":148,"correct":29},"保护小车室内工作人员安全",{"key":27,"text":150,"correct":22},"保护断路器小车出、入安全",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":20,"analysis":30},715417,"在运行中,()和电火花或电弧等都是电气火灾的直接原因。",[155,157,159],{"key":20,"text":156,"correct":29},"电流的热量",{"key":24,"text":158,"correct":22},"电压高低",{"key":27,"text":160,"correct":22},"环境温度",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":24,"analysis":30},715418,"阀型避雷器都由火花间隙和阀电阻片组成,装在密封的瓷套管内。火花间隙用铜片冲制而成,每对间隙用()厚的云母垫圈隔开。",[165,167,169],{"key":20,"text":166,"correct":22},"0.5-1.5mm",{"key":24,"text":168,"correct":29},"0.5-1.0mm",{"key":27,"text":170,"correct":22},"1.5-2.0mm",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":24,"analysis":30},715419,"三相变压器绕组为D联结时,()。",[175,177,179],{"key":20,"text":176,"correct":22},"线电流为绕组电流",{"key":24,"text":178,"correct":29},"线电流为√3倍的绕组电流",{"key":27,"text":180,"correct":22},"线电流为2倍的绕组电流",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":20,"analysis":30},715420,"如图所示, 已知UAB为10V,在R1上的电压降U1为5V,电流IAB为5A,求R2上的电压降U2和电阻R2值符合下列选项的是()。",[185,187,189],{"key":20,"text":186,"correct":29},"5V,1Ω",{"key":24,"text":188,"correct":22},"5V,2Ω",{"key":27,"text":190,"correct":22},"10V,1Ω",{"id":192,"libraryId":5,"type":15,"typeLabel":16,"stem":193,"options":194,"answer":20,"analysis":30},715421,"(),只有在发生短路事故时或者在负荷电流较大时,变流器中才会有足够的二次电流作为继电保护跳闸之用。",[195,197,199],{"key":20,"text":196,"correct":29},"变流器供给操作电源",{"key":24,"text":198,"correct":22},"交流电压供给操作电源",{"key":27,"text":200,"correct":22},"直流操作电源",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":27,"analysis":30},715422,"()可以将电力系统的一次大电流按一定的变比变换成二次较小电流,供给测量表计和继电器。",[205,207,209],{"key":20,"text":206,"correct":22},"继电器",{"key":24,"text":208,"correct":22},"电压互感器",{"key":27,"text":210,"correct":29},"电流互感器",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":24,"analysis":30},715423,"()指正常情况下没有断开的备用电源或备用设备,而是工作在分段母线状态,靠分段断路器取得相互备用。",[215,217,219],{"key":20,"text":216,"correct":22},"明备用",{"key":24,"text":218,"correct":29},"暗备用",{"key":27,"text":220,"correct":22},"冷备用",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":27,"analysis":30},715424,"()是将系统的高电压改变为标准的低电压(100V或100\u002F√3V),供测量仪表、继电保护自动装置、计算机监控系统用。",[225,227,228],{"key":20,"text":226,"correct":22},"变压器",{"key":24,"text":210,"correct":22},{"key":27,"text":208,"correct":29},{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":20,"analysis":30},715425,"()是指变压器线圈中的电阻损耗,与电流大小的平方成正比,它是一个变量。",[233,235,237],{"key":20,"text":234,"correct":29},"铜损",{"key":24,"text":236,"correct":22},"线损",{"key":27,"text":238,"correct":22},"磁损",{"id":240,"libraryId":5,"type":15,"typeLabel":16,"stem":241,"options":242,"answer":24,"analysis":30},715426,"()是指那些绝缘强度能长期承受设备的工作电压,并且在该电压等级产生内部过电压时能保证工作人员安全的用具。",[243,245,247],{"key":20,"text":244,"correct":22},"绝缘安全用具",{"key":24,"text":246,"correct":29},"基本安全用具",{"key":27,"text":248,"correct":22},"一般防护安全用具",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":27,"analysis":30},715427,"()用来防护高压雷电波侵入变、配电所或其他建筑物内,损坏被保护设备。",[253,255,257],{"key":20,"text":254,"correct":22},"避雷针",{"key":24,"text":256,"correct":22},"避雷线",{"key":27,"text":258,"correct":29},"避雷器",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":24,"analysis":30},715428,"()的作用是将悬式绝缘子组装成串,并将一串或数串绝缘子连接起来悬挂在横担上。",[263,265,267],{"key":20,"text":264,"correct":22},"支持金具",{"key":24,"text":266,"correct":29},"连接金具",{"key":27,"text":268,"correct":22},"接续金具",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":27,"analysis":30},715429,"()的作用是支持导线或避雷线,使导线和避雷线固定在绝缘子或杆塔上。",[273,274,275],{"key":20,"text":268,"correct":22},{"key":24,"text":266,"correct":22},{"key":27,"text":264,"correct":29},{"id":277,"libraryId":5,"type":15,"typeLabel":16,"stem":278,"options":279,"answer":27,"analysis":30},715430,"()的作用是用于导线和避雷线的接续和修补等。",[280,281,282],{"key":20,"text":264,"correct":22},{"key":24,"text":266,"correct":22},{"key":27,"text":268,"correct":29},{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":20,"analysis":30},715431,"()的绝缘强度不能承受电气设备或线路的工作电压,只能起加强基本安全用具的保护作用。",[287,289,290],{"key":20,"text":288,"correct":29},"辅助安全用具",{"key":24,"text":248,"correct":22},{"key":27,"text":244,"correct":22},{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":20,"analysis":30},715432,"220V\u002F380V低压系统,如人体电阻为1000Ω,则遭受单相触电时,通过人体的电流约为()。",[295,297,299],{"key":20,"text":296,"correct":29},"220mA",{"key":24,"text":298,"correct":22},"30mA",{"key":27,"text":300,"correct":22},"380mA",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":24,"analysis":30},715433,"35~110kV线路电缆进线段为三芯电缆时,避雷器接地端应与电缆金属外皮连接,其末端金属外皮应()。",[305,307,309],{"key":20,"text":306,"correct":22},"对地绝缘",{"key":24,"text":308,"correct":29},"直接接地",{"key":27,"text":310,"correct":22},"经保护器接地",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":20,"analysis":30},715434,"FW5-10负荷开关的含意是()。",[315,317,319],{"key":20,"text":316,"correct":29},"额定电压10kV户外型负荷开关",{"key":24,"text":318,"correct":22},"额定电压5kV户外型负荷开关",{"key":27,"text":320,"correct":22},"额定电压10kV户内型负荷开关",{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":27,"analysis":30},715435,"IT系统是指电源中性点不接地或经足够大阻抗(约1000Ω)接地,电气设备的外露可导电部分经各自的()分别直接接地的三相三线制低压配电系统。",[325,327,329],{"key":20,"text":326,"correct":22},"PEN线",{"key":24,"text":328,"correct":22},"中性线N",{"key":27,"text":330,"correct":29},"保护线PE",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":27,"analysis":30},715436,"KYN28-10型高压开关柜采用电缆出线时,如需要装设零序电流互感器,零序电流互感器一般装设在()。",[335,337,339],{"key":20,"text":336,"correct":22},"主母线室",{"key":24,"text":338,"correct":22},"吊装在电缆室内",{"key":27,"text":340,"correct":29},"吊装在电缆室柜底板外部",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":24,"analysis":30},715437,"KYN28-10系列高压开关柜中小车与接地开关防误操作的联锁装置包括()。",[345,347,349],{"key":20,"text":346,"correct":22},"接地开关摇把还没有取下时,小车可以由试验位置的定位状态转变为移动状态",{"key":24,"text":348,"correct":29},"接地开关处于合闸位置,小车不能由定位状态转变为移动状态",{"key":27,"text":350,"correct":22},"接地开关处于分闸位置,小车不能由定位状态转变为移动状态",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":27,"analysis":30},715438,"LQJ-10表示额定电压为()的绕组式树脂浇注绝缘的电流互感器。",[355,357,359],{"key":20,"text":356,"correct":22},"35kV",{"key":24,"text":358,"correct":22},"20kV",{"key":27,"text":360,"correct":29},"10kV",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":20,"analysis":30},715439,"SF₆断路器的特点之一是()。",[365,367,369],{"key":20,"text":366,"correct":29},"开断电流大",{"key":24,"text":368,"correct":22},"断口耐压低",{"key":27,"text":370,"correct":22},"开断电流小",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":20,"analysis":30},715440,"SF₆负荷开关-熔断器组合电器在更换熔断器前应()。",[375,377,379],{"key":20,"text":376,"correct":29},"合上接地开关",{"key":24,"text":378,"correct":22},"使操动机构储能",{"key":27,"text":380,"correct":22},"使负荷开关合闸",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":20,"analysis":30},715441,"SF₆负荷开关一般不设置()。",[385,387,389],{"key":20,"text":386,"correct":29},"气体吹弧装置",{"key":24,"text":388,"correct":22},"灭弧装置",{"key":27,"text":390,"correct":22},"磁吹灭弧装置",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":24,"analysis":30},715442,"SF₆负荷开关的灭弧能力较SF₆断路器()。",[395,397,399],{"key":20,"text":396,"correct":22},"强",{"key":24,"text":398,"correct":29},"弱",{"key":27,"text":400,"correct":22},"相同",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":27,"analysis":30},715443,"SF₆负荷开关装设的()可随时监测开关本体内充入的SF₆气体压力。",[405,407,409],{"key":20,"text":406,"correct":22},"气体流量计",{"key":24,"text":408,"correct":22},"温度计",{"key":27,"text":410,"correct":29},"气体密度计",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":24,"analysis":30},715444,"SFZ-10000\u002F110表示三相自然循环风冷有载调压,额定容量为()kVA,高压绕组额定电压110kV电力变压器。",[415,417,419],{"key":20,"text":416,"correct":22},"36500",{"key":24,"text":418,"correct":29},"10000",{"key":27,"text":420,"correct":22},"8000",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":24,"analysis":30},715445,"TN系统电源系统有一点(通常是中性点)接地,而设备的外露可导电部分(如金属外壳)通过()连接到此接地点的低压配电系统。",[425,427,428],{"key":20,"text":426,"correct":22},"相线",{"key":24,"text":330,"correct":29},{"key":27,"text":328,"correct":22},{"id":430,"libraryId":5,"type":15,"typeLabel":16,"stem":431,"options":432,"answer":27,"analysis":30},715446,"TT系统是指电源中性点直接接地,而设备的外露可导电部分经各自的()分别直接接地的三相四线制低压供电系统。",[433,434,435],{"key":20,"text":426,"correct":22},{"key":24,"text":328,"correct":22},{"key":27,"text":330,"correct":29},{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":20,"analysis":30},715447,"TT系统是指电源中性点直接接地,而设备的外露可导电部分经各自的PE线分别直接接地的()低压供电系统。",[440,442,444],{"key":20,"text":441,"correct":29},"三相四线制",{"key":24,"text":443,"correct":22},"三相五线制",{"key":27,"text":445,"correct":22},"三相三线制",{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":27,"analysis":30},715448,"Ⅱ类移动式电气设备和Ⅲ类移动式电气设备修理后()原设计确定的安全技术标准。",[450,452,454],{"key":20,"text":451,"correct":22},"可以降低",{"key":24,"text":453,"correct":22},"可以稍微降低",{"key":27,"text":455,"correct":29},"不得降低",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":20,"analysis":30},715449,"一个()不能同时执行多张工作票。",[460,462,464],{"key":20,"text":461,"correct":29},"工作负责人",{"key":24,"text":463,"correct":22},"工作班成员",{"key":27,"text":465,"correct":22},"施工班组",{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":24,"analysis":30},715450,"一式二份的工作票,一份由工作负责人收执,作为进行工作的依据,一份由()收执,按值移交。",[470,471,473],{"key":20,"text":461,"correct":22},{"key":24,"text":472,"correct":29},"运行值班员",{"key":27,"text":474,"correct":22},"工作票签发人",{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":24,"analysis":30},715451,"一般发生短路故障后约0.01s时间出现最大短路冲击电流,采用微机保护一般仅需()s就能发出跳闸指令,使导体和设备避免承受最大短路电流的冲击,从而达到限制短路电流的目的。",[479,481,483],{"key":20,"text":480,"correct":22},"0.002",{"key":24,"text":482,"correct":29},"0.005",{"key":27,"text":484,"correct":22},"0.003",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":20,"analysis":30},715452,"一般地,电力系统的运行电压在正常情况下不会超过()。",[489,491,493],{"key":20,"text":490,"correct":29},"最高工作电压",{"key":24,"text":492,"correct":22},"额定线电压",{"key":27,"text":494,"correct":22},"绝缘水平",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":24,"analysis":30},715453,"三相系统中发生的短路有4种基本类型,三相短路、()、单相接地短路和两相接地短路。",[499,501,503],{"key":20,"text":500,"correct":22},"相相短路",{"key":24,"text":502,"correct":29},"两相短路",{"key":27,"text":504,"correct":22},"相地短路",[506,509,512,514,517,520],{"id":507,"name":508,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":510,"name":511,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":513,"name":511,"category":7,"favorite":8},336,{"id":515,"name":516,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":518,"name":519,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":521,"name":522,"category":7,"favorite":8},353,"(N1)叉车司机"]