[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-390-2":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":516},{"id":5,"name":6,"category":7,"favorite":8},390,"高压电工","特种作业",0,2,50,1312,[13,31,41,51,61,71,81,91,101,111,121,131,141,151,161,171,181,191,201,211,221,231,241,251,259,269,279,289,299,309,319,329,339,349,359,369,379,389,399,409,419,427,437,447,457,467,477,486,499,507],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":30},715104,1,"单选题","SH11-M-50\u002F10表示三相油浸自冷式,双绕组无励磁调压,非晶态合金铁芯,密封式,额定容量50kVA,高压侧绕组额定电压为()kV的电力变压器。",[19,23,27],{"key":20,"text":21,"correct":22},"A","10",true,{"key":24,"text":25,"correct":26},"B","20",false,{"key":28,"text":29,"correct":26},"C","35","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":28,"analysis":30},715105,"保护接地的接地电阻不能大于()。",[35,37,39],{"key":20,"text":36,"correct":26},"15Ω",{"key":24,"text":38,"correct":26},"10Ω",{"key":28,"text":40,"correct":22},"4Ω",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":28,"analysis":30},715106,"在纯电感的交流电路中,电流的相位滞后电压相位()。",[45,47,49],{"key":20,"text":46,"correct":26},"30°",{"key":24,"text":48,"correct":26},"60°",{"key":28,"text":50,"correct":22},"90°",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":28,"analysis":30},715107,"高压熔断器熔体中间焊有小锡(铅)球,利用()降低熔丝熔点。",[55,57,59],{"key":20,"text":56,"correct":26},"热聚集",{"key":24,"text":58,"correct":26},"热扩散",{"key":28,"text":60,"correct":22},"“冶金效应”",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":20,"analysis":30},715108,"电力网的电力线路按用途一般可分为()。",[65,67,69],{"key":20,"text":66,"correct":22},"输电线路和配电线路",{"key":24,"text":68,"correct":26},"输电线路和用电线路",{"key":28,"text":70,"correct":26},"高压线路和配电线路",{"id":72,"libraryId":5,"type":15,"typeLabel":16,"stem":73,"options":74,"answer":28,"analysis":30},715109,"金属氧化锌避雷器特点有动作迅速、()、残压低、通流量大。",[75,77,79],{"key":20,"text":76,"correct":26},"续流小",{"key":24,"text":78,"correct":26},"能耗低",{"key":28,"text":80,"correct":22},"无续流",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":20,"analysis":30},715110,"当变压器过负载时,一般会发出()。",[85,87,89],{"key":20,"text":86,"correct":22},"很高且沉重的嗡嗡声",{"key":24,"text":88,"correct":26},"很轻且细微的嗡嗡声",{"key":28,"text":90,"correct":26},"很高且沉重的沸腾声",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":20,"analysis":30},715111,"110KV及以下线路保护测控装置,当开关在跳位而(),延时10秒报TWJ异常。",[95,97,99],{"key":20,"text":96,"correct":22},"线路有流",{"key":24,"text":98,"correct":26},"线路无压",{"key":28,"text":100,"correct":26},"线路有压",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":28,"analysis":30},715112,"装设临时接地线的顺序是()。",[105,107,109],{"key":20,"text":106,"correct":26},"同时接接地端和设备导体部分",{"key":24,"text":108,"correct":26},"先接设备导体部分,后接接地端",{"key":28,"text":110,"correct":22},"先接接地端,后接设备导体部分",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":20,"analysis":30},715113,"变压器正常运行时发出()。",[115,117,119],{"key":20,"text":116,"correct":22},"均匀的嗡嗡声",{"key":24,"text":118,"correct":26},"间断的嗡嗡声",{"key":28,"text":120,"correct":26},"均匀的沸腾声",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":28,"analysis":30},715114,"倒闸操作票由()填写。",[125,127,129],{"key":20,"text":126,"correct":26},"许可人",{"key":24,"text":128,"correct":26},"监护人",{"key":28,"text":130,"correct":22},"操作人",{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":20,"analysis":30},715115,"所有断路器,隔离开关均断开,在有可能来电端挂好地线,说明设备处于()状态。",[135,137,139],{"key":20,"text":136,"correct":22},"检修",{"key":24,"text":138,"correct":26},"运行",{"key":28,"text":140,"correct":26},"备用",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":24,"analysis":30},715116,"拆除临时接地线的顺序是()。",[145,147,149],{"key":20,"text":146,"correct":26},"先拆除接地端,后拆除设备导体部分",{"key":24,"text":148,"correct":22},"先拆除设备导体部分,后拆除接地端",{"key":28,"text":150,"correct":26},"同时拆除接地端和设备导体部分",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":20,"analysis":30},715117,"扑灭火灾时,灭火人员应站在()进行灭火。",[155,157,159],{"key":20,"text":156,"correct":22},"上风侧",{"key":24,"text":158,"correct":26},"下风侧",{"key":28,"text":160,"correct":26},"侧面",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":24,"analysis":30},715118,"真空断路器是利用()作绝缘介质和灭弧介质的断路器。",[165,167,169],{"key":20,"text":166,"correct":26},"空气",{"key":24,"text":168,"correct":22},"“真空”",{"key":28,"text":170,"correct":26},"惰性气体",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":28,"analysis":30},715119,"SF₆断路器的缺点之一是,SF₆气体在电弧的作用下分解的()气体有毒。",[175,177,179],{"key":20,"text":176,"correct":26},"硫化物",{"key":24,"text":178,"correct":26},"氧化物",{"key":28,"text":180,"correct":22},"低氟化物",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":20,"analysis":30},715120,"下列电缆编号属于35kV线路间隔的是()。",[185,187,189],{"key":20,"text":186,"correct":22},"1U123C",{"key":24,"text":188,"correct":26},"1Y123B",{"key":28,"text":190,"correct":26},"1E123",{"id":192,"libraryId":5,"type":15,"typeLabel":16,"stem":193,"options":194,"answer":28,"analysis":30},715121,"降低杆塔接地电阻,线路的跳闸率()。",[195,197,199],{"key":20,"text":196,"correct":26},"不变化",{"key":24,"text":198,"correct":26},"增大",{"key":28,"text":200,"correct":22},"降低",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":24,"analysis":30},715122,"FN5-10的型号含意是()。",[205,207,209],{"key":20,"text":206,"correct":26},"额定电压10kV断路器",{"key":24,"text":208,"correct":22},"额定电压10kV户内型负荷开关",{"key":28,"text":210,"correct":26},"额定电压10kV户外型负荷开关",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":24,"analysis":30},715123,"以下过电压中()属于内部过电压。",[215,217,219],{"key":20,"text":216,"correct":26},"大气过电压",{"key":24,"text":218,"correct":22},"操作过电压",{"key":28,"text":220,"correct":26},"感应雷过电压",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":24,"analysis":30},715124,"发生高压设备、导线接地故障时,在室外人体不得接近接地故障点()以内。",[225,227,229],{"key":20,"text":226,"correct":26},"4m",{"key":24,"text":228,"correct":22},"8m",{"key":28,"text":230,"correct":26},"10m",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":20,"analysis":30},715125,"互感器分()和电流互感器两大类,它们是供电系统中测量、保护、监控用的重要设备。",[235,237,239],{"key":20,"text":236,"correct":22},"电压互感器",{"key":24,"text":238,"correct":26},"断路器",{"key":28,"text":240,"correct":26},"隔离开关",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":24,"analysis":30},715126,"当电路断开时,电源端电压在数值上()电源电动势。",[245,247,249],{"key":20,"text":246,"correct":26},"大于",{"key":24,"text":248,"correct":22},"等于",{"key":28,"text":250,"correct":26},"小于",{"id":252,"libraryId":5,"type":15,"typeLabel":16,"stem":253,"options":254,"answer":28,"analysis":30},715127,"设备的断路器,隔离开关都在合闸位置,说明设备处在()状态。",[255,257,258],{"key":20,"text":256,"correct":26},"设备用",{"key":24,"text":136,"correct":26},{"key":28,"text":138,"correct":22},{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":28,"analysis":30},715128,"导体在磁场中做切割磁力线运动时,导体内就会产生()。",[263,265,267],{"key":20,"text":264,"correct":26},"磁场",{"key":24,"text":266,"correct":26},"电流",{"key":28,"text":268,"correct":22},"感应电动势",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":28,"analysis":30},715129,"万用表测量电阻时,如果被测电阻未接入,则指针指示()。",[273,275,277],{"key":20,"text":274,"correct":26},"0位",{"key":24,"text":276,"correct":26},"中间位",{"key":28,"text":278,"correct":22},"∞位",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":24,"analysis":30},715130,"在一类负荷的供电要求中,允许中断供电时间在()小时以上的供电系统,可选用快速自启动的发电机组。",[283,285,287],{"key":20,"text":284,"correct":26},"12",{"key":24,"text":286,"correct":22},"15",{"key":28,"text":288,"correct":26},"13",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":28,"analysis":30},715131,"控制电缆的编号中,打头字母表征电缆的归属,如“Y”就表示该电缆归属于()。",[293,295,297],{"key":20,"text":294,"correct":26},"330kV线路间隔单元",{"key":24,"text":296,"correct":26},"220kV线路间隔单元",{"key":28,"text":298,"correct":22},"110kV线路间隔单元",{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":28,"analysis":30},715132,"负载接成星形时,相电压等于线电压的()倍。",[303,305,307],{"key":20,"text":304,"correct":26},"根号2",{"key":24,"text":306,"correct":26},"1",{"key":28,"text":308,"correct":22},"1\u002F根号3",{"id":310,"libraryId":5,"type":15,"typeLabel":16,"stem":311,"options":312,"answer":28,"analysis":30},715133,"电流互感器的变流比为一次绕组的()与二次绕组额定电流之比。",[313,315,317],{"key":20,"text":314,"correct":26},"最大电流",{"key":24,"text":316,"correct":26},"最小电流",{"key":28,"text":318,"correct":22},"额定电流",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":28,"analysis":30},715134,"可以不断开线路测量电流的仪表是()。",[323,325,327],{"key":20,"text":324,"correct":26},"电流表",{"key":24,"text":326,"correct":26},"万用表",{"key":28,"text":328,"correct":22},"钳表",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":24,"analysis":30},715135,"如果电流表不慎并联在线路中,不可能出现的是()。",[333,335,337],{"key":20,"text":334,"correct":26},"损坏仪表",{"key":24,"text":336,"correct":22},"指针无反应",{"key":28,"text":338,"correct":26},"指针满偏",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":20,"analysis":30},715136,"真空断路器要求波纹管既能保证动触头能做(),同时又不能破坏灭弧室的真空度。",[343,345,347],{"key":20,"text":344,"correct":22},"直线运动",{"key":24,"text":346,"correct":26},"弧线运动",{"key":28,"text":348,"correct":26},"分合运动",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":20,"analysis":30},715137,"手车式开关柜,小车已推入,开关合入,称之为()。",[353,355,357],{"key":20,"text":354,"correct":22},"运行状态",{"key":24,"text":356,"correct":26},"备用状态",{"key":28,"text":358,"correct":26},"检修状态",{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":24,"analysis":30},715138,"变压器的损耗包括()和铜损。",[363,365,367],{"key":20,"text":364,"correct":26},"线损",{"key":24,"text":366,"correct":22},"铁损",{"key":28,"text":368,"correct":26},"磁损",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":28,"analysis":30},715139,"用环氧树脂浇注或缠绕作包封的干式变压器即称为()。",[373,375,377],{"key":20,"text":374,"correct":26},"气体绝缘干式变压器",{"key":24,"text":376,"correct":26},"H级绝缘干式变压器",{"key":28,"text":378,"correct":22},"环氧树脂干式变压器",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":24,"analysis":30},715140,"()用具是登高作业时必须必备的保护用具。",[383,385,387],{"key":20,"text":384,"correct":26},"登高板",{"key":24,"text":386,"correct":22},"安全带",{"key":28,"text":388,"correct":26},"脚扣",{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":20,"analysis":30},715141,"()指正常情况下有明显断开的备用电源或备用设备或备用线路。",[393,395,397],{"key":20,"text":394,"correct":22},"明备用",{"key":24,"text":396,"correct":26},"冷备用",{"key":28,"text":398,"correct":26},"暗备用",{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":24,"analysis":30},715142,"()的作用是警告工作人员不得接近设备的带电部分,提醒工作人员在工作地点采取安全措施,以及禁止向某设备合闸送电等。",[403,405,407],{"key":20,"text":404,"correct":26},"绝缘台",{"key":24,"text":406,"correct":22},"标示牌",{"key":28,"text":408,"correct":26},"绝缘垫",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":20,"analysis":30},715143,"架空线路装设自动重合闸装置后,可以()。",[413,415,417],{"key":20,"text":414,"correct":22},"提高供电可靠性",{"key":24,"text":416,"correct":26},"提高耐雷水平",{"key":28,"text":418,"correct":26},"降低杆塔接地电阻",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":20,"analysis":30},715144,"对于正弦交流电,最大值等于有效值的()倍。",[423,424,425],{"key":20,"text":304,"correct":22},{"key":24,"text":306,"correct":26},{"key":28,"text":426,"correct":26},"根号3",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":28,"analysis":30},715145,"变压器()通常分为无励磁调压和有载调压两种方式。",[431,433,435],{"key":20,"text":432,"correct":26},"运行方式",{"key":24,"text":434,"correct":26},"连接方式",{"key":28,"text":436,"correct":22},"调压方式",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":20,"analysis":30},715146,"在运行的控制盘、低压配电盘、低压配电箱上的维护工作应使用()。",[441,443,445],{"key":20,"text":442,"correct":22},"第二种工作票",{"key":24,"text":444,"correct":26},"第一种工作票",{"key":28,"text":446,"correct":26},"口头指令",{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":20,"analysis":30},715147,"通常要求真空断路器的触头材料具有的性能之一是()。",[451,453,455],{"key":20,"text":452,"correct":22},"耐弧性强",{"key":24,"text":454,"correct":26},"导热性能差",{"key":28,"text":456,"correct":26},"绝缘性能强",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":20,"analysis":30},715148,"用万用表测量电阻时,则需要将()作为测量电源。",[461,463,465],{"key":20,"text":462,"correct":22},"表内电池",{"key":24,"text":464,"correct":26},"外接电源",{"key":28,"text":466,"correct":26},"电阻电压",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":28,"analysis":30},715149,"中性点不接地的电力系统中,用电设备的绝缘水平应按()考虑。",[471,473,475],{"key":20,"text":472,"correct":26},"相电压",{"key":24,"text":474,"correct":26},"2倍相电压",{"key":28,"text":476,"correct":22},"线电压",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":20,"analysis":30},715150,"下列仪表属于比较式仪表的是()。",[481,483,484],{"key":20,"text":482,"correct":22},"接地电阻测量仪",{"key":24,"text":326,"correct":26},{"key":28,"text":485,"correct":26},"兆欧表",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":24,"analysis":30},715151,"变压器上层油温正常时一般应在85℃以下,对强迫油循环水冷或风冷的变压器上层油温不得超过()。",[490,492,494,496],{"key":20,"text":491,"correct":26},"60℃",{"key":24,"text":493,"correct":22},"75℃",{"key":28,"text":495,"correct":26},"65℃",{"key":497,"text":498,"correct":26},"D","57℃",{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":28,"analysis":30},715152,"屋顶上单支避雷针的保护范围可按保护角()确定。",[503,504,506],{"key":20,"text":46,"correct":26},{"key":24,"text":505,"correct":26},"45°",{"key":28,"text":48,"correct":22},{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":20,"analysis":30},715153,"新敷设的带有中间接头的电缆线路,在投入运行()个月后,应进行预防性试验。",[511,513,514],{"key":20,"text":512,"correct":22},"3",{"key":24,"text":306,"correct":26},{"key":28,"text":515,"correct":26},"5",[517,520,523,525,528,531],{"id":518,"name":519,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":521,"name":522,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":524,"name":522,"category":7,"favorite":8},336,{"id":526,"name":527,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":529,"name":530,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":532,"name":533,"category":7,"favorite":8},353,"(N1)叉车司机"]