[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-390-10":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":482},{"id":5,"name":6,"category":7,"favorite":8},390,"高压电工","特种作业",0,10,50,1312,[13,31,41,51,61,71,81,91,101,111,120,130,140,150,157,167,176,186,196,206,216,226,235,243,250,257,264,271,281,291,301,311,321,328,335,345,355,365,372,380,390,400,407,417,427,437,444,454,464,472],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":30},715504,1,"单选题","在()的电力系统中,由于发生单相完全接地时,非故障相对地电位升高为线电压,容易引起绝缘损坏,从而引起两相或三相短路,造成事故。",[19,23,27],{"key":20,"text":21,"correct":22},"A","中性点不接地",true,{"key":24,"text":25,"correct":26},"B","中性点经消弧线圈接地",false,{"key":28,"text":29,"correct":26},"C","中性点直接接地","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":28,"analysis":30},715505,"在110kV及以上的电力系统,一般采用中性点直接接地的运行方式,以()。",[35,37,39],{"key":20,"text":36,"correct":26},"保障人身设备安全",{"key":24,"text":38,"correct":26},"保障人身安全",{"key":28,"text":40,"correct":22},"降低设备的绝缘水平",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":28,"analysis":30},715506,"在三个电阻并联的电路中,已知三条并联支路的电流分别为4A、8A和15A,则电路的电流等于()A。",[45,47,49],{"key":20,"text":46,"correct":26},"9",{"key":24,"text":48,"correct":26},"15",{"key":28,"text":50,"correct":22},"27",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":24,"analysis":30},715507,"在三相四线式380V电源供电的电气设备或者单相设备与三相设备共用的电路,应选择()漏电保护装置",[55,57,59],{"key":20,"text":56,"correct":26},"三相三极式",{"key":24,"text":58,"correct":22},"三相四极式",{"key":28,"text":60,"correct":26},"三相三极和单相二极两种",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":28,"analysis":30},715508,"在不损害变压器()和降低变压器使用寿命的前提下,变压器在较短时间内所能输出的最大容量为变压器的过负载能力。",[65,67,69],{"key":20,"text":66,"correct":26},"套管",{"key":24,"text":68,"correct":26},"线圈",{"key":28,"text":70,"correct":22},"绝缘",{"id":72,"libraryId":5,"type":15,"typeLabel":16,"stem":73,"options":74,"answer":20,"analysis":30},715509,"在中性点不接地的电力系统中,当发生单相接地故障时,流入大地的电流若过大,就会在接地故障点出现断续电弧而引起()。",[75,77,79],{"key":20,"text":76,"correct":22},"过电压",{"key":24,"text":78,"correct":26},"过电流",{"key":28,"text":80,"correct":26},"过负荷",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":24,"analysis":30},715510,"在中性点接地的电力系统中,以()的短路故障最多,约占全部故障的90%。",[85,87,89],{"key":20,"text":86,"correct":26},"三相短路",{"key":24,"text":88,"correct":22},"单相接地",{"key":28,"text":90,"correct":26},"两相短路",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":28,"analysis":30},715511,"在中性点直接接地电网中的剩余电流保护器后面的电网零线不准再(),以免引起保护器误动作。",[95,97,99],{"key":20,"text":96,"correct":26},"保护接零",{"key":24,"text":98,"correct":26},"直接接地",{"key":28,"text":100,"correct":22},"重复接地",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":24,"analysis":30},715512,"在中性点经消弧线圈接地系统中,如果消弧线圈选择得当,可使接地点电流小于(),而不会产生断续电弧和过电压现象。",[105,107,109],{"key":20,"text":106,"correct":26},"电弧电流",{"key":24,"text":108,"correct":22},"生弧电流",{"key":28,"text":110,"correct":26},"补偿电流",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":24,"analysis":30},715513,"在中性点经消弧线圈接地系统中,当发生()故障时,一般允许运行2h,需发出报警信号。",[115,117,118],{"key":20,"text":116,"correct":26},"三相接地短路",{"key":24,"text":88,"correct":22},{"key":28,"text":119,"correct":26},"两项接地短路",{"id":121,"libraryId":5,"type":15,"typeLabel":16,"stem":122,"options":123,"answer":28,"analysis":30},715514,"在中性点经消弧线圈接地系统中,当系统发生单相接地时,接地电容电流与消弧线圈电流(),在接地点相互补偿,使接地电流减小。",[124,126,128],{"key":20,"text":125,"correct":26},"相差90°",{"key":24,"text":127,"correct":26},"方向相同",{"key":28,"text":129,"correct":22},"方向相反",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":20,"analysis":30},715515,"在二类负荷的供电要求中,二类负荷的供电系统宜采用()回路线供电。",[134,136,138],{"key":20,"text":135,"correct":22},"双",{"key":24,"text":137,"correct":26},"单",{"key":28,"text":139,"correct":26},"三",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":28,"analysis":30},715516,"在低压配电系统中安装剩余电流动作保护器,作为直接接触触电保护的()。",[144,146,148],{"key":20,"text":145,"correct":26},"直接防护措施",{"key":24,"text":147,"correct":26},"后备防护措施",{"key":28,"text":149,"correct":22},"补充防护措施",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":20,"analysis":30},715517,"在低压配电系统中广泛采用的TN系统和TT系统,均为()运行方式,其目的是保障人身设备安全。",[154,155,156],{"key":20,"text":29,"correct":22},{"key":24,"text":21,"correct":26},{"key":28,"text":25,"correct":26},{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":24,"analysis":30},715518,"在全部停电和部分停电的电气设备上工作时,必须完成的技术措施有:()、验电、挂接地线、装设遮栏和悬挂标示牌。",[161,163,165],{"key":20,"text":162,"correct":26},"放电",{"key":24,"text":164,"correct":22},"停电",{"key":28,"text":166,"correct":26},"设置安全措施",{"id":168,"libraryId":5,"type":15,"typeLabel":16,"stem":169,"options":170,"answer":20,"analysis":30},715519,"在全部停电和部分停电的电气设备上工作时,必须完成的技术措施有:停电、()、挂接地线、装设遮栏和悬挂标示牌。",[171,173,174],{"key":20,"text":172,"correct":22},"验电",{"key":24,"text":162,"correct":26},{"key":28,"text":175,"correct":26},"巡视安全检查",{"id":177,"libraryId":5,"type":15,"typeLabel":16,"stem":178,"options":179,"answer":28,"analysis":30},715520,"在办理停电、送电手续时,严禁()停电、送电。",[180,182,184],{"key":20,"text":181,"correct":26},"规定时间",{"key":24,"text":183,"correct":26},"延长时间",{"key":28,"text":185,"correct":22},"约定时间",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":28,"analysis":30},715521,"在变压器内部发生故障(如绝缘击穿、相间短路、匝间短路、铁芯事故等)产生()时,接通信号或跳闸回路,进行报警或跳闸,以保护变压器。",[190,192,194],{"key":20,"text":191,"correct":26},"固体",{"key":24,"text":193,"correct":26},"液体",{"key":28,"text":195,"correct":22},"气体",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":28,"analysis":30},715522,"在变电站外线路工作,一经合闸即可送电到施工线路的线路开关和刀闸操作手柄上应悬挂()标示牌。",[200,202,204],{"key":20,"text":201,"correct":26},"禁止合闸、有人工作",{"key":24,"text":203,"correct":26},"在此工作",{"key":28,"text":205,"correct":22},"禁止合闸,线路有人工作",{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":28,"analysis":30},715523,"在变配电所内工作时,工作许可人应会同()到现场检查所做的安全措施是否完备、可靠,并检验、证明、检修设备确无电压;",[210,212,214],{"key":20,"text":211,"correct":26},"工作票签发人",{"key":24,"text":213,"correct":26},"运行值班人员",{"key":28,"text":215,"correct":22},"工作负责人",{"id":217,"libraryId":5,"type":15,"typeLabel":16,"stem":218,"options":219,"answer":28,"analysis":30},715524,"在变配电站停电检修或安装时,()负责完成安全技术措施与安全组织措施。",[220,222,224],{"key":20,"text":221,"correct":26},"监护人",{"key":24,"text":223,"correct":26},"检修人员",{"key":28,"text":225,"correct":22},"值班员",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":20,"analysis":30},715525,"在室内高压设备上工作,应在工作地点两旁间隔的遮栏上悬挂:()。",[230,232,233],{"key":20,"text":231,"correct":22},"止步,高压危险",{"key":24,"text":205,"correct":26},{"key":28,"text":234,"correct":26},"禁止攀登,高压危险",{"id":236,"libraryId":5,"type":15,"typeLabel":16,"stem":237,"options":238,"answer":28,"analysis":30},715526,"在室外构架上工作,应在工作地点邻近带电部分的横梁上,以及与之邻近的可能误登的架构上悬挂()。",[239,240,242],{"key":20,"text":203,"correct":26},{"key":24,"text":241,"correct":26},"禁止合闸,有人工作",{"key":28,"text":231,"correct":22},{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":24,"analysis":30},715527,"在室外构架上工作,应在工作地点邻近带电部分的横梁上悬挂:()。",[247,248,249],{"key":20,"text":205,"correct":26},{"key":24,"text":231,"correct":22},{"key":28,"text":203,"correct":26},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":24,"analysis":30},715528,"在室外高压设备上工作,应在工作地点四周用绳子做好围栏,在围栏上悬挂()。",[254,255,256],{"key":20,"text":205,"correct":26},{"key":24,"text":231,"correct":22},{"key":28,"text":203,"correct":26},{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":24,"analysis":30},715529,"在工作人员上、下的临近带电设备的铁钩架上和运行中变压器的梯子上应悬挂()标示牌。",[261,262,263],{"key":20,"text":231,"correct":26},{"key":24,"text":234,"correct":22},{"key":28,"text":203,"correct":26},{"id":265,"libraryId":5,"type":15,"typeLabel":16,"stem":266,"options":267,"answer":20,"analysis":30},715530,"在已停电的断路器和隔离开关上的操作把手上挂()标示牌,防止运行人员误合断路器和隔离开关。",[268,269,270],{"key":20,"text":241,"correct":22},{"key":24,"text":203,"correct":26},{"key":28,"text":231,"correct":26},{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":24,"analysis":30},715531,"在特别潮湿场所或工作地点狭窄、行动不方便场所(如金属容器内)应采用()安全电。",[275,277,279],{"key":20,"text":276,"correct":26},"42V",{"key":24,"text":278,"correct":22},"12V",{"key":28,"text":280,"correct":26},"36V",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":28,"analysis":30},715532,"在电力系统中,用得较多的限制短路电流的方法有,()、采用分裂绕组变压器和分段电抗器、采用线路电抗器、采用微机保护及综合自动化装置等。",[285,287,289],{"key":20,"text":286,"correct":26},"并联电容器",{"key":24,"text":288,"correct":26},"真空断路器",{"key":28,"text":290,"correct":22},"选择合适的接线方式",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":28,"analysis":30},715533,"在电气设备上工作,保证安全的电气作业组织措施有:();工作许可制度;工作监护制度;工作间断、转移和终结制度。",[295,297,299],{"key":20,"text":296,"correct":26},"防火安全制度",{"key":24,"text":298,"correct":26},"操作票制度",{"key":28,"text":300,"correct":22},"工作票制度",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":28,"analysis":30},715534,"在电源内部,正电荷是由()。",[305,307,309],{"key":20,"text":306,"correct":26},"高电位移向参考电位",{"key":24,"text":308,"correct":26},"高电位移向低电位",{"key":28,"text":310,"correct":22},"低电位移向高电位",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":20,"analysis":30},715535,"在电路中,将两个及以上的电阻按头尾相接的顺序联接起来,称为电阻的()。",[315,317,319],{"key":20,"text":316,"correct":22},"串联",{"key":24,"text":318,"correct":26},"混联",{"key":28,"text":320,"correct":26},"并联",{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":24,"analysis":30},715536,"在电路中,将两个及以上的电阻的一端全部联接在一点上,而另一端全部连接在另一点上,这样的联接称为电阻的()。",[325,326,327],{"key":20,"text":316,"correct":26},{"key":24,"text":320,"correct":22},{"key":28,"text":318,"correct":26},{"id":329,"libraryId":5,"type":15,"typeLabel":16,"stem":330,"options":331,"answer":24,"analysis":30},715537,"在电路中,既有电阻的并联,又有电阻的串联,这样的电路称为()电路。",[332,333,334],{"key":20,"text":316,"correct":26},{"key":24,"text":318,"correct":22},{"key":28,"text":320,"correct":26},{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":28,"analysis":30},715538,"在电路中,电阻的联接方法主要有()。",[339,341,343],{"key":20,"text":340,"correct":26},"串联和混联",{"key":24,"text":342,"correct":26},"并联和混联",{"key":28,"text":344,"correct":22},"串联、并联和混联",{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":24,"analysis":30},715539,"在纯电容交流电路中,电路的无功功率()。",[349,351,353],{"key":20,"text":350,"correct":26},"小于电路电压与电流的有效值的乘积",{"key":24,"text":352,"correct":22},"等于电路电压与电流的有效值的乘积",{"key":28,"text":354,"correct":26},"大于电路电压与电流的有效值的乘积",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":24,"analysis":30},715540,"在纯电感交流电路中,电路的()。",[359,361,363],{"key":20,"text":360,"correct":26},"有功功率大于零",{"key":24,"text":362,"correct":22},"有功功率等于零",{"key":28,"text":364,"correct":26},"有功功率小于零",{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":28,"analysis":30},715541,"在纯电感交流电路中,电路的无功功率()。",[369,370,371],{"key":20,"text":350,"correct":26},{"key":24,"text":354,"correct":26},{"key":28,"text":352,"correct":22},{"id":373,"libraryId":5,"type":15,"typeLabel":16,"stem":374,"options":375,"answer":28,"analysis":30},715542,"在转移工作地点时,()应向工作人员交代带电范围、安全措施和注意事项。",[376,378,379],{"key":20,"text":377,"correct":26},"工作许可人",{"key":24,"text":211,"correct":26},{"key":28,"text":215,"correct":22},{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":24,"analysis":30},715543,"在闭合的变压器铁芯上,绕有两个互相绝缘的绕组,其中,接入电源的一侧叫一次侧绕组,输出电能的一侧为()。",[384,386,388],{"key":20,"text":385,"correct":26},"高压侧绕组",{"key":24,"text":387,"correct":22},"二次侧绕组",{"key":28,"text":389,"correct":26},"低压侧绕组",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":28,"analysis":30},715544,"在高压室内的二次接线和照明回路工作,需将高压设备停电或做安全措施时应使用()。",[394,396,398],{"key":20,"text":395,"correct":26},"口头指令",{"key":24,"text":397,"correct":26},"第二种工作票",{"key":28,"text":399,"correct":22},"第一种工作票",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":28,"analysis":30},715545,"在高压电气设备上进行检修、试验、清扫、检查等工作时,需要全部停电或部分停电时应使用()。",[404,405,406],{"key":20,"text":395,"correct":26},{"key":24,"text":397,"correct":26},{"key":28,"text":399,"correct":22},{"id":408,"libraryId":5,"type":15,"typeLabel":16,"stem":409,"options":410,"answer":20,"analysis":30},715546,"大型的()和大型电弧炉,产生的谐波电流最为突出,是造成电网谐波的主要因素。",[411,413,415],{"key":20,"text":412,"correct":22},"晶闸管变流设备",{"key":24,"text":414,"correct":26},"荧光灯",{"key":28,"text":416,"correct":26},"高压汞灯",{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":419,"options":420,"answer":28,"analysis":30},715547,"如图,正常运行时,母联断路器3QF断开,断路器1QF、2QF闭合,是标准的()。",[421,423,425],{"key":20,"text":422,"correct":26},"进线备自投接线",{"key":24,"text":424,"correct":26},"变压器备自投接线",{"key":28,"text":426,"correct":22},"低压母线分段备自投接线",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":24,"analysis":30},715548,"如果在交接班过程中,有事故要处理,仍由()负责处理,必要时可请接班人员协助工作。",[431,433,435],{"key":20,"text":432,"correct":26},"接班人员",{"key":24,"text":434,"correct":22},"交班人员",{"key":28,"text":436,"correct":26},"调度员",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":20,"analysis":30},715549,"如果在交接班过程中,有异常情况要处理,仍由()负责处理,必要时可请接班人员协助工作。",[441,442,443],{"key":20,"text":434,"correct":22},{"key":24,"text":432,"correct":26},{"key":28,"text":436,"correct":26},{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":28,"analysis":30},715550,"如果忽略变压器的内损耗,可认为变压器二次输出功率()变压器一次输入功率。",[448,450,452],{"key":20,"text":449,"correct":26},"大于",{"key":24,"text":451,"correct":26},"小于",{"key":28,"text":453,"correct":22},"等于",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":24,"analysis":30},715551,"安装剩余电流保护器的设备和没有安装剩余电流保护器的设备不能共用一套()。",[458,460,462],{"key":20,"text":459,"correct":26},"电源",{"key":24,"text":461,"correct":22},"接地装置",{"key":28,"text":463,"correct":26},"零线",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":24,"analysis":30},715552,"完成工作许可手续后,()应向工作班人员交代现场安全措施、带电部位和其他注意事项。",[468,469,470],{"key":20,"text":377,"correct":26},{"key":24,"text":215,"correct":22},{"key":28,"text":471,"correct":26},"被监护人员",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":28,"analysis":30},715553,"容量在10000kVA及以上,或容量在()kVA及以上并列运行变压器或用户中的重要变压器应装设电流纵差动保护。",[476,478,480],{"key":20,"text":477,"correct":26},"2000",{"key":24,"text":479,"correct":26},"3150",{"key":28,"text":481,"correct":22},"6300",[483,486,489,491,494,497],{"id":484,"name":485,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":487,"name":488,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":490,"name":488,"category":7,"favorite":8},336,{"id":492,"name":493,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":495,"name":496,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":498,"name":499,"category":7,"favorite":8},353,"(N1)叉车司机"]