[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-388-8":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":322},{"id":5,"name":6,"category":7,"favorite":8},388,"防爆电气","特种作业",0,8,50,623,[13,28,34,40,46,52,58,64,70,76,82,88,94,100,106,112,118,124,130,136,142,148,154,160,166,172,178,184,190,196,202,208,214,220,226,232,238,244,250,256,262,268,274,280,286,292,298,304,310,316],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":25,"analysis":27},714781,3,"判断题","充油型开关设备可用于移动式电气设备的直流回路设备。",[19,23],{"key":20,"text":21,"correct":22},"A","正确",false,{"key":24,"text":25,"correct":26},"B","错误",true,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":21,"analysis":27},714782,"按温度组别来选择防爆电气设备时,气体的燃点越高,则所选设备组别也要高,即与之相适应。",[32,33],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":25,"analysis":27},714783,"增安型电气设备的主要安全措施是防爆外壳和保护介质。",[38,39],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":25,"analysis":27},714784,"电气间隙越小,爬电距离就越小。",[44,45],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":21,"analysis":27},714785,"“禁止合闸,有人工作”标示牌悬挂位置是一经合闸即送电到施工设备的开关和刀闸操作手柄上。",[50,51],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":21,"analysis":27},714786,"隔爆型是指用钢板、铸铝等金属材料制成的,具有隔爆外壳的电气设备,其防爆标志为“d”。",[56,57],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":25,"analysis":27},714787,"除非制造厂文件有规定,不同截面导体应尽量连接在同一根端子上。",[62,63],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":21,"analysis":27},714788,"“mb”保护等级的浇封型电气设备允许使用在1区。",[68,69],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":21,"analysis":27},714789,"处于爆炸危险场所的电气设备应内外接地。",[74,75],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":21,"analysis":27},714790,"爆炸危险场所的电气线路工作零线必须接在设备的接线端子上,不得接在外壳接地端子上(或内接地螺栓上)。",[80,81],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":21,"analysis":27},714791,"可燃性粉尘环境电缆敷设路线布置应使其积聚粉尘量最少,同时便于清理。",[86,87],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":25,"analysis":27},714792,"防爆充油型设备不得有漏油,但渗油是允许的。",[92,93],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":21,"analysis":27},714793,"防爆合格证编号的附加代号“X”和“U”不能同时使用。",[98,99],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":25,"analysis":27},714794,"安全用具是安全的,可以将安全用具用做任何地方。",[104,105],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":25,"analysis":27},714795,"隔爆型电气设备是指具有隔爆外壳的电气设备,其外壳具有足够的机械强度,一般用金属材料制成。其防爆标志是“p”。",[110,111],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":25,"analysis":27},714796,"n型电动机的外风扇或风扇罩损坏需要更换或修理,其要求与增安型电动机相同。",[116,117],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":25,"analysis":27},714797,"接地法主要用来消除导电体上的静电,不宜用来消除金属体上的静电。",[122,123],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":25,"analysis":27},714798,"防爆电气设备运行需要一定的工作环境,要求环境温度不超过-20℃—+40℃,但如果要在+60℃环境中使用,则应加风扇对着设备不停吹拂散热才可使用。",[128,129],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":25,"analysis":27},714799,"爆炸危险性场所2区内的照明灯具可不设专用接地线,可利用油品的工艺管道、通风管道、金属容器壁等作为保护接地线用。",[134,135],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":21,"analysis":27},714800,"防爆电气设备的性能在使用中会受到工作条件和环境影响。",[140,141],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":21,"analysis":27},714801,"在防爆电气设备选择时要注意:ⅡC类电气设备可用于ⅡA类和ⅡB类环境,但ⅡB类设备则不可用于ⅡC类环境。",[146,147],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":21,"analysis":27},714802,"一台电气设备右上方有“EX”凸字样,名牌上有“epIIT4”标志,表明这是一增安型并带有正压的防爆电气设备。",[152,153],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":25,"analysis":27},714803,"隔爆型电气设备隔爆接合面上如果锈蚀严重,可以用煤油和抹布将锈斑擦去,涂一薄层润滑脂防锈。",[158,159],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":21,"analysis":27},714804,"正压型电气设备密封部件均安装在指定位置。",[164,165],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":21,"analysis":27},714805,"正压型电气设备所有供气的正压管道和连接件应能承受1.5倍最大正常压力。",[170,171],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":25,"analysis":27},714806,"爆炸危险场所防爆电机可采用线槽进线方式。",[176,177],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":25,"analysis":27},714807,"Ⅲ类电气设备用于所有爆炸性粉尘环境。",[182,183],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":21,"analysis":27},714808,"防爆电气设备的正确应用,是工业生产爆炸危险场所安全生产的重要保证。",[188,189],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":25,"analysis":27},714809,"炸药类物质属于爆炸性粉尘、纤维之列。",[194,195],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":21,"analysis":27},714810,"n型电气设备是一种在正常运行时或标准、制造厂规定的异常情况下,不会产生引起点燃的火花或超过温度组别限制的最高表面温度的电气设备。",[200,201],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":21,"analysis":27},714811,"防爆电气设备安装应符合一般电气安装规范,选型合理。",[206,207],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":25,"analysis":27},714812,"在可燃性粉尘危险场所中,A类型设备只可用于被划分为22区,并具有导电性粉尘的环境中。",[212,213],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":25,"analysis":27},714813,"专业性检修视实际情况需要随时进行。",[218,219],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":25,"analysis":27},714814,"简易的防爆电气设备的检修可由电工人员进行简单修理。",[224,225],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":21,"analysis":27},714815,"正压型电气设备防爆的关键措施是设备外壳内部保护性气体(新鲜气体或惰性气体)的压力高于环境的压力至少50Pa。",[230,231],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":25,"analysis":27},714816,"隔爆型电气设备的透明件和密封垫允许修理。",[236,237],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":21,"analysis":27},714817,"增安型电气设备没有防爆的外壳和保护介质。",[242,243],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":21,"analysis":27},714818,"有一台适用于可燃性氨蒸气环境中的电气设备,其防爆标志可以写为\"ExdII(氨)\"。",[248,249],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":21,"analysis":27},714819,"隔爆型电气设备隔爆面应有防腐措施。",[254,255],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":21,"analysis":27},714820,"在爆炸危险场所需动火检修防爆电气设备时,必须办理动火审批手续。",[260,261],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":21,"analysis":27},714821,"防爆电气设备的出厂质量,设备安装,运行维护与检修的好坏,关系到人身和财产安全。",[266,267],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":25,"analysis":27},714822,"增安型电气设备是指在故障情况下都不会产生危险温度、电火花和电弧的电气设备。",[272,273],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":25,"analysis":27},714823,"正压型电气设备,微正压继电器应装在风压、气压最高点出口处。",[278,279],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":21,"analysis":27},714824,"液体流动在管道终端容器里将积累静电。",[284,285],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":21,"analysis":27},714825,"在被划分为20区的可燃性粉尘环境,粉尘若为非导电性则既可选用A型也可选用B型电气设备。",[290,291],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":21,"analysis":27},714826,"按照规定进行定期或不定期的对防爆设备进行检查和维护是是为了保障其在整个服务期间的防爆性能的完好性。",[296,297],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":21,"analysis":27},714827,"直击雷是雷电直接与建筑物(包括电气装置)和构筑物、大地或其他物体之间发生的迅猛发电现象产生电效应、热效应和机械效应。",[302,303],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":25,"analysis":27},714828,"有台隔爆型电气设备,它既可用于Ⅰ类,也可用时ⅡB类环境,如温度组别为T5,则其防爆标志可表示为“ExdⅠ\u002FdⅡBT5\"”。",[308,309],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":25,"analysis":27},714829,"浇封型电气设备是将整台设备或者部件浇封在浇封剂中,以达到防爆的目的。常用的浇封型设备有防爆开关、防爆变压器等。",[314,315],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":25,"analysis":27},714830,"可燃粉尘的袋式集尘设备,织入袋体的金属丝的接地端子不用接地。",[320,321],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},[323,327,330,332,335,338],{"id":324,"name":325,"category":7,"favorite":326},401,"高处安装、维护、拆除",1,{"id":328,"name":329,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":331,"name":329,"category":7,"favorite":8},336,{"id":333,"name":334,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":336,"name":337,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":339,"name":340,"category":7,"favorite":8},353,"(N1)叉车司机"]