[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-388-6":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":509},{"id":5,"name":6,"category":7,"favorite":8},388,"防爆电气","特种作业",0,6,50,623,[13,31,41,51,59,69,79,89,99,109,119,128,138,148,158,168,178,188,198,208,218,228,238,248,256,266,276,286,296,306,316,326,335,345,352,362,372,382,392,402,412,422,432,442,452,459,469,479,489,499],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":30},714681,1,"单选题","防雷引下线不应少于两根,并应沿建筑物四周均匀或对称布置,若用铜导线,其截面不小于()m㎡。",[19,23,27],{"key":20,"text":21,"correct":22},"A","16",true,{"key":24,"text":25,"correct":26},"B","10",false,{"key":28,"text":29,"correct":26},"C","6","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":24,"analysis":30},714682,"防爆设备外壳,对于0区,轻合金外壳允许的质量百分比铝、镁、钛和锆总含量不允许大于()%。",[35,37,39],{"key":20,"text":36,"correct":26},"1",{"key":24,"text":38,"correct":22},"7.5",{"key":28,"text":40,"correct":26},"5",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":20,"analysis":30},714683,"对于粉尘场所还应考虑粉尘层()。",[45,47,49],{"key":20,"text":46,"correct":22},"堆积厚度",{"key":24,"text":48,"correct":26},"体积",{"key":28,"text":50,"correct":26},"质量",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":28,"analysis":30},714684,"易燃或可燃液体的浮动式贮罐,在无防雷接地时,其罐顶与罐体之间应采用铜软线作不少于两处跨接,其截面不应小于()平方毫米。",[55,56,57],{"key":20,"text":25,"correct":26},{"key":24,"text":21,"correct":26},{"key":28,"text":58,"correct":22},"25",{"id":60,"libraryId":5,"type":15,"typeLabel":16,"stem":61,"options":62,"answer":28,"analysis":30},714685,"浇封型电气设备连接电缆的延伸必须采用()过渡连接。",[63,65,67],{"key":20,"text":64,"correct":26},"接线盒",{"key":24,"text":66,"correct":26},"电缆接头",{"key":28,"text":68,"correct":22},"防爆接线盒",{"id":70,"libraryId":5,"type":15,"typeLabel":16,"stem":71,"options":72,"answer":20,"analysis":30},714686,"我国当前防爆电气标志根据新标准GB3836.1-2010,有了新的变化,即在原来的基础上增加了()。",[73,75,77],{"key":20,"text":74,"correct":22},"设备保护级别",{"key":24,"text":76,"correct":26},"接地方式",{"key":28,"text":78,"correct":26},"设备防护措施",{"id":80,"libraryId":5,"type":15,"typeLabel":16,"stem":81,"options":82,"answer":20,"analysis":30},714687,"在爆炸危险场所中,对于IIA、IIB、IIC设备,温度级别T1—T6,安全性最好的组合是()。",[83,85,87],{"key":20,"text":84,"correct":22},"IIC,T6组合",{"key":24,"text":86,"correct":26},"IIA,T1组合",{"key":28,"text":88,"correct":26},"IIB,T5组合",{"id":90,"libraryId":5,"type":15,"typeLabel":16,"stem":91,"options":92,"answer":28,"analysis":30},714688,"螺纹隔爆结构外壳净容积V&lt;100c㎥,其螺纹的最小啮合深度为()mm。",[93,95,97],{"key":20,"text":94,"correct":26},"12.5",{"key":24,"text":96,"correct":26},"9.0",{"key":28,"text":98,"correct":22},"5.0",{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":24,"analysis":30},714689,"增安型电气设备的特点主要表现于绝缘材料好、导体连接方式牢固可靠及()。",[103,105,107],{"key":20,"text":104,"correct":26},"介电强度高",{"key":24,"text":106,"correct":22},"温升低",{"key":28,"text":108,"correct":26},"散热快",{"id":110,"libraryId":5,"type":15,"typeLabel":16,"stem":111,"options":112,"answer":20,"analysis":30},714690,"增安型电气设备导线连接采用多股线时要用凹形垫圈或()。",[113,115,117],{"key":20,"text":114,"correct":22},"专用接头",{"key":24,"text":116,"correct":26},"专用线排",{"key":28,"text":118,"correct":26},"专用端子",{"id":120,"libraryId":5,"type":15,"typeLabel":16,"stem":121,"options":122,"answer":28,"analysis":30},714691,"爆炸气体性环境电气配线导管与导管、导管与电气设备间须用螺纹连接,管径为32mm及以上的钢管不应少于()扣。",[123,125,127],{"key":20,"text":124,"correct":26},"2",{"key":24,"text":126,"correct":26},"4",{"key":28,"text":29,"correct":22},{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":20,"analysis":30},714692,"爆炸性混合物的引燃温度也称为()。",[132,134,136],{"key":20,"text":133,"correct":22},"自燃温度",{"key":24,"text":135,"correct":26},"起火温度",{"key":28,"text":137,"correct":26},"点燃温度",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":24,"analysis":30},714693,"本安型电路如护套或表层需用颜色标志,该颜色应为()。",[142,144,146],{"key":20,"text":143,"correct":26},"黄色",{"key":24,"text":145,"correct":22},"淡蓝色",{"key":28,"text":147,"correct":26},"红褐色",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":28,"analysis":30},714694,"隔爆型电气设备隔爆接合面上的机械划痕的宽度和深度不超过()mm,剩余无伤隔爆面的有效长度不小于GB3836.2-2010规定的三分之二,可以不修理,但划痕突出部分应磨平。",[152,154,156],{"key":20,"text":153,"correct":26},"0.3",{"key":24,"text":155,"correct":26},"0.8",{"key":28,"text":157,"correct":22},"0.5",{"id":159,"libraryId":5,"type":15,"typeLabel":16,"stem":160,"options":161,"answer":20,"analysis":30},714695,"爆炸危险场所的分类可按物质的()来划分。",[162,164,166],{"key":20,"text":163,"correct":22},"物态",{"key":24,"text":165,"correct":26},"危险物质的量",{"key":28,"text":167,"correct":26},"危险程度",{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":28,"analysis":30},714696,"正压型防爆电气设备检修内容包括()。",[172,174,176],{"key":20,"text":173,"correct":26},"活动隔爆结合面",{"key":24,"text":175,"correct":26},"安全栅组件",{"key":28,"text":177,"correct":22},"设备外壳和管道",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":28,"analysis":30},714697,"防爆万用表更换电池时必须在()。",[182,184,186],{"key":20,"text":183,"correct":26},"2区",{"key":24,"text":185,"correct":26},"22区",{"key":28,"text":187,"correct":22},"安全区域",{"id":189,"libraryId":5,"type":15,"typeLabel":16,"stem":190,"options":191,"answer":28,"analysis":30},714698,"在爆炸危险场所中检修电气设备或线路,应在断电处挂()。",[192,194,196],{"key":20,"text":193,"correct":26},"禁止合闸",{"key":24,"text":195,"correct":26},"在此工作",{"key":28,"text":197,"correct":22},"有人工作,禁止合闸",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":28,"analysis":30},714699,"本安型的关联设备一般安装在()。",[202,204,206],{"key":20,"text":203,"correct":26},"电网处",{"key":24,"text":205,"correct":26},"危险场所",{"key":28,"text":207,"correct":22},"安全场所",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":20,"analysis":30},714700,"爆炸危险场所的电气装置,其不带电的金属部分()。",[212,214,216],{"key":20,"text":213,"correct":22},"不可利用金属管道、建筑物或构筑物的金属架作接地线",{"key":24,"text":215,"correct":26},"可利用金属管道、建筑物或构筑物的金属架作接地线",{"key":28,"text":217,"correct":26},"可利用金属管等作接地线,但应使用不少于两根导体与接地网连接",{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":28,"analysis":30},714701,"粉尘防爆型电气设备根据其制造原理及工艺技术,下列说法不正确的是()。",[222,224,226],{"key":20,"text":223,"correct":26},"具有较高的密封性",{"key":24,"text":225,"correct":26},"可允许少量粉尘进入",{"key":28,"text":227,"correct":22},"必须完全阻止粉尘进入电气外壳内",{"id":229,"libraryId":5,"type":15,"typeLabel":16,"stem":230,"options":231,"answer":28,"analysis":30},714702,"当易燃物质比空气重时,电气线路应在()处敷设或直接埋地。",[232,234,236],{"key":20,"text":233,"correct":26},"水平",{"key":24,"text":235,"correct":26},"较低",{"key":28,"text":237,"correct":22},"较高",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":20,"analysis":30},714703,"最小点燃电流比是指相应气体的最小点燃电流相对于()最小点燃电流之比。",[242,244,246],{"key":20,"text":243,"correct":22},"甲烷",{"key":24,"text":245,"correct":26},"乙烷",{"key":28,"text":247,"correct":26},"丙烷",{"id":249,"libraryId":5,"type":15,"typeLabel":16,"stem":250,"options":251,"answer":28,"analysis":30},714704,"本安型电气设备安全栅接地电阻必须小于()Ω。",[252,254,255],{"key":20,"text":253,"correct":26},"3",{"key":24,"text":124,"correct":26},{"key":28,"text":36,"correct":22},{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":20,"analysis":30},714705,"正压型电气设备防爆的关键措施是设备外壳内部保护性气体(新鲜气体或惰性气体)的压力高于环境的压力至少()Pa。",[260,262,264],{"key":20,"text":261,"correct":22},"50",{"key":24,"text":263,"correct":26},"40",{"key":28,"text":265,"correct":26},"60",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":28,"analysis":30},714706,"电气运行中发生火灾的直接原因()。",[270,272,274],{"key":20,"text":271,"correct":26},"电气设备绝缘击穿",{"key":24,"text":273,"correct":26},"电气设备绝缘老化",{"key":28,"text":275,"correct":22},"电流的热量、电火花和电弧",{"id":277,"libraryId":5,"type":15,"typeLabel":16,"stem":278,"options":279,"answer":20,"analysis":30},714707,"充油型电气设备排油孔、排气孔应(),不得有杂物。",[280,282,284],{"key":20,"text":281,"correct":22},"通畅",{"key":24,"text":283,"correct":26},"密封",{"key":28,"text":285,"correct":26},"流畅",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":28,"analysis":30},714708,"根据国家安全生产总局的要求,防爆电气作业是对()各种防爆电气设备进行安装、检修等作业。",[290,292,294],{"key":20,"text":291,"correct":26},"所有",{"key":24,"text":293,"correct":26},"煤矿中",{"key":28,"text":295,"correct":22},"除煤矿以外",{"id":297,"libraryId":5,"type":15,"typeLabel":16,"stem":298,"options":299,"answer":28,"analysis":30},714709,"爆炸危险环境电气配线导管通过楼板或地坪引入其他区域时,应在楼板或地坪的上方装设()式隔离密封件。",[300,302,304],{"key":20,"text":301,"correct":26},"单向",{"key":24,"text":303,"correct":26},"横向",{"key":28,"text":305,"correct":22},"纵向",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":20,"analysis":30},714710,"充油型电气设备应垂直安装,其倾斜度不应大于()。",[310,312,314],{"key":20,"text":311,"correct":22},"5°",{"key":24,"text":313,"correct":26},"3°",{"key":28,"text":315,"correct":26},"7°",{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":28,"analysis":30},714711,"浇封型电气设备的元件,如电阻、电容、其额定功率和额定电压不应超过电路额定值的()。",[320,322,324],{"key":20,"text":321,"correct":26},"1\u002F4",{"key":24,"text":323,"correct":26},"1\u002F2",{"key":28,"text":325,"correct":22},"2\u002F3",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":28,"analysis":30},714712,"外径等于或大于()mm的电缆,在隔离密封处组装防止电缆拔脱的组件时,应在电缆被拧紧或封固后,再拧紧固定电缆的螺栓。",[330,331,333],{"key":20,"text":25,"correct":26},{"key":24,"text":332,"correct":26},"15",{"key":28,"text":334,"correct":22},"20",{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":24,"analysis":30},714713,"通常情况下,防爆电气设备使用的环境温度应在规定的范围之内,如果超出这一范围就属特殊情况(标志应包括Ta或Tamb)应()规定使用环境温度",[339,341,343],{"key":20,"text":340,"correct":26},"产品使用厂家",{"key":24,"text":342,"correct":22},"由制造商规定",{"key":28,"text":344,"correct":26},"由有资质的防爆电气检测机构",{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":24,"analysis":30},714714,"防爆电气设备接线盒内,工作电压为380V裸露带电部分之间最小电气间隙应为()mm。",[349,350,351],{"key":20,"text":124,"correct":26},{"key":24,"text":29,"correct":22},{"key":28,"text":126,"correct":26},{"id":353,"libraryId":5,"type":15,"typeLabel":16,"stem":354,"options":355,"answer":24,"analysis":30},714715,"粉尘防爆电气设备安装应牢固,接线应正确,接触应良好,通风孔道()。",[356,358,360],{"key":20,"text":357,"correct":26},"应密封",{"key":24,"text":359,"correct":22},"不得堵塞",{"key":28,"text":361,"correct":26},"应关闭",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":24,"analysis":30},714716,"在爆炸危险场所维护检查设备时,严禁解除保护、联锁和()装置。",[366,368,370],{"key":20,"text":367,"correct":26},"开关",{"key":24,"text":369,"correct":22},"信号",{"key":28,"text":371,"correct":26},"清洗",{"id":373,"libraryId":5,"type":15,"typeLabel":16,"stem":374,"options":375,"answer":28,"analysis":30},714717,"“q”是()防爆型电气设备的防爆标志。",[376,378,380],{"key":20,"text":377,"correct":26},"浇封型",{"key":24,"text":379,"correct":26},"气压型",{"key":28,"text":381,"correct":22},"充砂型",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":24,"analysis":30},714718,"隔爆型防爆电气是最常用的防爆电气设备,其标志符是()。",[386,388,390],{"key":20,"text":387,"correct":26},"“O”",{"key":24,"text":389,"correct":22},"“d”",{"key":28,"text":391,"correct":26},"“p”",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":28,"analysis":30},714719,"爆炸性气体环境温度组别()的气体引燃温度最高。",[396,398,400],{"key":20,"text":397,"correct":26},"T0",{"key":24,"text":399,"correct":26},"T6",{"key":28,"text":401,"correct":22},"T1",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":24,"analysis":30},714720,"防爆灯具()应齐全,螺栓应紧固。",[406,408,410],{"key":20,"text":407,"correct":26},"装饰",{"key":24,"text":409,"correct":22},"外罩",{"key":28,"text":411,"correct":26},"保护",{"id":413,"libraryId":5,"type":15,"typeLabel":16,"stem":414,"options":415,"answer":28,"analysis":30},714721,"下列气体爆炸危险环境中使用的防爆电气不符合我国防爆电气标志的是()。",[416,418,420],{"key":20,"text":417,"correct":26},"Ex iaIICT5",{"key":24,"text":419,"correct":26},"Ex[ia] IIBT4",{"key":28,"text":421,"correct":22},"ExdBIIT5",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":20,"analysis":30},714722,"石油开采现场和精炼厂()属于爆炸性危险场所。",[426,428,430],{"key":20,"text":427,"correct":22},"60%--80%",{"key":24,"text":429,"correct":26},"55%--75%",{"key":28,"text":431,"correct":26},"65%—85%",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":28,"analysis":30},714723,"隔爆型防爆电气设备是一种()防爆技术。",[436,438,440],{"key":20,"text":437,"correct":26},"限能",{"key":24,"text":439,"correct":26},"隔离",{"key":28,"text":441,"correct":22},"间隙",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":24,"analysis":30},714724,"增安型电气设备,在正常运行时,下列说法不正确的是()。",[446,448,450],{"key":20,"text":447,"correct":26},"不会产生电弧",{"key":24,"text":449,"correct":22},"不会发生短路现象",{"key":28,"text":451,"correct":26},"不会产生火花",{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":454,"options":455,"answer":24,"analysis":30},714725,"充油型电气设备温度组别为T6的油面温度最高温升()℃。",[456,457,458],{"key":20,"text":261,"correct":26},{"key":24,"text":263,"correct":22},{"key":28,"text":265,"correct":26},{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":24,"analysis":30},714726,"正压型电气设备安装时应注意进入通风、充气系统及电气设备内的()应清洁,不得含有爆炸混合物及其他有害物质。",[463,465,467],{"key":20,"text":464,"correct":26},"绝缘油",{"key":24,"text":466,"correct":22},"空气或气体",{"key":28,"text":468,"correct":26},"绝缘漆",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":28,"analysis":30},714727,"对电气设备结构、材料、形状或功能的变动,称为()。",[473,475,477],{"key":20,"text":474,"correct":26},"修理合格证",{"key":24,"text":476,"correct":26},"修理标志",{"key":28,"text":478,"correct":22},"改造",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":24,"analysis":30},714728,"本安电路与非本安电路之间的绝缘能承受不小于()V的交流有效值试验电压。",[483,485,487],{"key":20,"text":484,"correct":26},"1000",{"key":24,"text":486,"correct":22},"1500",{"key":28,"text":488,"correct":26},"500",{"id":490,"libraryId":5,"type":15,"typeLabel":16,"stem":491,"options":492,"answer":20,"analysis":30},714729,"2区防爆电气设备在接线板上相邻端子间如果有()危险,每个导体的绝缘应连贯至端子金属近旁。",[493,495,497],{"key":20,"text":494,"correct":22},"短路",{"key":24,"text":496,"correct":26},"接地",{"key":28,"text":498,"correct":26},"接零",{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":24,"analysis":30},714730,"户外变、配电装置围墙高度一般不应小于()m。",[503,505,507],{"key":20,"text":504,"correct":26},"1.5",{"key":24,"text":506,"correct":22},"2.5",{"key":28,"text":508,"correct":26},"2.0",[510,513,516,518,521,524],{"id":511,"name":512,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":514,"name":515,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":517,"name":515,"category":7,"favorite":8},336,{"id":519,"name":520,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":522,"name":523,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":525,"name":526,"category":7,"favorite":8},353,"(N1)叉车司机"]