[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-388-5":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":506},{"id":5,"name":6,"category":7,"favorite":8},388,"防爆电气","特种作业",0,5,50,623,[13,28,38,48,58,70,80,90,100,110,119,129,139,149,157,167,177,187,197,207,217,224,234,244,254,263,273,283,293,302,312,322,332,342,352,362,371,381,391,399,409,419,429,439,449,459,468,477,487,496],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":23,"analysis":27},714631,1,"单选题","在爆炸性气体环境中,将气体按易爆炸危险程度划分为A、B、C三级,其中对电气设备要求最高的是()级气体。",[19,22,26],{"key":20,"text":20,"correct":21},"A",false,{"key":23,"text":24,"correct":25},"B","C",true,{"key":24,"text":23,"correct":21},"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":23,"analysis":27},714632,"某防爆电气接线盒的电缆接入口的管径是DN20(mm),从接口引入的电缆,允许的电缆直径范围应该是()。",[32,34,36],{"key":20,"text":33,"correct":21},"φ5-φ9",{"key":23,"text":35,"correct":25},"φ8-φ12",{"key":24,"text":37,"correct":21},"φ10-φ18",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":23,"analysis":27},714633,"正压外壳及管道内的所有空间的最小气体压力值应不低于()Mpa。",[42,44,46],{"key":20,"text":43,"correct":21},"100",{"key":23,"text":45,"correct":25},"50",{"key":24,"text":47,"correct":21},"200",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":20,"analysis":27},714634,"通至正压外壳内的保护气体是不燃、无毒性气体,不能采用()。",[52,54,56],{"key":20,"text":53,"correct":25},"助燃气体",{"key":23,"text":55,"correct":21},"新鲜空气",{"key":24,"text":57,"correct":21},"惰性气体",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":27},714635,"一种被划分为21区的可燃性非导电性粉尘,以下可选择的电气设备类型为()。",[62,64,66,68],{"key":20,"text":63,"correct":21},"Ⅰ类",{"key":23,"text":65,"correct":21},"Ⅱ",{"key":24,"text":67,"correct":25},"类",{"key":69,"text":67,"correct":21},"D",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":23,"analysis":27},714636,"运行中正压型电气设备内气压低于规定值时,()应可靠动作。",[74,76,78],{"key":20,"text":75,"correct":21},"高压继电器",{"key":23,"text":77,"correct":25},"微压继电器",{"key":24,"text":79,"correct":21},"低压继电器",{"id":81,"libraryId":5,"type":15,"typeLabel":16,"stem":82,"options":83,"answer":20,"analysis":27},714637,"爆炸危险性环境内的电气设备与接地线的连接,宜采用多股软绞线,其铜线最小截面面积不得小于()m㎡。",[84,86,88],{"key":20,"text":85,"correct":25},"4",{"key":23,"text":87,"correct":21},"2",{"key":24,"text":89,"correct":21},"6",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":20,"analysis":27},714638,"可燃性粉尘环境的电气设备转动轴与轴孔间的()密封应严密。",[94,96,98],{"key":20,"text":95,"correct":25},"防尘",{"key":23,"text":97,"correct":21},"防水",{"key":24,"text":99,"correct":21},"防油",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":23,"analysis":27},714639,"爆炸气体性环境电气配线导管与导管、导管与电气设备间须用螺纹连接,管径为25mm及以下的钢管不应少于()扣。",[104,106,108],{"key":20,"text":105,"correct":21},"3",{"key":23,"text":107,"correct":25},"5",{"key":24,"text":109,"correct":21},"7",{"id":111,"libraryId":5,"type":15,"typeLabel":16,"stem":112,"options":113,"answer":23,"analysis":27},714640,"室内变、配电装置额定电压为10kV时,带电体与网状遮栏之间的最小距离不应小于()mm。",[114,115,117],{"key":20,"text":43,"correct":21},{"key":23,"text":116,"correct":25},"225",{"key":24,"text":118,"correct":21},"180",{"id":120,"libraryId":5,"type":15,"typeLabel":16,"stem":121,"options":122,"answer":23,"analysis":27},714641,"建筑物内防雷电感应的接地干线与接地装置的连接不应少于()。",[123,125,127],{"key":20,"text":124,"correct":21},"一处",{"key":23,"text":126,"correct":25},"两处",{"key":24,"text":128,"correct":21},"三处",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":23,"analysis":27},714642,"低压配电装置正面通道双列布置时一般不应小于()m。",[133,135,137],{"key":20,"text":134,"correct":21},"1.5",{"key":23,"text":136,"correct":25},"2.0",{"key":24,"text":138,"correct":21},"2.5",{"id":140,"libraryId":5,"type":15,"typeLabel":16,"stem":141,"options":142,"answer":24,"analysis":27},714643,"使用电气设备时,由于维护不及时,当()进入时,可导致短路事故。",[143,145,147],{"key":20,"text":144,"correct":21},"热气",{"key":23,"text":146,"correct":21},"强光辐射",{"key":24,"text":148,"correct":25},"导电粉尘",{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":23,"analysis":27},714644,"防爆移动式电气设备至少()个月进行一次检查。",[153,154,156],{"key":20,"text":105,"correct":21},{"key":23,"text":155,"correct":25},"12",{"key":24,"text":89,"correct":21},{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":23,"analysis":27},714645,"分析表明,爆炸性气体(蒸气)的最大试验安全间隙越小,最小点燃电流越()。",[161,163,165],{"key":20,"text":162,"correct":21},"不变",{"key":23,"text":164,"correct":25},"小",{"key":24,"text":166,"correct":21},"大",{"id":168,"libraryId":5,"type":15,"typeLabel":16,"stem":169,"options":170,"answer":20,"analysis":27},714646,"可燃性粉尘环境中常需短距离移动的固定设备的导线若采用金属软管连接,则该软管()。",[171,173,175],{"key":20,"text":172,"correct":25},"必须接地",{"key":23,"text":174,"correct":21},"不能接地",{"key":24,"text":176,"correct":21},"允许不接地",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":23,"analysis":27},714647,"粉尘环境的电气设备()应无松动、锈蚀。",[181,183,185],{"key":20,"text":182,"correct":21},"开关",{"key":23,"text":184,"correct":25},"紧固螺栓",{"key":24,"text":186,"correct":21},"网罩",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":24,"analysis":27},714648,"触电现场,救护人员可用有绝缘胶柄的钳和有绝缘木柄的刀、斧等,将触电回路上的绝缘导线()。",[191,193,195],{"key":20,"text":192,"correct":21},"切除",{"key":23,"text":194,"correct":21},"挑开",{"key":24,"text":196,"correct":25},"切断",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":23,"analysis":27},714649,"隔爆型电气设备壳体有小的通孔,可以用()修补。",[201,203,205],{"key":20,"text":202,"correct":21},"硬钎焊",{"key":23,"text":204,"correct":25},"熔焊",{"key":24,"text":206,"correct":21},"粘补",{"id":208,"libraryId":5,"type":15,"typeLabel":16,"stem":209,"options":210,"answer":24,"analysis":27},714650,"防爆电气设备的防护等级是在选择设备时必须考虑的,设备在户外使用时如选择防户等级IP53,它违背了设备选择中()原则。",[211,213,215],{"key":20,"text":212,"correct":21},"可靠性",{"key":23,"text":214,"correct":21},"经济性",{"key":24,"text":216,"correct":25},"环境适应性",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":23,"analysis":27},714651,"隔爆型电气设备隔爆接合面上螺孔周围()mm范围的缺陷不可以进行修补。",[221,222,223],{"key":20,"text":87,"correct":21},{"key":23,"text":107,"correct":25},{"key":24,"text":105,"correct":21},{"id":225,"libraryId":5,"type":15,"typeLabel":16,"stem":226,"options":227,"answer":23,"analysis":27},714652,"爆炸危险环境电气线路选用的低压电缆或绝缘导线,额定电压必须()线路工作电压。",[228,230,232],{"key":20,"text":229,"correct":21},"等于",{"key":23,"text":231,"correct":25},"高于",{"key":24,"text":233,"correct":21},"低于",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":20,"analysis":27},714653,"防爆电气设备的安全检查和维护必须是专业的、带有强制性的()检查。",[238,240,242],{"key":20,"text":239,"correct":25},"行政性",{"key":23,"text":241,"correct":21},"组织性",{"key":24,"text":243,"correct":21},"法定性",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":23,"analysis":27},714654,"属于抗凝露器件的是()。",[248,250,252],{"key":20,"text":249,"correct":21},"外壳",{"key":23,"text":251,"correct":25},"呼吸元件",{"key":24,"text":253,"correct":21},"限能元件",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":23,"analysis":27},714655,"增安型电气设备在使用TT或TN系统时,优先选用动作电流30mA,动作时间在()秒以下。",[258,260,261],{"key":20,"text":259,"correct":21},"15",{"key":23,"text":107,"correct":25},{"key":24,"text":262,"correct":21},"10",{"id":264,"libraryId":5,"type":15,"typeLabel":16,"stem":265,"options":266,"answer":20,"analysis":27},714656,"()电气设备没有防爆的外壳和保护介质。",[267,269,271],{"key":20,"text":268,"correct":25},"增安型",{"key":23,"text":270,"correct":21},"隔爆型",{"key":24,"text":272,"correct":21},"本安型",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":24,"analysis":27},714657,"2区防爆电气设备不使用的电缆引入开口应(),以保证外壳的防护等级。",[277,279,281],{"key":20,"text":278,"correct":21},"检查",{"key":23,"text":280,"correct":21},"保护",{"key":24,"text":282,"correct":25},"堵塞",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":20,"analysis":27},714658,"下列在爆炸性危险气体环境中使用的电气设备,其防爆标志不符合规定的标注方法是()。",[287,289,291],{"key":20,"text":288,"correct":25},"Ex dIICT4",{"key":23,"text":290,"correct":21},"Ex dⅠ",{"key":24,"text":292,"correct":21},"Ex eⅠ\u002FIIBT5",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":20,"analysis":27},714659,"隔爆型电动机修理或更换风扇罩后,其防护等级应该满足()标准要求。",[297,299,300],{"key":20,"text":298,"correct":25},"防爆",{"key":23,"text":97,"correct":21},{"key":24,"text":301,"correct":21},"防火",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":20,"analysis":27},714660,"防爆电气设备要安装在牢固的金属支架上,有振动的电气设备的固定螺栓应有()。",[306,308,310],{"key":20,"text":307,"correct":25},"防松装置",{"key":23,"text":309,"correct":21},"支撑装置",{"key":24,"text":311,"correct":21},"反向装置",{"id":313,"libraryId":5,"type":15,"typeLabel":16,"stem":314,"options":315,"answer":23,"analysis":27},714661,"防爆电气的温度等级别划分中,III类电气设备T1、T3、T5组中,安全性最高的是()组",[316,318,320],{"key":20,"text":317,"correct":21},"T1",{"key":23,"text":319,"correct":25},"T5",{"key":24,"text":321,"correct":21},"T3",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":24,"analysis":27},714662,"防止切断电源时触电者在高处可能的摔伤,应先做好防摔措施,断电时要注意触电者的()方向。",[326,328,330],{"key":20,"text":327,"correct":21},"电流",{"key":23,"text":329,"correct":21},"身体",{"key":24,"text":331,"correct":25},"倒下",{"id":333,"libraryId":5,"type":15,"typeLabel":16,"stem":334,"options":335,"answer":20,"analysis":27},714663,"正压气体入口处的温度通常不超过()℃。",[336,338,340],{"key":20,"text":337,"correct":25},"40",{"key":23,"text":339,"correct":21},"20",{"key":24,"text":341,"correct":21},"60",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":24,"analysis":27},714664,"正压型电气防爆设备的正压外壳及其连接管道的防护等级应不低于()。",[346,348,350],{"key":20,"text":347,"correct":21},"IP30",{"key":23,"text":349,"correct":21},"IP50",{"key":24,"text":351,"correct":25},"IP40",{"id":353,"libraryId":5,"type":15,"typeLabel":16,"stem":354,"options":355,"answer":24,"analysis":27},714665,"增安型电气设备采取的防爆措施多数是在()的基础上提高质量的措施。",[356,358,360],{"key":20,"text":357,"correct":21},"普通产品",{"key":23,"text":359,"correct":21},"特殊产品",{"key":24,"text":361,"correct":25},"一般产品",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":24,"analysis":27},714666,"爆炸危险场所电力电缆与通讯、信号、仪表电缆应分开铺设,间距不宜小于()mm。",[366,367,369],{"key":20,"text":47,"correct":21},{"key":23,"text":368,"correct":21},"400",{"key":24,"text":370,"correct":25},"300",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":23,"analysis":27},714667,"物质呈现的()受材料和所含杂质成分、温度和湿度的影响。",[375,377,379],{"key":20,"text":376,"correct":21},"导电性",{"key":23,"text":378,"correct":25},"电性",{"key":24,"text":380,"correct":21},"电容性",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":20,"analysis":27},714668,"对本质安全型电气设备下列说法不正确的是()。",[385,387,389],{"key":20,"text":386,"correct":25},"内部大部分电路是本质安全电路",{"key":23,"text":388,"correct":21},"限制电路中能量",{"key":24,"text":390,"correct":21},"能限制热效应",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":20,"analysis":27},714669,"三相供电的防爆电气设备接线盒内接线端子间及其与金属外壳间的电气间隙不小于()mm。",[395,397,398],{"key":20,"text":396,"correct":25},"8",{"key":23,"text":89,"correct":21},{"key":24,"text":262,"correct":21},{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":24,"analysis":27},714670,"增湿是一种从()上消除静电危险的措施。",[403,405,407],{"key":20,"text":404,"correct":21},"方法",{"key":23,"text":406,"correct":21},"本质",{"key":24,"text":408,"correct":25},"工艺",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":24,"analysis":27},714671,"当隔爆型电气设备内部不包含点燃源时()采用弹性密封圈式的引入装置将电缆引入。",[413,415,417],{"key":20,"text":414,"correct":21},"不宜",{"key":23,"text":416,"correct":21},"不允许",{"key":24,"text":418,"correct":25},"允许",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":23,"analysis":27},714672,"无火花nA型电气设备对外壳防护等级要求是:内部具有裸露导体的外壳和接线盒防护不得低于()。",[423,425,427],{"key":20,"text":424,"correct":21},"IP44",{"key":23,"text":426,"correct":25},"IP54",{"key":24,"text":428,"correct":21},"IP46",{"id":430,"libraryId":5,"type":15,"typeLabel":16,"stem":431,"options":432,"answer":23,"analysis":27},714673,"当环境中存在两种以上可燃性气体时,应按()的气体选择温度组别。",[433,435,437],{"key":20,"text":434,"correct":21},"密度大",{"key":23,"text":436,"correct":25},"引燃温度低",{"key":24,"text":438,"correct":21},"引燃温度高",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":20,"analysis":27},714674,"粉尘防爆电气设备电缆引入装置的结构和固定不能损坏其所在电气设备的()。",[443,445,447],{"key":20,"text":444,"correct":25},"防爆特性",{"key":23,"text":446,"correct":21},"机械特性",{"key":24,"text":448,"correct":21},"化学特性",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":24,"analysis":27},714675,"具有导电性质的材料在()情况下能加强静电的泄放,减少静电的积累。",[453,455,457],{"key":20,"text":454,"correct":21},"杂质少",{"key":23,"text":456,"correct":21},"隔断",{"key":24,"text":458,"correct":25},"接地",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":23,"analysis":27},714676,"爆炸危险场所如果用IT型电源系统(中性线与地隔离或经阻抗接地),应提供一绝缘监视装置指示第1次()故障。",[463,465,466],{"key":20,"text":464,"correct":21},"短路",{"key":23,"text":458,"correct":25},{"key":24,"text":467,"correct":21},"接零",{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":24,"analysis":27},714677,"凡特别危险环境使用的携带式电动工具应采用()伏以下安全电压。",[472,473,475],{"key":20,"text":155,"correct":21},{"key":23,"text":474,"correct":21},"36",{"key":24,"text":476,"correct":25},"42",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":23,"analysis":27},714678,"对于IIC类本质安全型防爆电器,等级为i关联的设备,温度级别为T4.其防爆标志可标为()。",[481,483,485],{"key":20,"text":482,"correct":21},"Ex iaIICT4",{"key":23,"text":484,"correct":25},"Ex[ia] IICT4",{"key":24,"text":486,"correct":21},"Ex Iiict4",{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":20,"analysis":27},714679,"防爆设备引入装置密封圈的外径与腔室内径间隙不大于()mm。",[491,493,495],{"key":20,"text":492,"correct":25},"1",{"key":23,"text":494,"correct":21},"0.5",{"key":24,"text":105,"correct":21},{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":23,"analysis":27},714680,"防爆电气隔爆外壳接合面长期受到腐蚀作用而发生锈蚀,产品隔爆性能()。",[500,502,504],{"key":20,"text":501,"correct":21},"增强",{"key":23,"text":503,"correct":25},"降低甚至丧失",{"key":24,"text":505,"correct":21},"不变化",[507,510,513,515,518,521],{"id":508,"name":509,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":511,"name":512,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":514,"name":512,"category":7,"favorite":8},336,{"id":516,"name":517,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":519,"name":520,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":522,"name":523,"category":7,"favorite":8},353,"(N1)叉车司机"]