[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-388-2":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":509},{"id":5,"name":6,"category":7,"favorite":8},388,"防爆电气","特种作业",0,2,50,623,[13,31,41,51,61,71,81,91,101,111,121,131,141,151,161,171,179,189,199,209,219,229,239,248,258,268,278,288,298,306,316,326,336,346,356,366,376,386,396,404,414,424,434,443,452,462,472,482,492,502],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":30},714481,1,"单选题","如果采用衬垫或平面法兰连接,则应采用()的紧固螺栓、螺钉或采用其他型式的夹紧装置以保证法兰贴合在整个接合面上。",[19,23,27],{"key":20,"text":21,"correct":22},"A","足够数量",true,{"key":24,"text":25,"correct":26},"B","足够坚固",false,{"key":28,"text":29,"correct":26},"C","足够平直","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":20,"analysis":30},714482,"本安型系统必须可靠接地,如用铜芯导线作为接地导线,则其截面积不小于()mm。",[35,37,39],{"key":20,"text":36,"correct":22},"4",{"key":24,"text":38,"correct":26},"6",{"key":28,"text":40,"correct":26},"8",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":28,"analysis":30},714483,"粉尘防爆电气设备安装后应按()做好保护装置的调整和试操作。",[45,47,49],{"key":20,"text":46,"correct":26},"用户要求",{"key":24,"text":48,"correct":26},"现场使用",{"key":28,"text":50,"correct":22},"产品技术要求",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":28,"analysis":30},714484,"某面粉车间,其面粉最低燃点温度Tcl=360℃,当面粉堆积厚度达6mm时其最低燃点温度为290℃,当应选择A型设备时设备的温度组别应选择()。",[55,57,59],{"key":20,"text":56,"correct":26},"T2",{"key":24,"text":58,"correct":26},"T4",{"key":28,"text":60,"correct":22},"T3",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":28,"analysis":30},714485,"根据可燃性粉尘\u002F空气混合物环境出现的频率和持续时间及粉尘厚度,将可燃性粉尘环境划分为不同的区域,它们是()。",[65,67,69],{"key":20,"text":66,"correct":26},"0区、1区、2区",{"key":24,"text":68,"correct":26},"10区、11区、12区",{"key":28,"text":70,"correct":22},"20区、21区、22区",{"id":72,"libraryId":5,"type":15,"typeLabel":16,"stem":73,"options":74,"answer":24,"analysis":30},714486,"爆炸危险区内的非金属构架上的金属管道相互交叉的净距离小于()mm时,应采用金属线跨接。",[75,77,79],{"key":20,"text":76,"correct":26},"150",{"key":24,"text":78,"correct":22},"100",{"key":28,"text":80,"correct":26},"200",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":28,"analysis":30},714487,"长距离布线的外壳应有排放装置,电线绝缘应有()特性。",[85,87,89],{"key":20,"text":86,"correct":26},"防撞",{"key":24,"text":88,"correct":26},"防腐",{"key":28,"text":90,"correct":22},"防水",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":28,"analysis":30},714488,"CNEx是()防爆电气设备质量监督检测中心代号。",[95,97,99],{"key":20,"text":96,"correct":26},"中国南方",{"key":24,"text":98,"correct":26},"机械工业",{"key":28,"text":100,"correct":22},"中国国家",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":24,"analysis":30},714489,"正压型电气设备,通风充气系统的联锁装置,应按照先()后供电。",[105,107,109],{"key":20,"text":106,"correct":26},"供电",{"key":24,"text":108,"correct":22},"通风",{"key":28,"text":110,"correct":26},"停电",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":20,"analysis":30},714490,"电缆通过地坪、隔墙及易受机械损伤处,均应采用()钢管保护。",[115,117,119],{"key":20,"text":116,"correct":22},"厚壁型",{"key":24,"text":118,"correct":26},"薄壁型",{"key":28,"text":120,"correct":26},"密封型",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":20,"analysis":30},714491,"避雷器正常时处于()状态。",[125,127,129],{"key":20,"text":126,"correct":22},"不导通",{"key":24,"text":128,"correct":26},"导通",{"key":28,"text":130,"correct":26},"放大",{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":20,"analysis":30},714492,"螺纹连接应有适当()的螺纹以保证外壳能防止粉尘进入。",[135,137,139],{"key":20,"text":136,"correct":22},"数量",{"key":24,"text":138,"correct":26},"长度",{"key":28,"text":140,"correct":26},"深度",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":28,"analysis":30},714493,"防爆万用表在危险场所测量非本质安全电路时,首先必须确认电源()。",[145,147,149],{"key":20,"text":146,"correct":26},"正确接通",{"key":24,"text":148,"correct":26},"为安全电压",{"key":28,"text":150,"correct":22},"断开",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":24,"analysis":30},714494,"进入充油型电气设备的电缆(绝缘导线)的绝缘必须是()。",[155,157,159],{"key":20,"text":156,"correct":26},"耐高温型",{"key":24,"text":158,"correct":22},"耐油型",{"key":28,"text":160,"correct":26},"耐低温型",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":24,"analysis":30},714495,"会导致防爆电气性能下降的是()。",[165,167,169],{"key":20,"text":166,"correct":26},"保养维护",{"key":24,"text":168,"correct":22},"机械磨损",{"key":28,"text":170,"correct":26},"修理",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":28,"analysis":30},714496,"当爆炸危险区内的非金属构架上平行安装的金属管道相互之间的净距离小于()mm时,宜每隔20m用金属线跨接。",[175,177,178],{"key":20,"text":176,"correct":26},"50",{"key":24,"text":76,"correct":26},{"key":28,"text":78,"correct":22},{"id":180,"libraryId":5,"type":15,"typeLabel":16,"stem":181,"options":182,"answer":28,"analysis":30},714497,"工程上常利用最小点燃电压和最小点燃电流来判断电路的()。",[183,185,187],{"key":20,"text":184,"correct":26},"负荷",{"key":24,"text":186,"correct":26},"能量",{"key":28,"text":188,"correct":22},"安全性能",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":24,"analysis":30},714498,"Ex[ia]ⅡCT5表示本质安全型的()。",[193,195,197],{"key":20,"text":194,"correct":26},"外壳",{"key":24,"text":196,"correct":22},"关联设备",{"key":28,"text":198,"correct":26},"专门设备",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":28,"analysis":30},714499,"正常运行时产生火花或电弧的隔爆型电气设备,必须设置()装置,保证安全。",[203,205,207],{"key":20,"text":204,"correct":26},"机械互锁",{"key":24,"text":206,"correct":26},"机械联锁",{"key":28,"text":208,"correct":22},"电气联锁",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":28,"analysis":30},714500,"()视实际情况需要随时进行。",[213,215,217],{"key":20,"text":214,"correct":26},"送厂检修",{"key":24,"text":216,"correct":26},"专业性检修",{"key":28,"text":218,"correct":22},"一般性检修",{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":221,"options":222,"answer":28,"analysis":30},714501,"在低压操作中,人体及其所携带工具与带电体的距离不应小于()m。",[223,225,227],{"key":20,"text":224,"correct":26},"0.3",{"key":24,"text":226,"correct":26},"0.2",{"key":28,"text":228,"correct":22},"0.1",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":20,"analysis":30},714502,"绝缘夹钳用于()的电气操作。",[233,235,237],{"key":20,"text":234,"correct":22},"35kV及以下",{"key":24,"text":236,"correct":26},"35kV以上",{"key":28,"text":238,"correct":26},"110kV",{"id":240,"libraryId":5,"type":15,"typeLabel":16,"stem":241,"options":242,"answer":28,"analysis":30},714503,"所有正压管道和连接件应能承受()倍的最大正常压力。",[243,244,246],{"key":20,"text":36,"correct":26},{"key":24,"text":245,"correct":26},"2",{"key":28,"text":247,"correct":22},"1.5",{"id":249,"libraryId":5,"type":15,"typeLabel":16,"stem":250,"options":251,"answer":20,"analysis":30},714504,"不得用()直接冲洗防爆电气设备。",[252,254,256],{"key":20,"text":253,"correct":22},"带压力的水",{"key":24,"text":255,"correct":26},"自来水",{"key":28,"text":257,"correct":26},"专用清洗液",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":28,"analysis":30},714505,"爬电距离是指两个导电部分之间沿绝缘材料表面的()。",[262,264,266],{"key":20,"text":263,"correct":26},"平均距离",{"key":24,"text":265,"correct":26},"最长距离",{"key":28,"text":267,"correct":22},"最短距离",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":20,"analysis":30},714506,"绝缘、屏护、间距是防止()接触电击的基本防护措施。",[272,274,276],{"key":20,"text":273,"correct":22},"直接",{"key":24,"text":275,"correct":26},"管理",{"key":28,"text":277,"correct":26},"间接",{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":280,"options":281,"answer":24,"analysis":30},714507,"我国对防爆电气设备实行()管理和认证。",[282,284,286],{"key":20,"text":283,"correct":26},"推荐性",{"key":24,"text":285,"correct":22},"强制",{"key":28,"text":287,"correct":26},"封闭",{"id":289,"libraryId":5,"type":15,"typeLabel":16,"stem":290,"options":291,"answer":24,"analysis":30},714508,"防爆电气设备安装后冗余电缆引入口没有按规定使用()封堵是错误的。",[292,294,296],{"key":20,"text":293,"correct":26},"弹性橡胶",{"key":24,"text":295,"correct":22},"金属堵板",{"key":28,"text":297,"correct":26},"密封胶圈",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":28,"analysis":30},714509,"爆炸危险场所中接地干线宜在不同方向与接地体相连,连接处不得少于()处。",[302,304,305],{"key":20,"text":303,"correct":26},"1",{"key":24,"text":36,"correct":26},{"key":28,"text":245,"correct":22},{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":24,"analysis":30},714510,"防爆电气设备非金属外壳为避免产生引燃危险的静电,表面电阻不大于()。",[310,312,314],{"key":20,"text":311,"correct":26},"7MΩ",{"key":24,"text":313,"correct":22},"1GΩ",{"key":28,"text":315,"correct":26},"1MΩ",{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":28,"analysis":30},714511,"防爆电气都有一个合格证。我国的防爆合格证主要由四个部分组成,并有一串数字,其中从左边数起,第一项代表()。",[320,322,324],{"key":20,"text":321,"correct":26},"防爆证代号",{"key":24,"text":323,"correct":26},"该年度的防爆合格证号",{"key":28,"text":325,"correct":22},"年代号",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":20,"analysis":30},714512,"低压验电器的测量范围是()伏。",[330,332,334],{"key":20,"text":331,"correct":22},"60至500",{"key":24,"text":333,"correct":26},"60至380",{"key":28,"text":335,"correct":26},"36至220",{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":24,"analysis":30},714513,"可燃粉尘危险区域22区划分条件之一是()可燃性粉尘云偶尔出现并且只是短时间存在。",[340,342,344],{"key":20,"text":341,"correct":26},"在正常情况下",{"key":24,"text":343,"correct":22},"在异常情况下",{"key":28,"text":345,"correct":26},"在正常或异常情况下",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":24,"analysis":30},714514,"充砂型电气设备属于()进行防爆。",[350,352,354],{"key":20,"text":351,"correct":26},"用外壳限制爆炸",{"key":24,"text":353,"correct":22},"用介质隔离",{"key":28,"text":355,"correct":26},"减小火花",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":20,"analysis":30},714515,"隔爆型电气设备在气体检测器上用于接合面保护材料要保证其()。",[360,362,364],{"key":20,"text":361,"correct":22},"非凝固性",{"key":24,"text":363,"correct":26},"凝固性",{"key":28,"text":365,"correct":26},"易干燥",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":28,"analysis":30},714516,"在同一区域内若同时存在两种以上不同危险等级的爆炸性气体时,必须选择()的爆炸等级以及点燃温度等级相适应的防爆结构的防爆电气设备。",[370,372,374],{"key":20,"text":371,"correct":26},"综合考虑气体混合物",{"key":24,"text":373,"correct":26},"气体混合物",{"key":28,"text":375,"correct":22},"危险度最高一种",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":20,"analysis":30},714517,"对使用中的防爆电气设备的防爆性能检查,检查周期为()1次。",[380,382,384],{"key":20,"text":381,"correct":22},"每月",{"key":24,"text":383,"correct":26},"每周",{"key":28,"text":385,"correct":26},"每年",{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":20,"analysis":30},714518,"在可燃性粉尘环境,选择电气设备可按照粉尘类型和区域来选择,下列选项标识正确的是()。",[390,392,394],{"key":20,"text":391,"correct":22},"DIP A21 TA",{"key":24,"text":393,"correct":26},"DIP B20",{"key":28,"text":395,"correct":26},"DIP B22",{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":28,"analysis":30},714519,"爆炸气体性环境电气配线导管通过墙、楼板、地坪时,隔离密封件与墙面、楼板、地坪的距离不应超过()mm。",[400,401,402],{"key":20,"text":78,"correct":26},{"key":24,"text":80,"correct":26},{"key":28,"text":403,"correct":22},"300",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":20,"analysis":30},714520,"为防止因电气设备发热导致爆炸性环境引爆,应确保设备的最高表面温度()设备可能接触到的气体的引燃温度。",[408,410,412],{"key":20,"text":409,"correct":22},"不超过",{"key":24,"text":411,"correct":26},"超过",{"key":28,"text":413,"correct":26},"高于",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":28,"analysis":30},714521,"爆炸危险场所1区应采用()电缆。",[418,420,422],{"key":20,"text":419,"correct":26},"绝缘",{"key":24,"text":421,"correct":26},"铠装",{"key":28,"text":423,"correct":22},"铠装铜芯",{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":24,"analysis":30},714522,"齐纳二极管就是()二极管。",[428,430,432],{"key":20,"text":429,"correct":26},"开关",{"key":24,"text":431,"correct":22},"稳压",{"key":28,"text":433,"correct":26},"整流",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":28,"analysis":30},714523,"n型电气设备是一种正常运行时,不会引起点燃的火花,或超过温度组别限制的最高表面温度的电气设备,它有()种防爆型式。",[438,440,441],{"key":20,"text":439,"correct":26},"3",{"key":24,"text":36,"correct":26},{"key":28,"text":442,"correct":22},"5",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":28,"analysis":30},714524,"引入、引出建筑物的金属管道,在进出入处应与防雷的接地装置相连;对架空金属管道还应在距建筑物约25m处接地一次,其接地电阻不应大于()Ω。",[447,448,450],{"key":20,"text":176,"correct":26},{"key":24,"text":449,"correct":26},"30",{"key":28,"text":451,"correct":22},"10",{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":454,"options":455,"answer":20,"analysis":30},714525,"在爆炸危险场所使用的本质安全设备(除独立电源)都必须外接()。",[456,458,460],{"key":20,"text":457,"correct":22},"安全栅",{"key":24,"text":459,"correct":26},"限流器",{"key":28,"text":461,"correct":26},"断路器",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":28,"analysis":30},714526,"防爆电器设备电缆引入口,应有密封措施,为确保安全要采用()。",[466,468,470],{"key":20,"text":467,"correct":26},"软塑料垫圈",{"key":24,"text":469,"correct":26},"石棉垫",{"key":28,"text":471,"correct":22},"弹性密封圈",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":28,"analysis":30},714527,"高压验电器的试验周期为()。",[476,478,480],{"key":20,"text":477,"correct":26},"2年",{"key":24,"text":479,"correct":26},"1年",{"key":28,"text":481,"correct":22},"6个月",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":24,"analysis":30},714528,"在爆炸危险场所使用的扳手、钳子等工具,必须为()材料制造。",[486,488,490],{"key":20,"text":487,"correct":26},"防爆",{"key":24,"text":489,"correct":22},"无火花",{"key":28,"text":491,"correct":26},"阻燃",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":24,"analysis":30},714529,"隔爆型电气设备插销防止骤然拔脱的(),应完好可靠不得松脱。",[496,498,500],{"key":20,"text":497,"correct":26},"护罩",{"key":24,"text":499,"correct":22},"徐动装置",{"key":28,"text":501,"correct":26},"外盖",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":20,"analysis":30},714530,"防爆电气设备,电缆进线装置,应使用厚度不小于()mm的钢板密封。",[506,507,508],{"key":20,"text":245,"correct":22},{"key":24,"text":303,"correct":26},{"key":28,"text":439,"correct":26},[510,513,516,518,521,524],{"id":511,"name":512,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":514,"name":515,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":517,"name":515,"category":7,"favorite":8},336,{"id":519,"name":520,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":522,"name":523,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":525,"name":526,"category":7,"favorite":8},353,"(N1)叉车司机"]