[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-388-13":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":160},{"id":5,"name":6,"category":7,"favorite":8},388,"防爆电气","特种作业",0,13,50,623,[13,28,34,40,46,52,58,64,70,76,82,88,94,100,106,112,118,124,130,136,142,148,154],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":21,"analysis":27},715031,3,"判断题","爆炸危险场所,按爆炸物质的物态分为气体爆炸危险场所和可燃性粉尘危险场所两大类。",[19,23],{"key":20,"text":21,"correct":22},"A","正确",true,{"key":24,"text":25,"correct":26},"B","错误",false,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":25,"analysis":27},715032,"隔爆型电气设备隔爆接合面上螺孔周围5.0mm范围的缺陷可以进行修补。",[32,33],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":21,"analysis":27},715033,"增安型电气设备型号、规格应符合设计要求。",[38,39],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":25,"analysis":27},715034,"进入爆炸危险场所的电源零线和地线可以共用。",[44,45],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":21,"analysis":27},715035,"更换防爆、电气设备的元件,零部件等,其尺寸、型号、材质必须和原件一样。",[50,51],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":25,"analysis":27},715036,"正压型电气防爆设备的正压外壳的排气口应连到安全环境,如果采取有效的措施阻止炽热颗粒吹出,排气口也可放到0区的地方。",[56,57],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":25,"analysis":27},715037,"增安型电气设备接线盒内接线端子损坏,应该用与原来的零件不相同的备件更换。",[62,63],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":25,"analysis":27},715038,"粉尘型电气设备不允许有粉尘堆积。",[68,69],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":25,"analysis":27},715039,"爆炸性气体环境1区、2区手提式和移动式设备,若电缆使用金属柔韧性铠装或屏蔽,则铠装或屏蔽可单独作为保护导线使用。",[74,75],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":25,"analysis":27},715040,"防爆电气设备密封圈和压紧元件之间的金属垫圈安装时可以不要。",[80,81],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":21,"analysis":27},715041,"火灾爆炸危险场所必须具有更加完善的防雷和防静电措施。",[86,87],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":21,"analysis":27},715042,"爆炸气体性环境电气配线钢管与隔爆型设备间须用螺纹连接,螺纹连接处应有锁紧螺母。",[92,93],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":21,"analysis":27},715043,"在爆炸危险场所划分时,除依据危险区域划分的定义之外还应考虑其它相关因素。如根据危险区域的通风状况的好坏,可降低或提高危险区域的等级。",[98,99],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":21,"analysis":27},715044,"2区防爆电气设备如果多根导线同时引入一个端子,应确保每根导线都可靠夹紧。",[104,105],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":21,"analysis":27},715045,"在正常运行过程中,可能出现粉尘数量足以形成可燃性粉尘与空气混合物,但这种场所又未被划为20区,这样的场所将其划分为21区。",[110,111],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":25,"analysis":27},715046,"在爆炸危险场所内,可采用绝缘导线明敷。",[116,117],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":21,"analysis":27},715047,"隔爆型电气设备隔爆接合面的紧固螺丝不得任意更换,弹簧垫圈应齐全。",[122,123],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":25,"analysis":27},715048,"n型电气设备中的无火花型设备的第一类,其标志为ExnL。",[128,129],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":25,"analysis":27},715049,"在爆炸性气体和蒸气危险区域范围划分过程中,如果环境通风力度减小,则危险区域的范围也可缩小。",[134,135],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":25,"analysis":27},715050,"防爆电气设备安装接线盒应直接用电线管旋入。",[140,141],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":21,"analysis":27},715051,"在爆炸危险场所电气安装的设计和运行中,应考虑静电、雷电作用、电磁辐射等所造成的影响。",[146,147],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":25,"analysis":27},715052,"如果容器形状复杂,爆炸性混合物爆炸时产生的最大压力会减小。",[152,153],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":21,"analysis":27},715053,"无火花型电气设备的安全性要低于增安型设备。",[158,159],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},[161,165,168,170,173,176],{"id":162,"name":163,"category":7,"favorite":164},401,"高处安装、维护、拆除",1,{"id":166,"name":167,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":169,"name":167,"category":7,"favorite":8},336,{"id":171,"name":172,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":174,"name":175,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":177,"name":178,"category":7,"favorite":8},353,"(N1)叉车司机"]