[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-388-11":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":322},{"id":5,"name":6,"category":7,"favorite":8},388,"防爆电气","特种作业",0,11,50,623,[13,28,34,40,46,52,58,64,70,76,82,88,94,100,106,112,118,124,130,136,142,148,154,160,166,172,178,184,190,196,202,208,214,220,226,232,238,244,250,256,262,268,274,280,286,292,298,304,310,316],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":25,"analysis":27},714931,3,"判断题","在爆炸危险场所难以避免中间接头时,可在防爆接线盒内连接,接线盒应埋地(墙)。",[19,23],{"key":20,"text":21,"correct":22},"A","正确",false,{"key":24,"text":25,"correct":26},"B","错误",true,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":25,"analysis":27},714932,"防爆电气设备密封圈的单孔内可以穿进多根电缆,不会失爆。",[32,33],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":25,"analysis":27},714933,"间距是将可能触及的带电体置于可能触及的范围内。",[38,39],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":25,"analysis":27},714934,"为了提高本安型系统的接地可靠性,应该在该系统实行多点接地。",[44,45],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":25,"analysis":27},714935,"由于要考虑温度引起的点燃,将粉尘按其引燃温度划分级别,与爆炸性气体环境分组不同。",[50,51],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":25,"analysis":27},714936,"供压设备,如风机和压缩机保护气体入口,安装区域无特殊安全要求。",[56,57],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":25,"analysis":27},714937,"当防爆电气设备的检修费用大于或接近购置同型设备费用的80%以上时,应当报废更新。",[62,63],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":25,"analysis":27},714938,"粉尘防爆型电气设备根据其制造原理及工艺技术,必须完全阻止粉尘进入电气外壳内,只有这样才能确保安全。",[68,69],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":21,"analysis":27},714939,"充油型电气设备外壳应无裂纹、无损伤。",[74,75],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":25,"analysis":27},714940,"爆炸危险场所工作零线必须接在设备的接线端子上,也可接在外壳接地端子上(或内接地螺栓上)。",[80,81],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":25,"analysis":27},714941,"选择可燃爆炸性气体气环境用设备时,在了解清楚了爆炸性气体引燃温度和浓度时就可以根据GB3836.15—2000和GB50058—1992来选择设备了。",[86,87],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":21,"analysis":27},714942,"外壳防护的补充字母“W”表示在特定气候条件下使用。",[92,93],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":21,"analysis":27},714943,"现场发现有人触电后,应立即通知医院派救护车来抢救,即使触电者神志清醒也应立即送医院检查。",[98,99],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":21,"analysis":27},714944,"nL型电气设备温度组别由电路、元器件甚至导线表面温度确认。",[104,105],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":25,"analysis":27},714945,"增安型电气间隙和爬电距离比一般电气产品要小。",[110,111],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":21,"analysis":27},714946,"防止触电的安全用具的试验包括耐压试验和泄漏电流试验。",[116,117],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":25,"analysis":27},714947,"增安型电气设备是指在任何运行条件下都不会产生危险温度、电弧、火花的电气设备,其防爆标志是“e”。",[122,123],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":21,"analysis":27},714948,"隔爆型电气设备安装时应防止损伤隔爆面。",[128,129],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":21,"analysis":27},714949,"粉尘防爆型电气设备有两个特点:一是外壳具有较高的密封性,以减少或阻止粉尘进入外壳内,二是控制外壳表面最高允许温度,不超过规定的温度组别。",[134,135],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":21,"analysis":27},714950,"用于0区的防爆电气设备可用于1区,用于0区和1区的设备可用于2区。",[140,141],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":25,"analysis":27},714951,"防爆合格证书编号后缀有“U”符号的产品可以直接与其他电气设备或系统一起使用,无需进行附件认证。",[146,147],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":25,"analysis":27},714952,"在危险爆炸性气体环境中,IIA、IIB、IIC级气体危险程度的顺序是IIA&gt;IIB&gt;IIC,所以,标志为IIA类设备可以适用于标志IIB类设备环境中。",[152,153],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":25,"analysis":27},714953,"隔爆型电气设备的外壳一般采用塑料材质制成。",[158,159],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":25,"analysis":27},714954,"在爆炸危险场所,防爆电机可以频繁启动。",[164,165],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":21,"analysis":27},714955,"在爆炸危险场所使用的本质安全设备(除独立电源)都必须外接关联设备。",[170,171],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":21,"analysis":27},714956,"防爆数字万用表的防爆类型一般为本安型。",[176,177],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":21,"analysis":27},714957,"任何时候,如果危险场所的分类有了改变或电气设备位置发生变化,都应进行检查,以确保其防爆型式。",[182,183],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":25,"analysis":27},714958,"粉尘环境电气设备外壳上不装电缆或导管引入装置时,其通孔堵封件不用工具应可拆除。",[188,189],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":21,"analysis":27},714959,"正压型电气设备外壳或通风管道及其密封垫损坏需更换或修理,可以用一般工业的修理工艺修理,但应该保证设备和管道的气密性。",[194,195],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":21,"analysis":27},714960,"可燃性粉尘的爆炸极限是以在混合物中所占体积的质量比来表示的。",[200,201],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":21,"analysis":27},714961,"n型电动机的外风扇或风扇罩损坏需要更换或修理,其要求与隔爆型电动机相同。",[206,207],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":25,"analysis":27},714962,"隔爆型电气设备的外壳材料一般采用金属材料制成,但当外壳容积不大于0.8L时,也可用塑料材料来制作。",[212,213],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":25,"analysis":27},714963,"正压型防爆电器的主要技术措施是用空气和惰气来换气,当内部压力高于规定值时就切断主电源。",[218,219],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":21,"analysis":27},714964,"粉尘防爆电气设备的防爆标志、外壳防护等级和温度组别,应与爆炸性粉尘环境相适应。",[224,225],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":21,"analysis":27},714965,"本质安全型及关联设备电路之间的配线,应按钢管配线或电缆配线要求单独敷设。",[230,231],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":25,"analysis":27},714966,"隔爆型电气设备插销安装要求应在开关闭合时,插头可插入或拔脱。",[236,237],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":25,"analysis":27},714967,"在爆炸危险场所使用工具时,确认断电的情况下,可使用非防爆型工具进行检修。",[242,243],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":25,"analysis":27},714968,"爆炸危险性环境设备、机组、贮罐、管道等的防静电接地线可以互相串连接地。",[248,249],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":21,"analysis":27},714969,"发生触电时,如果电源开关或插头就在附近,应立即断开开关或拔掉插头。",[254,255],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":25,"analysis":27},714970,"爆炸危险场所的划分主要是按爆炸物质出现的频繁程度和持续时间为依据,对粉尘还要考虑粉尘浓度。",[260,261],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":25,"analysis":27},714971,"化学工业中70%以上生产车间属于爆炸危险场所。",[266,267],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":21,"analysis":27},714972,"所有接地必须牢固可靠,并利于例行检查。",[272,273],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":21,"analysis":27},714973,"在爆炸危险场所需要动火检修的防爆电气设备,必须办理动火审批手续。",[278,279],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":21,"analysis":27},714974,"所有的电气设备、系统和装置在投入运行前应对它们进行初始检查。",[284,285],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":21,"analysis":27},714975,"充油型电气设备安装前应检查型号、规格应符合设计要求。",[290,291],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":25,"analysis":27},714976,"最小点燃电流就是指在任何情况下能点燃混合物的最小电流值。",[296,297],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":21,"analysis":27},714977,"隔爆型电气设备插销安装要求应在插头插入时,接地或接零触头先接通;插头拔出时,主触头应先分断。",[302,303],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":21,"analysis":27},714978,"静电是在宏观范围内暂时推动平衡的相对静止的正电荷和负电荷。",[308,309],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":21,"analysis":27},714979,"防爆标志是防爆电气设备所适用爆炸危险场所的代号,通常用三个参量来定义,这些参数可在设备铭牌上找到。",[314,315],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":21,"analysis":27},714980,"充砂型电气设备都是一种外壳内充填沙粒,使之在规定的使用条件下不能点燃周围爆炸性混合物的设备。",[320,321],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},[323,327,330,332,335,338],{"id":324,"name":325,"category":7,"favorite":326},401,"高处安装、维护、拆除",1,{"id":328,"name":329,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":331,"name":329,"category":7,"favorite":8},336,{"id":333,"name":334,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":336,"name":337,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":339,"name":340,"category":7,"favorite":8},353,"(N1)叉车司机"]