[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-385-24":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":322},{"id":5,"name":6,"category":7,"favorite":8},385,"电气试验","特种作业",0,24,50,1221,[13,28,34,40,46,52,58,64,70,76,82,88,94,100,106,112,118,124,130,136,142,148,154,160,166,172,178,184,190,196,202,208,214,220,226,232,238,244,250,256,262,268,274,280,286,292,298,304,310,316],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":21,"analysis":27},714360,3,"判断题","冲击耐压试验所施加的试验电压是一个持续时间很短的冲击波。",[19,23],{"key":20,"text":21,"correct":22},"A","正确",true,{"key":24,"text":25,"correct":26},"B","错误",false,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":21,"analysis":27},714361,"介质损耗角正切值通常简称“介质损失”,记作“tanδ”。",[32,33],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":21,"analysis":27},714362,"当绝缘介质一定,外加电压一定时,介质损耗电流IR的大小与介质损耗正切值tanδ成正比。",[38,39],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":21,"analysis":27},714363,"牌号为DB-25的变压器油可用于气温不低于-20℃的地区作为户外断路器、油浸电容式套管和互感器用油。",[44,45],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":25,"analysis":27},714364,"在不均匀电场中,直流击穿电压与工频击穿电压的幅值接近相等。",[50,51],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":25,"analysis":27},714365,"阳极流注的方向与初始电子崩的方向相同。",[56,57],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":21,"analysis":27},714366,"判断导体内的感应电动势的方向时,应使用右手定则。",[62,63],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":21,"analysis":27},714367,"通常采用绝缘摇表来测量电气设备的绝缘电阻。",[68,69],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":21,"analysis":27},714368,"电气设备在进行大修后,或者在进行局部改造后,要进行检修后试验,试验应执行电力行业标准《电气设备预防性试验规程》中规定的大修、小修试验项目和试验合格标准。",[74,75],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":21,"analysis":27},714369,"衡量电流大小、强弱的物理量称为电流强度,用I表示。",[80,81],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":21,"analysis":27},714370,"高压试验中,绝缘试验可分为非破坏性试验和破坏性试验。",[86,87],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":25,"analysis":27},714371,"新安装电气设备在安装竣工后,交接验收时必须进行频率测试。",[92,93],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":25,"analysis":27},714372,"感抗XL与线圈的电感L和交流电频率f成反比。",[98,99],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":21,"analysis":27},714373,"真空的磁导率为4p×10-7H\u002Fm。",[104,105],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":21,"analysis":27},714374,"进行绝缘试验时,户外试验应在良好的天气进行,且空气相对湿度一般不高于80%。",[110,111],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":21,"analysis":27},714375,"电气设备停电试验应完成保证安全的组织措施和技术措施,严格执行《电业安全工作规程》的有关规定。",[116,117],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":25,"analysis":27},714376,"工作票是准许在电气设备上工作的书面命令,是执行保证安全技术措施的书面依据,一般有三种格式。",[122,123],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":21,"analysis":27},714377,"电阻的倒数称为电导,电阻越大,电导越小。",[128,129],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":21,"analysis":27},714378,"在电路中,导线把电流从电源引出,通过负载再送回电源,构成电流的完整回路。",[134,135],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":25,"analysis":27},714379,"对不便拆解分别作试验的设备进行试验时,试验标准应采用连接的各种设备中的最高标准。",[140,141],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":21,"analysis":27},714380,"工频耐压试验时,高压输入端存在“容升”现象,试验电压的测量一般采取高压直接测量。",[146,147],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":21,"analysis":27},714381,"人工合成绝缘油多用于高压电容器作为浸渍剂。",[152,153],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":21,"analysis":27},714382,"电动势表征电源中外力将非电形式的能量转变为电能时做功的能力。",[158,159],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":21,"analysis":27},714383,"根据试验项目内容的不同,高压试验分为特性试验和绝缘试验。",[164,165],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":21,"analysis":27},714384,"右手螺旋定则可以用已知电流方向来判断他所产生的磁场方向,也可以用已知磁场的方向来判断产生磁场的电流方向。",[170,171],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":25,"analysis":27},714385,"电阻的单位是欧姆,符号表示为小写W。",[176,177],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":21,"analysis":27},714386,"改善电场均匀度能显著提高油间隙的冲击击穿电压。",[182,183],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":21,"analysis":27},714387,"电气设备在投入电力系统运行后,由于电压、电流、温度、湿度等多种因素的作用,电气设备中的薄弱部位可能产生潜伏性缺陷。",[188,189],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":21,"analysis":27},714388,"采用直流压降法进行直流电阻测试,如电路连接时采用被测电阻与电流表串联后再与电压表并联,则该方法适用于测量大电阻。",[194,195],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":21,"analysis":27},714389,"介质损耗角正切值tanδ对局部集中缺陷不太灵敏时,一般将设备进行分解试验。",[200,201],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":21,"analysis":27},714390,"作为代用设备,电力设备的额定电压高于实际使用的工作电压,所采用的试验电压值应按照实际使用的额定工作电压来确定。",[206,207],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":21,"analysis":27},714391,"对油浸式变压器等充油设备,应以被试物上层油温作为测试温度。",[212,213],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":25,"analysis":27},714392,"工频耐压试验时,流过被试品的电流一般为μA级。",[218,219],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":21,"analysis":27},714393,"通过接地极流入大地的电流为冲击电流,在接地装置上的对地电压与通过接地极流入地中电流的比值称为冲击接地电阻。",[224,225],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":21,"analysis":27},714394,"液体介质的击穿过程与所含的杂质如气泡、水滴或纤维等密切相关。",[230,231],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":21,"analysis":27},714395,"电力系统的架空线路和电气设备的外绝缘一般采用大气作为绝缘间隙,并不处于真空,因此不会出现辉光放电。",[236,237],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":21,"analysis":27},714396,"典型雷电冲击电压波形由0.3Um和0.9Um两点连一直线与波峰的水平线以及横坐标的交点在横轴上的投影长度T1作为波前时间。",[242,243],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":21,"analysis":27},714397,"工频耐压试验采用电容分压器直接测量高压侧试验电压的原理是:串联电容C1、C2上的电压分配与电容量成反比。",[248,249],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":21,"analysis":27},714398,"对极不均匀电场工频击穿电压,当极间距离相同时,棒-板间隙的击穿电压要低于棒-棒间隙的击穿电压。",[254,255],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":21,"analysis":27},714399,"直流电压波纹系数也称为直流电压的脉动因数,是指电压脉动幅值对电压最大值与最小值算术平均值的周期性波动。",[260,261],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":25,"analysis":27},714400,"当直流电压加到被试品上时,绝缘介质内部或表面的带电粒子作定向移动形成的电流称为吸收电流。",[266,267],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":21,"analysis":27},714401,"牌号为DB-10的变压器油可用于气温不低于-50C的地区作为户外断路器、油浸电容式套管和互感器用油。",[272,273],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":21,"analysis":27},714402,"与架空线直接连接的旋转电机进线段上避雷器的接地电阻,应符合的要求为不大于3Ω。",[278,279],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":21,"analysis":27},714403,"移圈式调压器的优点是容量大,电压可做的较高。",[284,285],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":25,"analysis":27},714404,"含有气体的液体介质,其冲击击穿电压与压力有直接关系。",[290,291],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":21,"analysis":27},714405,"预防性试验是指对已投入运行的电气设备,为了及时发现运行中设备的隐患,预防发生事故或设备损坏,对设备进行的试验或检测。",[296,297],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":21,"analysis":27},714406,"电源电动势的电功率表示电源电动势E与通过电源电流I的乘积,即P=EI。",[302,303],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":21,"analysis":27},714407,"IEC和我国国家标准规定,操作冲击电压波形的波前时间为T1=250μs,容许偏差+20%。",[308,309],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":21,"analysis":27},714408,"在外电场的作用下,原子中的电子运行轨道发生了变形位移,电子负电荷的作用中心与原子核的正电荷不再重合,形成电矩。",[314,315],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":21,"analysis":27},714409,"虽然电场不均匀,但还不能维持稳定的电晕放电,一旦达到自持,必然会导致整个间隙立即击穿的电场称为稍不均匀电场。",[320,321],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},[323,327,330,332,335,338],{"id":324,"name":325,"category":7,"favorite":326},401,"高处安装、维护、拆除",1,{"id":328,"name":329,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":331,"name":329,"category":7,"favorite":8},336,{"id":333,"name":334,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":336,"name":337,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":339,"name":340,"category":7,"favorite":8},353,"(N1)叉车司机"]