[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-385-12":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":336},{"id":5,"name":6,"category":7,"favorite":8},385,"电气试验","特种作业",0,12,50,1221,[13,34,44,54,60,66,72,78,84,90,96,102,108,114,120,126,132,138,144,150,156,162,168,174,180,186,192,198,204,210,216,222,228,234,240,246,252,258,264,270,276,282,288,294,300,306,312,318,324,330],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},713760,1,"单选题","进行绝缘试验时,被试品温度不应低于()。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","0℃",false,{"key":24,"text":25,"correct":26},"B","5℃",true,{"key":28,"text":29,"correct":22},"C","8℃",{"key":31,"text":32,"correct":22},"D","10℃","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},713761,"电力设备的额定电压高于实际使用工作电压时的试验电压,如采用额定电压较高的设备作为代用设备时,其试验电压应按照()来确定。",[38,40,42],{"key":20,"text":39,"correct":22},"可承受的最高试验电压",{"key":24,"text":41,"correct":22},"设备的额定电压的试验标准",{"key":28,"text":43,"correct":26},"实际使用的额定工作电压",{"id":45,"libraryId":5,"type":46,"typeLabel":47,"stem":48,"options":49,"answer":53,"analysis":33},713762,3,"判断题","接地体的对地电阻和接地线电阻的总和,称为接地装置的绝缘电阻。",[50,52],{"key":20,"text":51,"correct":22},"正确",{"key":24,"text":53,"correct":26},"错误",{"id":55,"libraryId":5,"type":46,"typeLabel":47,"stem":56,"options":57,"answer":51,"analysis":33},713763,"对油浸式变压器及电抗器的绝缘试验应在充满合格油,并静止一定时间,待气泡消除后进行,一般来说设备额定电压为500kV时,静止时间要求&gt;72h。",[58,59],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":61,"libraryId":5,"type":46,"typeLabel":47,"stem":62,"options":63,"answer":51,"analysis":33},713764,"根据冲击耐压试验的冲击波的不同波形,可分为雷电冲击波试验、操作冲击波试验、全波试验及截波试验。",[64,65],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":67,"libraryId":5,"type":46,"typeLabel":47,"stem":68,"options":69,"answer":53,"analysis":33},713765,"对均匀电场,气隙中各处电场强度按双曲线函数规律变化。",[70,71],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":26},{"id":73,"libraryId":5,"type":46,"typeLabel":47,"stem":74,"options":75,"answer":53,"analysis":33},713766,"对稍不均匀电场,空气间隙的平均击穿场强与均匀电场相比要高。",[76,77],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":26},{"id":79,"libraryId":5,"type":46,"typeLabel":47,"stem":80,"options":81,"answer":51,"analysis":33},713767,"工频耐压试验在试验时利用外部升压设备产生高压试验电压对被试设备进行耐压试验,因此也称作外施电压耐压试验。",[82,83],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":85,"libraryId":5,"type":46,"typeLabel":47,"stem":86,"options":87,"answer":51,"analysis":33},713768,"油间隙的冲击击穿电压与工频和直流的击穿电压相比要高很多。",[88,89],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":91,"libraryId":5,"type":46,"typeLabel":47,"stem":92,"options":93,"answer":51,"analysis":33},713769,"测量吸收比,应分别读取绝缘电阻表15s和60s时的绝缘电阻值。",[94,95],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":97,"libraryId":5,"type":46,"typeLabel":47,"stem":98,"options":99,"answer":53,"analysis":33},713770,"电气设备停电试验应完成保证安全的组织措施和技术措施,严格执行《电气设备预防性试验规程》的有关规定。",[100,101],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":26},{"id":103,"libraryId":5,"type":46,"typeLabel":47,"stem":104,"options":105,"answer":53,"analysis":33},713771,"如变压器油经过脱气处理,则其击穿电压与压力的关系为随压力增大而升高。",[106,107],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":26},{"id":109,"libraryId":5,"type":46,"typeLabel":47,"stem":110,"options":111,"answer":53,"analysis":33},713772,"绝缘介质在交流电压作用下,其中电阻性的电流的大小与被试品的电容量大小有关。",[112,113],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":26},{"id":115,"libraryId":5,"type":46,"typeLabel":47,"stem":116,"options":117,"answer":53,"analysis":33},713773,"对于同一电容C如接在不同频率的交流电路中时,频率越高则容抗越大。",[118,119],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":26},{"id":121,"libraryId":5,"type":46,"typeLabel":47,"stem":122,"options":123,"answer":53,"analysis":33},713774,"操作冲击击穿电压的波前时间T1大于临界波前时间时,当T1时间越长时,击穿电压越低。",[124,125],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":26},{"id":127,"libraryId":5,"type":46,"typeLabel":47,"stem":128,"options":129,"answer":51,"analysis":33},713775,"电气设备的预防性试验,就是要及时发现电气设备在运行中出现的各种潜伏性缺陷。",[130,131],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":133,"libraryId":5,"type":46,"typeLabel":47,"stem":134,"options":135,"answer":51,"analysis":33},713776,"在工程实际中,对不同的间隙长度S,对应的临界波前时间T0一般均在100~500μs之间。",[136,137],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":139,"libraryId":5,"type":46,"typeLabel":47,"stem":140,"options":141,"answer":53,"analysis":33},713777,"感应耐压试验所施加的试验电压是一个持续时间很短的冲击波。",[142,143],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":26},{"id":145,"libraryId":5,"type":46,"typeLabel":47,"stem":146,"options":147,"answer":53,"analysis":33},713778,"工频耐压试验时,产生容升现象的原因为试验时的电感性负载电流流经试验变压器一、二次绕组时在漏抗上的压降所致。",[148,149],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":26},{"id":151,"libraryId":5,"type":46,"typeLabel":47,"stem":152,"options":153,"answer":51,"analysis":33},713779,"检验电气设备绝缘状况的一个非常简单而又十分有效的方法是测量电气设备的绝缘电阻。",[154,155],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":157,"libraryId":5,"type":46,"typeLabel":47,"stem":158,"options":159,"answer":51,"analysis":33},713780,"工频耐压试验时,加至试验标准电压后的持续时间,凡无特殊说明均为1min。",[160,161],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":163,"libraryId":5,"type":46,"typeLabel":47,"stem":164,"options":165,"answer":51,"analysis":33},713781,"QS1电桥进行低压测量时,不需要升压试验变压器,也不需要高压标准电容器。",[166,167],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":169,"libraryId":5,"type":46,"typeLabel":47,"stem":170,"options":171,"answer":51,"analysis":33},713782,"电源的电动势是一个定值,与外电路的负载大小无关。",[172,173],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":175,"libraryId":5,"type":46,"typeLabel":47,"stem":176,"options":177,"answer":51,"analysis":33},713783,"直流电压绝缘试验中,负极性接线指负极加压,正极接地。",[178,179],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":181,"libraryId":5,"type":46,"typeLabel":47,"stem":182,"options":183,"answer":53,"analysis":33},713784,"工频耐压试验时,与保护间隙串接的保护电阻器,其阻值通常取0.1~0.5Ω\u002FV。",[184,185],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":26},{"id":187,"libraryId":5,"type":46,"typeLabel":47,"stem":188,"options":189,"answer":51,"analysis":33},713785,"直流电压作用下流过绝缘介质的电流,吸收电流是由于介质的偶极子在直流电压电场的作用下发生缓慢转动而引起的偶极子极化电流,以及由不同介质或介质的不均匀引起的夹层式极化电流。",[190,191],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":193,"libraryId":5,"type":46,"typeLabel":47,"stem":194,"options":195,"answer":51,"analysis":33},713786,"绝缘介质在交流电压作用下,其中电容性的电流的大小与被试品的电容量大小有关。",[196,197],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":199,"libraryId":5,"type":46,"typeLabel":47,"stem":200,"options":201,"answer":53,"analysis":33},713787,"工频耐压试验时,串接在试验变压器的高压输出端的保护电阻一般采用瓷介电阻或碳膜电阻。",[202,203],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":26},{"id":205,"libraryId":5,"type":46,"typeLabel":47,"stem":206,"options":207,"answer":51,"analysis":33},713788,"交流耐压试验包括工频耐压试验及感应耐压试验等。",[208,209],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":211,"libraryId":5,"type":46,"typeLabel":47,"stem":212,"options":213,"answer":51,"analysis":33},713789,"均匀电场气隙中一旦出现自持放电,间隙将立即击穿。",[214,215],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":217,"libraryId":5,"type":46,"typeLabel":47,"stem":218,"options":219,"answer":51,"analysis":33},713790,"智能型介质损耗测试仪采用反接法时,接线方式为从仪器上引出一根线,,接到被试品的一个高压接线端子,被试品的另一端接地。",[220,221],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":223,"libraryId":5,"type":46,"typeLabel":47,"stem":224,"options":225,"answer":51,"analysis":33},713791,"高压试验时既要注意试验人员的人身安全,也要注意非试验人员误碰试验电压出现人身触电。",[226,227],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":229,"libraryId":5,"type":46,"typeLabel":47,"stem":230,"options":231,"answer":51,"analysis":33},713792,"雷电冲击电压和操作冲击电压的波形持续时间较短,属于瞬态作用的电压。",[232,233],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":235,"libraryId":5,"type":46,"typeLabel":47,"stem":236,"options":237,"answer":51,"analysis":33},713793,"同一种固体绝缘材料在承受交流、直流或冲击电压等不同电压的作用时,其击穿电压常常不同。",[238,239],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":241,"libraryId":5,"type":46,"typeLabel":47,"stem":242,"options":243,"answer":51,"analysis":33},713794,"产生直流高压的半波整流电路中,高压整流硅堆的额定参数主要有额定反峰电压和额定整流电流。",[244,245],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":247,"libraryId":5,"type":46,"typeLabel":47,"stem":248,"options":249,"answer":51,"analysis":33},713795,"断电灭火紧急切断带电线路导线时,剪断的位置应选择在电源方向的支持物附近。()",[250,251],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":253,"libraryId":5,"type":46,"typeLabel":47,"stem":254,"options":255,"answer":51,"analysis":33},713796,"电火花、电弧的温度很高,不仅能引起可燃物燃烧,还能使金属熔化、飞溅,构成危险的火源。()",[256,257],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":259,"libraryId":5,"type":46,"typeLabel":47,"stem":260,"options":261,"answer":53,"analysis":33},713797,"电气设备预防性试验报告等资料应技术交流,作为日后电气设备安排大、小修计划时的参考依据。",[262,263],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":26},{"id":265,"libraryId":5,"type":46,"typeLabel":47,"stem":266,"options":267,"answer":51,"analysis":33},713798,"电阻分压式变比电桥测量变压比,测量中需调节可变电阻使检流计为零。",[268,269],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":271,"libraryId":5,"type":46,"typeLabel":47,"stem":272,"options":273,"answer":53,"analysis":33},713799,"规程规定,对于220kV及以上且容量为200MVA及以上的电力变压器均应测量极化指数。",[274,275],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":26},{"id":277,"libraryId":5,"type":46,"typeLabel":47,"stem":278,"options":279,"answer":51,"analysis":33},713800,"对稍不均匀电场或极不均匀电场的棒-棒间隙,其击穿电压与极性无关。",[280,281],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":283,"libraryId":5,"type":46,"typeLabel":47,"stem":284,"options":285,"answer":51,"analysis":33},713801,"测量电气设备介质损耗角正切值tanδ时,防止外界磁场干扰的主要措施是将测量仪器尽量远离干扰源。",[286,287],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":289,"libraryId":5,"type":46,"typeLabel":47,"stem":290,"options":291,"answer":53,"analysis":33},713802,"西林电桥正接线与反接线相比其抗干扰能力要弱。",[292,293],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":26},{"id":295,"libraryId":5,"type":46,"typeLabel":47,"stem":296,"options":297,"answer":53,"analysis":33},713803,"SF6气体具有优良的导电性能,故非常适用于高压断路器中。",[298,299],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":26},{"id":301,"libraryId":5,"type":46,"typeLabel":47,"stem":302,"options":303,"answer":51,"analysis":33},713804,"工频耐压试验中,作为耐压试验的调压设备,一般采用自耦调压器或移圈式调压器。",[304,305],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":307,"libraryId":5,"type":46,"typeLabel":47,"stem":308,"options":309,"answer":51,"analysis":33},713805,"在进行绝缘试验时,先进行非破坏性试验,最后进行破坏性试验。",[310,311],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":313,"libraryId":5,"type":46,"typeLabel":47,"stem":314,"options":315,"answer":53,"analysis":33},713806,"SF6气体具有优良的灭弧性能,其灭弧性能比空气强2.3~3倍。",[316,317],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":26},{"id":319,"libraryId":5,"type":46,"typeLabel":47,"stem":320,"options":321,"answer":51,"analysis":33},713807,"在极不均匀电场中,自持放电电压只是开始发生电晕的电压,称为电晕起始电压。",[322,323],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":325,"libraryId":5,"type":46,"typeLabel":47,"stem":326,"options":327,"answer":51,"analysis":33},713808,"测量试品的绝缘电阻时,一般应在空气相对湿度不高于80%的条件下进行。",[328,329],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},{"id":331,"libraryId":5,"type":46,"typeLabel":47,"stem":332,"options":333,"answer":51,"analysis":33},713809,"通过测量电阻性电流IR与电容性电流IC的比值可以判断绝缘介质在交流电压作用下的损耗情况,其比值称为介质损耗角正切值。",[334,335],{"key":20,"text":51,"correct":26},{"key":24,"text":53,"correct":22},[337,340,343,345,348,351],{"id":338,"name":339,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":341,"name":342,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":344,"name":342,"category":7,"favorite":8},336,{"id":346,"name":347,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":349,"name":350,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":352,"name":353,"category":7,"favorite":8},353,"(N1)叉车司机"]