[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-382-9":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":519},{"id":5,"name":6,"category":7,"favorite":8},382,"电力电缆","特种作业",0,9,50,1595,[13,31,41,51,61,71,81,91,101,111,121,131,141,151,161,171,181,191,201,211,221,231,241,251,261,271,281,291,301,311,321,331,341,351,361,371,381,391,399,409,419,429,439,449,459,469,479,489,499,509],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":30},712015,1,"单选题","组装式预制型电缆中间接头结构中采用()制成。",[19,23,27],{"key":20,"text":21,"correct":22},"A","多种不同材料",true,{"key":24,"text":25,"correct":26},"B","单一材料整体",false,{"key":28,"text":29,"correct":26},"C","单一材料分段组合","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":20,"analysis":30},712016,"必须保证电力电缆隧道在城市各种给水排水管网的()。",[35,37,39],{"key":20,"text":36,"correct":22},"上方",{"key":24,"text":38,"correct":26},"两侧",{"key":28,"text":40,"correct":26},"下方",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":20,"analysis":30},712017,"电缆的类别特征、绝缘类型、导体材料等在型号中用()表示。",[45,47,49],{"key":20,"text":46,"correct":22},"汉语拼音的第一个大写字母",{"key":24,"text":48,"correct":26},"汉语拼音的首字母的小写",{"key":28,"text":50,"correct":26},"数字",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":28,"analysis":30},712018,"当电力电缆路径与铁路交叉时,宜采用()交叉方式布置。",[55,57,59],{"key":20,"text":56,"correct":26},"斜穿",{"key":24,"text":58,"correct":26},"水平",{"key":28,"text":60,"correct":22},"垂直",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":24,"analysis":30},712019,"电缆群敷设在同一通道中,位于同侧的多层支架配置应()。",[65,67,69],{"key":20,"text":66,"correct":26},"电压从高到低、弱电到强电",{"key":24,"text":68,"correct":22},"电压从高到低、强电到弱电",{"key":28,"text":70,"correct":26},"电压从低到高、弱电到强电",{"id":72,"libraryId":5,"type":15,"typeLabel":16,"stem":73,"options":74,"answer":24,"analysis":30},712020,"油浸纸绝缘电缆,用带状绝缘缠绕应力锥,内绝缘以绝缘油为主绝缘,称为()。",[75,77,79],{"key":20,"text":76,"correct":26},"预制式终端",{"key":24,"text":78,"correct":22},"绕包式终端",{"key":28,"text":80,"correct":26},"热缩式终端",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":24,"analysis":30},712021,"更换不合格的护层保护器属于()检修。",[85,87,89],{"key":20,"text":86,"correct":26},"电缆本体",{"key":24,"text":88,"correct":22},"电缆附属设备",{"key":28,"text":90,"correct":26},"电缆终端和接头",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":24,"analysis":30},712022,"一般地,随着含水率增大,交联聚乙烯绝缘电缆的介质损耗角正切()。",[95,97,99],{"key":20,"text":96,"correct":26},"下降",{"key":24,"text":98,"correct":22},"上升",{"key":28,"text":100,"correct":26},"不变",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":20,"analysis":30},712023,"敷设在厂房内、隧道内和不填沙电缆沟内的电缆,应采用()。",[105,107,109],{"key":20,"text":106,"correct":22},"裸铠装",{"key":24,"text":108,"correct":26},"一般外护套",{"key":28,"text":110,"correct":26},"有塑料护套铠装",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":20,"analysis":30},712024,"110kV交联聚乙烯电缆外护套采用()材料。",[115,117,119],{"key":20,"text":116,"correct":22},"聚乙烯或聚氯乙烯",{"key":24,"text":118,"correct":26},"沥青或油漆",{"key":28,"text":120,"correct":26},"铅或铝",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":28,"analysis":30},712025,"电力电缆线路的外力破坏事故,在电缆线路事故中所占比例()。",[125,127,129],{"key":20,"text":126,"correct":26},"很小",{"key":24,"text":128,"correct":26},"中等",{"key":28,"text":130,"correct":22},"很大",{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":24,"analysis":30},712026,"油浸纸绝缘电缆浸渍剂的体积膨胀系数比铅或铝金属的()。",[135,137,139],{"key":20,"text":136,"correct":26},"小",{"key":24,"text":138,"correct":22},"大",{"key":28,"text":140,"correct":26},"相等",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":20,"analysis":30},712027,"高压和超高压充油电缆接头的铅封一般分()次进行。",[145,147,149],{"key":20,"text":146,"correct":22},"2",{"key":24,"text":148,"correct":26},"1",{"key":28,"text":150,"correct":26},"3",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":24,"analysis":30},712028,"电缆的闪络性故障很多出现于电缆()内。",[155,157,159],{"key":20,"text":156,"correct":26},"本体绝缘",{"key":24,"text":158,"correct":22},"中间接头或终端",{"key":28,"text":160,"correct":26},"本体屏蔽层",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":20,"analysis":30},712029,"当电缆间需要保持一定间隙时,需要在每隔()处固定。",[165,167,169],{"key":20,"text":166,"correct":22},"10m",{"key":24,"text":168,"correct":26},"50m",{"key":28,"text":170,"correct":26},"100m",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":24,"analysis":30},712030,"中间接头的部件中,对中长期接触油类具有良好耐受能力的管形收缩部件称为()。",[175,177,179],{"key":20,"text":176,"correct":26},"热收缩雨裙",{"key":24,"text":178,"correct":22},"热收缩耐油管",{"key":28,"text":180,"correct":26},"热收缩应力控制管",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":20,"analysis":30},712031,"对于6kV及以上电缆,导体屏蔽层的作用是使()有较好的接触。",[185,187,189],{"key":20,"text":186,"correct":22},"导体和绝缘层",{"key":24,"text":188,"correct":26},"绝缘层与金属护套",{"key":28,"text":190,"correct":26},"导体与屏蔽层",{"id":192,"libraryId":5,"type":15,"typeLabel":16,"stem":193,"options":194,"answer":24,"analysis":30},712032,"电缆线芯采用紧压形的目的是()。",[195,197,199],{"key":20,"text":196,"correct":26},"减小绝缘厚度",{"key":24,"text":198,"correct":22},"减小电缆线芯外径",{"key":28,"text":200,"correct":26},"绝缘内部电场分布均匀",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":24,"analysis":30},712033,"通常,传输功率越大,输送距离越远,则选择的电压等级()。",[205,207,209],{"key":20,"text":206,"correct":26},"越低",{"key":24,"text":208,"correct":22},"越高",{"key":28,"text":210,"correct":26},"不受影响",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":20,"analysis":30},712034,"电缆绝缘表面的半导电颗粒要去除和擦拭,但不能用()擦拭。",[215,217,219],{"key":20,"text":216,"correct":22},"擦过半导电层的清洁纸",{"key":24,"text":218,"correct":26},"擦过绝缘层的清洁纸",{"key":28,"text":220,"correct":26},"擦过绝缘层的清洁布",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":20,"analysis":30},712035,"中性点直接接地电力系统发生单相接地时,()。",[225,227,229],{"key":20,"text":226,"correct":22},"非故障相对地电压不变",{"key":24,"text":228,"correct":26},"用电设备能正常运行",{"key":28,"text":230,"correct":26},"接地相对地电压不变",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":24,"analysis":30},712036,"阻燃交联聚乙烯电缆在填充物、绕包层、内衬层及外护套等的原材料中加()。",[235,237,239],{"key":20,"text":236,"correct":26},"耐火层",{"key":24,"text":238,"correct":22},"阻燃剂",{"key":28,"text":240,"correct":26},"低卤的聚氯乙烯",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":24,"analysis":30},712037,"对于XLPE绝缘电缆,具有抑制树枝生长和热屏障作用的是()。",[245,247,249],{"key":20,"text":246,"correct":26},"绝缘屏蔽层",{"key":24,"text":248,"correct":22},"半导电屏蔽层",{"key":28,"text":250,"correct":26},"导体屏蔽层",{"id":252,"libraryId":5,"type":15,"typeLabel":16,"stem":253,"options":254,"answer":24,"analysis":30},712038,"电缆工井、排管、电缆沟及其支架应()巡查一次。",[255,257,259],{"key":20,"text":256,"correct":26},"每1年",{"key":24,"text":258,"correct":22},"每2年",{"key":28,"text":260,"correct":26},"每3年",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":20,"analysis":30},712039,"电力电缆的电应力控制指的是对()的控制。",[265,267,269],{"key":20,"text":266,"correct":22},"电场分布和电场强度",{"key":24,"text":268,"correct":26},"电场强度和机械应力",{"key":28,"text":270,"correct":26},"电场分布和机械应力",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":24,"analysis":30},712040,"对高压电缆外屏蔽的要求之一是:能有效地提高瓷套管外绝缘的()。",[275,277,279],{"key":20,"text":276,"correct":26},"机械强度",{"key":24,"text":278,"correct":22},"闪络强度",{"key":28,"text":280,"correct":26},"耐热强度",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":28,"analysis":30},712041,"固定灭火装置包括()。",[285,287,289],{"key":20,"text":286,"correct":26},"1211灭火器",{"key":24,"text":288,"correct":26},"干粉灭火器",{"key":28,"text":290,"correct":22},"水喷雾灭火系统",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":20,"analysis":30},712042,"在极不均匀电场中,最大场强与平均场强相差很大,在外加电压及其平均场强()时,在电极曲率半径较小处附近产生局部的游离放电,这就是电晕。",[295,297,299],{"key":20,"text":296,"correct":22},"较低",{"key":24,"text":298,"correct":26},"居中",{"key":28,"text":300,"correct":26},"较大",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":24,"analysis":30},712043,"在吊装作业时,若没有规定的吊点,应使吊点与重心铅垂线的交点在()。",[305,307,309],{"key":20,"text":306,"correct":26},"几何中心",{"key":24,"text":308,"correct":22},"重心",{"key":28,"text":310,"correct":26},"低面中心",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":20,"analysis":30},712044,"低压电缆盘多为()结构。",[315,317,319],{"key":20,"text":316,"correct":22},"木质",{"key":24,"text":318,"correct":26},"橡胶",{"key":28,"text":320,"correct":26},"钢",{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":28,"analysis":30},712045,"当绝缘性能逐渐降低达到允许范围之下时,绝缘不能继续承受正常运行电压,这一过程所需的时间,称为()。",[325,327,329],{"key":20,"text":326,"correct":26},"电缆的短时允许工作时间",{"key":24,"text":328,"correct":26},"电缆的长时允许工作时间",{"key":28,"text":330,"correct":22},"电缆绝缘的寿命",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":28,"analysis":30},712046,"电力电缆沟道敷设时,最下层至沟底或地面间的规定距离为()。",[335,337,339],{"key":20,"text":336,"correct":26},"100-150mm",{"key":24,"text":338,"correct":26},"100-120mm",{"key":28,"text":340,"correct":22},"50-100mm",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":28,"analysis":30},712047,"在低温下施工时,电缆一旦变脆很易损坏以致无法安装,所以要求电缆()。",[345,347,349],{"key":20,"text":346,"correct":26},"耐热性能好",{"key":24,"text":348,"correct":26},"化学性能稳定",{"key":28,"text":350,"correct":22},"具有耐低温性能",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":20,"analysis":30},712048,"在检修变压器,要装设接地线时,应()。",[355,357,359],{"key":20,"text":356,"correct":22},"先装接地端,再装导线端",{"key":24,"text":358,"correct":26},"先装中相",{"key":28,"text":360,"correct":26},"先装导线端,再装接地端",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":28,"analysis":30},712049,"电缆路径在道路下面的规划位置,不应布置在()下面。",[365,367,369],{"key":20,"text":366,"correct":26},"绿化带",{"key":24,"text":368,"correct":26},"人行道",{"key":28,"text":370,"correct":22},"机动车道",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":24,"analysis":30},712050,"电缆水分在线监测系统是在电缆结构中内置一个分布式的水传感器,通过测量其()来判断水分的侵入情况。",[375,377,379],{"key":20,"text":376,"correct":26},"含水量",{"key":24,"text":378,"correct":22},"直流电阻",{"key":28,"text":380,"correct":26},"交流阻抗",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":28,"analysis":30},712051,"对敷设于空气中的电力电缆,选择截面时,规定的标准敷设温度为()。",[385,387,389],{"key":20,"text":386,"correct":26},"25℃",{"key":24,"text":388,"correct":26},"30℃",{"key":28,"text":390,"correct":22},"40℃",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":20,"analysis":30},712052,"10kV及以下电压等级油浸纸绝缘电缆线芯采用扇形,是因为这有利于()。",[395,397,398],{"key":20,"text":396,"correct":22},"减小电缆外径",{"key":24,"text":196,"correct":26},{"key":28,"text":200,"correct":26},{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":24,"analysis":30},712053,"电缆终端处的电场分布不均匀,油浸纸绝缘电缆轴向电场是径向电场的()。",[403,405,407],{"key":20,"text":404,"correct":26},"1\u002F2",{"key":24,"text":406,"correct":22},"1\u002F100",{"key":28,"text":408,"correct":26},"1\u002F10",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":20,"analysis":30},712054,"塑料电缆绝缘外无防水金属护套时,常采用()材料进行附件密封。",[413,415,417],{"key":20,"text":414,"correct":22},"防水带及防水密封胶",{"key":24,"text":416,"correct":26},"金属密封",{"key":28,"text":418,"correct":26},"普通塑料",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":20,"analysis":30},712055,"分部工程“电缆终端”中包含分项工程()。",[423,425,427],{"key":20,"text":424,"correct":22},"户外终端",{"key":24,"text":426,"correct":26},"接地线",{"key":28,"text":428,"correct":26},"沟槽开挖",{"id":430,"libraryId":5,"type":15,"typeLabel":16,"stem":431,"options":432,"answer":28,"analysis":30},712056,"电力电缆隧道一般为()结构。",[433,435,437],{"key":20,"text":434,"correct":26},"木头",{"key":24,"text":436,"correct":26},"砖砌",{"key":28,"text":438,"correct":22},"钢筋混凝土",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":28,"analysis":30},712057,"自容式充油电力电缆按金属护套和加强层不同,其允许最高稳态油压分别为()。",[443,445,447],{"key":20,"text":444,"correct":26},"0.1MPa和0.2MPa",{"key":24,"text":446,"correct":26},"0.2MPa和0.42MPa",{"key":28,"text":448,"correct":22},"0.4MPa和0.8MPa",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":28,"analysis":30},712058,"电气设备检修时,工作票的有效期限以()为限。",[453,455,457],{"key":20,"text":454,"correct":26},"当天",{"key":24,"text":456,"correct":26},"一般不超过两天",{"key":28,"text":458,"correct":22},"批准的检修期限",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":20,"analysis":30},712059,"中低压大截面的电力电缆和超高压电缆一般为()。",[463,465,467],{"key":20,"text":464,"correct":22},"单芯电缆",{"key":24,"text":466,"correct":26},"三芯电缆",{"key":28,"text":468,"correct":26},"五芯电缆",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":28,"analysis":30},712060,"直埋电缆时,电缆上面应有()厚的土层。",[473,475,477],{"key":20,"text":474,"correct":26},"35cm",{"key":24,"text":476,"correct":26},"25cm",{"key":28,"text":478,"correct":22},"15cm",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":20,"analysis":30},712061,"导体中流过交流电流时,越接近表面电流密度越大的现象称为()。",[483,485,487],{"key":20,"text":484,"correct":22},"集肤效应",{"key":24,"text":486,"correct":26},"边缘效应",{"key":28,"text":488,"correct":26},"邻近效应",{"id":490,"libraryId":5,"type":15,"typeLabel":16,"stem":491,"options":492,"answer":24,"analysis":30},712062,"110kV交联聚乙烯电缆的任意点绝缘厚度不得小于标称厚度的()。",[493,495,497],{"key":20,"text":494,"correct":26},"80%",{"key":24,"text":496,"correct":22},"90%",{"key":28,"text":498,"correct":26},"85%",{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":20,"analysis":30},712063,"高压及超高压电缆在安装附件前,一定要充分地(,)防止以后的绝缘回缩。",[503,505,507],{"key":20,"text":504,"correct":22},"加热调直",{"key":24,"text":506,"correct":26},"冷却调直",{"key":28,"text":508,"correct":26},"常温调直",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":20,"analysis":30},712064,"根据对触电事故发生统计分析,触电事故随季节有明显的变化,每年()季较为易发、集中。",[513,515,517],{"key":20,"text":514,"correct":22},"二;三",{"key":24,"text":516,"correct":26},"一;二",{"key":28,"text":518,"correct":26},"三;四",[520,523,526,528,531,534],{"id":521,"name":522,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":524,"name":525,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":527,"name":525,"category":7,"favorite":8},336,{"id":529,"name":530,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":532,"name":533,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":535,"name":536,"category":7,"favorite":8},353,"(N1)叉车司机"]