[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-382-7":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":514},{"id":5,"name":6,"category":7,"favorite":8},382,"电力电缆","特种作业",0,7,50,1595,[13,31,41,51,61,71,81,91,101,111,121,131,141,151,161,171,181,191,201,211,221,230,240,250,260,270,280,290,300,310,320,330,340,350,360,370,380,390,400,410,420,430,440,450,460,467,474,484,494,504],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":30},711915,1,"单选题","交流单相电力电缆的刚性固定,宜采用()等不构成磁性闭合回路的夹具。",[19,23,27],{"key":20,"text":21,"correct":22},"A","铝合金",true,{"key":24,"text":25,"correct":26},"B","钢",false,{"key":28,"text":29,"correct":26},"C","铁","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":24,"analysis":30},711916,"电力电缆隧道敷设时,最下层至沟底或地面间的规定距离为()。",[35,37,39],{"key":20,"text":36,"correct":26},"50-80mm",{"key":24,"text":38,"correct":22},"100-150mm",{"key":28,"text":40,"correct":26},"80-90mm",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":20,"analysis":30},711917,"当单芯电缆中()时,就会在电缆金属护套中产生感应电压。",[45,47,49],{"key":20,"text":46,"correct":22},"流过工频交流",{"key":24,"text":48,"correct":26},"流过直流电流",{"key":28,"text":50,"correct":26},"施加电压",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":20,"analysis":30},711918,"CYZQ102型电敷设时要求垂直落差不大于()。",[55,57,59],{"key":20,"text":56,"correct":22},"30m",{"key":24,"text":58,"correct":26},"20m",{"key":28,"text":60,"correct":26},"40m",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":28,"analysis":30},711919,"河底敷设的电缆应选择在()。",[65,67,69],{"key":20,"text":66,"correct":26},"湍急河段",{"key":24,"text":68,"correct":26},"落差大河段",{"key":28,"text":70,"correct":22},"稳定河段",{"id":72,"libraryId":5,"type":15,"typeLabel":16,"stem":73,"options":74,"answer":28,"analysis":30},711920,"模塑式终端一般用于35kV及以下()。",[75,77,79],{"key":20,"text":76,"correct":26},"油浸纸绝缘电缆",{"key":24,"text":78,"correct":26},"塑料绝缘电缆",{"key":28,"text":80,"correct":22},"交联聚乙烯绝缘电缆",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":28,"analysis":30},711921,"对无机械通风的一般性厂房内电力电缆,选择截面时,环境温度应确定为()。",[85,87,89],{"key":20,"text":86,"correct":26},"最热月的日最高气温平均值+5",{"key":24,"text":88,"correct":26},"通风设计温度",{"key":28,"text":90,"correct":22},"最热月的日最高气温平均值",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":28,"analysis":30},711922,"电缆隧道内温度过高,属于电缆()。",[95,97,99],{"key":20,"text":96,"correct":26},"接头和终端缺陷",{"key":24,"text":98,"correct":26},"线路附属设备缺陷",{"key":28,"text":100,"correct":22},"敷设路径上的缺陷",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":24,"analysis":30},711923,"与组装式相比,整体式预制型电缆中间接头现场安装时间()。",[105,107,109],{"key":20,"text":106,"correct":26},"基本相同",{"key":24,"text":108,"correct":22},"减小",{"key":28,"text":110,"correct":26},"增大",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":20,"analysis":30},711924,"在导体截面相同的情况下,交联聚乙烯电缆载流量()。",[115,117,119],{"key":20,"text":116,"correct":22},"大于充油电缆",{"key":24,"text":118,"correct":26},"与充油电缆相等",{"key":28,"text":120,"correct":26},"小于充油电缆",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":20,"analysis":30},711925,"当单芯电缆线芯外径与绝缘层外径之比为()时,导体表面最大电场强度最小。",[125,127,129],{"key":20,"text":126,"correct":22},"0.37",{"key":24,"text":128,"correct":26},"0.25",{"key":28,"text":130,"correct":26},"0.46",{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":28,"analysis":30},711926,"电缆施工完成后应将越过的孔洞进行封堵,其目的是()等。",[135,137,139],{"key":20,"text":136,"correct":26},"防晒、防水、防火",{"key":24,"text":138,"correct":26},"防晒、防火、防小动物",{"key":28,"text":140,"correct":22},"防水、防火、防小动物",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":28,"analysis":30},711927,"除交流系统用单芯电力电缆外,电力电缆相互间应有()空隙。",[145,147,149],{"key":20,"text":146,"correct":26},"20mm",{"key":24,"text":148,"correct":26},"50mm",{"key":28,"text":150,"correct":22},"35mm",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":24,"analysis":30},711928,"电缆绝缘老化的原因不包括()。",[155,157,159],{"key":20,"text":156,"correct":26},"化学老化",{"key":24,"text":158,"correct":22},"热老化",{"key":28,"text":160,"correct":26},"电老化",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":28,"analysis":30},711929,"我国规定的交流安全电压为()。",[165,167,169],{"key":20,"text":166,"correct":26},"、220V、42V、36V、12V",{"key":24,"text":168,"correct":26},"、380V、42V、36V、12V",{"key":28,"text":170,"correct":22},"、42V、36V、12V、6V",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":28,"analysis":30},711930,"在运行中,()和电火花或电弧等都是电气火灾的直接原因。",[175,177,179],{"key":20,"text":176,"correct":26},"、环境温度",{"key":24,"text":178,"correct":26},"、电压高低",{"key":28,"text":180,"correct":22},"、电流的热量",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":28,"analysis":30},711931,"敷设于电缆沟的电缆,其故障查找和修复时间也较长,主要原因是()。",[185,187,189],{"key":20,"text":186,"correct":26},"需要挖出电缆",{"key":24,"text":188,"correct":26},"查找故障点困难",{"key":28,"text":190,"correct":22},"需要重新敷设、做接头和试验",{"id":192,"libraryId":5,"type":15,"typeLabel":16,"stem":193,"options":194,"answer":28,"analysis":30},711932,"分部工程“电缆敷设”中包含的分项工程()。",[195,197,199],{"key":20,"text":196,"correct":26},"户外终端",{"key":24,"text":198,"correct":26},"接地线",{"key":28,"text":200,"correct":22},"沟槽开挖",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":20,"analysis":30},711933,"直埋电缆下面和上面均应铺厚度为()的软土或沙层。",[205,207,209],{"key":20,"text":206,"correct":22},"100mm",{"key":24,"text":208,"correct":26},"80mm",{"key":28,"text":210,"correct":26},"120mm",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":28,"analysis":30},711934,"状态检修的优点之一是()。",[215,217,219],{"key":20,"text":216,"correct":26},"没有针对性",{"key":24,"text":218,"correct":26},"定期拆装检修设备",{"key":28,"text":220,"correct":22},"提高设备利用率",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":24,"analysis":30},711935,"对敷设于水中的电力电缆,选择截面时,环境温度应确定为()。",[225,227,229],{"key":20,"text":226,"correct":26},"埋深处的最热月平均地温",{"key":24,"text":228,"correct":22},"最热月的日最高水温平均值",{"key":28,"text":88,"correct":26},{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":20,"analysis":30},711936,"对110kV及以上重要电缆线路的户外引出线连接点,在检修时应检查()表面情况。",[234,236,238],{"key":20,"text":235,"correct":22},"各接触面",{"key":24,"text":237,"correct":26},"导体表面",{"key":28,"text":239,"correct":26},"螺钉",{"id":241,"libraryId":5,"type":15,"typeLabel":16,"stem":242,"options":243,"answer":24,"analysis":30},711937,"低压脉冲法能很方便地测出电缆()故障点距离。",[244,246,248],{"key":20,"text":245,"correct":26},"中阻接地",{"key":24,"text":247,"correct":22},"低阻接地",{"key":28,"text":249,"correct":26},"高阻接地",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":24,"analysis":30},711938,"直埋电缆一般应选用()。",[254,256,258],{"key":20,"text":255,"correct":26},"橡胶电缆",{"key":24,"text":257,"correct":22},"铠装电缆",{"key":28,"text":259,"correct":26},"全塑电缆",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":20,"analysis":30},711939,"电力电缆沟道敷设时,电缆()。",[264,266,268],{"key":20,"text":265,"correct":22},"可直接放于沟底或电缆支架上",{"key":24,"text":267,"correct":26},"可直埋于沟底",{"key":28,"text":269,"correct":26},"不能放于电缆支架上",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":28,"analysis":30},711940,"为了保证电缆有较大的载流量,要求其()。",[274,276,278],{"key":20,"text":275,"correct":26},"耐低温性能好",{"key":24,"text":277,"correct":26},"耐压性能好",{"key":28,"text":279,"correct":22},"耐热性能好",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":28,"analysis":30},711941,"当没有必要将故障点电阻降到100Ω以下时,一般不采用()。",[284,286,288],{"key":20,"text":285,"correct":26},"冲击烧穿法",{"key":24,"text":287,"correct":26},"直流烧穿法",{"key":28,"text":289,"correct":22},"交流烧穿法",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":20,"analysis":30},711942,"吊装作业时不许()。",[294,296,298],{"key":20,"text":295,"correct":22},"拖拉和斜吊",{"key":24,"text":297,"correct":26},"竖直吊起",{"key":28,"text":299,"correct":26},"在室内吊装",{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":28,"analysis":30},711943,"终端用大型瓷套等易碎绝缘部件,应放于(),用泡沫塑料、草袋等围遮包牢。",[304,306,308],{"key":20,"text":305,"correct":26},"专门的木架上",{"key":24,"text":307,"correct":26},"平放于干燥地面",{"key":28,"text":309,"correct":22},"原包装箱内",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":24,"analysis":30},711944,"XHF型电缆不具有()能力。",[314,316,318],{"key":20,"text":315,"correct":26},"防燃",{"key":24,"text":317,"correct":22},"承受机械外力",{"key":28,"text":319,"correct":26},"防腐蚀",{"id":321,"libraryId":5,"type":15,"typeLabel":16,"stem":322,"options":323,"answer":28,"analysis":30},711945,"绞合线芯电缆的线芯采用分裂导体结构时,各分裂单元呈()形状。",[324,326,328],{"key":20,"text":325,"correct":26},"圆形",{"key":24,"text":327,"correct":26},"椭圆形",{"key":28,"text":329,"correct":22},"扇形",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":28,"analysis":30},711946,"中性点不接地电力系统发生单相接地时,()。",[334,336,338],{"key":20,"text":335,"correct":26},"中性点对地电压不变",{"key":24,"text":337,"correct":26},"健全相对地电压不变",{"key":28,"text":339,"correct":22},"线电压不变",{"id":341,"libraryId":5,"type":15,"typeLabel":16,"stem":342,"options":343,"answer":20,"analysis":30},711947,"重新包绕老化的失色相色带属于()检修。",[344,346,348],{"key":20,"text":345,"correct":22},"电缆终端和接头",{"key":24,"text":347,"correct":26},"电缆本体",{"key":28,"text":349,"correct":26},"电缆附属设备",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":20,"analysis":30},711948,"不允许带电移动()电缆。",[354,356,358],{"key":20,"text":355,"correct":22},"35kV及以上",{"key":24,"text":357,"correct":26},"10kV",{"key":28,"text":359,"correct":26},"1kV",{"id":361,"libraryId":5,"type":15,"typeLabel":16,"stem":362,"options":363,"answer":28,"analysis":30},711949,"电力电缆隧道敷设时,隧道内一般每隔()左右设一个积水坑。",[364,366,368],{"key":20,"text":365,"correct":26},"200m",{"key":24,"text":367,"correct":26},"100m",{"key":28,"text":369,"correct":22},"50m",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":20,"analysis":30},711950,"热收缩部件收缩前与在非限制条件下收缩后径向收缩率应不大于()。",[374,376,378],{"key":20,"text":375,"correct":22},"50%",{"key":24,"text":377,"correct":26},"5%",{"key":28,"text":379,"correct":26},"1%",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":20,"analysis":30},711951,"电缆终端接头和中间接头应()存放。",[384,386,388],{"key":20,"text":385,"correct":22},"分类",{"key":24,"text":387,"correct":26},"混合",{"key":28,"text":389,"correct":26},"密封",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":24,"analysis":30},711952,"为使单芯电缆导体表面最大电场强度变化范围较小,要求线芯外径与绝缘层外径之比在()之间。",[394,396,398],{"key":20,"text":395,"correct":26},"0.15-0.25",{"key":24,"text":397,"correct":22},"0.25-0.50",{"key":28,"text":399,"correct":26},"0.20-0.40",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":20,"analysis":30},711953,"绝缘中气隙的击穿场强比绝缘的击穿场强()。",[404,406,408],{"key":20,"text":405,"correct":22},"小很多",{"key":24,"text":407,"correct":26},"相等",{"key":28,"text":409,"correct":26},"大很多",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":28,"analysis":30},711954,"组装式预制型电缆中间接头内()。",[414,416,418],{"key":20,"text":415,"correct":26},"需要填充绝缘剂",{"key":24,"text":417,"correct":26},"需要充气",{"key":28,"text":419,"correct":22},"不需要填充绝缘剂或充气",{"id":421,"libraryId":5,"type":15,"typeLabel":16,"stem":422,"options":423,"answer":20,"analysis":30},711955,"电力电缆的绝缘材料性能发生随时间不可逆下降的现象时,称为()。",[424,426,428],{"key":20,"text":425,"correct":22},"绝缘老化",{"key":24,"text":427,"correct":26},"绝缘正常",{"key":28,"text":429,"correct":26},"绝缘击穿",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":20,"analysis":30},711956,"电缆有绝缘层和保护层,所以()。",[434,436,438],{"key":20,"text":435,"correct":22},"供电安全可靠",{"key":24,"text":437,"correct":26},"结构简单",{"key":28,"text":439,"correct":26},"维护工作简单",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":28,"analysis":30},711957,"电力电缆线路的运行维护的反外力工作应严格电缆线路()的定期巡视和特巡制度。",[444,446,448],{"key":20,"text":445,"correct":26},"监督人员",{"key":24,"text":447,"correct":26},"运行人员",{"key":28,"text":449,"correct":22},"专责人",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":20,"analysis":30},711958,"110kV交联聚乙烯电缆为防止铝护套氧化和腐蚀,在其表面涂敷()。",[454,456,458],{"key":20,"text":455,"correct":22},"沥青",{"key":24,"text":457,"correct":26},"涂料",{"key":28,"text":459,"correct":26},"油漆",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":28,"analysis":30},711959,"110kV电缆的导体一般紧压成()。",[464,465,466],{"key":20,"text":329,"correct":26},{"key":24,"text":327,"correct":26},{"key":28,"text":325,"correct":22},{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":24,"analysis":30},711960,"充沙电缆沟内电缆平行敷设沟中时,电缆间净距应不小于()。",[471,472,473],{"key":20,"text":146,"correct":26},{"key":24,"text":150,"correct":22},{"key":28,"text":206,"correct":26},{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":28,"analysis":30},711961,"10kV及以上电压等级电缆线芯截面一般采用圆形,是因为这有利于()。",[478,480,482],{"key":20,"text":479,"correct":26},"散热",{"key":24,"text":481,"correct":26},"减小集肤效应",{"key":28,"text":483,"correct":22},"绝缘内部电场分布均匀",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":28,"analysis":30},711962,"在矿井、化工及炼油厂敷设的电缆,其终端接头应采用()。",[488,490,492],{"key":20,"text":489,"correct":26},"模塑式",{"key":24,"text":491,"correct":26},"浇注式",{"key":28,"text":493,"correct":22},"冷缩式",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":28,"analysis":30},711963,"110kV及以上XLPE电缆护套破损造成多点接地时,则其接地线电流能达到()。",[498,500,502],{"key":20,"text":499,"correct":26},"线芯电流的30%-45%",{"key":24,"text":501,"correct":26},"线芯电流的95%-100%",{"key":28,"text":503,"correct":22},"线芯电流的50%-95%",{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":24,"analysis":30},711964,"在交流电压下,绝缘层电压分配与温度()。",[508,510,512],{"key":20,"text":509,"correct":26},"成正比",{"key":24,"text":511,"correct":22},"无关",{"key":28,"text":513,"correct":26},"成反比",[515,518,521,523,526,529],{"id":516,"name":517,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":519,"name":520,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":522,"name":520,"category":7,"favorite":8},336,{"id":524,"name":525,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":527,"name":528,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":530,"name":531,"category":7,"favorite":8},353,"(N1)叉车司机"]