[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-382-6":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":518},{"id":5,"name":6,"category":7,"favorite":8},382,"电力电缆","特种作业",0,6,50,1595,[13,31,41,50,60,70,80,90,100,110,120,130,140,150,160,170,180,190,200,210,220,230,240,250,260,270,280,290,300,310,320,330,340,350,360,370,380,390,400,410,420,430,440,450,460,470,480,490,498,508],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":30},711865,1,"单选题","电气设备发生接地故障,人沿着接地电流的散流方向行走时双脚之间的电位差称为()。",[19,23,27],{"key":20,"text":21,"correct":22},"A","接触电压",false,{"key":24,"text":25,"correct":26},"B","跨步电压",true,{"key":28,"text":29,"correct":22},"C","双脚电压","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":24,"analysis":30},711866,"发现触电伤员呼吸、心跳停止时,应立即在现场用()就地抢救,以支持呼吸和循环。",[35,37,39],{"key":20,"text":36,"correct":22},"紧急救护法",{"key":24,"text":38,"correct":26},"心肺复苏法",{"key":28,"text":40,"correct":22},"人工呼吸法",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":24,"analysis":30},711867,"对于变电站内的电缆线路通道上的路面,一般应()至少进行一次巡视。",[45,47,49],{"key":20,"text":46,"correct":22},"一个月",{"key":24,"text":48,"correct":26},"三个月",{"key":28,"text":46,"correct":22},{"id":51,"libraryId":5,"type":15,"typeLabel":16,"stem":52,"options":53,"answer":24,"analysis":30},711868,"|XLPE电缆采用单端接地方式时,接地线电流为()。",[54,56,58],{"key":20,"text":55,"correct":22},"阻性电流",{"key":24,"text":57,"correct":26},"容性电流",{"key":28,"text":59,"correct":22},"感性电流",{"id":61,"libraryId":5,"type":15,"typeLabel":16,"stem":62,"options":63,"answer":24,"analysis":30},711869,"一般地,电缆的故障大部分发生在()上。",[64,66,68],{"key":20,"text":65,"correct":22},"导体",{"key":24,"text":67,"correct":26},"附件",{"key":28,"text":69,"correct":22},"绝缘",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":30},711870,"接地线应连接于()的接地体上。",[74,76,78],{"key":20,"text":75,"correct":22},"可拆卸且接地电阻足够小",{"key":24,"text":77,"correct":26},"不可拆卸且接地电阻符合要求",{"key":28,"text":79,"correct":22},"可拆卸且接地电阻足够大",{"id":81,"libraryId":5,"type":15,"typeLabel":16,"stem":82,"options":83,"answer":28,"analysis":30},711871,"中低压热缩或冷缩电缆终端表面有闪络痕迹时,其原因主要有()。",[84,86,88],{"key":20,"text":85,"correct":22},"规格选用不当",{"key":24,"text":87,"correct":22},"材料不良",{"key":28,"text":89,"correct":26},"地区污秽程度严重",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":24,"analysis":30},711872,"单芯电缆绝缘层中最大电场强度位于()上。",[94,96,98],{"key":20,"text":95,"correct":22},"线芯中心",{"key":24,"text":97,"correct":26},"线芯表面",{"key":28,"text":99,"correct":22},"绝缘层外表面",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":28,"analysis":30},711873,"配电网是指电力系统中直接与()相连的网络。",[104,106,108],{"key":20,"text":105,"correct":22},"电源点",{"key":24,"text":107,"correct":22},"供电点",{"key":28,"text":109,"correct":26},"用户",{"id":111,"libraryId":5,"type":15,"typeLabel":16,"stem":112,"options":113,"answer":24,"analysis":30},711874,"在交流电压下,对油浸纸绝缘,电场分布不合理,气隙承受场强()。",[114,116,118],{"key":20,"text":115,"correct":22},"极小",{"key":24,"text":117,"correct":26},"大",{"key":28,"text":119,"correct":22},"小",{"id":121,"libraryId":5,"type":15,"typeLabel":16,"stem":122,"options":123,"answer":20,"analysis":30},711875,"110kV交联聚乙烯电缆铝或铅护套任意点的厚度不小于其标称厚度的()。",[124,126,128],{"key":20,"text":125,"correct":26},"85%",{"key":24,"text":127,"correct":22},"80%",{"key":28,"text":129,"correct":22},"90%",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":30},711876,"110kV交联聚乙烯电缆的外电极的作用是()。",[134,136,138],{"key":20,"text":135,"correct":22},"作为电缆接地保护",{"key":24,"text":137,"correct":26},"作为外护套耐压试验的电极",{"key":28,"text":139,"correct":22},"实现电磁屏蔽",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":24,"analysis":30},711877,"热缩电缆终端以()为基本材料。",[144,146,148],{"key":20,"text":145,"correct":22},"绝缘纸",{"key":24,"text":147,"correct":26},"聚合物",{"key":28,"text":149,"correct":22},"橡胶",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":28,"analysis":30},711878,"用于连接两根电缆形成连续电路的中间接头称为()。",[154,156,158],{"key":20,"text":155,"correct":22},"转换接头",{"key":24,"text":157,"correct":22},"绝缘接头",{"key":28,"text":159,"correct":26},"直通接头",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":24,"analysis":30},711879,"直埋10kV电缆相互交叉时的最小净距为()。",[164,166,168],{"key":20,"text":165,"correct":22},"0.1m",{"key":24,"text":167,"correct":26},"0.5m",{"key":28,"text":169,"correct":22},"0.2m",{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":20,"analysis":30},711880,"中性点经电阻接地方式适用于()电力系统。",[174,176,178],{"key":20,"text":175,"correct":26},"10kV及以下",{"key":24,"text":177,"correct":22},"110kV",{"key":28,"text":179,"correct":22},"220kV",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":24,"analysis":30},711881,"通过测量单芯电缆(),判断电缆护套绝缘是否损伤、电缆接地系统连接是否正确。",[184,186,188],{"key":20,"text":185,"correct":22},"导体的空载电流",{"key":24,"text":187,"correct":26},"金属护套接地电流",{"key":28,"text":189,"correct":22},"绝缘的泄漏电流",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":20,"analysis":30},711882,"电缆外护套的材料通常是()。",[194,196,198],{"key":20,"text":195,"correct":26},"聚氯乙烯或聚乙烯",{"key":24,"text":197,"correct":22},"钢带或钢丝",{"key":28,"text":199,"correct":22},"铝带或铝丝",{"id":201,"libraryId":5,"type":15,"typeLabel":16,"stem":202,"options":203,"answer":20,"analysis":30},711883,"我国1kV以上三相交流系统中包含()电压等级的额定电压。",[204,206,208],{"key":20,"text":205,"correct":26},"10kV",{"key":24,"text":207,"correct":22},"400kV",{"key":28,"text":209,"correct":22},"600kV",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":20,"analysis":30},711884,"在剥去一段铅套的电缆线芯上加一逐渐上升的电压时,所产生的电晕放电的现象为()。",[214,216,218],{"key":20,"text":215,"correct":26},"紫色光环及丝丝声",{"key":24,"text":217,"correct":22},"平行的红色刷形",{"key":28,"text":219,"correct":22},"白色树枝状滑动光线",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":20,"analysis":30},711885,"电缆电压等级的表示由两个数值构成并以斜杠分开,斜杠前面数值是()。",[224,226,228],{"key":20,"text":225,"correct":26},"相电压",{"key":24,"text":227,"correct":22},"线电压",{"key":28,"text":229,"correct":22},"绝缘水平",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":24,"analysis":30},711886,"为有利于及时消缺升级,35kV及以上电缆线路每()进行一次设备等级划分。",[234,236,238],{"key":20,"text":235,"correct":22},"3个月",{"key":24,"text":237,"correct":26},"1年",{"key":28,"text":239,"correct":22},"6个月",{"id":241,"libraryId":5,"type":15,"typeLabel":16,"stem":242,"options":243,"answer":24,"analysis":30},711887,"对于10kV电缆,传输功率应小于5000kW,传输距离应小于()km。",[244,246,248],{"key":20,"text":245,"correct":22},"5",{"key":24,"text":247,"correct":26},"10",{"key":28,"text":249,"correct":22},"8",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":28,"analysis":30},711888,"对于10kV直埋电缆,自地面到电缆上面外皮的距离为()。",[254,256,258],{"key":20,"text":255,"correct":22},"1.2m",{"key":24,"text":257,"correct":22},"1.0m",{"key":28,"text":259,"correct":26},"0.7m",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":24,"analysis":30},711889,"电力电缆在运输车上不允许()。",[264,266,268],{"key":20,"text":265,"correct":22},"竖放",{"key":24,"text":267,"correct":26},"平放",{"key":28,"text":269,"correct":22},"斜放",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":24,"analysis":30},711890,"在直流电压下,电缆绝缘层的绝缘电阻随温度上升()关系变化。",[274,276,278],{"key":20,"text":275,"correct":22},"呈线性",{"key":24,"text":277,"correct":26},"呈指数",{"key":28,"text":279,"correct":22},"呈正弦",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":28,"analysis":30},711891,"6~35kV橡胶绝缘电力电缆为多芯绞合时,采用具有防腐性能的()填料。",[284,286,288],{"key":20,"text":285,"correct":22},"麻",{"key":24,"text":287,"correct":22},"纸",{"key":28,"text":289,"correct":26},"纤维",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":20,"analysis":30},711892,"单芯电力电缆排管敷设时,不能采用()等磁性材料的管子。",[294,296,298],{"key":20,"text":295,"correct":26},"钢管",{"key":24,"text":297,"correct":22},"铝管",{"key":28,"text":299,"correct":22},"塑料管",{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":20,"analysis":30},711893,"6~35kV交联聚乙烯电缆有()结构。",[304,306,308],{"key":20,"text":305,"correct":26},"单芯和三芯",{"key":24,"text":307,"correct":22},"多芯",{"key":28,"text":309,"correct":22},"单芯",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":20,"analysis":30},711894,"电力电缆水底敷设时,若从供电端到受电端不是整根,可采用()连接。",[314,316,318],{"key":20,"text":315,"correct":26},"软接头",{"key":24,"text":317,"correct":22},"硬接头",{"key":28,"text":319,"correct":22},"任意接头",{"id":321,"libraryId":5,"type":15,"typeLabel":16,"stem":322,"options":323,"answer":24,"analysis":30},711895,"GIS终端与()在结构上是基本相同的。",[324,326,328],{"key":20,"text":325,"correct":22},"空气终端",{"key":24,"text":327,"correct":26},"变压器终端",{"key":28,"text":329,"correct":22},"预制式终端",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":28,"analysis":30},711896,"6~10kV油浸纸绝缘电缆敷设最大允许位差应不超过()。",[334,336,338],{"key":20,"text":335,"correct":22},"25m",{"key":24,"text":337,"correct":22},"20m",{"key":28,"text":339,"correct":26},"15m",{"id":341,"libraryId":5,"type":15,"typeLabel":16,"stem":342,"options":343,"answer":24,"analysis":30},711897,"一般用电设备包括()。",[344,346,348],{"key":20,"text":345,"correct":22},"轧钢设备",{"key":24,"text":347,"correct":26},"小型电动机",{"key":28,"text":349,"correct":22},"电气化铁道",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":20,"analysis":30},711898,"如果XLPE电缆采用单端接地方式,可采用()监测电缆主绝缘状态。",[354,356,358],{"key":20,"text":355,"correct":26},"接地线电流法",{"key":24,"text":357,"correct":22},"线芯电流法",{"key":28,"text":359,"correct":22},"短路电流法",{"id":361,"libraryId":5,"type":15,"typeLabel":16,"stem":362,"options":363,"answer":24,"analysis":30},711899,"电缆特别适合用于()的地区。",[364,366,368],{"key":20,"text":365,"correct":22},"无污染",{"key":24,"text":367,"correct":26},"严重污染",{"key":28,"text":369,"correct":22},"中度污染",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":24,"analysis":30},711900,"电缆护层的作用是()。",[374,376,378],{"key":20,"text":375,"correct":22},"使线芯与大地绝缘",{"key":24,"text":377,"correct":26},"防潮防腐防机械损伤",{"key":28,"text":379,"correct":22},"使导体与绝缘层良好接触",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":20,"analysis":30},711901,"聚氯乙烯绝缘电缆的优点是()。",[384,386,388],{"key":20,"text":385,"correct":26},"不延燃",{"key":24,"text":387,"correct":22},"介质损耗角正切值小",{"key":28,"text":389,"correct":22},"耐热性好",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":20,"analysis":30},711902,"10kV及以上电压等级电缆线芯截面一般采用()。",[394,396,398],{"key":20,"text":395,"correct":26},"圆形",{"key":24,"text":397,"correct":22},"椭圆形铝",{"key":28,"text":399,"correct":22},"扇形",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":28,"analysis":30},711903,"在交流电压下,绝缘层电场分布与负载变化()。",[404,406,408],{"key":20,"text":405,"correct":22},"成正比",{"key":24,"text":407,"correct":22},"成反比",{"key":28,"text":409,"correct":26},"无关",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":24,"analysis":30},711904,"既能承受一般机械外力又能承受相当拉力的电缆是()。",[414,416,418],{"key":20,"text":415,"correct":22},"ZQD",{"key":24,"text":417,"correct":26},"ZQD30",{"key":28,"text":419,"correct":22},"ZLQD20",{"id":421,"libraryId":5,"type":15,"typeLabel":16,"stem":422,"options":423,"answer":28,"analysis":30},711905,"电力电缆路径走向切忌()。",[424,426,428],{"key":20,"text":425,"correct":22},"平行道路中心线",{"key":24,"text":427,"correct":22},"从道路一侧直走",{"key":28,"text":429,"correct":26},"多次从道路一侧转到另一侧",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":28,"analysis":30},711906,"电缆接头局部过热,属于电缆()。",[434,436,438],{"key":20,"text":435,"correct":22},"本体缺陷",{"key":24,"text":437,"correct":22},"线路附属设备缺陷",{"key":28,"text":439,"correct":26},"接头和终端缺陷",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":20,"analysis":30},711907,"进入SF6电气设备室或与其相连的电缆夹层、沟道,应先检测()含量是否合格。",[444,446,448],{"key":20,"text":445,"correct":26},"氧气和SF6气体",{"key":24,"text":447,"correct":22},"二氧化碳",{"key":28,"text":449,"correct":22},"氮气",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":20,"analysis":30},711908,"铝包电缆的位差可以比铅包电缆的位差大()。",[454,456,458],{"key":20,"text":455,"correct":26},"3-5m",{"key":24,"text":457,"correct":22},"2-3m",{"key":28,"text":459,"correct":22},"5-8m",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":28,"analysis":30},711909,"一般地,随着温度升高,交联聚乙烯绝缘电缆的绝缘材料的绝缘电阻()。",[464,466,468],{"key":20,"text":465,"correct":22},"上升",{"key":24,"text":467,"correct":22},"不变",{"key":28,"text":469,"correct":26},"下降",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":20,"analysis":30},711910,"作为电气工作者,员工必须熟知本工种的()和施工现场的安全生产制度,不违章作业。",[474,476,478],{"key":20,"text":475,"correct":26},"安全操作规程",{"key":24,"text":477,"correct":22},"生产安排",{"key":28,"text":479,"correct":22},"工作时间",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":24,"analysis":30},711911,"能敷设于水底环境的电缆是()。",[484,486,488],{"key":20,"text":485,"correct":22},"ZQ03",{"key":24,"text":487,"correct":26},"ZQ41",{"key":28,"text":489,"correct":22},"ZQ23",{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":20,"analysis":30},711912,"用于连接两个不同类型绝缘材料或不同导体截面电缆的中间接头是()。",[494,496,497],{"key":20,"text":495,"correct":26},"过渡接头",{"key":24,"text":157,"correct":22},{"key":28,"text":155,"correct":22},{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":20,"analysis":30},711913,"对高压电缆外屏蔽的要求之一是:在()电压下不能出现电晕。",[502,504,506],{"key":20,"text":503,"correct":26},"工作",{"key":24,"text":505,"correct":22},"型式试验",{"key":28,"text":507,"correct":22},"过电压",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":28,"analysis":30},711914,"为检修10kV电力电缆户外终端头,需要拉开断路器两侧隔离开关,下列操作中错误的是()。",[512,514,516],{"key":20,"text":513,"correct":22},"检查断路器确在开位",{"key":24,"text":515,"correct":22},"首先核对线路名称",{"key":28,"text":517,"correct":26},"直接拉开隔离开关",[519,522,525,527,530,533],{"id":520,"name":521,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":523,"name":524,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":526,"name":524,"category":7,"favorite":8},336,{"id":528,"name":529,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":531,"name":532,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":534,"name":535,"category":7,"favorite":8},353,"(N1)叉车司机"]