[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-382-2":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":515},{"id":5,"name":6,"category":7,"favorite":8},382,"电力电缆","特种作业",0,2,50,1595,[13,31,41,51,61,70,80,90,100,110,120,130,140,150,160,170,179,189,199,209,219,229,239,249,259,269,279,289,299,308,318,328,338,347,357,365,375,385,395,405,415,425,435,445,455,465,475,485,495,505],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":30},711664,1,"单选题","中性点不接地电力系统的优点是()。",[19,23,27],{"key":20,"text":21,"correct":22},"A","供电可靠性高",true,{"key":24,"text":25,"correct":26},"B","绝缘要求低",false,{"key":28,"text":29,"correct":26},"C","需要切除接地设备","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":28,"analysis":30},711665,"在电缆型号中,表示交联聚乙烯绝缘的字母是()。",[35,37,39],{"key":20,"text":36,"correct":26},"J",{"key":24,"text":38,"correct":26},"Y",{"key":28,"text":40,"correct":22},"YJ",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":20,"analysis":30},711666,"橡胶电力电缆适合经常移动的电气设备,因为()。",[45,47,49],{"key":20,"text":46,"correct":22},"柔性好",{"key":24,"text":48,"correct":26},"耐化学腐蚀",{"key":28,"text":50,"correct":26},"抗老化",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":20,"analysis":30},711667,"|XLPE电缆采用单端接地方式时,若电缆绝缘恶化,接地线的容性电流()。",[55,57,59],{"key":20,"text":56,"correct":22},"增大",{"key":24,"text":58,"correct":26},"减小",{"key":28,"text":60,"correct":26},"不变",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":28,"analysis":30},711668,"一般地,随着温度升高,交联聚乙烯绝缘电缆的绝缘材料的击穿场强()。",[65,67,68],{"key":20,"text":66,"correct":26},"上升",{"key":24,"text":60,"correct":26},{"key":28,"text":69,"correct":22},"下降",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":30},711669,"电缆线芯对地或线芯之间绝缘电阻低于(),属于低阻接地或短路故障。",[74,76,78],{"key":20,"text":75,"correct":22},"数千欧姆",{"key":24,"text":77,"correct":26},"数百欧姆",{"key":28,"text":79,"correct":26},"数兆欧姆",{"id":81,"libraryId":5,"type":15,"typeLabel":16,"stem":82,"options":83,"answer":24,"analysis":30},711670,"吊装作业时与10kV带电物体的距离不小于()。",[84,86,88],{"key":20,"text":85,"correct":26},"1.2m",{"key":24,"text":87,"correct":22},"2.0m",{"key":28,"text":89,"correct":26},"1.5m",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":28,"analysis":30},711671,"电力系统的谐波源包括()。",[94,96,98],{"key":20,"text":95,"correct":26},"断路器",{"key":24,"text":97,"correct":26},"变压器",{"key":28,"text":99,"correct":22},"电阻器",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":20,"analysis":30},711672,"交联聚乙烯绝缘电缆的优点是()。",[104,106,108],{"key":20,"text":105,"correct":22},"具有高弹性",{"key":24,"text":107,"correct":26},"价格低",{"key":28,"text":109,"correct":26},"耐热性好",{"id":111,"libraryId":5,"type":15,"typeLabel":16,"stem":112,"options":113,"answer":24,"analysis":30},711673,"热缩式终端一般用于()塑料绝缘电缆。",[114,116,118],{"key":20,"text":115,"correct":26},"110kV及以下",{"key":24,"text":117,"correct":22},"35kV及以下",{"key":28,"text":119,"correct":26},"110kV及以上",{"id":121,"libraryId":5,"type":15,"typeLabel":16,"stem":122,"options":123,"answer":20,"analysis":30},711674,"电缆线路试运行阶段内发现由施工质量引发的问题,由()负责处理。",[124,126,128],{"key":20,"text":125,"correct":22},"施工单位",{"key":24,"text":127,"correct":26},"运行单位",{"key":28,"text":129,"correct":26},"其他有资质的维修单位",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":20,"analysis":30},711675,"组装式预制型电缆中间接头绝缘由()段组成。",[134,136,138],{"key":20,"text":135,"correct":22},"3",{"key":24,"text":137,"correct":26},"2",{"key":28,"text":139,"correct":26},"1",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":28,"analysis":30},711676,"在实际应用中,实现XLPE电缆线路的局部放电在线监测()。",[144,146,148],{"key":20,"text":145,"correct":26},"很容易",{"key":24,"text":147,"correct":26},"有一些难度",{"key":28,"text":149,"correct":22},"难度很大",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":28,"analysis":30},711677,"整体式预制型电缆中间接头现场安装时,()。",[154,156,158],{"key":20,"text":155,"correct":26},"需要进行制造和组装",{"key":24,"text":157,"correct":26},"需要进行复杂的组装",{"key":28,"text":159,"correct":22},"将整体预制件直接套在电缆绝缘上",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":24,"analysis":30},711678,"低压配电电缆线路中主要采用()。",[164,166,168],{"key":20,"text":165,"correct":26},"单芯电缆",{"key":24,"text":167,"correct":22},"四芯和五芯电缆",{"key":28,"text":169,"correct":26},"三芯电缆",{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":24,"analysis":30},711679,"电缆线路运行时不仅受环境和散热条件影响,而且在故障前期局部温度会()。",[174,176,178],{"key":20,"text":175,"correct":26},"降低",{"key":24,"text":177,"correct":22},"升高",{"key":28,"text":60,"correct":26},{"id":180,"libraryId":5,"type":15,"typeLabel":16,"stem":181,"options":182,"answer":28,"analysis":30},711680,"电力电缆排管敷设时,为便于检查和敷设应设置电缆人井,其间距不宜大于()。",[183,185,187],{"key":20,"text":184,"correct":26},"70m",{"key":24,"text":186,"correct":26},"60m",{"key":28,"text":188,"correct":22},"50m",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":28,"analysis":30},711681,"挤包绝缘电力电缆的终端头制作()。",[193,195,197],{"key":20,"text":194,"correct":26},"困难",{"key":24,"text":196,"correct":26},"类似油浸纸绝缘电缆",{"key":28,"text":198,"correct":22},"方便",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":24,"analysis":30},711682,"直流输电一般不采用()。",[203,205,207],{"key":20,"text":204,"correct":26},"充油电缆",{"key":24,"text":206,"correct":22},"橡皮绝缘电缆",{"key":28,"text":208,"correct":26},"油浸纸绝缘电缆",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":24,"analysis":30},711683,"电力电缆水底敷设时,从供电端到受电端尽量是()。",[213,215,217],{"key":20,"text":214,"correct":26},"2根连接",{"key":24,"text":216,"correct":22},"1个整根",{"key":28,"text":218,"correct":26},"多根连接",{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":221,"options":222,"answer":20,"analysis":30},711684,"电力电缆沟道敷设时,最上层至沟顶或楼板间的规定距离为()。",[223,225,227],{"key":20,"text":224,"correct":22},"150-200mm",{"key":24,"text":226,"correct":26},"300-350mm",{"key":28,"text":228,"correct":26},"350-450mm",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":28,"analysis":30},711685,"危急缺陷应于()组织检修处理。",[233,235,237],{"key":20,"text":234,"correct":26},"三个月内",{"key":24,"text":236,"correct":26},"一个月内尽快",{"key":28,"text":238,"correct":22},"当日及时",{"id":240,"libraryId":5,"type":15,"typeLabel":16,"stem":241,"options":242,"answer":20,"analysis":30},711686,"根据电缆线路综合运行情况实行“到期必修,修必修好”的原则,对电缆或附件进行的定期检查、实验及维修,称为()。",[243,245,247],{"key":20,"text":244,"correct":22},"预防性检修",{"key":24,"text":246,"correct":26},"矫正性检修",{"key":28,"text":248,"correct":26},"状态检修",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":28,"analysis":30},711687,"温度变化时,油浸纸绝缘电缆浸渍剂绝缘层中产生的气隙一般分布在()。",[253,255,257],{"key":20,"text":254,"correct":26},"绝缘层外层",{"key":24,"text":256,"correct":26},"绝缘层中层",{"key":28,"text":258,"correct":22},"绝缘层内层",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":28,"analysis":30},711688,"选择电缆导体截面时,在可能的情况下尽量采用()。",[263,265,267],{"key":20,"text":264,"correct":26},"2根以上小截面电缆",{"key":24,"text":266,"correct":26},"2个小截面电缆",{"key":28,"text":268,"correct":22},"1根大截面电缆",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":24,"analysis":30},711689,"对20kV及以上电缆的中间接头,电应力控制的传统办法是()。",[273,275,277],{"key":20,"text":274,"correct":26},"应力锥",{"key":24,"text":276,"correct":22},"切削反应力锥",{"key":28,"text":278,"correct":26},"铅胀",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":28,"analysis":30},711690,"当电气装置或设备发生火灾或引燃附近可燃物时,首先要()。",[283,285,287],{"key":20,"text":284,"correct":26},"、迅速灭火",{"key":24,"text":286,"correct":26},"、拉开开关",{"key":28,"text":288,"correct":22},"、切断电源",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":28,"analysis":30},711691,"对无机械通风的有热源设备的厂房内的电力电缆,选择截面时,环境温度应确定为()。",[293,295,297],{"key":20,"text":294,"correct":26},"通风设计温度",{"key":24,"text":296,"correct":26},"最热月的日最高气温平均值",{"key":28,"text":298,"correct":22},"最热月的日最高气温平均值+5",{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":24,"analysis":30},711692,"对于35kV直埋电缆穿过农田时,自地面到电缆上面外皮的距离为()。",[303,305,306],{"key":20,"text":304,"correct":26},"0.7m",{"key":24,"text":85,"correct":22},{"key":28,"text":307,"correct":26},"1.0m",{"id":309,"libraryId":5,"type":15,"typeLabel":16,"stem":310,"options":311,"answer":20,"analysis":30},711693,"状态检修的基础和根据是()。",[312,314,316],{"key":20,"text":313,"correct":22},"在线监测",{"key":24,"text":315,"correct":26},"正常维护",{"key":28,"text":317,"correct":26},"定期维护",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":28,"analysis":30},711694,"铜芯、交联聚乙烯绝缘、波纹铝护套、聚氯乙烯外护套阻燃电力电缆型号为()。",[322,324,326],{"key":20,"text":323,"correct":26},"YJV02",{"key":24,"text":325,"correct":26},"YJLW02",{"key":28,"text":327,"correct":22},"ZR-YJLW02",{"id":329,"libraryId":5,"type":15,"typeLabel":16,"stem":330,"options":331,"answer":28,"analysis":30},711695,"装卸电缆时应()吊装。",[332,334,336],{"key":20,"text":333,"correct":26},"多盘同时",{"key":24,"text":335,"correct":26},"三盘同时",{"key":28,"text":337,"correct":22},"一盘一盘",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":20,"analysis":30},711696,"油浸纸绝缘统包型电力电缆适合用于()电压等级。",[342,344,346],{"key":20,"text":343,"correct":22},"10kV及以下",{"key":24,"text":345,"correct":26},"20-35kV",{"key":28,"text":119,"correct":26},{"id":348,"libraryId":5,"type":15,"typeLabel":16,"stem":349,"options":350,"answer":20,"analysis":30},711697,"分部工程“接地系统”中包含分项工程()。",[351,353,355],{"key":20,"text":352,"correct":22},"接地极",{"key":24,"text":354,"correct":26},"接地电阻测试",{"key":28,"text":356,"correct":26},"户外终端",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":24,"analysis":30},711698,"直埋电缆表面距地面应不小于()。",[361,363,364],{"key":20,"text":362,"correct":26},"0.5m",{"key":24,"text":304,"correct":22},{"key":28,"text":307,"correct":26},{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":20,"analysis":30},711699,"参与自验收的单位是()。",[369,371,373],{"key":20,"text":370,"correct":22},"施工单位和监理单位",{"key":24,"text":372,"correct":26},"施工单位和运行单位",{"key":28,"text":374,"correct":26},"施工单位和设计单位",{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":20,"analysis":30},711700,"油浸纸绝缘统包型电力电缆的金属护套为()。",[379,381,383],{"key":20,"text":380,"correct":22},"多芯共用",{"key":24,"text":382,"correct":26},"单芯独立使用",{"key":28,"text":384,"correct":26},"两芯共用",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":28,"analysis":30},711701,"扑灭火灾时,灭火人员应站在()进行灭火。",[389,391,393],{"key":20,"text":390,"correct":26},"、侧面",{"key":24,"text":392,"correct":26},"、下风侧",{"key":28,"text":394,"correct":22},"、上风侧",{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":397,"options":398,"answer":20,"analysis":30},711702,"低于规定温度敷设电缆时应采取加热措施,塑料绝缘电缆的规定敷设温度是()。",[399,401,403],{"key":20,"text":400,"correct":22},"0℃",{"key":24,"text":402,"correct":26},"—10℃",{"key":28,"text":404,"correct":26},"5℃",{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":28,"analysis":30},711703,"XLPE绝缘电缆能抑制树枝生长,因为半导电屏蔽层中加入()。",[409,411,413],{"key":20,"text":410,"correct":26},"阻燃物质",{"key":24,"text":412,"correct":26},"抗腐蚀物质",{"key":28,"text":414,"correct":22},"捕捉水分物质",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":24,"analysis":30},711704,"在电路中,电缆线路本身呈()。",[419,421,423],{"key":20,"text":420,"correct":26},"阻性",{"key":24,"text":422,"correct":22},"容性",{"key":28,"text":424,"correct":26},"感性",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":28,"analysis":30},711705,"对于380V电缆,传输功率应小于175kW,传输距离应小于()km。",[429,431,433],{"key":20,"text":430,"correct":26},"0.45",{"key":24,"text":432,"correct":26},"0.40",{"key":28,"text":434,"correct":22},"0.35",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":24,"analysis":30},711706,"绝缘测试试验项目齐全、结果合格,运行中未发现任何缺陷的电缆设备为()。",[439,441,443],{"key":20,"text":440,"correct":26},"二级设备",{"key":24,"text":442,"correct":22},"一级设备",{"key":28,"text":444,"correct":26},"三级设备",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":24,"analysis":30},711707,"在发生的电缆故障中,()占大多数。",[449,451,453],{"key":20,"text":450,"correct":26},"低阻",{"key":24,"text":452,"correct":22},"高阻",{"key":28,"text":454,"correct":26},"中阻",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":20,"analysis":30},711708,"对于油浸纸绝缘套管电缆终端,正常巡视应检查()。",[459,461,463],{"key":20,"text":460,"correct":22},"有无渗漏油",{"key":24,"text":462,"correct":26},"是否有膨胀",{"key":28,"text":464,"correct":26},"是否有电晕现象",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":28,"analysis":30},711709,"为了减小电缆发热、减缓绝缘老化速度,要求绝缘材料的介质损耗角正切值()。",[469,471,473],{"key":20,"text":470,"correct":26},"高",{"key":24,"text":472,"correct":26},"适中",{"key":28,"text":474,"correct":22},"低",{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":20,"analysis":30},711710,"当导体截面较大、相距很近、频率很高时,则必须考虑()效应。",[479,481,483],{"key":20,"text":480,"correct":22},"邻近",{"key":24,"text":482,"correct":26},"集肤",{"key":28,"text":484,"correct":26},"热",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":28,"analysis":30},711711,"电缆线芯对地或线芯之间绝缘电阻(),属于高阻接地或短路故障。",[489,491,493],{"key":20,"text":490,"correct":26},"高于正常值很多",{"key":24,"text":492,"correct":26},"高于数兆欧姆",{"key":28,"text":494,"correct":22},"低于正常值很多但高于数千欧姆",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":24,"analysis":30},711712,"直埋地下的电缆线路故障点的粗测方法是()。",[499,501,503],{"key":20,"text":500,"correct":26},"直接观察",{"key":24,"text":502,"correct":22},"专用仪器检测",{"key":28,"text":504,"correct":26},"理论计算",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":20,"analysis":30},711713,"电力系统运行的首要任务是()。",[509,511,513],{"key":20,"text":510,"correct":22},"满足用户对供电可靠性的要求",{"key":24,"text":512,"correct":26},"保证功率因数不变",{"key":28,"text":514,"correct":26},"提高运行经济性",[516,519,522,524,527,530],{"id":517,"name":518,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":520,"name":521,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":523,"name":521,"category":7,"favorite":8},336,{"id":525,"name":526,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":528,"name":529,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":531,"name":532,"category":7,"favorite":8},353,"(N1)叉车司机"]