[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-382-17":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":368},{"id":5,"name":6,"category":7,"favorite":8},382,"电力电缆","特种作业",0,17,50,1595,[13,31,41,51,61,71,81,94,104,114,124,134,140,146,152,158,164,170,176,182,188,194,200,206,212,218,224,230,236,242,248,254,260,266,272,278,284,290,296,302,308,314,320,326,332,338,344,350,356,362],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":30},712415,1,"单选题","ZQF20和ZLQF20型电缆适合敷设于()。",[19,23,27],{"key":20,"text":21,"correct":22},"A","室内",true,{"key":24,"text":25,"correct":26},"B","水下",false,{"key":28,"text":29,"correct":26},"C","竖井","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":20,"analysis":30},712416,"大截面导体采用分裂导体结构,是为了减小集肤效应,提高()。",[35,37,39],{"key":20,"text":36,"correct":22},"传输容量",{"key":24,"text":38,"correct":26},"绝缘水平",{"key":28,"text":40,"correct":26},"耐压强度",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":28,"analysis":30},712417,"中性点直接接地方式适用于()电力系统。",[45,47,49],{"key":20,"text":46,"correct":26},"3kV",{"key":24,"text":48,"correct":26},"10kV",{"key":28,"text":50,"correct":22},"220kV及以上",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":20,"analysis":30},712418,"提高电力系统运行经济性的措施之一是()。",[55,57,59],{"key":20,"text":56,"correct":22},"降低电网损耗",{"key":24,"text":58,"correct":26},"保证电能质量",{"key":28,"text":60,"correct":26},"加快电网建设",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":24,"analysis":30},712419,"交流单相电力电缆金属护层的接地必须保证其任一点感应电压在采取安全措施的情况下不得大于()。",[65,67,69],{"key":20,"text":66,"correct":26},"50V",{"key":24,"text":68,"correct":22},"100V",{"key":28,"text":70,"correct":26},"72V",{"id":72,"libraryId":5,"type":15,"typeLabel":16,"stem":73,"options":74,"answer":20,"analysis":30},712420,"中间接头按照用途不同分()类。",[75,77,79],{"key":20,"text":76,"correct":22},"7",{"key":24,"text":78,"correct":26},"4",{"key":28,"text":80,"correct":26},"10",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":92,"analysis":30},712421,"某地区10kV电缆今年10月发生故障5次,当月修复5次,及时修复4次,则其故障修复率为()。",[85,87,89,91],{"key":20,"text":86,"correct":26},"40%",{"key":24,"text":88,"correct":26},"50%",{"key":28,"text":90,"correct":26},"80%",{"key":92,"text":93,"correct":22},"D","100%",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":28,"analysis":30},712422,"不滴流油电力电缆适合用于()。",[98,100,102],{"key":20,"text":99,"correct":26},"寒冷地区",{"key":24,"text":101,"correct":26},"亚热带地区",{"key":28,"text":103,"correct":22},"热带地区",{"id":105,"libraryId":5,"type":15,"typeLabel":16,"stem":106,"options":107,"answer":24,"analysis":30},712423,"电缆采用聚氯乙烯护套的优点是()。",[108,110,112],{"key":20,"text":109,"correct":26},"耐热性好",{"key":24,"text":111,"correct":22},"阻燃性好",{"key":28,"text":113,"correct":26},"耐寒性好",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":20,"analysis":30},712424,"电缆及附件发生故障或严重缺陷不能正常工作时,必须进行的检修称为()。",[118,120,122],{"key":20,"text":119,"correct":22},"矫正性检修",{"key":24,"text":121,"correct":26},"定期检修",{"key":28,"text":123,"correct":26},"状态检修",{"id":125,"libraryId":5,"type":126,"typeLabel":127,"stem":128,"options":129,"answer":131,"analysis":30},712425,3,"判断题","6~10kV油浸纸绝缘电缆敷设最大允许位差应不超过15m。()",[130,132],{"key":20,"text":131,"correct":22},"正确",{"key":24,"text":133,"correct":26},"错误",{"id":135,"libraryId":5,"type":126,"typeLabel":127,"stem":136,"options":137,"answer":133,"analysis":30},712426,"一般地,近似认为单芯电缆的电场的电力线分布是沿轴向。()",[138,139],{"key":20,"text":131,"correct":26},{"key":24,"text":133,"correct":22},{"id":141,"libraryId":5,"type":126,"typeLabel":127,"stem":142,"options":143,"answer":131,"analysis":30},712427,"制作电缆终端接头,需要切断绝缘层、内护套。()",[144,145],{"key":20,"text":131,"correct":22},{"key":24,"text":133,"correct":26},{"id":147,"libraryId":5,"type":126,"typeLabel":127,"stem":148,"options":149,"answer":131,"analysis":30},712428,"为保证电缆敷设过程的安全,电源箱要采用TN-S保护系统。()",[150,151],{"key":20,"text":131,"correct":22},{"key":24,"text":133,"correct":26},{"id":153,"libraryId":5,"type":126,"typeLabel":127,"stem":154,"options":155,"answer":133,"analysis":30},712429,"电缆线路交叉互联和接地箱本体及其进线孔不得选用绝缘材料。()",[156,157],{"key":20,"text":131,"correct":26},{"key":24,"text":133,"correct":22},{"id":159,"libraryId":5,"type":126,"typeLabel":127,"stem":160,"options":161,"answer":133,"analysis":30},712430,"吊装作业时允许与220kV带电物体的距离小于6m。()",[162,163],{"key":20,"text":131,"correct":26},{"key":24,"text":133,"correct":22},{"id":165,"libraryId":5,"type":126,"typeLabel":127,"stem":166,"options":167,"answer":133,"analysis":30},712431,"绞合线芯电缆的线芯采用分裂导体结构时,分裂单元数目为6形状时最稳定。()",[168,169],{"key":20,"text":131,"correct":26},{"key":24,"text":133,"correct":22},{"id":171,"libraryId":5,"type":126,"typeLabel":127,"stem":172,"options":173,"answer":131,"analysis":30},712432,"冷缩电缆终端的特点之一是抗电晕、抗腐蚀性能强。()",[174,175],{"key":20,"text":131,"correct":22},{"key":24,"text":133,"correct":26},{"id":177,"libraryId":5,"type":126,"typeLabel":127,"stem":178,"options":179,"answer":133,"analysis":30},712433,"当电力电缆路径与铁路交叉时,宜采用斜穿交叉方式布置。()",[180,181],{"key":20,"text":131,"correct":26},{"key":24,"text":133,"correct":22},{"id":183,"libraryId":5,"type":126,"typeLabel":127,"stem":184,"options":185,"answer":133,"analysis":30},712434,"电力电缆隧道一般为砖砌结构。()",[186,187],{"key":20,"text":131,"correct":26},{"key":24,"text":133,"correct":22},{"id":189,"libraryId":5,"type":126,"typeLabel":127,"stem":190,"options":191,"answer":133,"analysis":30},712435,"充油电缆油压系统报警,属于电缆本体缺陷。()",[192,193],{"key":20,"text":131,"correct":26},{"key":24,"text":133,"correct":22},{"id":195,"libraryId":5,"type":126,"typeLabel":127,"stem":196,"options":197,"answer":133,"analysis":30},712436,"当单芯电缆中流过直流电流时,就会在电缆金属护套中产生感应电压。()",[198,199],{"key":20,"text":131,"correct":26},{"key":24,"text":133,"correct":22},{"id":201,"libraryId":5,"type":126,"typeLabel":127,"stem":202,"options":203,"answer":131,"analysis":30},712437,"在抢救触电者脱离电源时,未采取任何绝缘措施,救护人员不得直接触及触电者的皮肤或潮湿衣服。",[204,205],{"key":20,"text":131,"correct":22},{"key":24,"text":133,"correct":26},{"id":207,"libraryId":5,"type":126,"typeLabel":127,"stem":208,"options":209,"answer":133,"analysis":30},712438,"1kV四芯(3+1)聚氯乙烯绝缘电力电缆的导体中三相导体呈圆形。()",[210,211],{"key":20,"text":131,"correct":26},{"key":24,"text":133,"correct":22},{"id":213,"libraryId":5,"type":126,"typeLabel":127,"stem":214,"options":215,"answer":133,"analysis":30},712439,"延长电缆末端裸露的绝缘长度可以解决电缆外屏蔽切断处的电场集中问题。()",[216,217],{"key":20,"text":131,"correct":26},{"key":24,"text":133,"correct":22},{"id":219,"libraryId":5,"type":126,"typeLabel":127,"stem":220,"options":221,"answer":131,"analysis":30},712440,"|电缆路径在道路下面的规划位置,不应布置在机动车道下面。()",[222,223],{"key":20,"text":131,"correct":22},{"key":24,"text":133,"correct":26},{"id":225,"libraryId":5,"type":126,"typeLabel":127,"stem":226,"options":227,"answer":133,"analysis":30},712441,"电力电缆沟道敷设时,电力电缆与控制电缆应安装在沟道同侧的支架上。()",[228,229],{"key":20,"text":131,"correct":26},{"key":24,"text":133,"correct":22},{"id":231,"libraryId":5,"type":126,"typeLabel":127,"stem":232,"options":233,"answer":133,"analysis":30},712442,"对于35kV直埋电缆穿过农田时,自地面到电缆上面外皮的距离为1.0m。()",[234,235],{"key":20,"text":131,"correct":26},{"key":24,"text":133,"correct":22},{"id":237,"libraryId":5,"type":126,"typeLabel":127,"stem":238,"options":239,"answer":131,"analysis":30},712443,"电能以电磁波形式传播,传播速度是光速。()",[240,241],{"key":20,"text":131,"correct":22},{"key":24,"text":133,"correct":26},{"id":243,"libraryId":5,"type":126,"typeLabel":127,"stem":244,"options":245,"answer":131,"analysis":30},712444,"对运行中可能产生电火花、电弧和高温危险的电气设备和装置,不应放置在易燃的危险场所。()",[246,247],{"key":20,"text":131,"correct":22},{"key":24,"text":133,"correct":26},{"id":249,"libraryId":5,"type":126,"typeLabel":127,"stem":250,"options":251,"answer":133,"analysis":30},712445,"红外热像仪测温能随时给出测量信号。()",[252,253],{"key":20,"text":131,"correct":26},{"key":24,"text":133,"correct":22},{"id":255,"libraryId":5,"type":126,"typeLabel":127,"stem":256,"options":257,"answer":133,"analysis":30},712446,"油浸纸绝缘电缆封铅过程中,若温度过高、时间过长会使连接处机械强度低。()",[258,259],{"key":20,"text":131,"correct":26},{"key":24,"text":133,"correct":22},{"id":261,"libraryId":5,"type":126,"typeLabel":127,"stem":262,"options":263,"answer":131,"analysis":30},712447,"电力电缆跨越江、河、湖、海时,采用水底或桥上敷设。()",[264,265],{"key":20,"text":131,"correct":22},{"key":24,"text":133,"correct":26},{"id":267,"libraryId":5,"type":126,"typeLabel":127,"stem":268,"options":269,"answer":133,"analysis":30},712448,"电力电缆竖井敷设时,竖井内每隔10m设工作平台。()",[270,271],{"key":20,"text":131,"correct":26},{"key":24,"text":133,"correct":22},{"id":273,"libraryId":5,"type":126,"typeLabel":127,"stem":274,"options":275,"answer":131,"analysis":30},712449,"对于10kV电压等级单芯电缆,不论其导体截面大小,采用相同的绝缘厚度。()",[276,277],{"key":20,"text":131,"correct":22},{"key":24,"text":133,"correct":26},{"id":279,"libraryId":5,"type":126,"typeLabel":127,"stem":280,"options":281,"answer":131,"analysis":30},712450,"常用绿色表示70℃示温蜡片。()",[282,283],{"key":20,"text":131,"correct":22},{"key":24,"text":133,"correct":26},{"id":285,"libraryId":5,"type":126,"typeLabel":127,"stem":286,"options":287,"answer":131,"analysis":30},712451,"电缆接头成败的关键是电缆接头增绕绝缘和电场的处理。()",[288,289],{"key":20,"text":131,"correct":22},{"key":24,"text":133,"correct":26},{"id":291,"libraryId":5,"type":126,"typeLabel":127,"stem":292,"options":293,"answer":133,"analysis":30},712452,"电缆的电压等级越高,对耐压强度的要求越低。()",[294,295],{"key":20,"text":131,"correct":26},{"key":24,"text":133,"correct":22},{"id":297,"libraryId":5,"type":126,"typeLabel":127,"stem":298,"options":299,"answer":133,"analysis":30},712453,"目前,国内使用的高压交联聚乙烯电缆终端的主要形式为电容锥终端。()",[300,301],{"key":20,"text":131,"correct":26},{"key":24,"text":133,"correct":22},{"id":303,"libraryId":5,"type":126,"typeLabel":127,"stem":304,"options":305,"answer":131,"analysis":30},712454,"电缆金属护套、接地屏蔽和绝缘屏蔽在电气上接通的中间接头称为直通接头。()",[306,307],{"key":20,"text":131,"correct":22},{"key":24,"text":133,"correct":26},{"id":309,"libraryId":5,"type":126,"typeLabel":127,"stem":310,"options":311,"answer":131,"analysis":30},712455,"油浸纸绝缘统包型电力电缆的绝缘线芯连同填料扭绞成圆形。()",[312,313],{"key":20,"text":131,"correct":22},{"key":24,"text":133,"correct":26},{"id":315,"libraryId":5,"type":126,"typeLabel":127,"stem":316,"options":317,"answer":131,"analysis":30},712456,"修复后的电缆外护套应做直流耐压或接地电阻试验。()",[318,319],{"key":20,"text":131,"correct":22},{"key":24,"text":133,"correct":26},{"id":321,"libraryId":5,"type":126,"typeLabel":127,"stem":322,"options":323,"answer":131,"analysis":30},712457,"电缆外护套的材料通常是聚氯乙烯或聚乙烯。()",[324,325],{"key":20,"text":131,"correct":22},{"key":24,"text":133,"correct":26},{"id":327,"libraryId":5,"type":126,"typeLabel":127,"stem":328,"options":329,"answer":131,"analysis":30},712458,"冷收缩中间接头,内、外屏蔽层和应力控制一体。()",[330,331],{"key":20,"text":131,"correct":22},{"key":24,"text":133,"correct":26},{"id":333,"libraryId":5,"type":126,"typeLabel":127,"stem":334,"options":335,"answer":133,"analysis":30},712459,"1kV五芯(3+2)聚氯乙烯绝缘电力电缆,3指3根相线,2指2根N线。()",[336,337],{"key":20,"text":131,"correct":26},{"key":24,"text":133,"correct":22},{"id":339,"libraryId":5,"type":126,"typeLabel":127,"stem":340,"options":341,"answer":133,"analysis":30},712460,"对敷设于空气中的电力电缆,选择截面时,规定的标准敷设温度为25℃。()",[342,343],{"key":20,"text":131,"correct":26},{"key":24,"text":133,"correct":22},{"id":345,"libraryId":5,"type":126,"typeLabel":127,"stem":346,"options":347,"answer":131,"analysis":30},712461,"自容式充油电力电缆利用压力油箱或重力油箱向电缆的绝缘层补充绝缘油,以消除温度变化时在绝缘层中形成气隙。()",[348,349],{"key":20,"text":131,"correct":22},{"key":24,"text":133,"correct":26},{"id":351,"libraryId":5,"type":126,"typeLabel":127,"stem":352,"options":353,"answer":131,"analysis":30},712462,"高压及超高压电缆在安装附件前,一定要充分地加热调直,防止以后的绝缘回缩。()",[354,355],{"key":20,"text":131,"correct":22},{"key":24,"text":133,"correct":26},{"id":357,"libraryId":5,"type":126,"typeLabel":127,"stem":358,"options":359,"answer":131,"analysis":30},712463,"电力电缆水底敷设时,应平放于水底。()",[360,361],{"key":20,"text":131,"correct":22},{"key":24,"text":133,"correct":26},{"id":363,"libraryId":5,"type":126,"typeLabel":127,"stem":364,"options":365,"answer":133,"analysis":30},712464,"铜芯、纸绝缘、分相铅包、钢带铠装、聚氯乙烯外护套电力电缆型号为ZQ22。",[366,367],{"key":20,"text":131,"correct":26},{"key":24,"text":133,"correct":22},[369,372,375,377,380,383],{"id":370,"name":371,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":373,"name":374,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":376,"name":374,"category":7,"favorite":8},336,{"id":378,"name":379,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":381,"name":382,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":384,"name":385,"category":7,"favorite":8},353,"(N1)叉车司机"]