[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-382-16":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":505},{"id":5,"name":6,"category":7,"favorite":8},382,"电力电缆","特种作业",0,16,50,1595,[13,31,41,51,61,71,78,88,98,108,118,128,138,148,158,165,175,185,195,204,214,224,234,244,254,264,274,284,294,303,313,323,333,343,353,360,367,377,387,397,406,416,426,436,446,456,465,475,485,495],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":30},712365,1,"单选题","对于110kV及以上电缆户内、外终端,一般()进行一次定期巡视检查。",[19,23,27],{"key":20,"text":21,"correct":22},"A","1个季度",true,{"key":24,"text":25,"correct":26},"B","1个月",false,{"key":28,"text":29,"correct":26},"C","1年","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":20,"analysis":30},712366,"绝缘测试时泄漏试验主要项目结果不合格,发现绝缘有重大缺陷威胁安全运行的电缆设备为()。",[35,37,39],{"key":20,"text":36,"correct":22},"三级设备",{"key":24,"text":38,"correct":26},"二级设备",{"key":28,"text":40,"correct":26},"一级设备",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":20,"analysis":30},712367,"在交流电压下,随电压作用时间增加,绝缘层击穿场强()。",[45,47,49],{"key":20,"text":46,"correct":22},"下降",{"key":24,"text":48,"correct":26},"不变",{"key":28,"text":50,"correct":26},"上升",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":24,"analysis":30},712368,"对于长距离电力电缆隧道敷设,一般每隔()应设一个人孔。",[55,57,59],{"key":20,"text":56,"correct":26},"50-100m",{"key":24,"text":58,"correct":22},"100-200m",{"key":28,"text":60,"correct":26},"100-150m",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":28,"analysis":30},712369,"模塑式终端一般用于()交联聚乙烯绝缘电缆。",[65,67,69],{"key":20,"text":66,"correct":26},"110kV及以上",{"key":24,"text":68,"correct":26},"110kV及以下",{"key":28,"text":70,"correct":22},"35kV及以下",{"id":72,"libraryId":5,"type":15,"typeLabel":16,"stem":73,"options":74,"answer":24,"analysis":30},712370,"预制式终端一般用于()塑料绝缘电缆。",[75,76,77],{"key":20,"text":68,"correct":26},{"key":24,"text":70,"correct":22},{"key":28,"text":66,"correct":26},{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":24,"analysis":30},712371,"油浸纸绝缘电缆的优点是()。",[82,84,86],{"key":20,"text":83,"correct":26},"弹性好",{"key":24,"text":85,"correct":22},"价格低",{"key":28,"text":87,"correct":26},"耐热性好",{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":20,"analysis":30},712372,"直流闪络法能够测出()情况下的故障点距离。",[92,94,96],{"key":20,"text":93,"correct":22},"高阻接地",{"key":24,"text":95,"correct":26},"故障点处形成贯穿性通道",{"key":28,"text":97,"correct":26},"低阻接地",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":20,"analysis":30},712373,"热收缩部件收缩前与在非限制条件下收缩后纵向变化率应不大于()。",[102,104,106],{"key":20,"text":103,"correct":22},"5%",{"key":24,"text":105,"correct":26},"1%",{"key":28,"text":107,"correct":26},"50%",{"id":109,"libraryId":5,"type":15,"typeLabel":16,"stem":110,"options":111,"answer":20,"analysis":30},712374,"电力电缆排管敷设的优点之一是()。",[112,114,116],{"key":20,"text":113,"correct":22},"不用开挖路面",{"key":24,"text":115,"correct":26},"散热好",{"key":28,"text":117,"correct":26},"造价适中",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":28,"analysis":30},712375,"在室外存放充油电缆时,应有(),防止太阳直接照射。",[122,124,126],{"key":20,"text":123,"correct":26},"防雨苫布",{"key":24,"text":125,"correct":26},"专用箱子",{"key":28,"text":127,"correct":22},"遮阳蓬",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":20,"analysis":30},712376,"油浸纸绝缘统包型电力电缆敷设有较大落差时,其绝缘()。",[132,134,136],{"key":20,"text":133,"correct":22},"水平下降",{"key":24,"text":135,"correct":26},"不受影响",{"key":28,"text":137,"correct":26},"寿命延长",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":24,"analysis":30},712377,"电缆终端处沿电缆长度方向的电场,在靠近()处最大。",[142,144,146],{"key":20,"text":143,"correct":26},"线芯边缘",{"key":24,"text":145,"correct":22},"铅套边缘",{"key":28,"text":147,"correct":26},"绝缘层边缘",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":28,"analysis":30},712378,"电缆电压等级的表示由两个数值构成并以斜杠分开,斜杠后面数值是()。",[152,154,156],{"key":20,"text":153,"correct":26},"相电压",{"key":24,"text":155,"correct":26},"绝缘水平",{"key":28,"text":157,"correct":22},"线电压",{"id":159,"libraryId":5,"type":15,"typeLabel":16,"stem":160,"options":161,"answer":28,"analysis":30},712379,"在直流电压下,电缆绝缘层击穿场强随温度上升而()。",[162,163,164],{"key":20,"text":48,"correct":26},{"key":24,"text":50,"correct":26},{"key":28,"text":46,"correct":22},{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":28,"analysis":30},712380,"直埋10kV电缆相互水平接近时的最小净距为()。",[169,171,173],{"key":20,"text":170,"correct":26},"0.5m",{"key":24,"text":172,"correct":26},"0.2m",{"key":28,"text":174,"correct":22},"0.1m",{"id":176,"libraryId":5,"type":15,"typeLabel":16,"stem":177,"options":178,"answer":28,"analysis":30},712381,"在直流电压下,电场分布合理,电缆绝缘层气隙承受场强()。",[179,181,183],{"key":20,"text":180,"correct":26},"极小",{"key":24,"text":182,"correct":26},"较大",{"key":28,"text":184,"correct":22},"较小",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":20,"analysis":30},712382,"在运行中,电流的热量和电火花或()等都是电气火灾的直接原因。",[189,191,193],{"key":20,"text":190,"correct":22},"、电弧",{"key":24,"text":192,"correct":26},"、电压高低",{"key":28,"text":194,"correct":26},"、环境温度",{"id":196,"libraryId":5,"type":15,"typeLabel":16,"stem":197,"options":198,"answer":28,"analysis":30},712383,"由于集肤效应的存在,导体的交流电阻()。",[199,200,202],{"key":20,"text":135,"correct":26},{"key":24,"text":201,"correct":26},"减小",{"key":28,"text":203,"correct":22},"增大",{"id":205,"libraryId":5,"type":15,"typeLabel":16,"stem":206,"options":207,"answer":24,"analysis":30},712384,"电缆支架()有良好的接地。",[208,210,212],{"key":20,"text":209,"correct":26},"不需要",{"key":24,"text":211,"correct":22},"全线应",{"key":28,"text":213,"correct":26},"局部应",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":24,"analysis":30},712385,"设备的防触电保护不仅靠基本绝缘,还具有像双重绝缘或加强绝缘这样的附加安全措施。这样的设备属于()设备。",[218,220,222],{"key":20,"text":219,"correct":26},"I类",{"key":24,"text":221,"correct":22},"Ⅱ类",{"key":28,"text":223,"correct":26},"Ⅲ类",{"id":225,"libraryId":5,"type":15,"typeLabel":16,"stem":226,"options":227,"answer":20,"analysis":30},712386,"电力电缆排管敷设时,管径应不小于()。",[228,230,232],{"key":20,"text":229,"correct":22},"100mm",{"key":24,"text":231,"correct":26},"150mm",{"key":28,"text":233,"correct":26},"200mm",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":24,"analysis":30},712387,"用于连接不同芯数电缆的中间接头是()。",[238,240,242],{"key":20,"text":239,"correct":26},"过渡接头",{"key":24,"text":241,"correct":22},"转换接头",{"key":28,"text":243,"correct":26},"绝缘接头",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":28,"analysis":30},712388,"测温光纤每隔()装设标签,标明起点、终点、距离。",[248,250,252],{"key":20,"text":249,"correct":26},"1000m",{"key":24,"text":251,"correct":26},"800m",{"key":28,"text":253,"correct":22},"500m",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":24,"analysis":30},712389,"吊装作业时与220kV带电物体的距离不小于()。",[258,260,262],{"key":20,"text":259,"correct":26},"2m",{"key":24,"text":261,"correct":22},"6m",{"key":28,"text":263,"correct":26},"4m",{"id":265,"libraryId":5,"type":15,"typeLabel":16,"stem":266,"options":267,"answer":24,"analysis":30},712390,"与热收缩电缆终端相比,预制式电缆终端的弹性()。",[268,270,272],{"key":20,"text":269,"correct":26},"基本相同",{"key":24,"text":271,"correct":22},"更强",{"key":28,"text":273,"correct":26},"较差",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":24,"analysis":30},712391,"传统的配电网,特别是农村电网多为()。",[278,280,282],{"key":20,"text":279,"correct":26},"网格状",{"key":24,"text":281,"correct":22},"放射性树状网",{"key":28,"text":283,"correct":26},"环网",{"id":285,"libraryId":5,"type":15,"typeLabel":16,"stem":286,"options":287,"answer":24,"analysis":30},712392,"长度较长、输送容量较小的单相交流电力电缆的接地方式宜采用()。",[288,290,292],{"key":20,"text":289,"correct":26},"一端直接接地,一端加保护器接地",{"key":24,"text":291,"correct":22},"两端直接接地",{"key":28,"text":293,"correct":26},"两端加保护器接地",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":28,"analysis":30},712393,"在中性点直接接地系统中,油浸纸绝缘统包型电力电缆的统包层厚度()。",[298,300,301],{"key":20,"text":299,"correct":26},"较厚",{"key":24,"text":48,"correct":26},{"key":28,"text":302,"correct":22},"较薄",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":28,"analysis":30},712394,"由输配电线路及其所联系起来的各类变电站总称为()。",[307,309,311],{"key":20,"text":308,"correct":26},"电力系统",{"key":24,"text":310,"correct":26},"动力系统",{"key":28,"text":312,"correct":22},"电力网",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":24,"analysis":30},712395,"电缆线芯截面在()以下时,线芯可采用单股实心导体。",[317,319,321],{"key":20,"text":318,"correct":26},"15m㎡",{"key":24,"text":320,"correct":22},"35m㎡",{"key":28,"text":322,"correct":26},"25m㎡",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":28,"analysis":30},712396,"交联聚乙烯绝缘电缆在长期运行中,周围化学溶液渗入电缆内部,与金属发生化学反应,形成有腐蚀性硫化物,最终导致绝缘击穿的现象,称为()。",[327,329,331],{"key":20,"text":328,"correct":26},"水树枝",{"key":24,"text":330,"correct":26},"电树枝",{"key":28,"text":332,"correct":22},"电化树枝",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":28,"analysis":30},712397,"电缆竣工图比例尺宜为()。",[337,339,341],{"key":20,"text":338,"correct":26},"1:100",{"key":24,"text":340,"correct":26},"1:200",{"key":28,"text":342,"correct":22},"1:500",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":24,"analysis":30},712398,"为控制整体运输高度,将拖车平板放置电缆盘的位置改装,电缆盘可凹下平板的拖车,称为()。",[347,349,351],{"key":20,"text":348,"correct":26},"放缆拖车",{"key":24,"text":350,"correct":22},"元宝车",{"key":28,"text":352,"correct":26},"电缆运输机",{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":20,"analysis":30},712399,"绝缘测试时泄漏试验次要项目结果不合格,发现绝缘有缺陷但暂不影响安全运行的电缆设备为()。",[357,358,359],{"key":20,"text":38,"correct":22},{"key":24,"text":40,"correct":26},{"key":28,"text":36,"correct":26},{"id":361,"libraryId":5,"type":15,"typeLabel":16,"stem":362,"options":363,"answer":28,"analysis":30},712400,"对于电缆绝缘,在直流电压下,负载增大时,导体屏蔽表面场强()。",[364,365,366],{"key":20,"text":203,"correct":26},{"key":24,"text":48,"correct":26},{"key":28,"text":201,"correct":22},{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":28,"analysis":30},712401,"填充SF6气体绝缘变压器终端的外绝缘SF6气体压力通常为()。",[371,373,375],{"key":20,"text":372,"correct":26},"0.25MPa",{"key":24,"text":374,"correct":26},"0.3MPa",{"key":28,"text":376,"correct":22},"0.4MPa",{"id":378,"libraryId":5,"type":15,"typeLabel":16,"stem":379,"options":380,"answer":28,"analysis":30},712402,"电缆的老化曲线是指()与时间的关系。",[381,383,385],{"key":20,"text":382,"correct":26},"载流量",{"key":24,"text":384,"correct":26},"温度",{"key":28,"text":386,"correct":22},"绝缘性能",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":20,"analysis":30},712403,"外充气钢管电缆采用()绞合导体。",[391,393,395],{"key":20,"text":392,"correct":22},"椭圆形",{"key":24,"text":394,"correct":26},"圆形",{"key":28,"text":396,"correct":26},"中空圆形",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":20,"analysis":30},712404,"整体式预制型直通接头和绝缘接头中,主要区别在于()两侧铜保护壳之间装有绝缘子或绝缘衬垫。",[401,402,404],{"key":20,"text":243,"correct":22},{"key":24,"text":403,"correct":26},"两种接头均有",{"key":28,"text":405,"correct":26},"直通接头",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":24,"analysis":30},712405,"直埋电缆的敷设方式适合于()的区域。",[410,412,414],{"key":20,"text":411,"correct":26},"电缆根数多",{"key":24,"text":413,"correct":22},"地下无障碍",{"key":28,"text":415,"correct":26},"交通频繁",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":28,"analysis":30},712406,"冷收缩式电缆终端具有()性能。",[420,422,424],{"key":20,"text":421,"correct":26},"导热性",{"key":24,"text":423,"correct":26},"抗紫外线",{"key":28,"text":425,"correct":22},"抗电晕耐腐蚀",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":20,"analysis":30},712407,"安装有保护器的单芯电缆,通过()后,应定期检查阀片有无击穿或烧熔现象。",[430,432,434],{"key":20,"text":431,"correct":22},"短路电流",{"key":24,"text":433,"correct":26},"过负荷电流",{"key":28,"text":435,"correct":26},"正常工作电流",{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":20,"analysis":30},712408,"电缆护层材料必须密封性、防腐性好,并应有足够的()。",[440,442,444],{"key":20,"text":441,"correct":22},"机械强度",{"key":24,"text":443,"correct":26},"导电性",{"key":28,"text":445,"correct":26},"导磁性",{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":24,"analysis":30},712409,"电缆穿过竖井、墙壁、楼板或进入电气盘、柜的孔洞处,应()。",[450,452,454],{"key":20,"text":451,"correct":26},"保持畅通通风",{"key":24,"text":453,"correct":22},"用防火堵料密实封堵",{"key":28,"text":455,"correct":26},"设置通风冷却装置",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":20,"analysis":30},712410,"引发电气火灾要具备的两个条件为:现场有()和现场有引燃条件。",[460,462,464],{"key":20,"text":461,"correct":22},"可燃物质",{"key":24,"text":463,"correct":26},"湿度",{"key":28,"text":384,"correct":26},{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":20,"analysis":30},712411,"我国电力系统中,纯粹的电缆线路不装设()。",[469,471,473],{"key":20,"text":470,"correct":22},"重合闸",{"key":24,"text":472,"correct":26},"继电保护",{"key":28,"text":474,"correct":26},"负荷开关",{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":28,"analysis":30},712412,"绝缘接头是指电缆()在电气上断开。",[479,481,483],{"key":20,"text":480,"correct":26},"仅金属护套",{"key":24,"text":482,"correct":26},"仅金属护套、接地屏蔽",{"key":28,"text":484,"correct":22},"金属护套、接地屏蔽和绝缘屏蔽",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":20,"analysis":30},712413,"集肤效应系数的大小主要与()有关。",[489,491,493],{"key":20,"text":490,"correct":22},"线芯结构",{"key":24,"text":492,"correct":26},"线芯间距",{"key":28,"text":494,"correct":26},"线芯长度",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":28,"analysis":30},712414,"XLPE绝缘电缆具有热屏障作用,因为半导电屏蔽层具有()。",[499,501,503],{"key":20,"text":500,"correct":26},"一定的电导",{"key":24,"text":502,"correct":26},"一定的电抗",{"key":28,"text":504,"correct":22},"一定的热阻",[506,509,512,514,517,520],{"id":507,"name":508,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":510,"name":511,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":513,"name":511,"category":7,"favorite":8},336,{"id":515,"name":516,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":518,"name":519,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":521,"name":522,"category":7,"favorite":8},353,"(N1)叉车司机"]