[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-382-15":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":518},{"id":5,"name":6,"category":7,"favorite":8},382,"电力电缆","特种作业",0,15,50,1595,[13,31,41,51,61,71,81,91,101,111,121,131,141,151,161,171,181,191,201,210,220,230,240,250,260,270,279,289,299,309,319,329,339,349,359,369,379,389,398,408,418,428,438,448,458,468,478,488,498,508],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":30},712315,1,"单选题","不适合在有严重腐蚀环境敷设的电缆是()。",[19,23,27],{"key":20,"text":21,"correct":22},"A","ZLQD02",false,{"key":24,"text":25,"correct":26},"B","ZQD20",true,{"key":28,"text":29,"correct":22},"C","ZQD02","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":20,"analysis":30},712316,"在电缆可能受到机械损伤,距地面高度2m以下的一段电缆需要()。",[35,37,39],{"key":20,"text":36,"correct":26},"穿保护管",{"key":24,"text":38,"correct":22},"直接引下",{"key":28,"text":40,"correct":22},"垫缓冲物",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":20,"analysis":30},712317,"中压电力电缆是指()电压等级的电缆。",[45,47,49],{"key":20,"text":46,"correct":26},"6-35kV",{"key":24,"text":48,"correct":22},"110kV",{"key":28,"text":50,"correct":22},"500kV",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":28,"analysis":30},712318,"对敷设于土壤的电力电缆,选择截面时,规定的标准敷设温度为()。",[55,57,59],{"key":20,"text":56,"correct":22},"40℃",{"key":24,"text":58,"correct":22},"30℃",{"key":28,"text":60,"correct":26},"25℃",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":20,"analysis":30},712319,"一般纸带沿表面击穿强度为垂直纸带方向的(),故局部放电最终导致树枝放电。",[65,67,69],{"key":20,"text":66,"correct":26},"1\u002F10",{"key":24,"text":68,"correct":22},"1\u002F2",{"key":28,"text":70,"correct":22},"2倍",{"id":72,"libraryId":5,"type":15,"typeLabel":16,"stem":73,"options":74,"answer":24,"analysis":30},712320,"吊装作业时与110kV带电物体的距离不小于()。",[75,77,79],{"key":20,"text":76,"correct":22},"2m",{"key":24,"text":78,"correct":26},"4m",{"key":28,"text":80,"correct":22},"6m",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":24,"analysis":30},712321,"铜芯、聚氯乙烯绝缘、钢带铠装、聚氯乙烯外护套电力电缆型号为()。",[85,87,89],{"key":20,"text":86,"correct":22},"VLV22",{"key":24,"text":88,"correct":26},"VV22",{"key":28,"text":90,"correct":22},"YV22",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":24,"analysis":30},712322,"电缆终端处最大径向场强取值越小,终端头的体积(),电气安全裕度越大。",[95,97,99],{"key":20,"text":96,"correct":22},"越小",{"key":24,"text":98,"correct":26},"越大",{"key":28,"text":100,"correct":22},"不变",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":24,"analysis":30},712323,"超高压电力电缆是指()电压等级的电缆。",[105,107,109],{"key":20,"text":106,"correct":22},"110~220kVB",{"key":24,"text":108,"correct":26},"220-500kV",{"key":28,"text":110,"correct":22},"35-110kV",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":24,"analysis":30},712324,"对于电缆的高阻故障,一般采用()定点。",[115,117,119],{"key":20,"text":116,"correct":22},"脉冲反射法",{"key":24,"text":118,"correct":26},"声测法",{"key":28,"text":120,"correct":22},"音频感应法",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":24,"analysis":30},712325,"粘贴示温蜡片测量温度能()。",[125,127,129],{"key":20,"text":126,"correct":22},"准确反映粘贴处温度",{"key":24,"text":128,"correct":26},"粗略反映粘贴处温度范围",{"key":28,"text":130,"correct":22},"近似反映粘贴处温度",{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":20,"analysis":30},712326,"在直流电压下,绝缘层电压分配与绝缘电阻()。",[135,137,139],{"key":20,"text":136,"correct":26},"成正比",{"key":24,"text":138,"correct":22},"成反比",{"key":28,"text":140,"correct":22},"无关",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":20,"analysis":30},712327,"电缆水分在线监测系统是在电缆结构中内置一个分布式的(),通过测量其直流电阻来判断水分的侵入情况。",[145,147,149],{"key":20,"text":146,"correct":26},"水传感器",{"key":24,"text":148,"correct":22},"光纤传感器",{"key":28,"text":150,"correct":22},"激光传感器",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":20,"analysis":30},712328,"ZQ02和ZLQ02型电缆能敷设于()环境。",[155,157,159],{"key":20,"text":156,"correct":26},"严重腐蚀",{"key":24,"text":158,"correct":22},"土壤",{"key":28,"text":160,"correct":22},"水下",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":28,"analysis":30},712329,"不能承受较大拉力的电缆是()。",[165,167,169],{"key":20,"text":166,"correct":22},"ZQD32",{"key":24,"text":168,"correct":22},"VV42",{"key":28,"text":170,"correct":26},"ZQD22",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":20,"analysis":30},712330,"110kV交联聚乙烯电缆的绝缘标称厚度为()。",[175,177,179],{"key":20,"text":176,"correct":26},"17mm",{"key":24,"text":178,"correct":22},"14mm",{"key":28,"text":180,"correct":22},"21mm",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":28,"analysis":30},712331,"电缆线路试运行阶段,需要进行一些必要的检查,作为对()的补充。",[185,187,189],{"key":20,"text":186,"correct":22},"自验收工作",{"key":24,"text":188,"correct":22},"中期验收工作",{"key":28,"text":190,"correct":26},"竣工验收工作",{"id":192,"libraryId":5,"type":15,"typeLabel":16,"stem":193,"options":194,"answer":28,"analysis":30},712332,"电缆线路工程验收各阶段完成后必须填写()。",[195,197,199],{"key":20,"text":196,"correct":22},"施工记录",{"key":24,"text":198,"correct":22},"安全记录",{"key":28,"text":200,"correct":26},"阶段验收记录和整改记录",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":24,"analysis":30},712333,"为减小电缆的中间接头反应力锥面上的爬电危险,应要求切向场强()。",[205,206,208],{"key":20,"text":100,"correct":22},{"key":24,"text":207,"correct":26},"减小",{"key":28,"text":209,"correct":22},"增大",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":20,"analysis":30},712334,"电缆线芯截面的形状目前有()。",[214,216,218],{"key":20,"text":215,"correct":26},"圆形、椭圆形、中空圆形、扇形4种",{"key":24,"text":217,"correct":22},"圆形、椭圆形、扇形3种",{"key":28,"text":219,"correct":22},"圆形、扇形2种",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":28,"analysis":30},712335,"进行电缆线芯导通试验的方法是,()。",[224,226,228],{"key":20,"text":225,"correct":22},"用万能表分别在三相电缆首端测量线芯电阻",{"key":24,"text":227,"correct":22},"将电缆末端三相线芯短接,用万能表在电缆末端测量线芯电阻",{"key":28,"text":229,"correct":26},"将电缆末端三相线芯短接,用万能表在电缆首端测量线芯电阻",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":28,"analysis":30},712336,"当导体为圆形时,多芯统包型电缆的最大电场强度在()。",[234,236,238],{"key":20,"text":235,"correct":22},"线芯中心连接线与屏蔽层表面的交点上",{"key":24,"text":237,"correct":22},"线芯中心连接线与绝缘层表面的交点上",{"key":28,"text":239,"correct":26},"线芯中心连接线与线芯表面的交点上",{"id":241,"libraryId":5,"type":15,"typeLabel":16,"stem":242,"options":243,"answer":28,"analysis":30},712337,"电缆线芯采用多股导线单丝绞合有利于()。",[244,246,248],{"key":20,"text":245,"correct":22},"减小电缆重量",{"key":24,"text":247,"correct":22},"制造工艺简单化",{"key":28,"text":249,"correct":26},"增加电缆柔性",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":28,"analysis":30},712338,"油浸纸绝缘分相铅包电力电缆适合用于()电压等级。",[254,256,258],{"key":20,"text":255,"correct":22},"10kV及以下",{"key":24,"text":257,"correct":22},"110kV及以上",{"key":28,"text":259,"correct":26},"20-35kV",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":28,"analysis":30},712339,"电能以电磁波形式传播,传播速度是()。",[264,266,268],{"key":20,"text":265,"correct":22},"风速",{"key":24,"text":267,"correct":22},"声速",{"key":28,"text":269,"correct":26},"光速",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":24,"analysis":30},712340,"直埋电缆与热力管道接近时,应保持的最小净距为()。",[274,276,277],{"key":20,"text":275,"correct":22},"0.5m",{"key":24,"text":76,"correct":26},{"key":28,"text":278,"correct":22},"1m",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":20,"analysis":30},712341,"一般地,取电缆终端绝缘材料界面上的最大轴向场强为()。",[283,285,287],{"key":20,"text":284,"correct":26},"0.35-0.55kV\u002Fmm",{"key":24,"text":286,"correct":22},"0.05-0.1kV\u002Fmm",{"key":28,"text":288,"correct":22},"0.75-0.85kV\u002Fmm",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":28,"analysis":30},712342,"若电缆终端示温蜡片熔化,但接点的金属未变色,则()。",[293,295,297],{"key":20,"text":294,"correct":22},"申请紧急停电",{"key":24,"text":296,"correct":22},"不必申请停电",{"key":28,"text":298,"correct":26},"申请正常停电",{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":24,"analysis":30},712343,"温度测量数据要与()进行比较,不应有较大差异。",[303,305,307],{"key":20,"text":304,"correct":22},"往年同期平均环境温度",{"key":24,"text":306,"correct":26},"当时环境温度",{"key":28,"text":308,"correct":22},"当年平均环境温度",{"id":310,"libraryId":5,"type":15,"typeLabel":16,"stem":311,"options":312,"answer":28,"analysis":30},712344,"1kV三芯聚氯乙烯绝缘电力电缆的结构中不含()。",[313,315,317],{"key":20,"text":314,"correct":22},"钢带铠装",{"key":24,"text":316,"correct":22},"聚氯乙烯绝缘层",{"key":28,"text":318,"correct":26},"中性导体",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":24,"analysis":30},712345,"电力电缆水底平行敷设时,间距不宜小于()。",[323,325,327],{"key":20,"text":324,"correct":22},"最低水位水深的2倍",{"key":24,"text":326,"correct":26},"最高水位水深的2倍",{"key":28,"text":328,"correct":22},"最高水位水深的1.5倍",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":24,"analysis":30},712346,"用仪器测量电缆各部位温度,目的是防止电缆绝缘超过允许最高温度而()。",[333,335,337],{"key":20,"text":334,"correct":22},"变色",{"key":24,"text":336,"correct":26},"缩短寿命",{"key":28,"text":338,"correct":22},"击穿损坏",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":24,"analysis":30},712347,"电缆发生单相接地故障后,修复方法是()。",[343,345,347],{"key":20,"text":344,"correct":22},"包缠10层绝缘自粘带",{"key":24,"text":346,"correct":26},"加添一个假接头",{"key":28,"text":348,"correct":22},"重新连接线芯",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":20,"analysis":30},712348,"电力系统中,应用最多的电缆是()。",[353,355,357],{"key":20,"text":354,"correct":26},"电力电缆和控制电缆",{"key":24,"text":356,"correct":22},"通信电缆",{"key":28,"text":358,"correct":22},"通信电缆和控制电缆",{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":28,"analysis":30},712349,"电缆采用铝包的优点是()。",[363,365,367],{"key":20,"text":364,"correct":22},"不易腐蚀",{"key":24,"text":366,"correct":22},"易密封",{"key":28,"text":368,"correct":26},"资源丰富",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":28,"analysis":30},712350,"防火分隔和封堵是()的重要措施。",[373,375,377],{"key":20,"text":374,"correct":22},"预防电缆着火",{"key":24,"text":376,"correct":22},"发生火灾后灭火",{"key":28,"text":378,"correct":26},"限制火灾范围",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":28,"analysis":30},712351,"对于绕包型电缆,改善铅包口电场分布的有效措施是()。",[383,385,387],{"key":20,"text":384,"correct":22},"反应力锥",{"key":24,"text":386,"correct":22},"应力锥",{"key":28,"text":388,"correct":26},"胀铅",{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":28,"analysis":30},712352,"为减小电缆的中间接头反应力锥的爬电危险,要求切向场强最大值为()。",[393,394,396],{"key":20,"text":286,"correct":22},{"key":24,"text":395,"correct":22},"0.3-0.4kV\u002Fmm",{"key":28,"text":397,"correct":26},"0.1-0.3kV\u002Fmm",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":20,"analysis":30},712353,"电力电缆排管敷设时,应采用()。",[402,404,406],{"key":20,"text":403,"correct":26},"塑料护套电缆",{"key":24,"text":405,"correct":22},"一般裸铅包电缆",{"key":28,"text":407,"correct":22},"金属护套电缆",{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":410,"options":411,"answer":24,"analysis":30},712354,"电缆金属护套破损,属于电缆()。",[412,414,416],{"key":20,"text":413,"correct":22},"接头缺陷",{"key":24,"text":415,"correct":26},"本体缺陷",{"key":28,"text":417,"correct":22},"终端缺陷",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":20,"analysis":30},712355,"一般地,XLPE电缆局部放电在线监测主要针对()。",[422,424,426],{"key":20,"text":423,"correct":26},"电缆附件",{"key":24,"text":425,"correct":22},"电缆本体",{"key":28,"text":427,"correct":22},"电缆线路全线",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":28,"analysis":30},712356,"移动运行中的电缆,应()。",[432,434,436],{"key":20,"text":433,"correct":22},"使用绝缘杆",{"key":24,"text":435,"correct":22},"带安全帽",{"key":28,"text":437,"correct":26},"带绝缘手套",{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":24,"analysis":30},712357,"电缆铠装的作用是()。",[442,444,446],{"key":20,"text":443,"correct":22},"防潮",{"key":24,"text":445,"correct":26},"防机械外力损伤内护套",{"key":28,"text":447,"correct":22},"防腐蚀",{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":24,"analysis":30},712358,"树枝老化是导致()电缆绝缘发生击穿的主要原因。",[452,454,456],{"key":20,"text":453,"correct":22},"油浸纸绝缘",{"key":24,"text":455,"correct":26},"交联聚乙烯",{"key":28,"text":457,"correct":22},"充油",{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":24,"analysis":30},712359,"为了降低电缆火灾时的毒性,有些电缆的外护套采用()。",[462,464,466],{"key":20,"text":463,"correct":22},"阻燃剂",{"key":24,"text":465,"correct":26},"阻燃型聚烯烃材料",{"key":28,"text":467,"correct":22},"阻燃型聚氯乙烯",{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":28,"analysis":30},712360,"电缆揉动、弯曲可能造成热缩部件脱开形成气隙而引起局部放电的是()终端。",[472,474,476],{"key":20,"text":473,"correct":22},"预制式",{"key":24,"text":475,"correct":22},"冷收缩式",{"key":28,"text":477,"correct":26},"热收缩式",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":28,"analysis":30},712361,"为保证电缆的绝缘部分能长期使用,其绝缘部分和接头附件需要()。",[482,484,486],{"key":20,"text":483,"correct":22},"敞露于空气中",{"key":24,"text":485,"correct":22},"加装套管绝缘",{"key":28,"text":487,"correct":26},"加以密封保护",{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":24,"analysis":30},712362,"同一层支架上电缆排列配置方式,应符合()。",[492,494,496],{"key":20,"text":493,"correct":22},"35kV电力电缆和控制电缆可紧靠",{"key":24,"text":495,"correct":26},"控制电缆和信号电缆可紧靠",{"key":28,"text":497,"correct":22},"35kV电力电缆和信号电缆可紧靠",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":20,"analysis":30},712363,"与组装式相比,整体式预制型电缆中间接头现场安装工艺()。",[502,504,506],{"key":20,"text":503,"correct":26},"简单",{"key":24,"text":505,"correct":22},"基本相同",{"key":28,"text":507,"correct":22},"复杂",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":24,"analysis":30},712364,"电缆在桥上架设时,除对其金属护层有绝缘要求外,还应与桥梁钢架()。",[512,514,516],{"key":20,"text":513,"correct":22},"保持绝缘",{"key":24,"text":515,"correct":26},"进行电气连接接地",{"key":28,"text":517,"correct":22},"保持机械连接",[519,522,525,527,530,533],{"id":520,"name":521,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":523,"name":524,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":526,"name":524,"category":7,"favorite":8},336,{"id":528,"name":529,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":531,"name":532,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":534,"name":535,"category":7,"favorite":8},353,"(N1)叉车司机"]