[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-382-14":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":524},{"id":5,"name":6,"category":7,"favorite":8},382,"电力电缆","特种作业",0,14,50,1595,[13,31,41,51,61,71,81,91,101,111,121,131,141,151,161,171,181,191,201,211,221,231,241,251,261,271,281,291,301,311,321,331,341,351,361,371,381,391,401,411,421,431,444,454,464,474,484,494,504,514],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":30},712265,1,"单选题","对安装在室内电缆沟内的电缆,可采用()的方法限制电晕发生。",[19,23,27],{"key":20,"text":21,"correct":22},"A","增加水蒸汽",false,{"key":24,"text":25,"correct":26},"B","提高空气干燥度",true,{"key":28,"text":29,"correct":22},"C","设置封堵","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":28,"analysis":30},712266,"电路中的谐波含量造成感应式电度表计量不准确,因为存在负的()。",[35,37,39],{"key":20,"text":36,"correct":22},"电流误差",{"key":24,"text":38,"correct":22},"电压误差",{"key":28,"text":40,"correct":26},"频率误差",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":20,"analysis":30},712267,"电缆接地线或交叉互联线接线错误会造成()过大而烧毁电缆或附件。",[45,47,49],{"key":20,"text":46,"correct":26},"环流",{"key":24,"text":48,"correct":22},"泄漏电流",{"key":28,"text":50,"correct":22},"线芯电流",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":28,"analysis":30},712268,"短距离滚动搬运电缆盘时,可()滚动。",[55,57,59],{"key":20,"text":56,"correct":22},"任意方向",{"key":24,"text":58,"correct":22},"逆着电缆缠绕方向",{"key":28,"text":60,"correct":26},"顺着电缆缠绕方向",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":24,"analysis":30},712269,"铜芯、纸绝缘、铅包、钢带铠装、聚氯乙烯外护套电力电缆型号为()。",[65,67,69],{"key":20,"text":66,"correct":22},"ZLQ22",{"key":24,"text":68,"correct":26},"ZQ22",{"key":28,"text":70,"correct":22},"ZQ21",{"id":72,"libraryId":5,"type":15,"typeLabel":16,"stem":73,"options":74,"answer":24,"analysis":30},712270,"采用在线芯绝缘表面包金属屏蔽带(等电位)的方法,可限制()电晕发生。",[75,77,79],{"key":20,"text":76,"correct":22},"预制型电缆终端",{"key":24,"text":78,"correct":26},"干包或热缩型电缆终端",{"key":28,"text":80,"correct":22},"冷缩型电缆终端",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":24,"analysis":30},712271,"说明工程中电缆走向的地理位置的图纸,称为()。",[85,87,89],{"key":20,"text":86,"correct":22},"电气接线图",{"key":24,"text":88,"correct":26},"电缆路径示意图",{"key":28,"text":90,"correct":22},"电缆接地示意图",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":24,"analysis":30},712272,"隧道内电缆中间接头两侧和中间()。",[95,97,99],{"key":20,"text":96,"correct":22},"增加软固定",{"key":24,"text":98,"correct":26},"增加硬固定",{"key":28,"text":100,"correct":22},"不加固定",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":20,"analysis":30},712273,"电缆型号YJV22-8.7\u002F10-3×240-600-GB12706.3表示其额定电压为()。",[105,107,109],{"key":20,"text":106,"correct":26},"8.7\u002F10kV",{"key":24,"text":108,"correct":22},"240V",{"key":28,"text":110,"correct":22},"600V",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":24,"analysis":30},712274,"对于交联聚乙烯绝缘电缆,由于导体表面的毛刺和突起、绝缘层中杂质等形成绝缘层中电场分布畸变,导致绝缘树枝状老化的现象,称为()。",[115,117,119],{"key":20,"text":116,"correct":22},"水树枝",{"key":24,"text":118,"correct":26},"电树枝",{"key":28,"text":120,"correct":22},"电化树枝",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":24,"analysis":30},712275,"电力电缆工程设计中入网电工所接触的是()阶段。",[125,127,129],{"key":20,"text":126,"correct":22},"可行性研究",{"key":24,"text":128,"correct":26},"施工图设计",{"key":28,"text":130,"correct":22},"初步设计",{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":20,"analysis":30},712276,"在有比空气重的爆炸性介质和火灾危险场所进行电缆沟道敷设时,应采用()。",[135,137,139],{"key":20,"text":136,"correct":26},"充沙电缆沟",{"key":24,"text":138,"correct":22},"普通电缆沟",{"key":28,"text":140,"correct":22},"塑料壁电缆沟",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":24,"analysis":30},712277,"一般缺陷应列入检修计划,并于()组织检修处理。",[145,147,149],{"key":20,"text":146,"correct":22},"当日及时",{"key":24,"text":148,"correct":26},"三个月内",{"key":28,"text":150,"correct":22},"一个月内尽快",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":24,"analysis":30},712278,"对于负荷密集区的市政主干道两侧,应沿道路建设()电缆路径。",[155,157,159],{"key":20,"text":156,"correct":22},"左侧",{"key":24,"text":158,"correct":26},"双侧",{"key":28,"text":160,"correct":22},"右侧",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":24,"analysis":30},712279,"电缆接头制成后允许弯曲呈弧形,并主要用于水底电缆的中间接头称为()。",[165,167,169],{"key":20,"text":166,"correct":22},"转换接头",{"key":24,"text":168,"correct":26},"软接头",{"key":28,"text":170,"correct":22},"塞止接头",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":20,"analysis":30},712280,"声测法进行故障定点的原理是利用()。",[175,177,179],{"key":20,"text":176,"correct":26},"放电的机械效应",{"key":24,"text":178,"correct":22},"发射声波的反射",{"key":28,"text":180,"correct":22},"电缆周围电磁场变化",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":28,"analysis":30},712281,"发生局部放电后,电力电缆长时间承受运行电压,会导致()。",[185,187,189],{"key":20,"text":186,"correct":22},"热击穿和化学击穿",{"key":24,"text":188,"correct":22},"化学击穿和电击穿",{"key":28,"text":190,"correct":26},"热击穿或电击穿",{"id":192,"libraryId":5,"type":15,"typeLabel":16,"stem":193,"options":194,"answer":28,"analysis":30},712282,"电缆线路工程验收必须按照()进行组织。",[195,197,199],{"key":20,"text":196,"correct":22},"中期验收和竣工验收2个阶段",{"key":24,"text":198,"correct":22},"初期验收、中期验收、竣工验收3个阶段",{"key":28,"text":200,"correct":26},"中间过程验收、自验收、预验收、竣工验收4个阶段",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":24,"analysis":30},712283,"电缆线路的负荷测量可用()。",[205,207,209],{"key":20,"text":206,"correct":22},"有功电度表",{"key":24,"text":208,"correct":26},"钳形电流表",{"key":28,"text":210,"correct":22},"有功功率表",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":24,"analysis":30},712284,"中性点直接接地系统且接地故障持续时间不超过1min,电缆电压等级包括()。",[215,217,219],{"key":20,"text":216,"correct":22},"1\u002F1",{"key":24,"text":218,"correct":26},"3.6\u002F6",{"key":28,"text":220,"correct":22},"26\u002F35",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":24,"analysis":30},712285,"在10kV电缆环网中,采用()代替分段器。",[225,227,229],{"key":20,"text":226,"correct":22},"少油开关",{"key":24,"text":228,"correct":26},"真空接触器或",{"key":28,"text":230,"correct":22},"多油开关",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":28,"analysis":30},712286,"电缆温度在线监测按照测温点的分布情况,分为()类。",[235,237,239],{"key":20,"text":236,"correct":22},"4",{"key":24,"text":238,"correct":22},"3",{"key":28,"text":240,"correct":26},"2",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":20,"analysis":30},712287,"在电缆型号中,导体材料如果是(),则表示字母可省略。",[245,247,249],{"key":20,"text":246,"correct":26},"铜",{"key":24,"text":248,"correct":22},"铝",{"key":28,"text":250,"correct":22},"铁",{"id":252,"libraryId":5,"type":15,"typeLabel":16,"stem":253,"options":254,"answer":24,"analysis":30},712288,"电缆线路的试运行阶段是指电缆线路投入运行后()以内。",[255,257,259],{"key":20,"text":256,"correct":22},"3个月",{"key":24,"text":258,"correct":26},"1年",{"key":28,"text":260,"correct":22},"6个月",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":20,"analysis":30},712289,"温度测量数据要结合负荷情况,与()进行比较,不应有较大差异。",[265,267,269],{"key":20,"text":266,"correct":26},"历年同期测量数据",{"key":24,"text":268,"correct":22},"当年测量数据平均值",{"key":28,"text":270,"correct":22},"当月不同负荷下测量数据",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":28,"analysis":30},712290,"黏性浸渍纸绝缘电缆,垂直落差较大时,高端浸渍剂流失,加速绝缘老化,称为()。",[275,277,279],{"key":20,"text":276,"correct":22},"局部放电",{"key":24,"text":278,"correct":22},"热老化",{"key":28,"text":280,"correct":26},"绝缘干枯",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":20,"analysis":30},712291,"对于110kV及以上等级的电缆,改善电缆终端处电场分布的有效措施是()。",[285,287,289],{"key":20,"text":286,"correct":26},"应力锥和反应力锥",{"key":24,"text":288,"correct":22},"胀铅",{"key":28,"text":290,"correct":22},"延长电缆末端裸露的绝缘长度",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":20,"analysis":30},712292,"目前,我国基本能生产制造并广泛使用()电压等级的电缆终端。",[295,297,299],{"key":20,"text":296,"correct":26},"35kV及以下",{"key":24,"text":298,"correct":22},"110kV",{"key":28,"text":300,"correct":22},"500kV",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":28,"analysis":30},712293,"整体式预制型电缆中间接头结构中采用()制成。",[305,307,309],{"key":20,"text":306,"correct":22},"多种不同材料",{"key":24,"text":308,"correct":22},"两种不同材料",{"key":28,"text":310,"correct":26},"单一的橡胶",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":24,"analysis":30},712294,"6kV聚氯乙烯绝缘电力电缆绝缘屏蔽层外的金属带屏蔽层的作用是()。",[315,317,319],{"key":20,"text":316,"correct":22},"电磁屏蔽",{"key":24,"text":318,"correct":26},"承受短路电流",{"key":28,"text":320,"correct":22},"使导体与绝缘层良好接触",{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":28,"analysis":30},712295,"冷缩电缆终端以()为基本材料。",[325,327,329],{"key":20,"text":326,"correct":22},"绝缘纸",{"key":24,"text":328,"correct":22},"聚合物",{"key":28,"text":330,"correct":26},"橡胶",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":28,"analysis":30},712296,"有些使用场合对电缆外护层的抗拉强度要求较高,如()。",[335,337,339],{"key":20,"text":336,"correct":22},"直埋地下",{"key":24,"text":338,"correct":22},"电缆沟",{"key":28,"text":340,"correct":26},"电缆竖井",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":28,"analysis":30},712297,"电缆油浸纸绝缘层内局部放电会逐渐加强并从一层纸带间隙沿纸面经另一层纸带间隙呈()地不断发展,最终导致整体击穿。",[345,347,349],{"key":20,"text":346,"correct":22},"阶梯形",{"key":24,"text":348,"correct":22},"直线形",{"key":28,"text":350,"correct":26},"螺旋形",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":20,"analysis":30},712298,"电缆的中间接头与终端接头在()方面有相同的要求。",[355,357,359],{"key":20,"text":356,"correct":26},"电应力控制",{"key":24,"text":358,"correct":22},"外皮接地",{"key":28,"text":360,"correct":22},"实现固定",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":20,"analysis":30},712299,"电力系统是由发电厂、()和用户组成的相互连接的整体。",[365,367,369],{"key":20,"text":366,"correct":26},"电力网",{"key":24,"text":368,"correct":22},"变电站",{"key":28,"text":370,"correct":22},"输配电线路",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":20,"analysis":30},712300,"电缆的金属护套被腐蚀过程的发展速度()。",[375,377,379],{"key":20,"text":376,"correct":26},"很慢",{"key":24,"text":378,"correct":22},"很快",{"key":28,"text":380,"correct":22},"中等",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":20,"analysis":30},712301,"电力电缆与小河或小溪交叉时,()。",[385,387,389],{"key":20,"text":386,"correct":26},"应穿管或埋入河床下足够深",{"key":24,"text":388,"correct":22},"应平放于水底",{"key":28,"text":390,"correct":22},"应悬于水中",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":20,"analysis":30},712302,"充油电缆油压报警系统故障,属于电缆()。",[395,397,399],{"key":20,"text":396,"correct":26},"线路附属设备缺陷",{"key":24,"text":398,"correct":22},"接头和终端缺陷",{"key":28,"text":400,"correct":22},"本体缺陷",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":24,"analysis":30},712303,"交流单芯电力电缆金属护套的感应电压与()无关。",[405,407,409],{"key":20,"text":406,"correct":22},"流过的电流大小",{"key":24,"text":408,"correct":26},"电缆的截面",{"key":28,"text":410,"correct":22},"电缆的长度",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":28,"analysis":30},712304,"对于充油电缆线路,(),都要检查其油压。",[415,417,419],{"key":20,"text":416,"correct":22},"投入运行前",{"key":24,"text":418,"correct":22},"投入运行后",{"key":28,"text":420,"correct":26},"无论是否投运",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":24,"analysis":30},712305,"110kV及以上XLPE电缆,用()对接地线电流采样,实现外护套的在线监测。",[425,427,429],{"key":20,"text":426,"correct":22},"电流表",{"key":24,"text":428,"correct":26},"电流互感器",{"key":28,"text":430,"correct":22},"电压互感器",{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":24,"analysis":30},712306,"某变电所得到电缆线路接地信号,运行人员判断:可能是()故障。",[435,437,439,441],{"key":20,"text":436,"correct":22},"两相短路",{"key":24,"text":438,"correct":26},"单相接地",{"key":28,"text":440,"correct":22},"三相短路",{"key":442,"text":443,"correct":22},"D","断线故障",{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":28,"analysis":30},712307,"直埋电缆中间接头要与相邻其他电缆线路接头之间错开至少()。",[448,450,452],{"key":20,"text":449,"correct":22},"0.2m",{"key":24,"text":451,"correct":22},"0.8m",{"key":28,"text":453,"correct":26},"0.5m",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":20,"analysis":30},712308,"铝芯、不滴流纸绝缘、铅包、钢带铠装、聚氯乙烯外护套电力电缆型号为()。",[458,459,460,462],{"key":20,"text":66,"correct":26},{"key":24,"text":70,"correct":22},{"key":28,"text":461,"correct":22},"22",{"key":442,"text":463,"correct":22},"ZLQ",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":28,"analysis":30},712309,"电缆采用聚乙烯护套的缺点是()。",[468,470,472],{"key":20,"text":469,"correct":22},"耐热性差",{"key":24,"text":471,"correct":22},"耐寒性差",{"key":28,"text":473,"correct":26},"阻燃性差",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":24,"analysis":30},712310,"在中性点不接地系统中,油浸纸绝缘统包型电力电缆的统包层厚度()。",[478,480,482],{"key":20,"text":479,"correct":22},"较薄",{"key":24,"text":481,"correct":26},"较厚",{"key":28,"text":483,"correct":22},"不变",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":24,"analysis":30},712311,"能承受一般机械外力、相当拉力,能应用于水底和竖井环境的电缆是()。",[488,490,492],{"key":20,"text":489,"correct":22},"ZQD23",{"key":24,"text":491,"correct":26},"ZQD33",{"key":28,"text":493,"correct":22},"ZQD03",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":28,"analysis":30},712312,"500kV模塑式终端接头的优点是()。",[498,500,502],{"key":20,"text":499,"correct":22},"生产工期短",{"key":24,"text":501,"correct":22},"操作工艺简单",{"key":28,"text":503,"correct":26},"加强绝缘与本体绝缘形成一体",{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":28,"analysis":30},712313,"电力电缆沟道敷设时,电力电缆与控制电缆()。",[508,510,512],{"key":20,"text":509,"correct":22},"不能安装在沟道同侧的支架上",{"key":24,"text":511,"correct":22},"应安装在沟道同侧的支架上",{"key":28,"text":513,"correct":26},"应分别安装在沟道两边的支架上",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":24,"analysis":30},712314,"运行电缆周围土壤温度应按指定地点定期测量,()期间应加大测量频度。",[518,520,522],{"key":20,"text":519,"correct":22},"春季高峰负荷",{"key":24,"text":521,"correct":26},"冬季高峰负荷",{"key":28,"text":523,"correct":22},"秋季高峰负荷",[525,528,531,533,536,539],{"id":526,"name":527,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":529,"name":530,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":532,"name":530,"category":7,"favorite":8},336,{"id":534,"name":535,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":537,"name":538,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":540,"name":541,"category":7,"favorite":8},353,"(N1)叉车司机"]