[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-382-13":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":512},{"id":5,"name":6,"category":7,"favorite":8},382,"电力电缆","特种作业",0,13,50,1595,[13,31,41,51,60,70,80,90,100,110,120,130,140,150,160,170,180,190,200,210,220,230,240,250,260,270,279,289,299,309,319,329,339,349,358,368,378,387,397,407,414,424,434,444,454,464,472,482,492,502],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":30},712215,1,"单选题","对于35kV及以下系统,电缆线路发生故障时,()。",[19,23,27],{"key":20,"text":21,"correct":22},"A","允许短时间过负荷",true,{"key":24,"text":25,"correct":26},"B","允许长时间过负荷",false,{"key":28,"text":29,"correct":26},"C","不允许过负荷","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":24,"analysis":30},712216,"电缆线芯外面有(),使其安全运行并避免人身触电。",[35,37,39],{"key":20,"text":36,"correct":26},"支柱绝缘子",{"key":24,"text":38,"correct":22},"绝缘层和保护层",{"key":28,"text":40,"correct":26},"绝缘套管",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":20,"analysis":30},712217,"制作电缆终端接头,不需要切断()。",[45,47,49],{"key":20,"text":46,"correct":22},"导体",{"key":24,"text":48,"correct":26},"绝缘层",{"key":28,"text":50,"correct":26},"内护套",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":20,"analysis":30},712218,"1kV单芯聚氯乙烯绝缘电力电缆的结构中不含()。",[55,57,58],{"key":20,"text":56,"correct":22},"钢带铠装",{"key":24,"text":46,"correct":26},{"key":28,"text":59,"correct":26},"聚氯乙烯绝缘",{"id":61,"libraryId":5,"type":15,"typeLabel":16,"stem":62,"options":63,"answer":24,"analysis":30},712219,"在相同电压等级下,电缆的线间距离()。",[64,66,68],{"key":20,"text":65,"correct":26},"比架空线路大",{"key":24,"text":67,"correct":22},"比架空线路小",{"key":28,"text":69,"correct":26},"等于架空线路",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":30},712220,"供直流输电的高压充油电缆最大工作场强可选取()。",[74,76,78],{"key":20,"text":75,"correct":22},"30-45kV\u002Fmm",{"key":24,"text":77,"correct":26},"50-80kV\u002Fmm",{"key":28,"text":79,"correct":26},"80-100kV\u002Fmm",{"id":81,"libraryId":5,"type":15,"typeLabel":16,"stem":82,"options":83,"answer":24,"analysis":30},712221,"在剥去一段铅套的电缆线芯上加一逐渐上升的电压时,相继发生的滑闪放电的现象为()。",[84,86,88],{"key":20,"text":85,"correct":26},"平行的红色刷形",{"key":24,"text":87,"correct":22},"白色树枝状滑动光线",{"key":28,"text":89,"correct":26},"紫色光环",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":28,"analysis":30},712222,"自容式充油电力电缆采用低黏度的电缆油,优点是()。",[94,96,98],{"key":20,"text":95,"correct":26},"加强导体的冷却",{"key":24,"text":97,"correct":26},"增加油流在油道中的压降",{"key":28,"text":99,"correct":22},"提高补充浸渍速度",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":20,"analysis":30},712223,"多芯电缆的绝缘线芯之间需要添加填芯和填料,以利于将其绞制成()。",[104,106,108],{"key":20,"text":105,"correct":22},"圆形",{"key":24,"text":107,"correct":26},"扇形",{"key":28,"text":109,"correct":26},"椭圆型",{"id":111,"libraryId":5,"type":15,"typeLabel":16,"stem":112,"options":113,"answer":28,"analysis":30},712224,"充油电缆加强层的材料通常是()。",[114,116,118],{"key":20,"text":115,"correct":26},"铝带或铅带",{"key":24,"text":117,"correct":26},"聚氯乙烯或聚乙烯",{"key":28,"text":119,"correct":22},"钢带或不锈钢带",{"id":121,"libraryId":5,"type":15,"typeLabel":16,"stem":122,"options":123,"answer":20,"analysis":30},712225,"由于集肤效应和邻近效应的存在,导体的载流量()。",[124,126,128],{"key":20,"text":125,"correct":22},"减小",{"key":24,"text":127,"correct":26},"不受影响",{"key":28,"text":129,"correct":26},"增大",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":30},712226,"测量电缆绝缘电阻时,1kV及以上电缆用()兆欧表。",[134,136,138],{"key":20,"text":135,"correct":26},"500V",{"key":24,"text":137,"correct":22},"2500V",{"key":28,"text":139,"correct":26},"1000V",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":20,"analysis":30},712227,"通常电缆的长度远大于线芯和绝缘层的半径,故不考虑()。",[144,146,148],{"key":20,"text":145,"correct":22},"边缘效应",{"key":24,"text":147,"correct":26},"发热效应",{"key":28,"text":149,"correct":26},"集肤效应",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":28,"analysis":30},712228,"插拔式终端的特点是()。",[154,156,158],{"key":20,"text":155,"correct":26},"使工程工期较长",{"key":24,"text":157,"correct":26},"整个电缆终端安装完成后穿入GIS仓",{"key":28,"text":159,"correct":22},"电缆终端安装与电气设备安装可独立进行",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":20,"analysis":30},712229,"高压和超高压充油电缆接头的铅封一般分2次进行,外层是起()作用的外铅。",[164,166,168],{"key":20,"text":165,"correct":22},"机械保护",{"key":24,"text":167,"correct":26},"绝缘",{"key":28,"text":169,"correct":26},"密封",{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":24,"analysis":30},712230,"铜芯、纸绝缘、分相铅包、钢带铠装、聚氯乙烯外护套电力电缆型号为()。",[174,176,178],{"key":20,"text":175,"correct":26},"ZLQF21",{"key":24,"text":177,"correct":22},"ZQF22",{"key":28,"text":179,"correct":26},"ZQ22",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":20,"analysis":30},712231,"10kV环网合环运行的危害包括()等。",[184,186,188],{"key":20,"text":185,"correct":22},"系统断路容量增加",{"key":24,"text":187,"correct":26},"使继电保护简单化",{"key":28,"text":189,"correct":26},"易于调度运行",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":20,"analysis":30},712232,"目前,交联聚乙烯电缆的使用寿命一般不少于()年。",[194,196,198],{"key":20,"text":195,"correct":22},"30",{"key":24,"text":197,"correct":26},"20",{"key":28,"text":199,"correct":26},"10",{"id":201,"libraryId":5,"type":15,"typeLabel":16,"stem":202,"options":203,"answer":24,"analysis":30},712233,"电缆线路对绝缘要求()。",[204,206,208],{"key":20,"text":205,"correct":26},"较低",{"key":24,"text":207,"correct":22},"较高",{"key":28,"text":209,"correct":26},"一般",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":20,"analysis":30},712234,"充油电缆加强层的作用是()。",[214,216,218],{"key":20,"text":215,"correct":22},"承受油压",{"key":24,"text":217,"correct":26},"防潮",{"key":28,"text":219,"correct":26},"防腐蚀",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":20,"analysis":30},712235,"钢丝铠装电缆适合采用()敷设方式。",[224,226,228],{"key":20,"text":225,"correct":22},"高落差竖井",{"key":24,"text":227,"correct":26},"排管",{"key":28,"text":229,"correct":26},"直埋地下",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":28,"analysis":30},712236,"吊起的电缆盘放置于地面时,应选择()的地面。",[234,236,238],{"key":20,"text":235,"correct":26},"疏松平整",{"key":24,"text":237,"correct":26},"有凹陷坑",{"key":28,"text":239,"correct":22},"坚实平整",{"id":241,"libraryId":5,"type":15,"typeLabel":16,"stem":242,"options":243,"answer":28,"analysis":30},712237,"电力电缆线路的进行施工挖掘时,专责人必须到现场()。",[244,246,248],{"key":20,"text":245,"correct":26},"进行操作",{"key":24,"text":247,"correct":26},"进行指挥",{"key":28,"text":249,"correct":22},"进行监护",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":24,"analysis":30},712238,"充沙电缆沟内电缆平行敷设沟中时,电缆层间净距应不小于()。",[254,256,258],{"key":20,"text":255,"correct":26},"20mm",{"key":24,"text":257,"correct":22},"100mm",{"key":28,"text":259,"correct":26},"35mm",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":28,"analysis":30},712239,"聚乙烯电缆只适用于()电缆线路。",[264,266,268],{"key":20,"text":265,"correct":26},"220kV及以上",{"key":24,"text":267,"correct":26},"35-110kV",{"key":28,"text":269,"correct":22},"10kV及以下",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":24,"analysis":30},712240,"电缆线路交叉互联箱和接地箱本体及其进线孔不得选用()材料。",[274,276,278],{"key":20,"text":275,"correct":26},"半导体",{"key":24,"text":277,"correct":22},"铁磁",{"key":28,"text":167,"correct":26},{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":28,"analysis":30},712241,"不能承受一般机械外力的电缆是()。",[283,285,287],{"key":20,"text":284,"correct":26},"ZLQ",{"key":24,"text":286,"correct":26},"ZQ",{"key":28,"text":288,"correct":22},"ZQD03",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":28,"analysis":30},712242,"电缆根据导体截面、绝缘材料、()不同,采用不同绝缘厚度。",[293,295,297],{"key":20,"text":294,"correct":26},"散热要求",{"key":24,"text":296,"correct":26},"线芯数目",{"key":28,"text":298,"correct":22},"系统接地方式",{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":20,"analysis":30},712243,"电缆线路交叉互联线和接地线应尽可能短,宜在()内。",[303,305,307],{"key":20,"text":304,"correct":22},"5m",{"key":24,"text":306,"correct":26},"8m",{"key":28,"text":308,"correct":26},"10m",{"id":310,"libraryId":5,"type":15,"typeLabel":16,"stem":311,"options":312,"answer":28,"analysis":30},712244,"110kV及以上交联聚乙烯电缆中间接头按照功能分为()。",[313,315,317],{"key":20,"text":314,"correct":26},"绝缘和半绝缘接头",{"key":24,"text":316,"correct":26},"半绝缘和直通接头",{"key":28,"text":318,"correct":22},"绝缘接头和直通接头",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":24,"analysis":30},712245,"对于10kV直埋电缆穿过农田时,自地面到电缆上面外皮的距离为()。",[323,325,327],{"key":20,"text":324,"correct":26},"0.7m",{"key":24,"text":326,"correct":22},"1.0m",{"key":28,"text":328,"correct":26},"1.2m",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":20,"analysis":30},712246,"电力电缆竖井敷设时,垂直固定宜()。",[333,335,337],{"key":20,"text":334,"correct":22},"每1m固定1次",{"key":24,"text":336,"correct":26},"每0.5m固定1次",{"key":28,"text":338,"correct":26},"每1.5m固定1次",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":24,"analysis":30},712247,"在极端潮湿环境、沿海盐雾环境,应选用()电缆终端。",[343,345,347],{"key":20,"text":344,"correct":26},"热收缩式",{"key":24,"text":346,"correct":22},"预制式",{"key":28,"text":348,"correct":26},"冷收缩式",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":20,"analysis":30},712248,"6~35kV三芯交联聚乙烯电缆共用()。",[353,354,356],{"key":20,"text":50,"correct":22},{"key":24,"text":355,"correct":26},"中性导体",{"key":28,"text":357,"correct":26},"地线",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":20,"analysis":30},712249,"电缆线路的缺点之一是()。",[362,364,366],{"key":20,"text":363,"correct":22},"不易分支",{"key":24,"text":365,"correct":26},"供电不可靠",{"key":28,"text":367,"correct":26},"维护工作复杂",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":24,"analysis":30},712250,"铜护套时适用于()电缆。",[372,374,376],{"key":20,"text":373,"correct":26},"短路容量要求小的小截面",{"key":24,"text":375,"correct":22},"短路容量要求大的大截面",{"key":28,"text":377,"correct":26},"短路容量要求大的小截面",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":28,"analysis":30},712251,"与交流电缆相比,直流电缆不存在()的影响。",[382,384,386],{"key":20,"text":383,"correct":26},"绝缘电阻",{"key":24,"text":385,"correct":26},"累积效应",{"key":28,"text":149,"correct":22},{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":20,"analysis":30},712252,"在北方地区敷设高压电缆时,冬天平均温度()以下,需要预先加热后再施工。",[391,393,395],{"key":20,"text":392,"correct":22},"0℃",{"key":24,"text":394,"correct":26},"-10℃",{"key":28,"text":396,"correct":26},"10℃",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":28,"analysis":30},712253,"110kV及以上XLPE电缆通常采用单端接地或交叉互联两端接地,其接地线的电流()。",[401,403,405],{"key":20,"text":402,"correct":26},"很大",{"key":24,"text":404,"correct":26},"较大",{"key":28,"text":406,"correct":22},"很小",{"id":408,"libraryId":5,"type":15,"typeLabel":16,"stem":409,"options":410,"answer":28,"analysis":30},712254,"电力电缆隧道敷设时,一般敷设()根及以上。",[411,412,413],{"key":20,"text":199,"correct":26},{"key":24,"text":197,"correct":26},{"key":28,"text":195,"correct":22},{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":20,"analysis":30},712255,"交联聚乙烯绝缘电缆的电树枝现象的特点是()。",[418,420,422],{"key":20,"text":419,"correct":22},"树枝连续清晰",{"key":24,"text":421,"correct":26},"树枝少且较粗",{"key":28,"text":423,"correct":26},"树枝密集且不连续",{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":24,"analysis":30},712256,"热收缩部件、热熔胶等的允许贮存期限:环境温度为()时不少于24个月。",[428,430,432],{"key":20,"text":429,"correct":26},"不高于25摄氏度",{"key":24,"text":431,"correct":22},"不高于35摄氏度",{"key":28,"text":433,"correct":26},"不高于45摄氏度",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":24,"analysis":30},712257,"自容式充油电力电缆任一点任意时刻的油压应大于()。",[438,440,442],{"key":20,"text":439,"correct":26},"0.01MPa",{"key":24,"text":441,"correct":22},"0.02MPa",{"key":28,"text":443,"correct":26},"0.03MPa",{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":20,"analysis":30},712258,"过零点电压比较法比较适用于现场及在线检测介质损耗,因为其()。",[448,450,452],{"key":20,"text":449,"correct":22},"抗干扰能力强",{"key":24,"text":451,"correct":26},"检测过程简单",{"key":28,"text":453,"correct":26},"算法更加准确",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":28,"analysis":30},712259,"分部工程“电缆中间接头”中包含分项工程()。",[458,460,462],{"key":20,"text":459,"correct":26},"户外终端",{"key":24,"text":461,"correct":26},"沟槽开挖",{"key":28,"text":463,"correct":22},"绝缘接头",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":24,"analysis":30},712260,"塑料电缆连接处加装玻璃钢保护盒并灌满沥青防水胶,其作用不包括()。",[468,469,470],{"key":20,"text":165,"correct":26},{"key":24,"text":167,"correct":22},{"key":28,"text":471,"correct":26},"防止水分浸入内部",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":28,"analysis":30},712261,"油浸纸绝缘统包型电力电缆的绝缘线芯之间填()为主的材料。",[476,478,480],{"key":20,"text":477,"correct":26},"纤维或麻",{"key":24,"text":479,"correct":26},"铁屑",{"key":28,"text":481,"correct":22},"纸、麻或其他材料",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":20,"analysis":30},712262,"通过对电缆的负荷和绝缘状况进行连续的在线监测,随时获得能反应绝缘状况变化的信息,从而有的放矢地进行维护的方式称为()。",[486,488,490],{"key":20,"text":487,"correct":22},"状态检修",{"key":24,"text":489,"correct":26},"矫正性检修",{"key":28,"text":491,"correct":26},"计划检修",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":28,"analysis":30},712263,"在不使用汽车吊和电缆拖车的情况下,为了能使电缆盘从地面升起,在盘轴上平稳转动进行电缆敷设,采用带千斤顶的()。",[496,498,500],{"key":20,"text":497,"correct":26},"牵引机",{"key":24,"text":499,"correct":26},"电缆运输机",{"key":28,"text":501,"correct":22},"电缆盘放缆支架",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":20,"analysis":30},712264,"单位面积电缆线芯输送电流能力与线芯截面的关系是()。",[506,508,510],{"key":20,"text":507,"correct":22},"随线芯截面积增大而降低",{"key":24,"text":509,"correct":26},"不随线芯截面积变化",{"key":28,"text":511,"correct":26},"随线芯截面积增大而增大",[513,516,519,521,524,527],{"id":514,"name":515,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":517,"name":518,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":520,"name":518,"category":7,"favorite":8},336,{"id":522,"name":523,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":525,"name":526,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":528,"name":529,"category":7,"favorite":8},353,"(N1)叉车司机"]