[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-382-11":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":514},{"id":5,"name":6,"category":7,"favorite":8},382,"电力电缆","特种作业",0,11,50,1595,[13,31,41,51,61,71,81,91,101,111,121,131,141,151,161,171,181,191,201,211,221,231,241,251,261,271,281,291,301,309,319,329,336,346,356,366,375,385,395,405,415,425,435,445,455,465,474,482,492,505],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":30},712115,1,"单选题","电缆型号YJV22-8.7\u002F10-3×240-600-GB12706.3中,600表示()。",[19,23,27],{"key":20,"text":21,"correct":22},"A","标称截面",false,{"key":24,"text":25,"correct":26},"B","长度",true,{"key":28,"text":29,"correct":22},"C","额定电压","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":28,"analysis":30},712116,"单芯自容式充油电力电缆适合用于()电压等级。",[35,37,39],{"key":20,"text":36,"correct":22},"10kV及以下",{"key":24,"text":38,"correct":22},"20-35kV",{"key":28,"text":40,"correct":26},"110kV-330kV",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":20,"analysis":30},712117,"电力电缆竖井敷设时,应优先选用()。",[45,47,49],{"key":20,"text":46,"correct":26},"交联聚乙烯",{"key":24,"text":48,"correct":22},"充油电缆",{"key":28,"text":50,"correct":22},"油浸支纸绝缘电缆",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":24,"analysis":30},712118,"电力电缆线路的检修主要经历了()种模式。",[55,57,59],{"key":20,"text":56,"correct":22},"1",{"key":24,"text":58,"correct":26},"3",{"key":28,"text":60,"correct":22},"2",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":20,"analysis":30},712119,"电力系统的电源结构与()有关。",[65,67,69],{"key":20,"text":66,"correct":26},"能源分布",{"key":24,"text":68,"correct":22},"工业布局",{"key":28,"text":70,"correct":22},"城市规划",{"id":72,"libraryId":5,"type":15,"typeLabel":16,"stem":73,"options":74,"answer":24,"analysis":30},712120,"ZQ30和ZLQ30型电缆适合敷设于()环境。",[75,77,79],{"key":20,"text":76,"correct":22},"室内",{"key":24,"text":78,"correct":26},"竖井及矿井中",{"key":28,"text":80,"correct":22},"水下",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":20,"analysis":30},712121,"热收缩部件的收缩温度是()。",[85,87,89],{"key":20,"text":86,"correct":26},"120-140℃",{"key":24,"text":88,"correct":22},"100-120℃",{"key":28,"text":90,"correct":22},"140-160℃",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":24,"analysis":30},712122,"交联聚乙烯绝缘电缆的电树枝比水树枝导致电缆击穿速度()。",[95,97,99],{"key":20,"text":96,"correct":22},"一样",{"key":24,"text":98,"correct":26},"快",{"key":28,"text":100,"correct":22},"慢",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":24,"analysis":30},712123,"随着交联聚乙烯电缆的大量使用,电缆在()中的故障逐渐减少。",[105,107,109],{"key":20,"text":106,"correct":22},"生产制造",{"key":24,"text":108,"correct":26},"运行",{"key":28,"text":110,"correct":22},"预防性试验",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":24,"analysis":30},712124,"简单规则圆形绞合电缆线芯的绞合规则是()。",[115,117,119],{"key":20,"text":116,"correct":22},"k=1+2+3+？？？+n",{"key":24,"text":118,"correct":26},"k=1+6+12+？？？+6n",{"key":28,"text":120,"correct":22},"k=21+22+23+？？？+2n",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":28,"analysis":30},712125,"移动运行中的10kV电缆应先经运行单位同意,且平移距离不得超过()。",[125,127,129],{"key":20,"text":126,"correct":22},"0.5m",{"key":24,"text":128,"correct":22},"1m",{"key":28,"text":130,"correct":26},"2m",{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":20,"analysis":30},712126,"对电缆定期进行主绝缘和交叉互联系统的预防性试验以及测温测负荷检查,并将结果与规程中的标准值比较,若超标则安排维修计划对设备停电检修,此维护方式称为()。",[135,137,139],{"key":20,"text":136,"correct":26},"计划检修",{"key":24,"text":138,"correct":22},"矫正性检修",{"key":28,"text":140,"correct":22},"状态检修",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":20,"analysis":30},712127,"增大电缆间距主要是为了减小()。",[145,147,149],{"key":20,"text":146,"correct":26},"邻近效应",{"key":24,"text":148,"correct":22},"集肤效应",{"key":28,"text":150,"correct":22},"边缘效应",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":24,"analysis":30},712128,"10kV及以下电压等级油浸纸绝缘电缆线芯截面一般采用()。",[155,157,159],{"key":20,"text":156,"correct":22},"圆形",{"key":24,"text":158,"correct":26},"扇形",{"key":28,"text":160,"correct":22},"椭圆形",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":28,"analysis":30},712129,"任何导体在电压作用下都必然产生()。",[165,167,169],{"key":20,"text":166,"correct":22},"磁场",{"key":24,"text":168,"correct":22},"电流",{"key":28,"text":170,"correct":26},"电场",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":24,"analysis":30},712130,"为减小电缆金属护套边缘的电场强度,可减小()。",[175,177,179],{"key":20,"text":176,"correct":22},"半径",{"key":24,"text":178,"correct":26},"绝缘层材料相对介电常数",{"key":28,"text":180,"correct":22},"周围媒质相对介电常数",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":28,"analysis":30},712131,"电缆接地电流过大,属于电缆()。",[185,187,189],{"key":20,"text":186,"correct":22},"接头和终端缺陷",{"key":24,"text":188,"correct":22},"敷设路径上的缺陷",{"key":28,"text":190,"correct":26},"线路附属设备缺陷",{"id":192,"libraryId":5,"type":15,"typeLabel":16,"stem":193,"options":194,"answer":20,"analysis":30},712132,"电缆绝缘层的利用系数是指绝缘层中()之比。",[195,197,199],{"key":20,"text":196,"correct":26},"平均电场强度与最大电场强度",{"key":24,"text":198,"correct":22},"平均电场强度与最小电场强度",{"key":28,"text":200,"correct":22},"最小电场强度与最大电场强度",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":20,"analysis":30},712133,"修复后的电缆外护套应做()试验。",[205,207,209],{"key":20,"text":206,"correct":26},"直流耐压或接地电阻",{"key":24,"text":208,"correct":22},"介质损耗",{"key":28,"text":210,"correct":22},"泄漏电流和介质损耗",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":24,"analysis":30},712134,"以下项中不容易产生电晕的是()。",[215,217,219],{"key":20,"text":216,"correct":22},"电缆终端瓷套管表面",{"key":24,"text":218,"correct":26},"增绕绝缘的中间接头",{"key":28,"text":220,"correct":22},"油浸纸绝缘电缆铅包端口",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":24,"analysis":30},712135,"自容式充油电力电缆敷设有较大落差时,()。",[225,227,229],{"key":20,"text":226,"correct":22},"应有径向铜带",{"key":24,"text":228,"correct":26},"应有纵向铜带或钢丝铠装",{"key":28,"text":230,"correct":22},"不用附加措施",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":24,"analysis":30},712136,"110kV及以上交联聚乙烯电缆中间接头用得较多的是()预制型2种。",[235,237,239],{"key":20,"text":236,"correct":22},"组装式和半组装式",{"key":24,"text":238,"correct":26},"组装式和整体式",{"key":28,"text":240,"correct":22},"半组装式和整体式",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":28,"analysis":30},712137,"电缆绝缘层厚度与利用系数的关系是()。",[245,247,249],{"key":20,"text":246,"correct":22},"无关",{"key":24,"text":248,"correct":22},"绝缘层越厚,利用系数越大",{"key":28,"text":250,"correct":26},"绝缘层越厚,利用系数越小",{"id":252,"libraryId":5,"type":15,"typeLabel":16,"stem":253,"options":254,"answer":20,"analysis":30},712138,"通常,油浸纸绝缘电缆的寿命为()年以上。",[255,257,259],{"key":20,"text":256,"correct":26},"40",{"key":24,"text":258,"correct":22},"30",{"key":28,"text":260,"correct":22},"50",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":20,"analysis":30},712139,"电缆盘距地面()时,应暂停,检视一切正常再行作业。",[265,267,269],{"key":20,"text":266,"correct":26},"20-50cm",{"key":24,"text":268,"correct":22},"30-80cm",{"key":28,"text":270,"correct":22},"50-80cm",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":20,"analysis":30},712140,"电力电缆接近热力管道敷设,会导致()。",[275,277,279],{"key":20,"text":276,"correct":26},"电缆过热",{"key":24,"text":278,"correct":22},"绝缘受潮",{"key":28,"text":280,"correct":22},"过电压",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":24,"analysis":30},712141,"性质一般,情况较轻,对安全运行影响不大,可列入检修计划处理的缺陷为()。",[285,287,289],{"key":20,"text":286,"correct":22},"危急缺陷",{"key":24,"text":288,"correct":26},"一般缺陷",{"key":28,"text":290,"correct":22},"严重缺陷",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":28,"analysis":30},712142,"以地理图为背景,标明一个地区内全部电缆线路的平面布置的图,称为()。",[295,297,299],{"key":20,"text":296,"correct":22},"电缆网络信息图",{"key":24,"text":298,"correct":22},"电缆网络系统接线图",{"key":28,"text":300,"correct":26},"电缆网络分布总图",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":24,"analysis":30},712143,"缆线路的缺陷分()类。",[305,306,307],{"key":20,"text":60,"correct":22},{"key":24,"text":58,"correct":26},{"key":28,"text":308,"correct":22},"4",{"id":310,"libraryId":5,"type":15,"typeLabel":16,"stem":311,"options":312,"answer":20,"analysis":30},712144,"电力电缆隧道敷设时,最上层至沟顶或楼板间的规定距离为()。",[313,315,317],{"key":20,"text":314,"correct":26},"300-350mm",{"key":24,"text":316,"correct":22},"150-200mm",{"key":28,"text":318,"correct":22},"350-450mm",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":28,"analysis":30},712145,"110kV交联聚乙烯电缆的内半导电屏蔽、交联聚乙烯绝缘和外半导电屏蔽必须()挤出。",[323,325,327],{"key":20,"text":324,"correct":22},"先后",{"key":24,"text":326,"correct":22},"任意顺序",{"key":28,"text":328,"correct":26},"同时",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":20,"analysis":30},712146,"表明电缆线路在电力系统中的供电情况以及电缆线路在电力系统供电中的重要性、负荷分布情况和运行状态,能直观反映电缆线路停电范围的图纸,称为()。",[333,334,335],{"key":20,"text":298,"correct":26},{"key":24,"text":300,"correct":22},{"key":28,"text":296,"correct":22},{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":28,"analysis":30},712147,"任何电缆事故的发生,都经历温度的()过程,因此应进行电缆温度监测。",[340,342,344],{"key":20,"text":341,"correct":22},"急剧上升",{"key":24,"text":343,"correct":22},"缓慢降低",{"key":28,"text":345,"correct":26},"缓慢上升——急剧上升——绝缘击穿",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":24,"analysis":30},712148,"高压和超高压充油电缆接头的铅封一般分2次进行,内层是起()作用的底铅。",[350,352,354],{"key":20,"text":351,"correct":22},"机械保护",{"key":24,"text":353,"correct":26},"密封",{"key":28,"text":355,"correct":22},"绝缘",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":24,"analysis":30},712149,"气体的击穿电场强度比浸渍纸低时,在高电压作用下,电缆的气隙()。",[360,362,364],{"key":20,"text":361,"correct":22},"不可能击穿",{"key":24,"text":363,"correct":26},"先击穿",{"key":28,"text":365,"correct":22},"后击穿",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":24,"analysis":30},712150,"电力电缆金属护套在生产过程中留下裂纹,会导致电缆()。",[370,372,373],{"key":20,"text":371,"correct":22},"绝缘老化",{"key":24,"text":278,"correct":26},{"key":28,"text":374,"correct":22},"金属护套受腐蚀",{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":20,"analysis":30},712151,"交联聚乙烯电缆()内部含有杂质、水分、微孔时,易发生树枝老化现象。",[379,381,383],{"key":20,"text":380,"correct":26},"绝缘层",{"key":24,"text":382,"correct":22},"外护层",{"key":28,"text":384,"correct":22},"屏蔽层",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":24,"analysis":30},712152,"110kV交联聚乙烯电缆金属护套的短路容量不满足要求时,可增加()屏蔽层。",[389,391,393],{"key":20,"text":390,"correct":22},"钢丝",{"key":24,"text":392,"correct":26},"铜丝",{"key":28,"text":394,"correct":22},"铝丝",{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":397,"options":398,"answer":28,"analysis":30},712153,"在电缆过河时,()而使电缆通过。",[399,401,403],{"key":20,"text":400,"correct":22},"可以搭设专用电缆桥",{"key":24,"text":402,"correct":22},"借助杆塔悬挂",{"key":28,"text":404,"correct":26},"可借助已有铁路桥上安装支架",{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":20,"analysis":30},712154,"对于35kV直埋电缆,自地面到电缆上面外皮的距离为()。",[409,411,413],{"key":20,"text":410,"correct":26},"1.0m",{"key":24,"text":412,"correct":22},"0.7m",{"key":28,"text":414,"correct":22},"1.2m",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":28,"analysis":30},712155,"一般地,近似认为单芯电缆的电场的电力线分布是()的。",[419,421,423],{"key":20,"text":420,"correct":22},"任意分布",{"key":24,"text":422,"correct":22},"沿轴向",{"key":28,"text":424,"correct":26},"沿径向",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":24,"analysis":30},712156,"油浸纸绝缘的导体屏蔽材料一般可以用()。",[429,431,433],{"key":20,"text":430,"correct":22},"半导电塑料",{"key":24,"text":432,"correct":26},"半导电纸带",{"key":28,"text":434,"correct":22},"半导电橡胶",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":24,"analysis":30},712157,"对于牵引力要求较大的电缆敷设地点,可采用输送机()牵引的方式。",[439,441,443],{"key":20,"text":440,"correct":22},"单点",{"key":24,"text":442,"correct":26},"多点",{"key":28,"text":444,"correct":22},"两点",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":28,"analysis":30},712158,"110kV交联聚乙烯电缆的金属护套的()不满足要求时,可增加铜丝屏蔽层。",[449,451,453],{"key":20,"text":450,"correct":22},"机械强度",{"key":24,"text":452,"correct":22},"电磁屏蔽",{"key":28,"text":454,"correct":26},"短路容量",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":20,"analysis":30},712159,"交联聚乙烯绝缘电缆的水树枝现象的特点是()。",[459,461,463],{"key":20,"text":460,"correct":26},"树枝密集且大多不连续",{"key":24,"text":462,"correct":22},"树枝连续清晰",{"key":28,"text":464,"correct":22},"树枝少且较粗",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":24,"analysis":30},712160,"电场强度的大小与()有关。",[469,470,472],{"key":20,"text":168,"correct":22},{"key":24,"text":471,"correct":26},"电压",{"key":28,"text":473,"correct":22},"功率",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":24,"analysis":30},712161,"充油电缆的线芯采用()。",[478,479,481],{"key":20,"text":156,"correct":22},{"key":24,"text":480,"correct":26},"中空圆形",{"key":28,"text":160,"correct":22},{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":24,"analysis":30},712162,"由于停电引起国民经济的损失平均值约为电力系统少售电能损失的()倍。",[486,488,490],{"key":20,"text":487,"correct":22},"40-50",{"key":24,"text":489,"correct":26},"30-40",{"key":28,"text":491,"correct":22},"50-60",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":503,"analysis":30},712163,"1kV五芯(3+2)聚氯乙烯绝缘电力电缆,3指3根相线,2指()。",[496,498,500,502],{"key":20,"text":497,"correct":22},"2根相线",{"key":24,"text":499,"correct":22},"2根N线",{"key":28,"text":501,"correct":22},"线(地线)",{"key":503,"text":504,"correct":26},"D","1根N线和1根P",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":28,"analysis":30},712164,"与其他型式电缆相比,橡胶绝缘电力电缆导体的绞合根数()。",[509,511,512],{"key":20,"text":510,"correct":22},"稍少",{"key":24,"text":96,"correct":22},{"key":28,"text":513,"correct":26},"稍多",[515,518,521,523,526,529],{"id":516,"name":517,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":519,"name":520,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":522,"name":520,"category":7,"favorite":8},336,{"id":524,"name":525,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":527,"name":528,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":530,"name":531,"category":7,"favorite":8},353,"(N1)叉车司机"]