[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-378-6":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":613},{"id":5,"name":6,"category":7,"favorite":8},378,"电工（技师）","技能鉴定",0,6,50,607,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,225,237,249,261,273,285,297,308,320,332,344,356,368,380,392,404,416,428,440,452,464,474,486,498,508,518,530,542,554,566,578,590,601],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},668661,1,"单选题","电力变压器并联运行是将满足条件的两台或多台电力变压器（）端子之间通过同一母线分别互相连接。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","一次侧同极性",false,{"key":24,"text":25,"correct":22},"B","二次侧同极性",{"key":27,"text":28,"correct":29},"C","一次侧和二次侧同极性",true,{"key":31,"text":32,"correct":22},"D","一次侧和二次侧异极性","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},668662,"髙压与高压同杆架设时，转角或分支横担距上横担应为（）mm。",[38,40,42,44],{"key":20,"text":39,"correct":22},"300",{"key":24,"text":41,"correct":29},"450",{"key":27,"text":43,"correct":22},"600",{"key":31,"text":45,"correct":22},"800",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},668663,"DB-25型绝缘油运行中取样试验，按标准规定凝点不高于（）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"-25℃",{"key":24,"text":53,"correct":22},"-10℃",{"key":27,"text":55,"correct":22},"-20℃",{"key":31,"text":57,"correct":29},"无规定",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},668664,"兆欧表的标尺是（）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"正向刻度的，并且是均匀的",{"key":24,"text":65,"correct":22},"反向刻度的，并且是均匀的",{"key":27,"text":67,"correct":22},"正向刻度的，并且是不均匀的",{"key":31,"text":69,"correct":29},"反向刻度的，并且是不均匀的",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},668665,"运行中的变压器发出\"噼啪\"声时，则是（）原因造成的。",[74,76,78,80],{"key":20,"text":75,"correct":22},"过负荷",{"key":24,"text":77,"correct":29},"内部绝缘击穿",{"key":27,"text":79,"correct":22},"有大容量动力设备起动",{"key":31,"text":81,"correct":22},"个别零件松动",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},668666,"变压器降压使用时，能输出较大的（）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"功率",{"key":24,"text":89,"correct":29},"电流",{"key":27,"text":91,"correct":22},"电能",{"key":31,"text":93,"correct":22},"电压",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},668667,"6KVFS型避雷器运行中工频放电电压范围应为（）KV。",[98,100,102,104],{"key":20,"text":99,"correct":22},"8~12",{"key":24,"text":101,"correct":29},"15〜21",{"key":27,"text":103,"correct":22},"16-19",{"key":31,"text":105,"correct":22},"23〜33",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},668668,"用电设备的输出功率与输入功率之比的百分数是设备的（）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"功率因数",{"key":24,"text":113,"correct":29},"效率",{"key":27,"text":115,"correct":22},"视在功率",{"key":31,"text":117,"correct":22},"有功功率",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":20,"analysis":33},668669,"SF6断路器调整时，相间中心距离误差不大于（）。",[122,124,126,128],{"key":20,"text":123,"correct":29},"5mm",{"key":24,"text":125,"correct":22},"10mm",{"key":27,"text":127,"correct":22},"12mm",{"key":31,"text":129,"correct":22},"20mm",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":27,"analysis":33},668670,"若变压器的额定容量是Ps,功率因数是0.8,则其额定有功功率是（）。",[134,136,138,140],{"key":20,"text":135,"correct":22},"Ps",{"key":24,"text":137,"correct":22},"1.25Ps",{"key":27,"text":139,"correct":29},"0.8Ps",{"key":31,"text":141,"correct":22},"0.64Ps",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":27,"analysis":33},668671,"6KV架空裸钢芯铝导线在居民区架设时，最小允许截面为（）。",[146,148,150,152],{"key":20,"text":147,"correct":22},"10mm²",{"key":24,"text":149,"correct":22},"16mm²",{"key":27,"text":151,"correct":29},"25mm²",{"key":31,"text":153,"correct":22},"35mm²",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":31,"analysis":33},668672,"三相对称电路中相电流超前相应线电流（）。",[158,160,162,164],{"key":20,"text":159,"correct":22},"90°",{"key":24,"text":161,"correct":22},"180°",{"key":27,"text":163,"correct":22},"45°",{"key":31,"text":165,"correct":29},"30°",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":24,"analysis":33},668673,"采用那种（）放大电路具有倒相作用。",[170,172,174,176],{"key":20,"text":171,"correct":22},"共集电极",{"key":24,"text":173,"correct":29},"共发射极",{"key":27,"text":175,"correct":22},"共基极",{"key":31,"text":177,"correct":22},"共栅极",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":24,"analysis":33},668674,"电力电缆铝芯线的连接常釆用（）。",[182,184,186,188],{"key":20,"text":183,"correct":22},"插接法",{"key":24,"text":185,"correct":29},"钳压法",{"key":27,"text":187,"correct":22},"绑接法",{"key":31,"text":189,"correct":22},"焊接法",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":20,"analysis":33},668675,"电路的视在功率等于总电压与（）的乘积。",[194,196,198,200],{"key":20,"text":195,"correct":29},"总电流",{"key":24,"text":197,"correct":22},"总电阻",{"key":27,"text":199,"correct":22},"总阻抗",{"key":31,"text":201,"correct":22},"总功率",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":24,"analysis":33},668676,"三相铁芯式变压器是由铁辄把三相（）联在一起的三相变压器。",[206,208,210,212],{"key":20,"text":207,"correct":22},"绕组",{"key":24,"text":209,"correct":29},"铁芯",{"key":27,"text":211,"correct":22},"绕组和铁芯",{"key":31,"text":213,"correct":22},"上述说法都不对",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":20,"analysis":33},668677,"调节同步发电机的励磁机的励磁电流，则可以调节同步发电机的（）。",[218,220,221,223],{"key":20,"text":219,"correct":29},"端电压",{"key":24,"text":111,"correct":22},{"key":27,"text":222,"correct":22},"转速",{"key":31,"text":224,"correct":22},"频率",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":24,"analysis":33},668678,"中性点接地，设备外壳接中性线的运行方式叫（）。",[229,231,233,235],{"key":20,"text":230,"correct":22},"保护接地",{"key":24,"text":232,"correct":29},"保护接零",{"key":27,"text":234,"correct":22},"接地或接零",{"key":31,"text":236,"correct":22},"接地保护",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":31,"analysis":33},668679,"指针式万用表釆用的是（）测量机构。",[241,243,245,247],{"key":20,"text":242,"correct":22},"电磁系",{"key":24,"text":244,"correct":22},"感应系",{"key":27,"text":246,"correct":22},"静电系",{"key":31,"text":248,"correct":29},"磁电系",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":31,"analysis":33},668680,"（）可以签发电气设备工作票。",[253,255,257,259],{"key":20,"text":254,"correct":22},"工作负责人",{"key":24,"text":256,"correct":22},"工作许可人",{"key":27,"text":258,"correct":22},"工作人员",{"key":31,"text":260,"correct":29},"熟悉本工作规程的生产领导",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":31,"analysis":33},668681,"一般钳形电流表，不适用（）电流的测量。",[265,267,269,271],{"key":20,"text":266,"correct":22},"单相交流电路",{"key":24,"text":268,"correct":22},"三相交流电路",{"key":27,"text":270,"correct":22},"高压交流二次回路",{"key":31,"text":272,"correct":29},"直流电路",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":20,"analysis":33},668682,"交直流耐压试验设备适宜放置在下列（）场合。",[277,279,281,283],{"key":20,"text":278,"correct":29},"干燥",{"key":24,"text":280,"correct":22},"污染",{"key":27,"text":282,"correct":22},"腐蚀",{"key":31,"text":284,"correct":22},"强电磁场",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":24,"analysis":33},668683,"用万用表测试好的单向晶闸管时，A-G极间正反向电阻应该（）。",[289,291,293,295],{"key":20,"text":290,"correct":22},"都不大",{"key":24,"text":292,"correct":29},"都很大",{"key":27,"text":294,"correct":22},"都很小",{"key":31,"text":296,"correct":22},"一小一大",{"id":298,"libraryId":5,"type":15,"typeLabel":16,"stem":299,"options":300,"answer":20,"analysis":33},668684,"直流耐压试验时，当所用试验变压器只有一只引出线套管时，微安表串联接入（）。",[301,303,305,307],{"key":20,"text":302,"correct":29},"高压端",{"key":24,"text":304,"correct":22},"低压端",{"key":27,"text":306,"correct":22},"高压端或低压端",{"key":31,"text":57,"correct":22},{"id":309,"libraryId":5,"type":15,"typeLabel":16,"stem":310,"options":311,"answer":20,"analysis":33},668685,"DB-45型新绝缘油，用目测检査油样时，（）炭微粒和机械杂质。",[312,314,316,318],{"key":20,"text":313,"correct":29},"不应发现有",{"key":24,"text":315,"correct":22},"允许含有微量",{"key":27,"text":317,"correct":22},"允许含有一定量",{"key":31,"text":319,"correct":22},"允许含有少量",{"id":321,"libraryId":5,"type":15,"typeLabel":16,"stem":322,"options":323,"answer":24,"analysis":33},668686,"三相电源绕组星形联接时对外可输出（）电压。",[324,326,328,330],{"key":20,"text":325,"correct":22},"一种",{"key":24,"text":327,"correct":29},"二种",{"key":27,"text":329,"correct":22},"三种",{"key":31,"text":331,"correct":22},"四种",{"id":333,"libraryId":5,"type":15,"typeLabel":16,"stem":334,"options":335,"answer":31,"analysis":33},668687,"断路器每相导电回路电阻的阻值很小，应用（）方法测取。",[336,338,340,342],{"key":20,"text":337,"correct":22},"将断路器跳合几次",{"key":24,"text":339,"correct":22},"手动合闸时去掉千斤顶",{"key":27,"text":341,"correct":22},"多次复测",{"key":31,"text":343,"correct":29},"取三次分散性最小的值的平均值",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":27,"analysis":33},668688,"室外变压器的正常过负荷值不得超过其额定容量的（）。",[348,350,352,354],{"key":20,"text":349,"correct":22},"10%",{"key":24,"text":351,"correct":22},"20%",{"key":27,"text":353,"correct":29},"30%",{"key":31,"text":355,"correct":22},"40%",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":27,"analysis":33},668689,"在交流电路的功率三角形中，功率因数cosΦ=（）。",[360,362,364,366],{"key":20,"text":361,"correct":22},"无功功率\u002F视在功率",{"key":24,"text":363,"correct":22},"无功功率\u002F有功功率",{"key":27,"text":365,"correct":29},"有功功率\u002F视在功率",{"key":31,"text":367,"correct":22},"视在功率\u002F无功功率",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":31,"analysis":33},668690,"我国规定的电力系统中性点接地的方式有（）种。",[372,374,376,378],{"key":20,"text":373,"correct":22},"6",{"key":24,"text":375,"correct":22},"5",{"key":27,"text":377,"correct":22},"4",{"key":31,"text":379,"correct":29},"3",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":24,"analysis":33},668691,"三相异步电动机外壳带电，造成故障的可能原因是（）。",[384,386,388,390],{"key":20,"text":385,"correct":22},"电源电压过高",{"key":24,"text":387,"correct":29},"接地不良或接地电阻太大",{"key":27,"text":389,"correct":22},"负载过重",{"key":31,"text":391,"correct":22},"电机与负载轴线不对",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":24,"analysis":33},668692,"6\u002F0.4KV电力变压器低压侧中性点应进行工作接地，其接地电阻值应不大于（）。",[396,398,400,402],{"key":20,"text":397,"correct":22},"0.4Ω",{"key":24,"text":399,"correct":29},"4Ω",{"key":27,"text":401,"correct":22},"8Ω",{"key":31,"text":403,"correct":22},"10Ω",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":24,"analysis":33},668693,"发电机并网运行时发电机电压的相序与电网电压相序要（）。",[408,410,412,414],{"key":20,"text":409,"correct":22},"相反",{"key":24,"text":411,"correct":29},"相同",{"key":27,"text":413,"correct":22},"不能一致",{"key":31,"text":415,"correct":22},"无关",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":31,"analysis":33},668694,"耐压试验现场工作必须执行工作票制度，工作许可制度，工作监护制度，还有（）制度。",[420,422,424,426],{"key":20,"text":421,"correct":22},"工作间断",{"key":24,"text":423,"correct":22},"工作转移",{"key":27,"text":425,"correct":22},"工作终结",{"key":31,"text":427,"correct":29},"工作间断和转移及总结",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":27,"analysis":33},668695,"某电源开路电压为220伏，短路电流为2安，则负载从电源获得的最大功率为（）。",[432,434,436,438],{"key":20,"text":433,"correct":22},"120W",{"key":24,"text":435,"correct":22},"240W",{"key":27,"text":437,"correct":29},"60W",{"key":31,"text":439,"correct":22},"30W",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":24,"analysis":33},668696,"三相四线制供电线路中，若相电压为220伏，则火线与火线间电压为（）。",[444,446,448,450],{"key":20,"text":445,"correct":22},"220V",{"key":24,"text":447,"correct":29},"380V",{"key":27,"text":449,"correct":22},"311V",{"key":31,"text":451,"correct":22},"440V",{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":454,"options":455,"answer":20,"analysis":33},668697,"在以（ωt)为横轴的电流波形图中，取任一角度所对应的电流值叫该电流的（）。",[456,458,460,462],{"key":20,"text":457,"correct":29},"瞬时值",{"key":24,"text":459,"correct":22},"有效值",{"key":27,"text":461,"correct":22},"平均值",{"key":31,"text":463,"correct":22},"最大值",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":24,"analysis":33},668698,"单相桥式半控整流电路，有（）组触发电压。",[468,470,472,473],{"key":20,"text":469,"correct":22},"1",{"key":24,"text":471,"correct":29},"2",{"key":27,"text":379,"correct":22},{"key":31,"text":377,"correct":22},{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":24,"analysis":33},668699,"运行中的DB-45型绝缘油的闪点应不比新油标准降低（）。",[478,480,482,484],{"key":20,"text":479,"correct":22},"3℃",{"key":24,"text":481,"correct":29},"5℃",{"key":27,"text":483,"correct":22},"7℃",{"key":31,"text":485,"correct":22},"9℃",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":20,"analysis":33},668700,"测量仪表进行检验的目的是检查仪表各项技术特性，特别是（）是否符合规定。",[490,492,494,496],{"key":20,"text":491,"correct":29},"准确度",{"key":24,"text":493,"correct":22},"内阻",{"key":27,"text":495,"correct":22},"工作条件",{"key":31,"text":497,"correct":22},"绝缘强度",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":31,"analysis":33},668701,"三相半控桥式整流电路的最大移相范围是（）。",[502,503,505,507],{"key":20,"text":159,"correct":22},{"key":24,"text":504,"correct":22},"120°",{"key":27,"text":506,"correct":22},"150°",{"key":31,"text":161,"correct":29},{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":31,"analysis":33},668702,"已知变压器容量Ps,功率因数为0.8,则其无功功率是（）。",[512,514,515,516],{"key":20,"text":513,"correct":22},"1Ps",{"key":24,"text":139,"correct":22},{"key":27,"text":137,"correct":22},{"key":31,"text":517,"correct":29},"0.6Ps",{"id":519,"libraryId":5,"type":15,"typeLabel":16,"stem":520,"options":521,"answer":27,"analysis":33},668703,"功率表在电路中应釆用（）接法。",[522,524,526,528],{"key":20,"text":523,"correct":22},"电流线圈发电机端接电流流入端",{"key":24,"text":525,"correct":22},"电压线圈发电机端接电流流入端",{"key":27,"text":527,"correct":29},"电压、电流线圈的发电机端都接电流流入端",{"key":31,"text":529,"correct":22},"电压、电流线圈的发电机端都接电流流出端",{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":27,"analysis":33},668704,"目前使用最广泛的接地摇表如ZC-8型，属（）类型的仪表。",[534,536,538,540],{"key":20,"text":535,"correct":22},"流比计型",{"key":24,"text":537,"correct":22},"电桥型",{"key":27,"text":539,"correct":29},"电位计型",{"key":31,"text":541,"correct":22},"电压电流表型",{"id":543,"libraryId":5,"type":15,"typeLabel":16,"stem":544,"options":545,"answer":24,"analysis":33},668705,"调整高压开关的触头时，常用（）的塞尺检査触头接触面的压力。",[546,548,550,552],{"key":20,"text":547,"correct":22},"0.04mmX10mm",{"key":24,"text":549,"correct":29},"0.05mmX10mm",{"key":27,"text":551,"correct":22},"0.06mmX10mm",{"key":31,"text":553,"correct":22},"随意",{"id":555,"libraryId":5,"type":15,"typeLabel":16,"stem":556,"options":557,"answer":27,"analysis":33},668706,"变压器吊装所用绳索的安全系数为（）。",[558,560,562,564],{"key":20,"text":559,"correct":22},"大于2",{"key":24,"text":561,"correct":22},"大于3",{"key":27,"text":563,"correct":29},"大于5〜6",{"key":31,"text":565,"correct":22},"大于7〜8",{"id":567,"libraryId":5,"type":15,"typeLabel":16,"stem":568,"options":569,"answer":27,"analysis":33},668707,"电杆埋设深度最浅不应小于（）m。",[570,572,574,576],{"key":20,"text":571,"correct":22},"1.0",{"key":24,"text":573,"correct":22},"1.2",{"key":27,"text":575,"correct":29},"1.5",{"key":31,"text":577,"correct":22},"1.8",{"id":579,"libraryId":5,"type":15,"typeLabel":16,"stem":580,"options":581,"answer":24,"analysis":33},668708,"仪器仪表的维护存放，不应釆取（）措施。",[582,584,586,588],{"key":20,"text":583,"correct":22},"保持干燥",{"key":24,"text":585,"correct":29},"放在强磁场周围",{"key":27,"text":587,"correct":22},"轻拿轻放",{"key":31,"text":589,"correct":22},"棉纱擦拭",{"id":591,"libraryId":5,"type":15,"typeLabel":16,"stem":592,"options":593,"answer":20,"analysis":33},668709,"室内变压器在其事故过负荷2倍时，允许持续时间为（）分钟。",[594,595,597,599],{"key":20,"text":377,"correct":29},{"key":24,"text":596,"correct":22},"8",{"key":27,"text":598,"correct":22},"10",{"key":31,"text":600,"correct":22},"20",{"id":602,"libraryId":5,"type":15,"typeLabel":16,"stem":603,"options":604,"answer":20,"analysis":33},668710,"下列测量变压器变比的方法错误的是（）。",[605,607,609,611],{"key":20,"text":606,"correct":29},"双臂电桥法",{"key":24,"text":608,"correct":22},"变比电桥法",{"key":27,"text":610,"correct":22},"高压测量法",{"key":31,"text":612,"correct":22},"低压测量法",[614,617,620,623,626,629],{"id":615,"name":616,"category":7,"favorite":8},338,"保育员",{"id":618,"name":619,"category":7,"favorite":8},339,"保育员（初级）",{"id":621,"name":622,"category":7,"favorite":8},341,"保育员（中级）",{"id":624,"name":625,"category":7,"favorite":8},342,"保育员（高级）",{"id":627,"name":628,"category":7,"favorite":8},344,"茶艺师",{"id":630,"name":631,"category":7,"favorite":8},345,"茶艺师（初级）"]