[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-374-6":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":503},{"id":5,"name":6,"category":7,"favorite":8},374,"安规题库","特种作业",0,6,50,960,[13,31,41,51,61,71,81,91,101,111,121,131,141,148,155,164,174,184,194,204,212,222,230,240,250,259,269,279,289,299,309,319,329,339,349,358,366,376,385,395,405,415,425,435,445,455,464,474,484,493],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":30},710273,1,"单选题","依据《中国南方电网有限责任公司电力安全工作规程》，低压配电网工作需要间断时，应（ ），并在备注栏注明。",[19,23,27],{"key":20,"text":21,"correct":22},"A","重新办理工作票",true,{"key":24,"text":25,"correct":26},"B","办理间断手续",false,{"key":28,"text":29,"correct":26},"C","办理工作终结手续","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":20,"analysis":30},710274,"依据《中国南方电网有限责任公司电力安全工作规程》，厂站工作时，一张工作票上所列的多个检修设备，若至预定送电时一部分工作尚未完成，需继续工作而不妨碍其他送电者，应办理相应的（ ）和新的工作票，方可继续工作。",[35,37,39],{"key":20,"text":36,"correct":22},"工作终结",{"key":24,"text":38,"correct":26},"工作间断",{"key":28,"text":40,"correct":26},"停电申请",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":20,"analysis":30},710275,"依据《中国南方电网有限责任公司电力安全工作规程》，线路工作票及低压配电网工作票的工作人员变更时，工作负责人可不通知工作许可人，但需与（ ）办理变更手续。",[45,47,49],{"key":20,"text":46,"correct":22},"工作票签发人",{"key":24,"text":48,"correct":26},"值班负责人",{"key":28,"text":50,"correct":26},"现场负责人",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":20,"analysis":30},710276,"依据《中国南方电网有限责任公司电力安全工作规程》，在电气设备上工作时，保证安全的技术措施由（ ）或有相应资格的人员执行，并应有监护人在场。",[55,57,59],{"key":20,"text":56,"correct":22},"运行人员",{"key":24,"text":58,"correct":26},"检修人员",{"key":28,"text":60,"correct":26},"施工人员",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":20,"analysis":30},710277,"依据《中国南方电网有限责任公司电力安全工作规程》，在停电的电气设备上接地（装设接地线或合接地刀闸）前，应（ ），验明电气设备确无电压。高压验电时应戴绝缘手套并有专人监护。",[65,67,69],{"key":20,"text":66,"correct":22},"先验电",{"key":24,"text":68,"correct":26},"先装设导体端",{"key":28,"text":70,"correct":26},"先验高压",{"id":72,"libraryId":5,"type":15,"typeLabel":16,"stem":73,"options":74,"answer":20,"analysis":30},710278,"依据《中国南方电网有限责任公司电力安全工作规程》，作业人员应在（ ）的保护范围内作业。",[75,77,79],{"key":20,"text":76,"correct":22},"接地线",{"key":24,"text":78,"correct":26},"隔离栏",{"key":28,"text":80,"correct":26},"绝缘罩",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":20,"analysis":30},710279,"依据《中国南方电网有限责任公司电力安全工作规程》，装拆接地线导体端应使用（ ）或专用的绝缘绳，人体不应碰触接地线。",[85,87,89],{"key":20,"text":86,"correct":22},"绝缘棒",{"key":24,"text":88,"correct":26},"木棒",{"key":28,"text":90,"correct":26},"金属棒",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":20,"analysis":30},710280,"依据《中国南方电网有限责任公司电力安全工作规程》，在门型构架的线路侧停电检修，工作地点在厂站接地点外侧，应在（ ）装设接地线。",[95,97,99],{"key":20,"text":96,"correct":22},"线路侧",{"key":24,"text":98,"correct":26},"旁路母线侧",{"key":28,"text":100,"correct":26},"线路杆塔上",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":20,"analysis":30},710281,"依据《中国南方电网有限责任公司电力安全工作规程》，在室内配电装置上，接地线应装在该装置导电部分的规定地点，应刮去这些地点的油漆，并划有（ ）。",[105,107,109],{"key":20,"text":106,"correct":22},"黑色标记",{"key":24,"text":108,"correct":26},"红色标记",{"key":28,"text":110,"correct":26},"黄色标记",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":20,"analysis":30},710282,"依据《中国南方电网有限责任公司电力安全工作规程》，绝缘导线的接地线应装设在（ ）上或裸露的导电部分。",[115,117,119],{"key":20,"text":116,"correct":22},"验电接地环",{"key":24,"text":118,"correct":26},"分支接头",{"key":28,"text":120,"correct":26},"电缆端头",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":20,"analysis":30},710283,"依据《中国南方电网有限责任公司电力安全工作规程》，在同杆塔多回路部分线路停电作业装设接地线时，应采取防止接地线摆动的措施，并满足（ ）的规定。",[125,127,129],{"key":20,"text":126,"correct":22},"作业安全距离",{"key":24,"text":128,"correct":26},"带电作业",{"key":28,"text":130,"correct":26},"间隙距离",{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":20,"analysis":30},710284,"依据《中国南方电网有限责任公司电力安全工作规程》，（ ）应在杆塔上接触或接近导线的作业开始前装设，作业结束且人体脱离导线后拆除。",[135,137,139],{"key":20,"text":136,"correct":22},"个人保安线",{"key":24,"text":138,"correct":26},"工作接地线",{"key":28,"text":140,"correct":26},"架空地线",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":20,"analysis":30},710285,"依据《中国南方电网有限责任公司电力安全工作规程》，在工作地段有感应电伤害风险时，应在作业地点装设（ ）。",[145,146,147],{"key":20,"text":136,"correct":22},{"key":24,"text":138,"correct":26},{"key":28,"text":140,"correct":26},{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":20,"analysis":30},710286,"依据《中国南方电网有限责任公司电力安全工作规程》，在110kV及以上线路上工作使用（ ）时，可在工作相（极）装设单根个人保安线。",[152,153,154],{"key":20,"text":136,"correct":22},{"key":24,"text":138,"correct":26},{"key":28,"text":140,"correct":26},{"id":156,"libraryId":5,"type":15,"typeLabel":16,"stem":157,"options":158,"answer":20,"analysis":30},710287,"依据《中国南方电网有限责任公司电力安全工作规程》，不论高压设备带电与否，值班人员不应单独移开或越过遮栏进行工作；若有必要移开遮栏时，应有（ ）在场。",[159,161,162],{"key":20,"text":160,"correct":22},"监护人",{"key":24,"text":48,"correct":26},{"key":28,"text":163,"correct":26},"工作负责人",{"id":165,"libraryId":5,"type":15,"typeLabel":16,"stem":166,"options":167,"answer":20,"analysis":30},710288,"依据《中国南方电网有限责任公司电力安全工作规程》，大风时，巡线应沿线路( )进行。",[168,170,172],{"key":20,"text":169,"correct":22},"上风侧",{"key":24,"text":171,"correct":26},"下风侧",{"key":28,"text":173,"correct":26},"外侧",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":20,"analysis":30},710289,"依据《中国南方电网有限责任公司电力安全工作规程》，（ ）应始终认为线路、设备带电，即使明知该线路、设备已停电，亦应认为线路、设备随时有恢复送电的可能。",[178,180,182],{"key":20,"text":179,"correct":22},"事故巡视",{"key":24,"text":181,"correct":26},"事故抢修",{"key":28,"text":183,"correct":26},"停电检修",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":20,"analysis":30},710290,"依据《中国南方电网有限责任公司电力安全工作规程》，高压电气设备应具有防止误操作闭锁功能（装置），无防误闭锁功能（装置）或闭锁功能（装置）失灵的隔离开关或断路器应加挂（ ）。",[188,190,192],{"key":20,"text":189,"correct":22},"机械锁",{"key":24,"text":191,"correct":26},"五防锁",{"key":28,"text":193,"correct":26},"电子锁",{"id":195,"libraryId":5,"type":15,"typeLabel":16,"stem":196,"options":197,"answer":20,"analysis":30},710291,"依据《中国南方电网有限责任公司电力安全工作规程》， 新（改）建设备投产操作，调度端和现场端宜使用操作票，根据（ ）的步骤进行操作。对情况较复杂、不具备使用操作票的，需经同级调度机构或厂局分管运行负责人批准，可用代替操作票进行操作，但在启动方案操作步骤内容的空白处，应完整准确记录涉及的发令人、操作人和操作时间。",[198,200,202],{"key":20,"text":199,"correct":22},"启动方案",{"key":24,"text":201,"correct":26},"施工方案",{"key":28,"text":203,"correct":26},"设计图纸",{"id":205,"libraryId":5,"type":15,"typeLabel":16,"stem":206,"options":207,"answer":20,"analysis":30},710292,"依据《中国南方电网有限责任公司电力安全工作规程》，书面形式命令和记录以及不使用操作票的新（改）设备启动方案，在操作前，应经（ ）确认并同意。",[208,209,210],{"key":20,"text":48,"correct":22},{"key":24,"text":163,"correct":26},{"key":28,"text":211,"correct":26},"工作监护人",{"id":213,"libraryId":5,"type":15,"typeLabel":16,"stem":214,"options":215,"answer":20,"analysis":30},710293,"依据《中国南方电网有限责任公司电力安全工作规程》，操作临时变更时，应按实际情况重新填写（ ）方可继续进行倒闸操作。",[216,218,220],{"key":20,"text":217,"correct":22},"操作票",{"key":24,"text":219,"correct":26},"工作票",{"key":28,"text":221,"correct":26},"抢修单",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":20,"analysis":30},710294,"依据《中国南方电网有限责任公司电力安全工作规程》，按新（改）建设备投产方案进行操作时，若操作中出现问题，应由（ ）重新核准后，方可继续操作。",[226,228,229],{"key":20,"text":227,"correct":22},"方案审批人",{"key":24,"text":48,"correct":26},{"key":28,"text":211,"correct":26},{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":20,"analysis":30},710295,"依据《中国南方电网有限责任公司电力安全工作规程》，调度操作过程中，若现场操作人员汇报本操作可能（ ）时，应立即停止操作，待研究后再确定是否继续操作。",[234,236,238],{"key":20,"text":235,"correct":22},"危及人身安全",{"key":24,"text":237,"correct":26},"导致设备故障",{"key":28,"text":239,"correct":26},"造成五防混乱",{"id":241,"libraryId":5,"type":15,"typeLabel":16,"stem":242,"options":243,"answer":20,"analysis":30},710296,"依据《中国南方电网有限责任公司电力安全工作规程》，雨天操作室外高压设备时，应使用有（ ）的绝缘棒，并穿绝缘靴、戴绝缘手套。",[244,246,248],{"key":20,"text":245,"correct":22},"防雨罩",{"key":24,"text":247,"correct":26},"手柄",{"key":28,"text":249,"correct":26},"特殊标记",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":20,"analysis":30},710297,"依据《中国南方电网有限责任公司电力安全工作规程》，远方操作设备前，必要时应在现场增加（ ）或监护人，现场人员应确保自身安全。",[254,256,258],{"key":20,"text":255,"correct":22},"位置检查人",{"key":24,"text":257,"correct":26},"现场操作人",{"key":28,"text":163,"correct":26},{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":20,"analysis":30},710298,"依据《中国南方电网有限责任公司电力安全工作规程》，手动操作有机械传动的断路器或隔离开关时，应戴（ ）；手动操作没有机械传动的断路器或隔离开关时，应使用绝缘棒并戴绝缘手套和穿绝缘鞋。",[263,265,267],{"key":20,"text":264,"correct":22},"绝缘手套",{"key":24,"text":266,"correct":26},"护目镜",{"key":28,"text":268,"correct":26},"防电弧服",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":20,"analysis":30},710299,"依据《中国南方电网有限责任公司电力安全工作规程》，飞车安装间隔棒时，前后轮应（）。",[273,275,277],{"key":20,"text":274,"correct":22},"卡死(刹牢)",{"key":24,"text":276,"correct":26},"一侧卡死",{"key":28,"text":278,"correct":26},"下坡侧卡死",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":20,"analysis":30},710300,"依据《中国南方电网有限责任公司电力安全工作规程》，雷电天气时，禁止测量接地电阻、设备绝缘电阻及进行（）核相工作。沿线出现雷雨天气时不应进行线路测量工作。",[283,285,287],{"key":20,"text":284,"correct":22},"高压侧",{"key":24,"text":286,"correct":26},"中压侧",{"key":28,"text":288,"correct":26},"低压侧",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":20,"analysis":30},710301,"依据《中国南方电网有限责任公司电力安全工作规程》，在带电设备附近测量绝缘电阻时，测量人员和绝缘电阻表安放位置应保持（），以免绝缘电阻表引线或引线支持物触碰带电部分。",[293,295,297],{"key":20,"text":294,"correct":22},"安全距离",{"key":24,"text":296,"correct":26},"足够的距离",{"key":28,"text":298,"correct":26},"一定距离",{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":20,"analysis":30},710302,"依据《中国南方电网有限责任公司电力安全工作规程》，放线、紧线前，应检查导线（ ），导线与牵引绳的连接应可靠，线盘架应稳固可靠、转动灵活、制动可靠。",[303,305,307],{"key":20,"text":304,"correct":22},"有无障碍物挂住",{"key":24,"text":306,"correct":26},"已可靠接地",{"key":28,"text":308,"correct":26},"绝缘包裹",{"id":310,"libraryId":5,"type":15,"typeLabel":16,"stem":311,"options":312,"answer":20,"analysis":30},710303,"依据《中国南方电网有限责任公司电力安全工作规程》，杆塔分解组立时，塔片就位时应先低侧、后高侧。主材和侧面大斜材未全部连接牢固前，不准在吊件上作业。提升抱杆时应逐节提升，不应提升过高。单面吊装时，抱杆倾斜不宜超过（ ）；双面吊装时，抱杆两侧的荷重、提升速度及摇臂的变幅角度应基本一致。",[313,315,317],{"key":20,"text":314,"correct":22},"15度",{"key":24,"text":316,"correct":26},"25度",{"key":28,"text":318,"correct":26},"35度",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":20,"analysis":30},710304,"依据《中国南方电网有限责任公司电力安全工作规程》，工作票按设备调度、运行维护权限办理许可手续。涉及（ ）的许可工作，应按照“谁调度，谁许可；谁运行，谁许可”的原则。",[323,325,327],{"key":20,"text":324,"correct":22},"线路",{"key":24,"text":326,"correct":26},"变电",{"key":28,"text":328,"correct":26},"配电网",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":20,"analysis":30},710305,"依据《中国南方电网有限责任公司电力安全工作规程》，工作期间，工作负责人因故暂时离开工作现场时，应（ ）或指定有资质的人员临时代替，并交代清楚工作任务、现场安全措施、工作班人员情况及其他注意事项，并告知工作许可人和工作班人员。",[333,335,337],{"key":20,"text":334,"correct":22},"暂停工作",{"key":24,"text":336,"correct":26},"办理工作终结",{"key":28,"text":338,"correct":26},"办理工作间断",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":20,"analysis":30},710306,"依据《中国南方电网有限责任公司电力安全工作规程》，设备内的SF6气体不应向大气排放，应采取（ ），经处理检测合格后方可再使用。回收时工作人员应站在上风侧。",[343,345,347],{"key":20,"text":344,"correct":22},"净化装置回收",{"key":24,"text":346,"correct":26},"钢瓶回收",{"key":28,"text":348,"correct":26},"氧气瓶回收",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":20,"analysis":30},710307,"依据《中国南方电网有限责任公司电力安全工作规程》，试验工作结束后，应检查装置内无异物，屏面信号及各种装置状态正常，各相关压板及切换开关位置恢复至（ ）的状态。",[353,355,357],{"key":20,"text":354,"correct":22},"工作许可时",{"key":24,"text":356,"correct":26},"运行状态",{"key":28,"text":36,"correct":26},{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":20,"analysis":30},710308,"依据《中国南方电网有限责任公司电力安全工作规程》， 外单位在填写（ ）前，应由运行单位对外单位进行书面安全技术交底，并在安全技术交底单上由双方签名确认。",[362,363,365],{"key":20,"text":219,"correct":22},{"key":24,"text":364,"correct":26},"外单位任务许可单",{"key":28,"text":217,"correct":26},{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":20,"analysis":30},710309,"依据《中国南方电网有限责任公司电力安全工作规程》，同杆塔多回线路中部分线路停电的作业，向杆塔上吊起或向下放落工具、材料等物体时，应使用（ ）传递，物件与带电导线的安全距离应不小于规定。",[370,372,374],{"key":20,"text":371,"correct":22},"绝缘无极绳圈",{"key":24,"text":373,"correct":26},"吊篮",{"key":28,"text":375,"correct":26},"工具箱",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":20,"analysis":30},710310,"依据《中国南方电网有限责任公司电力安全工作规程》，已接上母线的备用间隔应有名称、编号。其隔离开关操作手柄、网门应能加锁。高压手车开关拉出后，（ ）应可靠封闭。",[380,382,383],{"key":20,"text":381,"correct":22},"隔离挡板",{"key":24,"text":80,"correct":26},{"key":28,"text":384,"correct":26},"柜门",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":24,"analysis":30},710311,"依据《中国南方电网有限责任公司电力安全工作规程》，低压施工用电架空线路应采用（ ），架设高度应不低于2.5m，交通要道及车辆通行处应不低于5m。",[389,391,393],{"key":20,"text":390,"correct":26},"普通电线",{"key":24,"text":392,"correct":22},"绝缘导线",{"key":28,"text":394,"correct":26},"绝缘电缆",{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":397,"options":398,"answer":24,"analysis":30},710312,"依据《中国南方电网有限责任公司电力安全工作规程》，灾后抢修应合理安排工期和资源，确保抢修作业人员的（ ）。",[399,401,403],{"key":20,"text":400,"correct":26},"工作条件",{"key":24,"text":402,"correct":22},"人身安全",{"key":28,"text":404,"correct":26},"作业环境",{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":24,"analysis":30},710313,"依据《中国南方电网有限责任公司电力安全工作规程》，工作间断，在（ ）的情况下重新办理许可手续时，可不进行以手触试。",[409,411,413],{"key":20,"text":410,"correct":26},"不增加工作内容",{"key":24,"text":412,"correct":22},"安全措施不变",{"key":28,"text":414,"correct":26},"不增加工作人员",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":24,"analysis":30},710314,"依据《中国南方电网有限责任公司电力安全工作规程》，从SF6气体钢瓶引出气体时，应使用（ ）。当瓶内压力降至9.8×104Pa（1个大气压）时，即停止引出气体，并关紧气瓶阀门，戴上瓶帽，防止气体泄漏。",[419,421,423],{"key":20,"text":420,"correct":26},"普通气阀减压",{"key":24,"text":422,"correct":22},"减压阀降压",{"key":28,"text":424,"correct":26},"增压阀增压",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":24,"analysis":30},710315,"依据《中国南方电网有限责任公司电力安全工作规程》，主控制室与SF6电气设备室间要采取（ ）。SF6电气设备室与其下方电缆层、电缆隧道相通的孔洞都应封堵。SF6电气设备室及下方电缆层隧道的门上，应设置“注意通风”的标志。",[429,431,433],{"key":20,"text":430,"correct":26},"定期检测仪检测",{"key":24,"text":432,"correct":22},"气密性隔离措施",{"key":28,"text":434,"correct":26},"开启通风系统",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":24,"analysis":30},710316,"依据《中国南方电网有限责任公司电力安全工作规程》，在SF6电气设备室低位区应安装（ ）的氧量仪和SF6气体泄漏警报仪。",[439,441,443],{"key":20,"text":440,"correct":26},"会报时",{"key":24,"text":442,"correct":22},"能报警",{"key":28,"text":444,"correct":26},"能测温",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":24,"analysis":30},710317,"依据《中国南方电网有限责任公司电力安全工作规程》，低压电气工作前，应用（ ）检验检修设备、金属外壳和相邻设备是否有电。",[449,451,453],{"key":20,"text":450,"correct":26},"高压发生器",{"key":24,"text":452,"correct":22},"低压验电器",{"key":28,"text":454,"correct":26},"验电笔",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":24,"analysis":30},710318,"依据《中国南方电网有限责任公司电力安全工作规程》，融冰作业前，应确认待融冰线路（含导线、地线、OPGW光缆）及有关装置对塔身等接地体的距离满足（ ）的安全要求。",[459,460,462],{"key":20,"text":128,"correct":26},{"key":24,"text":461,"correct":22},"融冰电压不击穿",{"key":28,"text":463,"correct":26},"绝缘遮蔽",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":24,"analysis":30},710319,"依据《中国南方电网有限责任公司电力安全工作规程》，使用挥发性的药品时应戴口罩、防护眼镜及橡胶手套；操作时必须在通风柜内或通风良好的地方进行，并应（ ）；接触过的器皿应及时清洗干净。",[468,470,472],{"key":20,"text":469,"correct":26},"封闭隔离",{"key":24,"text":471,"correct":22},"远离火源",{"key":28,"text":473,"correct":26},"绝缘隔离",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":24,"analysis":30},710320,"依据《中国南方电网有限责任公司电力安全工作规程》，为防止客户侧反送电，停电操作前，设备运维管理单位应提前通知双电源和有自备电源的用电客户断开（ ）的线路断路器、隔离开关，并监督用户实施，确认设备状态后做好记录。",[478,480,482],{"key":20,"text":479,"correct":26},"断开点",{"key":24,"text":481,"correct":22},"并网点",{"key":28,"text":483,"correct":26},"串联点",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":24,"analysis":30},710321,"依据《中国南方电网有限责任公司电力安全工作规程》，带电作业应设（ ）。监护人不应直接操作，其监护的范围不应超过一个作业点。复杂的或高杆塔上的带电作业，应增设监护人。",[488,489,491],{"key":20,"text":50,"correct":26},{"key":24,"text":490,"correct":22},"专责监护人",{"key":28,"text":492,"correct":26},"专业指挥",{"id":494,"libraryId":5,"type":15,"typeLabel":16,"stem":495,"options":496,"answer":24,"analysis":30},710322,"依据《中国南方电网有限责任公司电力安全工作规程》，高压配电线路带电立、撤杆时，应使用（ ）控制电杆的起立，其强度应符合规定。",[497,499,501],{"key":20,"text":498,"correct":26},"吊车",{"key":24,"text":500,"correct":22},"绝缘绳索",{"key":28,"text":502,"correct":26},"手扳葫芦",[504,507,510,512,515,518],{"id":505,"name":506,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":508,"name":509,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":511,"name":509,"category":7,"favorite":8},336,{"id":513,"name":514,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":516,"name":517,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":519,"name":520,"category":7,"favorite":8},353,"(N1)叉车司机"]