[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-374-5":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":498},{"id":5,"name":6,"category":7,"favorite":8},374,"安规题库","特种作业",0,5,50,960,[13,31,41,51,61,71,81,91,101,111,121,130,140,150,160,167,177,186,196,206,216,226,234,242,250,260,270,280,290,300,310,320,330,338,348,358,368,377,387,395,404,414,422,430,440,449,459,468,478,488],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":30},710223,1,"单选题","依据《中国南方电网有限责任公司电力安全工作规程》，跨越不停电线路时，施工人员不应在跨越架内侧攀登、作业，或从（ ）通过。",[19,23,27],{"key":20,"text":21,"correct":22},"A","封顶架上",true,{"key":24,"text":25,"correct":26},"B","地面",false,{"key":28,"text":29,"correct":26},"C","溜索","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":20,"analysis":30},710224,"依据《中国南方电网有限责任公司电力安全工作规程》，在交通道口使用软跨时，施工地段两侧应设立（ ），控制绳索人员应注意交通安全。",[35,37,39],{"key":20,"text":36,"correct":22},"交通警示标志牌",{"key":24,"text":38,"correct":26},"跨越架",{"key":28,"text":40,"correct":26},"人员巡视",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":20,"analysis":30},710225,"依据《中国南方电网有限责任公司电力安全工作规程》，采用以旧线带新线的方式施工，应检查确认旧导线完好牢固；若放线通道中有带电线路和带电设备，应与之保持安全距离，无法保证安全距离时应采取（ ）等措施或停电。牵引过程中应安排专人跟踪新旧导线连接点，发现问题立即通知停止牵引。",[45,47,49],{"key":20,"text":46,"correct":22},"搭设跨越架",{"key":24,"text":48,"correct":26},"派人看守",{"key":28,"text":50,"correct":26},"设置警示标示",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":20,"analysis":30},710226,"依据《中国南方电网有限责任公司电力安全工作规程》，在交通道口采取（ ）施工时，应采取措施防止车辆挂碰施工线路。",[55,57,59],{"key":20,"text":56,"correct":22},"无跨越架",{"key":24,"text":58,"correct":26},"无隔离栏",{"key":28,"text":60,"correct":26},"无指挥人员",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":20,"analysis":30},710227,"依据《中国南方电网有限责任公司电力安全工作规程》，风力超过（ ）时，不应砍剪高出或接近导线的树木。",[65,67,69],{"key":20,"text":66,"correct":22},"5级",{"key":24,"text":68,"correct":26},"6级",{"key":28,"text":70,"correct":26},"7级",{"id":72,"libraryId":5,"type":15,"typeLabel":16,"stem":73,"options":74,"answer":20,"analysis":30},710228,"依据《中国南方电网有限责任公司电力安全工作规程》，在电缆隧道内工作时，通风设备应保持常开，以保证空气流通。在通风条件不良的电缆隧道内进行长距离巡视时，工作人员应携带便携式有害气体测试仪及（ ）。",[75,77,79],{"key":20,"text":76,"correct":22},"自救呼吸器",{"key":24,"text":78,"correct":26},"防毒面具",{"key":28,"text":80,"correct":26},"正压式呼吸器",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":20,"analysis":30},710229,"依据《中国南方电网有限责任公司电力安全工作规程》，禁止带电插拔（ ）电缆终端接头。可带电插拔的肘型电缆终端接头，不得带负荷操作。带电插拔肘型电缆终端接头时应使用绝缘操作棒并戴绝缘手套、护目镜。",[85,87,89],{"key":20,"text":86,"correct":22},"普通型",{"key":24,"text":88,"correct":26},"肘型",{"key":28,"text":90,"correct":26},"螺栓式",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":20,"analysis":30},710230,"依据《中国南方电网有限责任公司电力安全工作规程》，在电缆通道内不应使用大型机械开挖沟槽，硬路面面层破碎可使用小型机械设备，但应有专人监护，不得（ ）。若要使用大型机械设备时，应履行相应的报批手续。",[95,97,99],{"key":20,"text":96,"correct":22},"深入土层",{"key":24,"text":98,"correct":26},"上级报批",{"key":28,"text":100,"correct":26},"防止电缆带电",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":20,"analysis":30},710231,"依据《中国南方电网有限责任公司电力安全工作规程》，挖掘出的电缆或接头盒，如下面需要挖空时，应采取（ ）。电缆悬吊应每1m～1.5m吊一道；接头盒悬吊应平放，不得使接头盒受到拉力；若电缆接头无保护盒，应做好充分保护措施，方可悬吊。",[105,107,109],{"key":20,"text":106,"correct":22},"悬吊保护措施",{"key":24,"text":108,"correct":26},"固定保护措施",{"key":28,"text":110,"correct":26},"隔离保护措施",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":20,"analysis":30},710232,"依据《中国南方电网有限责任公司电力安全工作规程》，电力电缆试验要拆除接地线时，应征得（ ）的许可（根据调度员命令装设的接地线，应征得调度员的许可），方可进行。工作完毕后立即恢复。",[115,117,119],{"key":20,"text":116,"correct":22},"工作许可人",{"key":24,"text":118,"correct":26},"工作负责人",{"key":28,"text":120,"correct":26},"值班负责人",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":20,"analysis":30},710233,"依据《中国南方电网有限责任公司电力安全工作规程》，电缆耐压试验前，加压端应做好安全措施，防止人员误入试验场所。另一端应设置围栏并挂上警告标示牌。如另一端是上杆的或是锯断电缆处，应（ ）。",[125,126,128],{"key":20,"text":48,"correct":22},{"key":24,"text":127,"correct":26},"拆除安全措施",{"key":28,"text":129,"correct":26},"设置围栏",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":20,"analysis":30},710234,"依据《中国南方电网有限责任公司电力安全工作规程》，电缆试验结束，应对被试电缆进行充分放电，并在被试电缆上加装（ ），待电缆尾线接通后方可拆除。",[134,136,138],{"key":20,"text":135,"correct":22},"临时接地线",{"key":24,"text":137,"correct":26},"围栏",{"key":28,"text":139,"correct":26},"标识牌",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":20,"analysis":30},710235,"依据《中国南方电网有限责任公司电力安全工作规程》，10kV户外电力装置的裸露部分在跨越人行过道或作业区时，若导电部分对地高度小于（ ）时，该裸露部分两侧和底部应装设护网。",[144,146,148],{"key":20,"text":145,"correct":22},"2.7m",{"key":24,"text":147,"correct":26},"2.8m",{"key":28,"text":149,"correct":26},"2.9m",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":20,"analysis":30},710236,"依据《中国南方电网有限责任公司电力安全工作规程》，金属材料的配电箱、电表箱应可靠接地，且接地电阻应满足要求。工作人员在接触运用中的配电箱、电表箱前，应检查接地装置是否良好，并用（ ）确认箱体确无电压后，方可接触。带电接电时作业人员应戴绝缘手套。",[154,156,158],{"key":20,"text":155,"correct":22},"验电笔",{"key":24,"text":157,"correct":26},"低压验电器",{"key":28,"text":159,"correct":26},"高压发生器",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":20,"analysis":30},710237,"依据《中国南方电网有限责任公司电力安全工作规程》，配电设备中使用的（ ）电缆接头，禁止带电插拔。可带电插拔的肘型电缆接头，不宜带负荷操作。",[164,165,166],{"key":20,"text":86,"correct":22},{"key":24,"text":88,"correct":26},{"key":28,"text":90,"correct":26},{"id":168,"libraryId":5,"type":15,"typeLabel":16,"stem":169,"options":170,"answer":20,"analysis":30},710238,"依据《中国南方电网有限责任公司电力安全工作规程》，在配电设备区进行清洁、维护等不触及运行设备的工作时，应有人监护，保持作业人员与带电部分的距离应符规定的作业安全距离，并采取（ ）的可靠措施。",[171,173,175],{"key":20,"text":172,"correct":22},"防止误碰带电设备",{"key":24,"text":174,"correct":26},"防止交通事故",{"key":28,"text":176,"correct":26},"防止土层塌方",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":20,"analysis":30},710239,"依据《中国南方电网有限责任公司电力安全工作规程》，配电变压器柜的柜门应有（ ）的措施，新设备应安装防止误入带电间隔闭锁装置。",[181,183,184],{"key":20,"text":182,"correct":22},"防误入带电间隔",{"key":24,"text":172,"correct":26},{"key":28,"text":185,"correct":26},"防止反送电",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":20,"analysis":30},710240,"依据《中国南方电网有限责任公司电力安全工作规程》，杆塔上带电核相时，作业人员与带电部位的距离应符合规定的作业安全距离，核相工作应（ ）。",[190,192,194],{"key":20,"text":191,"correct":22},"逐相进行",{"key":24,"text":193,"correct":26},"三相同时进行",{"key":28,"text":195,"correct":26},"可靠接地",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":20,"analysis":30},710241,"依据《中国南方电网有限责任公司电力安全工作规程》，柱上断路器应有分、合位置的（ ）。",[200,202,204],{"key":20,"text":201,"correct":22},"机械指示",{"key":24,"text":203,"correct":26},"表计标示",{"key":28,"text":205,"correct":26},"检验开关",{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":20,"analysis":30},710242,"依据《中国南方电网有限责任公司电力安全工作规程》，柱上变压器台架工作，人体与高压线路和跌落式熔断器上部带电部分应保持安全距离。不宜在跌落式熔断器下部新装、调换引线；若必须进行，应（ ）或将跌落式熔断器上部停电。",[210,212,214],{"key":20,"text":211,"correct":22},"采用带电作业方式进行",{"key":24,"text":213,"correct":26},"采取防感应电的措施",{"key":28,"text":215,"correct":26},"采用绝缘遮蔽措施",{"id":217,"libraryId":5,"type":15,"typeLabel":16,"stem":218,"options":219,"answer":20,"analysis":30},710243,"依据《中国南方电网有限责任公司电力安全工作规程》，应在架空绝缘导线的适当位置设立（ ）或其他验电接地装置。",[220,222,224],{"key":20,"text":221,"correct":22},"验电接地环",{"key":24,"text":223,"correct":26},"分支接头",{"key":28,"text":225,"correct":26},"电缆端头",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":20,"analysis":30},710244,"依据《中国南方电网有限责任公司电力安全工作规程》，低压屏（柜）内需要低压出线停电的工作，应断开相应出线的空气开关，并在低压出线电缆头上验电、装设接地线，以（ ）。",[230,232,233],{"key":20,"text":231,"correct":22},"防止向工作地点反送电",{"key":24,"text":213,"correct":26},{"key":28,"text":215,"correct":26},{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":20,"analysis":30},710245,"依据《中国南方电网有限责任公司电力安全工作规程》，低压不停电作业人员应使用有绝缘柄的工具，其外裸露的导电部位应（ ），禁止使用锉刀、金属尺和带有金属物的毛刷、毛掸等工具。",[238,240,241],{"key":20,"text":239,"correct":22},"采取绝缘包裹措施",{"key":24,"text":213,"correct":26},{"key":28,"text":215,"correct":26},{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":20,"analysis":30},710246,"依据《中国南方电网有限责任公司电力安全工作规程》，在高低压线路同杆塔架设的低压带电线路上工作时，应先检查与高压线的距离，（ ）。在下层低压带电导线未采取绝缘隔离措施或未停电接地时，作业人员不应穿越。",[246,248,249],{"key":20,"text":247,"correct":22},"采取防止误碰带电高压设备的措施",{"key":24,"text":213,"correct":26},{"key":28,"text":215,"correct":26},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":20,"analysis":30},710247,"136．任何人员发现有违反《中国南方电网有限责任公司电力安全工作规程》的，应立即制止，经（ ）后方可恢复工作。",[254,256,258],{"key":20,"text":255,"correct":22},"纠正",{"key":24,"text":257,"correct":26},"培训",{"key":28,"text":259,"correct":26},"处罚",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":20,"analysis":30},710248,"依据《中国南方电网有限责任公司电力安全工作规程》， 在城区、人口密集区、通行道路上或交通道口施工时，工作场所周围应装设遮栏（围栏），并在相应部位设警戒范围或警示标识，夜间应设警示光源，必要时（ ）。",[264,266,268],{"key":20,"text":265,"correct":22},"派专人看守",{"key":24,"text":267,"correct":26},"设遮栏(围栏)",{"key":28,"text":269,"correct":26},"装警示标识",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":20,"analysis":30},710249,"依据《中国南方电网有限责任公司电力安全工作规程》，在厂站的带电区域内或邻近带电导体附近，禁止使用（ ）；搬动梯子、管子等长物应将其放倒后，宜由两人搬运，并与带电部分保持足够的安全距离。",[274,276,278],{"key":20,"text":275,"correct":22},"金属梯子",{"key":24,"text":277,"correct":26},"绝缘梯子",{"key":28,"text":279,"correct":26},"竹梯子",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":20,"analysis":30},710250,"依据《中国南方电网有限责任公司电力安全工作规程》，施工用电设施应由取得资质的人员安装维护，严禁私拉乱接，( )将电线直接钩挂在闸刀上或直接插入插座内使用。",[284,286,288],{"key":20,"text":285,"correct":22},"严禁",{"key":24,"text":287,"correct":26},"可以",{"key":28,"text":289,"correct":26},"允许",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":20,"analysis":30},710251,"依据《中国南方电网有限责任公司电力安全工作规程》，敷设在地面上的施工用电线路应采用（ ），交通车辆通行路面上的电缆应设有防碾压的措施。",[294,296,298],{"key":20,"text":295,"correct":22},"绝缘电缆",{"key":24,"text":297,"correct":26},"普通电线",{"key":28,"text":299,"correct":26},"普通导线",{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":20,"analysis":30},710252,"依据《中国南方电网有限责任公司电力安全工作规程》，全部作业结束，作业人员撤离现场后、办理作业终结前，任何人员未经工作负责人许可，不得（ ）。",[304,306,308],{"key":20,"text":305,"correct":22},"进入工作现场",{"key":24,"text":307,"correct":26},"离开",{"key":28,"text":309,"correct":26},"重新验电装设接地线",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":20,"analysis":30},710253,"依据《中国南方电网有限责任公司电力安全工作规程》，公司所属设备运维单位认为有必要进行（ ）的内部工作负责人，应根据工作要求组织现场勘察。",[314,316,318],{"key":20,"text":315,"correct":22},"勘察工作",{"key":24,"text":317,"correct":26},"任务观察",{"key":28,"text":319,"correct":26},"安全监督",{"id":321,"libraryId":5,"type":15,"typeLabel":16,"stem":322,"options":323,"answer":20,"analysis":30},710254,"依据《中国南方电网有限责任公司电力安全工作规程》，作业开工前，工作负责人或工作许可人若认为现场实际情况与原勘察结果可能发生变化时，应重新核实，必要时应修正、完善相应的安全措施，或重新（ ）。",[324,326,328],{"key":20,"text":325,"correct":22},"办理工作票",{"key":24,"text":327,"correct":26},"进行勘察",{"key":28,"text":329,"correct":26},"办理停电申请",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":20,"analysis":30},710255,"依据《中国南方电网有限责任公司电力安全工作规程》，配电作业运检一体，工作票签发人可由（ ）兼任，但工作许可人和工作负责人不得相互兼任。",[334,335,336],{"key":20,"text":116,"correct":22},{"key":24,"text":118,"correct":26},{"key":28,"text":337,"correct":26},"工作票会签人",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":20,"analysis":30},710256,"依据《中国南方电网有限责任公司电力安全工作规程》，在电气设备上或生产场所工作，应根据工作性质选用相应的（ ）、检修申请单或规范性书面记录。",[342,344,346],{"key":20,"text":343,"correct":22},"电气工作票",{"key":24,"text":345,"correct":26},"动火作业票",{"key":28,"text":347,"correct":26},"电气操作票",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":20,"analysis":30},710257,"依据《中国南方电网有限责任公司电力安全工作规程》，若一张工作票下设多个分组工作，每个分组应分别指定分组工作负责人（监护人），并使用分组（ ）。",[352,354,356],{"key":20,"text":353,"correct":22},"工作派工单",{"key":24,"text":355,"correct":26},"抢修工作票",{"key":28,"text":357,"correct":26},"工作票",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":20,"analysis":30},710258,"依据《中国南方电网有限责任公司电力安全工作规程》，填写工作班人员，不分组时应填写除工作负责人以外的（ ）姓名。工作班分组时，填写工作小组负责人姓名，并注明包括该小组负责人在内的小组总人数；工作负责人兼任一个分组负责人时，应重复填写工作负责人姓名。",[362,364,366],{"key":20,"text":363,"correct":22},"所有工作人员",{"key":24,"text":365,"correct":26},"小组负责人",{"key":28,"text":367,"correct":26},"配合工作人员",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":20,"analysis":30},710259,"依据《中国南方电网有限责任公司电力安全工作规程》，（ ）收到工作票后应及时审核，确认无误后签名接收。",[372,373,375],{"key":20,"text":120,"correct":22},{"key":24,"text":374,"correct":26},"调度员",{"key":28,"text":376,"correct":26},"运检人员",{"id":378,"libraryId":5,"type":15,"typeLabel":16,"stem":379,"options":380,"answer":20,"analysis":30},710260,"依据《中国南方电网有限责任公司电力安全工作规程》，工作许可人、工作负责人任何一方不得擅自变更（ ）。工作中若有特殊情况需要变更时，应先征得对方同意，并及时恢复，变更及恢复情况应及时记录。",[381,383,385],{"key":20,"text":382,"correct":22},"安全措施",{"key":24,"text":384,"correct":26},"组织措施",{"key":28,"text":386,"correct":26},"管理措施",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":20,"analysis":30},710261,"依据《中国南方电网有限责任公司电力安全工作规程》，（ ）审查工作票或调度检修申请单无误后，正确完整地组织实施各项安全措施并做好安全注意事项的提醒。",[391,392,394],{"key":20,"text":120,"correct":22},{"key":24,"text":393,"correct":26},"工作人员",{"key":28,"text":118,"correct":26},{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":397,"options":398,"answer":20,"analysis":30},710262,"依据《中国南方电网有限责任公司电力安全工作规程》，值班人员按照值班负责人的安排，具体实施或组织完成（ ）的布置工作。",[399,400,402],{"key":20,"text":382,"correct":22},{"key":24,"text":401,"correct":26},"技术措施",{"key":28,"text":403,"correct":26},"隔离措施",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":20,"analysis":30},710263,"依据《中国南方电网有限责任公司电力安全工作规程》，“以手触试”原则上适用于（ ）许可工作。能触试的设备应以手触试，若工作负责人不作要求则可不以手触试。",[408,410,412],{"key":20,"text":409,"correct":22},"所有停电",{"key":24,"text":411,"correct":26},"部分停电",{"key":28,"text":413,"correct":26},"局部停电",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":20,"analysis":30},710264,"依据《中国南方电网有限责任公司电力安全工作规程》，工作许可人许可前应核对（ ）身份与工作票填写工作负责人身份是否相符，核对实际工作人数与工作票填写的工作人数是否一致。",[418,419,421],{"key":20,"text":118,"correct":22},{"key":24,"text":420,"correct":26},"工作票签发人",{"key":28,"text":120,"correct":26},{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":20,"analysis":30},710265,"依据《中国南方电网有限责任公司电力安全工作规程》，持已许可的线路工作票或分组工作派工单进入厂站工作，厂站值班人员应先得到（ ）同意，并与工作负责人明确工作地点及相关安全注意事项，在备注栏填写调度许可人姓名后由厂站值班人员和工作负责人双方签名，方可进行工作。",[426,428,429],{"key":20,"text":427,"correct":22},"调度许可人",{"key":24,"text":120,"correct":26},{"key":28,"text":118,"correct":26},{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":20,"analysis":30},710266,"依据《中国南方电网有限责任公司电力安全工作规程》，末级工作许可人在向工作负责人发出（ ）的命令前，应将工作班组名称、工作负责人姓名、工作地点、工作任务和联系电话做好记录。",[434,436,438],{"key":20,"text":435,"correct":22},"许可工作",{"key":24,"text":437,"correct":26},"可以操作",{"key":28,"text":439,"correct":26},"操作指令",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":20,"analysis":30},710267,"依据《中国南方电网有限责任公司电力安全工作规程》，低压配电网的停电工作时，工作许可人应按工作票所列的（ ）落实完备后与工作负责人办理工作许可手续。",[444,445,447],{"key":20,"text":382,"correct":22},{"key":24,"text":446,"correct":26},"注意事项",{"key":28,"text":448,"correct":26},"施工方案",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":20,"analysis":30},710268,"依据《中国南方电网有限责任公司电力安全工作规程》，线路工作时，工作负责人办理完成（ ），在工作地段各端装设好接地线，落实现场其他所需安全措施后，方可开始工作。",[453,455,457],{"key":20,"text":454,"correct":22},"工作许可手续",{"key":24,"text":456,"correct":26},"停电检修申请",{"key":28,"text":458,"correct":26},"施工人员安排",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":20,"analysis":30},710269,"依据《中国南方电网有限责任公司电力安全工作规程》，若一张工作票设多个分组工作，分组工作负责人即为该分组的（ ）。",[463,465,467],{"key":20,"text":464,"correct":22},"监护人",{"key":24,"text":466,"correct":26},"班组长",{"key":28,"text":120,"correct":26},{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":20,"analysis":30},710270,"依据《中国南方电网有限责任公司电力安全工作规程》，在可能存在有交叉、间歇带电的设备上作业，或在一个电气连接部分进行多专业协同作业时，工作负责人应专职监护，不得（ ）。",[472,474,476],{"key":20,"text":473,"correct":22},"参与作业",{"key":24,"text":475,"correct":26},"干预工作",{"key":28,"text":477,"correct":26},"做与职责无关的工作",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":20,"analysis":30},710271,"依据《中国南方电网有限责任公司电力安全工作规程》，室外工作，如遇雷、雨、风等恶劣天气或其他可能危及（ ）的情况时，工作负责人或专责监护人根据实际情况，有权决定临时停止工作。",[482,484,486],{"key":20,"text":483,"correct":22},"作业人员安全",{"key":24,"text":485,"correct":26},"电网安全",{"key":28,"text":487,"correct":26},"运行设备安全",{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":20,"analysis":30},710272,"依据《中国南方电网有限责任公司电力安全工作规程》，电话许可的（ ）时，工作票可不交回工作许可人，但要与工作许可人电话确认，并在工作票上做好记录。",[492,494,496],{"key":20,"text":493,"correct":22},"工作间断",{"key":24,"text":495,"correct":26},"工作终结",{"key":28,"text":497,"correct":26},"工作许可",[499,502,505,507,510,513],{"id":500,"name":501,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":503,"name":504,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":506,"name":504,"category":7,"favorite":8},336,{"id":508,"name":509,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":511,"name":512,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":514,"name":515,"category":7,"favorite":8},353,"(N1)叉车司机"]