[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-374-4":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":510},{"id":5,"name":6,"category":7,"favorite":8},374,"安规题库","特种作业",0,4,50,960,[13,31,41,51,61,71,81,91,101,111,121,131,141,150,160,170,180,190,200,209,219,229,239,249,258,268,278,287,296,306,316,325,335,344,354,364,374,384,392,402,411,421,430,440,450,460,470,480,490,500],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":30},710173,1,"单选题","依据《中国南方电网有限责任公司电力安全工作规程》，工作人员不应在SF6设备（ ）附近停留，SF6设备防爆膜应有明显标志。",[19,23,27],{"key":20,"text":21,"correct":22},"A","防爆膜",true,{"key":24,"text":25,"correct":26},"B","压力表",false,{"key":28,"text":29,"correct":26},"C","操作机构","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":20,"analysis":30},710174,"依据《中国南方电网有限责任公司电力安全工作规程》，低压屏（柜）内需要低压出线停电的工作，应断开相应出线空气开关，并在低压出线电缆头上验电、装设接地线，以防止向工作地点（ ）。",[35,37,39],{"key":20,"text":36,"correct":22},"反送电",{"key":24,"text":38,"correct":26},"感应电",{"key":28,"text":40,"correct":26},"相间短路",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":20,"analysis":30},710175,"依据《中国南方电网有限责任公司电力安全工作规程》，（ ）：是指将覆冰线路停电后，将线路两侧调度管辖的厂站接地刀闸（临时接地线）、融冰装置网侧断路器及相关接地刀闸的调度操作权，移交给融冰工作组自行负责并开展融冰作业。",[45,47,49],{"key":20,"text":46,"correct":22},"工作组指挥模式",{"key":24,"text":48,"correct":26},"工作负责人指挥模式",{"key":28,"text":50,"correct":26},"调度员指挥模式",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":20,"analysis":30},710176,"依据《中国南方电网有限责任公司电力安全工作规程》，线路融冰作业，在装设好导线与地线之间的连接线后，应拆除导线接地线，并拉开（ ）。",[55,57,59],{"key":20,"text":56,"correct":22},"地线接地刀闸",{"key":24,"text":58,"correct":26},"线路隔离开关",{"key":28,"text":60,"correct":26},"线路耦合电容器",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":20,"analysis":30},710177,"依据《中国南方电网有限责任公司电力安全工作规程》线路融冰作业时，裸露的连接线应盘卷放置在绝缘架上，用（ ）包好，悬空放置，不能与塔材接触。",[65,67,69],{"key":20,"text":66,"correct":22},"绝缘护套",{"key":24,"text":68,"correct":26},"报纸",{"key":28,"text":70,"correct":26},"锡纸",{"id":72,"libraryId":5,"type":15,"typeLabel":16,"stem":73,"options":74,"answer":20,"analysis":30},710178,"依据《中国南方电网有限责任公司电力安全工作规程》，试管加热时不应将（ ）朝向自己或别人，刚加热过的玻璃仪器不应接触皮肤及冷水。",[75,77,79],{"key":20,"text":76,"correct":22},"试管口",{"key":24,"text":78,"correct":26},"加热器",{"key":28,"text":80,"correct":26},"试纸",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":20,"analysis":30},710179,"依据《中国南方电网有限责任公司电力安全工作规程》，装有药品的瓶子上应贴上明显的标签，并分类存放。严禁使用（ ）的药品。",[85,87,89],{"key":20,"text":86,"correct":22},"没有标签",{"key":24,"text":88,"correct":26},"无审核标签",{"key":28,"text":90,"correct":26},"无检验合格证",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":20,"analysis":30},710180,"依据《中国南方电网有限责任公司电力安全工作规程》，为防止客户侧反送电，作业前，应检查双电源和有自备电源的客户已采取机械或电气联锁等防反送的强制性技术措施，确保有明显的（ ）。",[95,97,99],{"key":20,"text":96,"correct":22},"断开点",{"key":24,"text":98,"correct":26},"并网点",{"key":28,"text":100,"correct":26},"串联点",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":20,"analysis":30},710181,"依据《中国南方电网有限责任公司电力安全工作规程》，带电作业人员应经专门培训，并经考试合格取得资格、本单位书面批准后，方可参加相应的作业。带电作业工作票签发人和工作负责人、专责监护人应由具有带电作业实践经验的人员担任。工作负责人、专责监护人应（ ）。",[105,107,109],{"key":20,"text":106,"correct":22},"具备带电作业资格",{"key":24,"text":108,"correct":26},"三种人资格",{"key":28,"text":110,"correct":26},"电工资格",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":20,"analysis":30},710182,"依据《中国南方电网有限责任公司电力安全工作规程》，采用旁路作业方式进行电缆线路不停电作业前，应确认两侧备用间隔断路器及旁路断路器均在（ ）。",[115,117,119],{"key":20,"text":116,"correct":22},"断开状态",{"key":24,"text":118,"correct":26},"运行状态",{"key":28,"text":120,"correct":26},"热备用状态",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":20,"analysis":30},710183,"依据《中国南方电网有限责任公司电力安全工作规程》，采用旁路作业方式进行电缆线路不停电作业时，旁路电缆两侧的环网柜等设备均应带（ ），并预留备用间隔。负荷电流应小于旁路系统额定电流。",[125,127,129],{"key":20,"text":126,"correct":22},"断路器",{"key":24,"text":128,"correct":26},"熔断器",{"key":28,"text":130,"correct":26},"电压互感器",{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":20,"analysis":30},710184,"依据《中国南方电网有限责任公司电力安全工作规程》，电缆旁路作业，旁路电缆屏蔽层应在两终端处引出并（ ），接地线的截面积不宜小于25mm2。",[135,137,139],{"key":20,"text":136,"correct":22},"可靠接地",{"key":24,"text":138,"correct":26},"绝缘屏蔽",{"key":28,"text":140,"correct":26},"短路接地",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":20,"analysis":30},710185,"依据《中国南方电网有限责任公司电力安全工作规程》，高压配电线路带电立、撤杆时，起重工器具、电杆与带电设备应始终保持有效的绝缘遮蔽或隔离措施，并有防止起重工器具、电杆等的绝缘防护及遮蔽器具（ ）或脱落的措施。",[145,147,149],{"key":20,"text":146,"correct":22},"绝缘损坏",{"key":24,"text":148,"correct":26},"漏气破损",{"key":28,"text":136,"correct":26},{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":20,"analysis":30},710186,"依据《中国南方电网有限责任公司电力安全工作规程》，绝缘平台金属支腿应装设（ ）。",[154,156,158],{"key":20,"text":155,"correct":22},"接地线",{"key":24,"text":157,"correct":26},"固定器",{"key":28,"text":159,"correct":26},"保护套",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":20,"analysis":30},710187,"依据《中国南方电网有限责任公司电力安全工作规程》，进行10kV地电位带电作业时，人身与带电体间的安全距离不得小于（ ）。",[164,166,168],{"key":20,"text":165,"correct":22},"0.4m",{"key":24,"text":167,"correct":26},"0.5m",{"key":28,"text":169,"correct":26},"0.6m",{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":20,"analysis":30},710188,"依据《中国南方电网有限责任公司电力安全工作规程》，高压配电线路带电作业绝缘遮蔽或隔离用具有（ ）的可能时，应采用可靠措施进行绑扎、固定。作业位置周围如有接地拉线和低压线等设施，不满足作业安全距离时，也应进行绝缘遮蔽或隔离。",[174,176,178],{"key":20,"text":175,"correct":22},"脱落",{"key":24,"text":177,"correct":26},"摆动",{"key":28,"text":179,"correct":26},"短接",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":20,"analysis":30},710189,"依据《中国南方电网有限责任公司电力安全工作规程》，在绝缘子串未脱离导线前，拆、装靠近横担的第一片绝缘子时，应采用专用短接线或（ ）方可直接进行操作。",[184,186,188],{"key":20,"text":185,"correct":22},"穿屏蔽服",{"key":24,"text":187,"correct":26},"穿防电弧服",{"key":28,"text":189,"correct":26},"戴绝缘手套",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":20,"analysis":30},710190,"依据《中国南方电网有限责任公司电力安全工作规程》，高压配电线路带电作业时，作业区域带电导线、绝缘子等应采取相间、相对地的（ ）及隔离措施。绝缘遮蔽、隔离措施的范围应比作业人员活动范围增加0.4m以上，绝缘遮蔽用具之间的接合处应重合15cm以上。",[194,196,198],{"key":20,"text":195,"correct":22},"绝缘遮蔽",{"key":24,"text":197,"correct":26},"安全技术",{"key":28,"text":199,"correct":26},"后备保护",{"id":201,"libraryId":5,"type":15,"typeLabel":16,"stem":202,"options":203,"answer":20,"analysis":30},710191,"依据《中国南方电网有限责任公司电力安全工作规程》，高压线路带电作业时，作业人员不应（ ）两个非连通的带电导体或带电导体与接地导体。",[204,206,207],{"key":20,"text":205,"correct":22},"同时接触",{"key":24,"text":195,"correct":26},{"key":28,"text":208,"correct":26},"绝缘隔离",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":20,"analysis":30},710192,"依据《中国南方电网有限责任公司电力安全工作规程》，等电位作业人员应穿着（ ），外面穿着全套屏蔽服，各部分应连接良好。不应通过屏蔽服断、接空载线路或耦合电容器的电容电流及接地电流。±800kV等电位作业人员还应戴面罩。",[213,215,217],{"key":20,"text":214,"correct":22},"阻燃内衣",{"key":24,"text":216,"correct":26},"短袖衬衫",{"key":28,"text":218,"correct":26},"长袖T恤",{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":221,"options":222,"answer":20,"analysis":30},710193,"依据《中国南方电网有限责任公司电力安全工作规程》，110kV等电位作业人员对接地体距离应不小于（ ），对邻相导线的距离应不小于（ ）。",[223,225,227],{"key":20,"text":224,"correct":22},"1.0m、1.4m",{"key":24,"text":226,"correct":26},"0.7m、1.0m",{"key":28,"text":228,"correct":26},"0.4m、1.0m",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":20,"analysis":30},710194,"依据《中国南方电网有限责任公司电力安全工作规程》，220kV等电位作业人员沿绝缘子串进入强电场的作业。在扣除人体短接的和零值的绝缘子片后，良好绝缘子片数不应小于（ ）片。其组合间隙不应小于（ ）m。若不满足规定，应加装保护间隙。",[233,235,237],{"key":20,"text":234,"correct":22},"9、2.1",{"key":24,"text":236,"correct":26},"5、1.2",{"key":28,"text":238,"correct":26},"3、1.2",{"id":240,"libraryId":5,"type":15,"typeLabel":16,"stem":241,"options":242,"answer":20,"analysis":30},710195,"依据《中国南方电网有限责任公司电力安全工作规程》，带电断、接耦合电容器时，应将其接地刀闸合上、停用（ ）和信号回路。被断开的电容器应立即对地放电。",[243,245,247],{"key":20,"text":244,"correct":22},"高频保护",{"key":24,"text":246,"correct":26},"差动保护",{"key":28,"text":248,"correct":26},"失灵保护",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":20,"analysis":30},710196,"依据《中国南方电网有限责任公司电力安全工作规程》，带电断、接空载线路、耦合电容器、避雷器、阻波器等设备引线时，应采取（ ）的措施。",[253,255,257],{"key":20,"text":254,"correct":22},"防止引流线摆动",{"key":24,"text":256,"correct":26},"接地短路",{"key":28,"text":208,"correct":26},{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":20,"analysis":30},710197,"依据《中国南方电网有限责任公司电力安全工作规程》，高压配电线路带电作业装、拆旁路引流线时，应在检查确认旁路引流线及原引流线通流正常后，方可拆除短接设备或（ ）。",[262,264,266],{"key":20,"text":263,"correct":22},"旁路引流线",{"key":24,"text":265,"correct":26},"线路出线",{"key":28,"text":267,"correct":26},"旁路隔离开关",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":20,"analysis":30},710198,"依据《中国南方电网有限责任公司电力安全工作规程》，高压配电线路带电短接故障线路、设备前，应确认（ ）已隔离。",[272,274,276],{"key":20,"text":273,"correct":22},"故障",{"key":24,"text":275,"correct":26},"人员",{"key":28,"text":277,"correct":26},"抢修现场",{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":280,"options":281,"answer":20,"analysis":30},710199,"依据《中国南方电网有限责任公司电力安全工作规程》，小型水冲工具进行冲洗时，冲洗工具不应（ ）。引水管的有效绝缘部分不应触及接地体。操作杆的使用和管理按带电作业工具的有关规定执行。",[282,284,286],{"key":20,"text":283,"correct":22},"接触带电体",{"key":24,"text":285,"correct":26},"调整水压",{"key":28,"text":208,"correct":26},{"id":288,"libraryId":5,"type":15,"typeLabel":16,"stem":289,"options":290,"answer":20,"analysis":30},710200,"依据《中国南方电网有限责任公司电力安全工作规程》，在使用带电清扫机械进行清扫前，应确认清扫机械的电机及控制、软轴及传动等部分工况完好，绝缘部件无变形、脏污和损伤，毛刷转向正确，清扫机械已（ ）。",[291,292,294],{"key":20,"text":136,"correct":22},{"key":24,"text":293,"correct":26},"派人监护",{"key":28,"text":295,"correct":26},"办理抢修单",{"id":297,"libraryId":5,"type":15,"typeLabel":16,"stem":298,"options":299,"answer":20,"analysis":30},710201,"依据《中国南方电网有限责任公司电力安全工作规程》，带电清扫作业时，作业人的双手应始终握持（ ）以下部位，并保持带电清扫有关绝缘部件的清洁和干燥。",[300,302,304],{"key":20,"text":301,"correct":22},"绝缘杆保护环",{"key":24,"text":303,"correct":26},"防雨罩",{"key":28,"text":305,"correct":26},"绝缘臂",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":20,"analysis":30},710202,"依据《中国南方电网有限责任公司电力安全工作规程》，10kV绝缘斗臂车的绝缘臂的有效绝缘长度应大于（ ），并应在其下端装设泄漏电流监视装置。",[310,312,314],{"key":20,"text":311,"correct":22},"1.0m",{"key":24,"text":313,"correct":26},"0.9m",{"key":28,"text":315,"correct":26},"0.8m",{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":20,"analysis":30},710203,"依据《中国南方电网有限责任公司电力安全工作规程》，绝缘臂下节的金属部分，在仰起回转过程中，对带电体的距离应按规定值增加0.5m。工作中车体应( )。",[320,322,323],{"key":20,"text":321,"correct":22},"良好接地",{"key":24,"text":138,"correct":26},{"key":28,"text":324,"correct":26},"熄火",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":20,"analysis":30},710204,"依据《中国南方电网有限责任公司电力安全工作规程》，高压配电线路带电作业时，不应使用绝缘斗（ ）。",[329,331,333],{"key":20,"text":330,"correct":22},"支撑导线",{"key":24,"text":332,"correct":26},"装载工作人员",{"key":28,"text":334,"correct":26},"装载工器具",{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":20,"analysis":30},710205,"依据《中国南方电网有限责任公司电力安全工作规程》，绝缘架空地线（包括OPGW、ADSS光缆）应视为带电体。在绝缘架空地线附近作业时，工作人员与绝缘架空地线之间的距离应不小于（ ）。若需在绝缘架空地线上作业，应用接地线或个人保安地线将其可靠接地或采用等电位方式进行。",[339,340,342],{"key":20,"text":165,"correct":22},{"key":24,"text":341,"correct":26},"0.3m",{"key":28,"text":343,"correct":26},"0.2m",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":20,"analysis":30},710206,"依据《中国南方电网有限责任公司电力安全工作规程》，带电更换架空地线或架设耦合地线时，应通过（ ）可靠接地。",[348,350,352],{"key":20,"text":349,"correct":22},"金属滑车",{"key":24,"text":351,"correct":26},"接地桩",{"key":28,"text":353,"correct":26},"临时接地体",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":20,"analysis":30},710207,"依据《中国南方电网有限责任公司电力安全工作规程》，风力大于（ ）时应停止在带电线路杆塔上的作业。",[358,360,362],{"key":20,"text":359,"correct":22},"5级",{"key":24,"text":361,"correct":26},"6级",{"key":28,"text":363,"correct":26},"8级",{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":20,"analysis":30},710208,"依据《中国南方电网有限责任公司电力安全工作规程》，停电检修的线路如与另一回带电线路相交叉或接近，以致工作人员和工器具可能和另一回导线接触或接近规定的安全距离，则另一回线路也应（ ），接地线可以只在工作地点附近安装一处，工作中应采取防止损伤另一回线的措施。",[368,370,372],{"key":20,"text":369,"correct":22},"停电并接地",{"key":24,"text":371,"correct":26},"带电运行",{"key":28,"text":373,"correct":26},"搭设跨越架",{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":376,"options":377,"answer":20,"analysis":30},710209,"依据《中国南方电网有限责任公司电力安全工作规程》，邻近或交叉其他电力线路的工作应设（ ），以防误登带电线路杆塔。",[378,380,382],{"key":20,"text":379,"correct":22},"专人监护",{"key":24,"text":381,"correct":26},"警示标示",{"key":28,"text":383,"correct":26},"围栏",{"id":385,"libraryId":5,"type":15,"typeLabel":16,"stem":386,"options":387,"answer":20,"analysis":30},710210,"依据《中国南方电网有限责任公司电力安全工作规程》，10kV同杆塔多回线路中部分线路或直流线路中单极线路停电检修，安全距离是（ ）。",[388,390,391],{"key":20,"text":389,"correct":22},"0.7m",{"key":24,"text":315,"correct":26},{"key":28,"text":311,"correct":26},{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":20,"analysis":30},710211,"依据《中国南方电网有限责任公司电力安全工作规程》，二次措施单作为工作票必要的补充，宜与（ ）同步填写。二次措施单的正确性和具体执行由工作负责人负责。",[396,398,400],{"key":20,"text":397,"correct":22},"工作票",{"key":24,"text":399,"correct":26},"操作票",{"key":28,"text":401,"correct":26},"抢修票",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":20,"analysis":30},710212,"依据《中国南方电网有限责任公司电力安全工作规程》，在光纤回路进行接触激光源的工作，应采取安全防护措施，防止（ ）对眼睛造成伤害。",[406,408,410],{"key":20,"text":407,"correct":22},"激光",{"key":24,"text":409,"correct":26},"电弧",{"key":28,"text":38,"correct":26},{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":20,"analysis":30},710213,"依据《中国南方电网有限责任公司电力安全工作规程》，在继电保护、安全自动装置及自动化监控系统屏（柜）上或附近进行打眼等振动较大的工作时，应采取防止运行中设备误动作的措施，必要时向调度申请，经值班调度员或运维负责人同意，将保护（ ）。",[415,417,419],{"key":20,"text":416,"correct":22},"暂时停用",{"key":24,"text":418,"correct":26},"退出运行",{"key":28,"text":420,"correct":26},"电源断开",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":20,"analysis":30},710214,"依据《中国南方电网有限责任公司电力安全工作规程》，工作过程中，工作人员触摸插件电路时应采取可靠的（ ），防止设备损坏。",[425,427,429],{"key":20,"text":426,"correct":22},"防静电措施",{"key":24,"text":428,"correct":26},"反送电措施",{"key":28,"text":40,"correct":26},{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":20,"analysis":30},710215,"依据《中国南方电网有限责任公司电力安全工作规程》，进行石坑、冻土坑打眼或打桩时，应检查锤把、锤头及钢钎（钢桩）。扶钎人应站在打锤人（ ）。打锤人不应戴手套。钎头有开花现象时，应及时修理或更换。",[434,436,438],{"key":20,"text":435,"correct":22},"侧面",{"key":24,"text":437,"correct":26},"对面",{"key":28,"text":439,"correct":26},"后面",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":20,"analysis":30},710216,"依据《中国南方电网有限责任公司电力安全工作规程》，上横担进行工作前，应检查横担联结是否牢固和腐蚀情况，检查时（ ）应系在主杆或牢固的构件上。",[444,446,448],{"key":20,"text":445,"correct":22},"安全带",{"key":24,"text":447,"correct":26},"传递绳",{"key":28,"text":449,"correct":26},"临时拉线",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":20,"analysis":30},710217,"依据《中国南方电网有限责任公司电力安全工作规程》，在杆塔上作业时，应使用有（ ）的双背带式或全身式安全带，当后备保护绳超过3m时，应使用缓冲器。安全带和保护绳应分挂在杆塔不同部位的牢固构件上。后备保护绳不应对接使用。",[454,456,458],{"key":20,"text":455,"correct":22},"后备保护绳",{"key":24,"text":457,"correct":26},"绝缘绳",{"key":28,"text":459,"correct":26},"速差器",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":20,"analysis":30},710218,"依据《中国南方电网有限责任公司电力安全工作规程》，整体立、撤杆塔前应进行全面检查，确保各受力、连接部位全部合格方可起吊。立、撤杆塔过程中，吊件垂直下方、受力钢丝绳的（ ）禁止有人。杆塔起立离地后，应对杆塔进行冲击试验，对各受力点处作一次全面检查，确无问题，再继续起立；杆塔起立60°后应减缓速度，注意各侧拉绳。",[464,466,468],{"key":20,"text":465,"correct":22},"内角侧",{"key":24,"text":467,"correct":26},"外角侧",{"key":28,"text":469,"correct":26},"引线侧",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":20,"analysis":30},710219,"依据《中国南方电网有限责任公司电力安全工作规程》，在带电设备附近进行立撤杆时，杆塔、拉线、临时拉线与带电设备的安全距离应符合规定，且有防止立、撤杆过程中（ ）和杆塔倾斜接近带电导线的措施。",[474,476,478],{"key":20,"text":475,"correct":22},"拉线跳动",{"key":24,"text":477,"correct":26},"接地线摆动",{"key":28,"text":479,"correct":26},"引线脱落",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":20,"analysis":30},710220,"依据《中国南方电网有限责任公司电力安全工作规程》，立、撤杆应使用合格的起重设备。严禁（ ）。",[484,486,488],{"key":20,"text":485,"correct":22},"过载使用",{"key":24,"text":487,"correct":26},"接地",{"key":28,"text":489,"correct":26},"无人指挥",{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":20,"analysis":30},710221,"依据《中国南方电网有限责任公司电力安全工作规程》，顶杆及叉杆只能用于竖立（ ）以下的拔稍杆，不准用铁锹、桩柱等代用顶杆及叉杆。立杆前，应开好“马道”。作业人员要均匀地分配在电杆的两侧。",[494,496,498],{"key":20,"text":495,"correct":22},"8m",{"key":24,"text":497,"correct":26},"10m",{"key":28,"text":499,"correct":26},"15m",{"id":501,"libraryId":5,"type":15,"typeLabel":16,"stem":502,"options":503,"answer":20,"analysis":30},710222,"依据《中国南方电网有限责任公司电力安全工作规程》，使用吊车立、撤杆时，钢丝绳套应挂在电杆的适当位置以防止电杆（ ）。吊重和吊车位置应选择适当，吊钩应有可靠的防脱落装置，并应有防止吊车下沉、倾斜的措施。起、落时应注意周围环境。撤杆时，应检查无卡盘或障碍物后再试拔。",[504,506,508],{"key":20,"text":505,"correct":22},"突然倾倒",{"key":24,"text":507,"correct":26},"牵引牢固",{"key":28,"text":509,"correct":26},"地基坍塌",[511,514,517,519,522,525],{"id":512,"name":513,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":515,"name":516,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":518,"name":516,"category":7,"favorite":8},336,{"id":520,"name":521,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":523,"name":524,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":526,"name":527,"category":7,"favorite":8},353,"(N1)叉车司机"]