[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-373-10":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":608},{"id":5,"name":6,"category":7,"favorite":8},373,"电工（初级）","技能鉴定",0,10,50,872,[13,34,46,58,70,82,94,106,118,130,142,154,165,177,189,201,213,225,237,249,261,273,285,297,309,321,333,345,357,369,381,393,405,415,427,439,449,459,471,483,495,507,519,531,542,554,566,578,587,596],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},665748,1,"单选题","变压器降压使用时，能输出较大的()。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","功率",false,{"key":24,"text":25,"correct":26},"B","电流",true,{"key":28,"text":29,"correct":22},"C","电能",{"key":31,"text":32,"correct":22},"D","电压","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},665749,"6KVFS型避雷器运行中工频放电电压范围应为()KV。",[38,40,42,44],{"key":20,"text":39,"correct":22},"8~12",{"key":24,"text":41,"correct":26},"15〜21",{"key":28,"text":43,"correct":22},"16-19",{"key":31,"text":45,"correct":22},"23〜33",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},665750,"用电设备的输出功率与输入功率之比的百分数是设备的()。",[50,52,54,56],{"key":20,"text":51,"correct":22},"功率因数",{"key":24,"text":53,"correct":26},"效率",{"key":28,"text":55,"correct":22},"视在功率",{"key":31,"text":57,"correct":22},"有功功率",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},665751,"SF6断路器调整时，相间中心距离误差不大于()。",[62,64,66,68],{"key":20,"text":63,"correct":26},"5mm",{"key":24,"text":65,"correct":22},"10mm",{"key":28,"text":67,"correct":22},"12mm",{"key":31,"text":69,"correct":22},"20mm",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},665752,"若变压器的额定容量是Ps,功率因数是0$8,则其额定有功功率是（）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"Ps",{"key":24,"text":77,"correct":22},"1.25Ps",{"key":28,"text":79,"correct":26},"0.8Ps",{"key":31,"text":81,"correct":22},"0.64Ps",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":28,"analysis":33},665753,"6KV架空裸钢芯铝导线在居民区架设时，最小允许截面为()。",[86,88,90,92],{"key":20,"text":87,"correct":22},"10mm²",{"key":24,"text":89,"correct":22},"16mm²",{"key":28,"text":91,"correct":26},"25mm²",{"key":31,"text":93,"correct":22},"35mm²",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},665754,"三相对称电路中相电流超前相应线电流()。",[98,100,102,104],{"key":20,"text":99,"correct":22},"90°",{"key":24,"text":101,"correct":22},"180°",{"key":28,"text":103,"correct":22},"45°",{"key":31,"text":105,"correct":26},"30°",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},665755,"采用那种()放大电路具有倒相作用。",[110,112,114,116],{"key":20,"text":111,"correct":22},"共集电极",{"key":24,"text":113,"correct":26},"共发射极",{"key":28,"text":115,"correct":22},"共基极",{"key":31,"text":117,"correct":22},"共栅极",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},665756,"电力电缆铝芯线的连接常釆用()。",[122,124,126,128],{"key":20,"text":123,"correct":22},"插接法",{"key":24,"text":125,"correct":26},"钳压法",{"key":28,"text":127,"correct":22},"绑接法",{"key":31,"text":129,"correct":22},"焊接法",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":20,"analysis":33},665757,"电路的视在功率等于总电压与()的乘积。",[134,136,138,140],{"key":20,"text":135,"correct":26},"总电流",{"key":24,"text":137,"correct":22},"总电阻",{"key":28,"text":139,"correct":22},"总阻抗",{"key":31,"text":141,"correct":22},"总功率",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":24,"analysis":33},665758,"三相铁芯式变压器是由铁辄把三相()联在一起的三相变压器。",[146,148,150,152],{"key":20,"text":147,"correct":22},"绕组",{"key":24,"text":149,"correct":26},"铁芯",{"key":28,"text":151,"correct":22},"绕组和铁芯",{"key":31,"text":153,"correct":22},"上述说法都不对",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":20,"analysis":33},665759,"调节同步发电机的励磁机的励磁电流，则可以调节同步发电机的()。",[158,160,161,163],{"key":20,"text":159,"correct":26},"端电压",{"key":24,"text":51,"correct":22},{"key":28,"text":162,"correct":22},"转速",{"key":31,"text":164,"correct":22},"频率",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":24,"analysis":33},665760,"中性点接地，设备外壳接中性线的运行方式叫()。",[169,171,173,175],{"key":20,"text":170,"correct":22},"保护接地",{"key":24,"text":172,"correct":26},"保护接零",{"key":28,"text":174,"correct":22},"接地或接零",{"key":31,"text":176,"correct":22},"接地保护",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":31,"analysis":33},665761,"指针式万用表釆用的是()测量机构。",[181,183,185,187],{"key":20,"text":182,"correct":22},"电磁系",{"key":24,"text":184,"correct":22},"感应系",{"key":28,"text":186,"correct":22},"静电系",{"key":31,"text":188,"correct":26},"磁电系",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":31,"analysis":33},665762,"()可以签发电气设备工作票。",[193,195,197,199],{"key":20,"text":194,"correct":22},"工作负责人",{"key":24,"text":196,"correct":22},"工作许可人",{"key":28,"text":198,"correct":22},"工作人员",{"key":31,"text":200,"correct":26},"熟悉本工作规程的生产领导",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":31,"analysis":33},665763,"一般钳形电流表，不适用()电流的测量。",[205,207,209,211],{"key":20,"text":206,"correct":22},"单相交流电路",{"key":24,"text":208,"correct":22},"三相交流电路",{"key":28,"text":210,"correct":22},"高压交流二次回路",{"key":31,"text":212,"correct":26},"直流电路",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":20,"analysis":33},665764,"交直流耐压试验设备适宜放置在下列()场合。",[217,219,221,223],{"key":20,"text":218,"correct":26},"干燥",{"key":24,"text":220,"correct":22},"污染",{"key":28,"text":222,"correct":22},"腐蚀",{"key":31,"text":224,"correct":22},"强电磁场",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":24,"analysis":33},665765,"用万用表测试好的单向晶闸管时，A-G极间正反向电阻应该()。",[229,231,233,235],{"key":20,"text":230,"correct":22},"都不大",{"key":24,"text":232,"correct":26},"都很大",{"key":28,"text":234,"correct":22},"都很小",{"key":31,"text":236,"correct":22},"一小一大",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":20,"analysis":33},665766,"直流耐压试验时，当所用试验变压器只有一只引出线套管时，微安表串联接入()。",[241,243,245,247],{"key":20,"text":242,"correct":26},"高压端",{"key":24,"text":244,"correct":22},"低压端",{"key":28,"text":246,"correct":22},"高压端或低压端",{"key":31,"text":248,"correct":22},"无规定",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":20,"analysis":33},665767,"DB-45型新绝缘油，用目测检査油样时，()炭微粒和机械杂质。",[253,255,257,259],{"key":20,"text":254,"correct":26},"不应发现有",{"key":24,"text":256,"correct":22},"允许含有微量",{"key":28,"text":258,"correct":22},"允许含有一定量",{"key":31,"text":260,"correct":22},"允许含有少量",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":24,"analysis":33},665768,"三相电源绕组星形联接时对外可输出()电压。",[265,267,269,271],{"key":20,"text":266,"correct":22},"一种",{"key":24,"text":268,"correct":26},"二种",{"key":28,"text":270,"correct":22},"三种",{"key":31,"text":272,"correct":22},"四种",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":31,"analysis":33},665769,"断路器每相导电回路电阻的阻值很小，应用()方法测取。",[277,279,281,283],{"key":20,"text":278,"correct":22},"将断路器跳合几次",{"key":24,"text":280,"correct":22},"手动合闸时去掉千斤顶",{"key":28,"text":282,"correct":22},"多次复测",{"key":31,"text":284,"correct":26},"取三次分散性最小的值的平均值",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":28,"analysis":33},665770,"室外变压器的正常过负荷值不得超过其额定容量的()。",[289,291,293,295],{"key":20,"text":290,"correct":22},"10%",{"key":24,"text":292,"correct":22},"20%",{"key":28,"text":294,"correct":26},"30%",{"key":31,"text":296,"correct":22},"40%",{"id":298,"libraryId":5,"type":15,"typeLabel":16,"stem":299,"options":300,"answer":28,"analysis":33},665771,"在交流电路的功率三角形中，功率因数cosΦ=()。",[301,303,305,307],{"key":20,"text":302,"correct":22},"无功功率\u002F视在功率",{"key":24,"text":304,"correct":22},"无功功率\u002F有功功率",{"key":28,"text":306,"correct":26},"有功功率\u002F视在功率",{"key":31,"text":308,"correct":22},"视在功率\u002F无功功率",{"id":310,"libraryId":5,"type":15,"typeLabel":16,"stem":311,"options":312,"answer":31,"analysis":33},665772,"我国规定的电力系统中性点接地的方式有()种。",[313,315,317,319],{"key":20,"text":314,"correct":22},"6",{"key":24,"text":316,"correct":22},"5",{"key":28,"text":318,"correct":22},"4",{"key":31,"text":320,"correct":26},"3",{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":24,"analysis":33},665773,"三相异步电动机外壳带电，造成故障的可能原因是()。",[325,327,329,331],{"key":20,"text":326,"correct":22},"电源电压过高",{"key":24,"text":328,"correct":26},"接地不良或接地电阻太大",{"key":28,"text":330,"correct":22},"负载过重",{"key":31,"text":332,"correct":22},"电机与负载轴线不对",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":24,"analysis":33},665774,"6\u002F0.4KV电力变压器低压侧中性点应进行工作接地，其接地电阻值应不大于()。",[337,339,341,343],{"key":20,"text":338,"correct":22},"0.4Ω",{"key":24,"text":340,"correct":26},"4Ω",{"key":28,"text":342,"correct":22},"8Ω",{"key":31,"text":344,"correct":22},"10Ω",{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":24,"analysis":33},665775,"发电机并网运行时发电机电压的相序与电网电压相序要()。",[349,351,353,355],{"key":20,"text":350,"correct":22},"相反",{"key":24,"text":352,"correct":26},"相同",{"key":28,"text":354,"correct":22},"不能一致",{"key":31,"text":356,"correct":22},"无关",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":31,"analysis":33},665776,"耐压试验现场工作必须执行工作票制度，工作许可制度，工作监护制度，还有()制度。",[361,363,365,367],{"key":20,"text":362,"correct":22},"工作间断",{"key":24,"text":364,"correct":22},"工作转移",{"key":28,"text":366,"correct":22},"工作终结",{"key":31,"text":368,"correct":26},"工作间断和转移及总结",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":28,"analysis":33},665777,"某电源开路电压为220伏，短路电流为2安，则负载从电源获得的最大功率为()。",[373,375,377,379],{"key":20,"text":374,"correct":22},"120W",{"key":24,"text":376,"correct":22},"240W",{"key":28,"text":378,"correct":26},"60W",{"key":31,"text":380,"correct":22},"30W",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":24,"analysis":33},665778,"三相四线制供电线路中，若相电压为220伏，则火线与火线间电压为()。",[385,387,389,391],{"key":20,"text":386,"correct":22},"220V",{"key":24,"text":388,"correct":26},"380V",{"key":28,"text":390,"correct":22},"311V",{"key":31,"text":392,"correct":22},"440V",{"id":394,"libraryId":5,"type":15,"typeLabel":16,"stem":395,"options":396,"answer":20,"analysis":33},665779,"在以（ωt)为横轴的电流波形图中，取任一角度所对应的电流值叫该电流的()。",[397,399,401,403],{"key":20,"text":398,"correct":26},"瞬时值",{"key":24,"text":400,"correct":22},"有效值",{"key":28,"text":402,"correct":22},"平均值",{"key":31,"text":404,"correct":22},"最大值",{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":24,"analysis":33},665780,"单相桥式半控整流电路，有()组触发电压。",[409,411,413,414],{"key":20,"text":410,"correct":22},"1",{"key":24,"text":412,"correct":26},"2",{"key":28,"text":320,"correct":22},{"key":31,"text":318,"correct":22},{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":24,"analysis":33},665781,"运行中的DB-45型绝缘油的闪点应不比新油标准降低()。",[419,421,423,425],{"key":20,"text":420,"correct":22},"3℃",{"key":24,"text":422,"correct":26},"5℃",{"key":28,"text":424,"correct":22},"7℃",{"key":31,"text":426,"correct":22},"9℃",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":20,"analysis":33},665782,"测量仪表进行检验的目的是检查仪表各项技术特性，特别是()是否符合规定。",[431,433,435,437],{"key":20,"text":432,"correct":26},"准确度",{"key":24,"text":434,"correct":22},"内阻",{"key":28,"text":436,"correct":22},"工作条件",{"key":31,"text":438,"correct":22},"绝缘强度",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":31,"analysis":33},665783,"三相半控桥式整流电路的最大移相范围是()。",[443,444,446,448],{"key":20,"text":99,"correct":22},{"key":24,"text":445,"correct":22},"120°",{"key":28,"text":447,"correct":22},"150°",{"key":31,"text":101,"correct":26},{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":31,"analysis":33},665784,"已知变压器容量Ps,功率因数为0.8,则其无功功率是()。",[453,455,456,457],{"key":20,"text":454,"correct":22},"1Ps",{"key":24,"text":79,"correct":22},{"key":28,"text":77,"correct":22},{"key":31,"text":458,"correct":26},"0.6Ps",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":28,"analysis":33},665785,"功率表在电路中应釆用()接法。",[463,465,467,469],{"key":20,"text":464,"correct":22},"电流线圈发电机端接电流流入端",{"key":24,"text":466,"correct":22},"电压线圈发电机端接电流流入端",{"key":28,"text":468,"correct":26},"电压、电流线圈的发电机端都接电流流入端",{"key":31,"text":470,"correct":22},"电压、电流线圈的发电机端都接电流流出端",{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":28,"analysis":33},665786,"目前使用最广泛的接地摇表如ZC-8型，属()类型的仪表。",[475,477,479,481],{"key":20,"text":476,"correct":22},"流比计型",{"key":24,"text":478,"correct":22},"电桥型",{"key":28,"text":480,"correct":26},"电位计型",{"key":31,"text":482,"correct":22},"电压电流表型",{"id":484,"libraryId":5,"type":15,"typeLabel":16,"stem":485,"options":486,"answer":24,"analysis":33},665787,"调整高压开关的触头时，常用()的塞尺检査触头接触面的压力。",[487,489,491,493],{"key":20,"text":488,"correct":22},"0.04mmX10mm",{"key":24,"text":490,"correct":26},"0.05mmX10mm",{"key":28,"text":492,"correct":22},"0.06mmX10mm",{"key":31,"text":494,"correct":22},"随意",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":28,"analysis":33},665788,"变压器吊装所用绳索的安全系数为()。",[499,501,503,505],{"key":20,"text":500,"correct":22},"大于2",{"key":24,"text":502,"correct":22},"大于3",{"key":28,"text":504,"correct":26},"大于5〜6",{"key":31,"text":506,"correct":22},"大于7〜8",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":28,"analysis":33},665789,"电杆埋设深度最浅不应小于()m。",[511,513,515,517],{"key":20,"text":512,"correct":22},"1.0",{"key":24,"text":514,"correct":22},"1.2",{"key":28,"text":516,"correct":26},"1.5",{"key":31,"text":518,"correct":22},"1.8",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":521,"options":522,"answer":24,"analysis":33},665790,"仪器仪表的维护存放，不应釆取()措施。",[523,525,527,529],{"key":20,"text":524,"correct":22},"保持干燥",{"key":24,"text":526,"correct":26},"放在强磁场周围",{"key":28,"text":528,"correct":22},"轻拿轻放",{"key":31,"text":530,"correct":22},"棉纱擦拭",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":20,"analysis":33},665791,"室内变压器在其事故过负荷2倍时，允许持续时间为()分钟。",[535,536,538,540],{"key":20,"text":318,"correct":26},{"key":24,"text":537,"correct":22},"8",{"key":28,"text":539,"correct":22},"10",{"key":31,"text":541,"correct":22},"20",{"id":543,"libraryId":5,"type":15,"typeLabel":16,"stem":544,"options":545,"answer":20,"analysis":33},665792,"下列测量变压器变比的方法错误的是()。",[546,548,550,552],{"key":20,"text":547,"correct":26},"双臂电桥法",{"key":24,"text":549,"correct":22},"变比电桥法",{"key":28,"text":551,"correct":22},"高压测量法",{"key":31,"text":553,"correct":22},"低压测量法",{"id":555,"libraryId":5,"type":15,"typeLabel":16,"stem":556,"options":557,"answer":28,"analysis":33},665793,"高压电动机过负荷保护的动作时间应大于电动机起动时间，一般取()。",[558,560,562,564],{"key":20,"text":559,"correct":22},"4~6S",{"key":24,"text":561,"correct":22},"6〜8S",{"key":28,"text":563,"correct":26},"10〜16S",{"key":31,"text":565,"correct":22},"20〜26S",{"id":567,"libraryId":5,"type":15,"typeLabel":16,"stem":568,"options":569,"answer":28,"analysis":33},665794,"敷设电缆时，路径的选择原则是()。",[570,572,574,576],{"key":20,"text":571,"correct":22},"造价经济",{"key":24,"text":573,"correct":22},"方便施工",{"key":28,"text":575,"correct":26},"安全运行",{"key":31,"text":577,"correct":22},"前三种说法都对",{"id":579,"libraryId":5,"type":15,"typeLabel":16,"stem":580,"options":581,"answer":31,"analysis":33},665795,"有分路电阻阀型避雷器规程规定电导电流相差值不应大于()。",[582,583,584,585],{"key":20,"text":290,"correct":22},{"key":24,"text":292,"correct":22},{"key":28,"text":294,"correct":22},{"key":31,"text":586,"correct":26},"50%",{"id":588,"libraryId":5,"type":15,"typeLabel":16,"stem":589,"options":590,"answer":28,"analysis":33},665796,"中性点不接地，而设备外壳接地的形式叫()。",[591,592,593,594],{"key":20,"text":172,"correct":22},{"key":24,"text":170,"correct":22},{"key":28,"text":174,"correct":26},{"key":31,"text":595,"correct":22},"不确定",{"id":597,"libraryId":5,"type":15,"typeLabel":16,"stem":598,"options":599,"answer":24,"analysis":33},665797,"对电缆进行直流耐压试验时，其优点之一是避免()对良好绝缘起永久性破坏作用。",[600,602,604,606],{"key":20,"text":601,"correct":22},"直流电压",{"key":24,"text":603,"correct":26},"交流低压",{"key":28,"text":605,"correct":22},"交流高压",{"key":31,"text":607,"correct":22},"交流电流",[609,612,615,618,621,624],{"id":610,"name":611,"category":7,"favorite":8},338,"保育员",{"id":613,"name":614,"category":7,"favorite":8},339,"保育员（初级）",{"id":616,"name":617,"category":7,"favorite":8},341,"保育员（中级）",{"id":619,"name":620,"category":7,"favorite":8},342,"保育员（高级）",{"id":622,"name":623,"category":7,"favorite":8},344,"茶艺师",{"id":625,"name":626,"category":7,"favorite":8},345,"茶艺师（初级）"]