[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-308-26":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":322},{"id":5,"name":6,"category":7,"favorite":8},308,"煤矿主要负责人","安全生产",0,26,50,2104,[13,28,34,40,46,52,58,64,70,76,82,88,94,100,106,112,118,124,130,136,142,148,154,160,166,172,178,184,190,196,202,208,214,220,226,232,238,244,250,256,262,268,274,280,286,292,298,304,310,316],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":25,"analysis":27},608410,3,"判断题","井下储存4吨工业炸药的库房是重大危险源。",[19,23],{"key":20,"text":21,"correct":22},"A","正确",false,{"key":24,"text":25,"correct":26},"B","错误",true,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":21,"analysis":27},608411,"应急救授预案中应考虑在各主要工作岗位安排有实践经验、掌握急救知识和救护技术的人担任急救员。",[32,33],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":25,"analysis":27},608412,"应急救援预案只传达贯彻到班组长以上的管理人员。",[38,39],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":21,"analysis":27},608413,"应急救援预案是指政府和企业为减少事故后果而预先制定的抢险救灾方案，是进行事故救援活动的行动指南。",[44,45],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":21,"analysis":27},608414,"应急救授预案是针对重大危险源制定的。专项预案应该是包括各种自然灾害及大面积传染病的预案。",[50,51],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":21,"analysis":27},608415,"在煤矿井下，非专职人员或非值班电气人员不得擅自操作电气设备。",[56,57],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":21,"analysis":27},608416,"对井下各水平中央变(配)电所、主排水泵房和下山开采的采区排水泵房供电的线蹄，不得少于两回路。当任一回路停止供电时，其余回路应能担负全部负荷。",[62,63],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":21,"analysis":27},608417,"在机械提升的进风的倾斜井巷(不包括输送机上、下山)和使用木支架的立井井筒中敷设电缆时，必须有可靠的安全措施。",[68,69],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":21,"analysis":27},608418,"列车通过的风门，必须设有当列车通过时能够发出在风门两侧都能接收到声光信号的装置。",[74,75],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":21,"analysis":27},608419,"立井井筒中所用的电缆中间不得有接头；因井筒太深需设接头时，应将接头设在中间水平巷道内。",[80,81],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":25,"analysis":27},608420,"在总回风巷和专用回风巷中可以敷设电缆。",[86,87],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":21,"analysis":27},608421,"每一提升装置，必须装有从井底信号工发给井口信号工和从井口信号工发给绞车司机的信号装置。",[92,93],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":21,"analysis":27},608422,"井下蓄电池充电室内必须采用矿用防爆型电气设备。测定电压时，可使用普通型电压表，但必须在揭开电池盖10min以后进行。",[98,99],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":21,"analysis":27},608423,"保护接地可有效防止因设备外壳带电引起的人身触电事故。",[104,105],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":25,"analysis":27},608424,"在煤矿井下36V及以上电气设备必须设保护接地。",[110,111],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":25,"analysis":27},608425,"集中性漏电是因淋水、潮湿导致电网中某段线路或某些设备绝缘下降至危险值而形成的漏电。",[116,117],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":21,"analysis":27},608426,"设置过电流保护的目的，就是当线路或电气设备发生过电流故障时，能及时切断电源，防止过电流故障引发电气火灾或烧毁设备。",[122,123],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":25,"analysis":27},608427,"在有瓦斯、煤尘爆炸危险的井下场所，电气短路不会引起瓦斯、煤尘爆炸。",[128,129],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":21,"analysis":27},608428,"矿用电气设备的失爆主要是由于安装、检修质量不符合标准及使用、维护不当造成的。",[134,135],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":21,"analysis":27},608429,"井下高压电气设备的修理和调整工作，应有工作票和施工措施。",[140,141],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":25,"analysis":27},608430,"井下电气设备的检查、维护和调整，必须由采区电钳工进行。",[146,147],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":25,"analysis":27},608431,"防爆性能遭受破坏的电气设备，在保证安全的前提下，可以继续使用。",[152,153],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":21,"analysis":27},608432,"井下防爆电气设备的运行、维护和修理，必须符合防爆性能的各项技术要求。",[158,159],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":21,"analysis":27},608433,"矿用橡套电缆的接地芯线，除用作监测接地回路外，不得兼作他用。",[164,165],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":21,"analysis":27},608434,"所有电气设备的保护接地装置(包括电缆的铠装、铅皮、接地芯线)和局部接地装置，应与主接地极连接成1个总接地网。",[170,171],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":25,"analysis":27},608435,"井下巷道内的电缆，不同型电缆之间可以直接连接。",[176,177],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":21,"analysis":27},608436,"在有瓦斯抽放管路的巷道内，电缆(包括通信、信号电缆)必须与瓦斯抽放管路分挂在巷道两侧。",[182,183],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":21,"analysis":27},608437,"井下用电缆不应悬挂在风管或水管上，不得遭受淋水。",[188,189],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":21,"analysis":27},608438,"井下溜放煤、矸、材料的溜道中严禁敷设电缆。",[194,195],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":21,"analysis":27},608439,"井下机电设备硐室内必须设置足够数量的扑灭电气火灾的灭火器材。",[200,201],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":21,"analysis":27},608440,"通信线路必须在人井处装设熔断器和防雷电装置。",[206,207],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":21,"analysis":27},608441,"经由地面架空线路引入井下的供电线路和电机车架线，必须在入井处装设防雷电装置。",[212,213],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":25,"analysis":27},608442,"直接向井下供电的高压馈电线上，应装设自动重合闸。",[218,219],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":21,"analysis":27},608443,"井下低压馈电线上，必须装设检漏保护装置或有选择性的漏电保护装置，保证自动切断漏电的馈电线路。",[224,225],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":21,"analysis":27},608444,"井下供移动变电站的高压馈电线上，必须装设有选择性的动作于跳闸的单相接地保护装置。",[230,231],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":21,"analysis":27},608445,"井下低压电动机的控制设备，应具备短路、过负荷、单相断线、漏电闭锁保护装置及远程控制装置。",[236,237],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":21,"analysis":27},608446,"井下由采区变电所、移动变电站或配电点引出的馈电线上，应装设短路、过负荷和漏电保护装置。",[242,243],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":21,"analysis":27},608447,"井下高压电动机、动力变压器的高压控制设备，应具有短路、过负荷、接地和欠压释放保护。",[248,249],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":25,"analysis":27},608448,"煤矿井下硐室外可以使用油浸式低压电气设备。",[254,255],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":21,"analysis":27},608449,"井下防爆电气设备变更额定值使用和进行技术改造时，必须经国家授权的矿用产品质量监督检验部门检验合格后，方可投入运行。",[260,261],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":21,"analysis":27},608450,"井下电缆应带有供保护接地用的足够截面的导体。",[266,267],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":21,"analysis":27},608451,"在煤矿井下，容易碰到的、裸露的带电体及机械外露的转动和传动部分必须加装护罩或遮栏等防护设施。",[272,273],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":21,"analysis":27},608452,"煤(岩)与瓦斯(二氧化碳)突出矿井的井底车场的主泵房内，可使用矿用增安型电动机。",[278,279],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":25,"analysis":27},608453,"瓦斯矿井总回风巷、主要回风巷、采区回风巷、工作面和工作面进回风巷可选用矿用防爆型电气设备和矿用一般型电气设备。",[284,285],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":21,"analysis":27},608454,"10kV及其以下的矿井架空电源线路不得共杆架设。",[290,291],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":25,"analysis":27},608455,"矿井的两回路电源线路上可以分接其他负荷。",[296,297],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":21,"analysis":27},608456,"装设保护接地可防止设备或电缆漏电引起的人身触电事故。",[302,303],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":21,"analysis":27},608457,"煤矿井下无人值班的变电硐室必须关门加锁，并有值班人员巡回检查。",[308,309],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":25,"analysis":27},608458,"漏电电流不会引起瓦斯、煤尘爆炸。",[314,315],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":21,"analysis":27},608459,"电网过电流是引起电气火灾的主要原因之一。",[320,321],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},[323,326,329,332,335,338],{"id":324,"name":325,"category":7,"favorite":8},22,"安全管理人员",{"id":327,"name":328,"category":7,"favorite":8},23,"海洋石油天然气开采",{"id":330,"name":331,"category":7,"favorite":8},258,"金属非金属-地下矿山",{"id":333,"name":334,"category":7,"favorite":8},259,"金属非金属-露天矿山",{"id":336,"name":337,"category":7,"favorite":8},260,"金属非金属-小型露天采石场",{"id":339,"name":340,"category":7,"favorite":8},261,"金属冶炼(黑色金属铸造)"]