[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-308-2":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":495},{"id":5,"name":6,"category":7,"favorite":8},308,"煤矿主要负责人","安全生产",0,2,50,2104,[13,31,41,51,61,71,81,91,101,111,121,131,141,151,161,171,181,191,201,211,221,230,240,250,260,270,280,290,300,307,314,323,333,341,351,361,368,375,385,395,405,415,425,434,443,453,461,468,478,485],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":30},607165,1,"单选题","对煤矿井下发生重伤事故时，在场人员对受伤者应立即( )。",[19,23,27],{"key":20,"text":21,"correct":22},"A","就地抢救",true,{"key":24,"text":25,"correct":26},"B","。送出地面",false,{"key":28,"text":29,"correct":26},"C","打急救电话","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":28,"analysis":30},607166,"在煤矿井下生产过程中，如发生人员骨折，其他人员应采用( )的急救原则。",[35,37,39],{"key":20,"text":36,"correct":26},"等待救护人员到来",{"key":24,"text":38,"correct":26},"立即送往医院",{"key":28,"text":40,"correct":22},"先固定后搬运",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":28,"analysis":30},607167,"火区封闭后，现场人员应立即撤出危险区。进入检查或加固密闭墙，应在( )之后进行。",[45,47,49],{"key":20,"text":46,"correct":26},"24min",{"key":24,"text":48,"correct":26},"48h",{"key":28,"text":50,"correct":22},"24h",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":24,"analysis":30},607168,"电石或乙炔着火时，严禁用( )扑救。",[55,57,59],{"key":20,"text":56,"correct":26},"二氧化碳灭火器",{"key":24,"text":58,"correct":22},"四氯化碳灭火器",{"key":28,"text":60,"correct":26},"干砂",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":20,"analysis":30},607169,"若火灾发生在上山独头巷道中段时，( )。",[65,67,69],{"key":20,"text":66,"correct":22},"不得直接灭火",{"key":24,"text":68,"correct":26},"可以直接灭火",{"key":28,"text":70,"correct":26},"是否直接灭火由队长决定",{"id":72,"libraryId":5,"type":15,"typeLabel":16,"stem":73,"options":74,"answer":28,"analysis":30},607170,"从预防自燃火灾的角度出发，对通风系统的要求是通风压差小、( )。",[75,77,79],{"key":20,"text":76,"correct":26},"风速大",{"key":24,"text":78,"correct":26},"风量大",{"key":28,"text":80,"correct":22},"漏风少",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":20,"analysis":30},607171,"爆炸产生火灾，应( )，并应采取防止再次发生爆炸的措施。",[85,87,89],{"key":20,"text":86,"correct":22},"同时灭火和救人",{"key":24,"text":88,"correct":26},"先灭火后救人",{"key":28,"text":90,"correct":26},"先救人后灭火",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":20,"analysis":30},607172,"独头巷道发生火灾，进行救援时的首选通风方法是( )。",[95,97,99],{"key":20,"text":96,"correct":22},"维持局部通风机原状",{"key":24,"text":98,"correct":26},"开启局部通风机",{"key":28,"text":100,"correct":26},"停止局部通风机",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":28,"analysis":30},607173,"矿井火灾标志气体中最常用的是( )。",[105,107,109],{"key":20,"text":106,"correct":26},"C₂H₂",{"key":24,"text":108,"correct":26},"C₂H₄",{"key":28,"text":110,"correct":22},"CO",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":24,"analysis":30},607174,"侦察时应首先把侦察小队派往( )的地点。",[115,117,119],{"key":20,"text":116,"correct":26},"破坏最严重",{"key":24,"text":118,"correct":22},"遇险人员最多",{"key":28,"text":120,"correct":26},"遇难人员最多",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":20,"analysis":30},607175,"立井井筒与各水平车场的连接处，必须设有专用的( )，严禁人员通过提升间。",[125,127,129],{"key":20,"text":126,"correct":22},"人行道",{"key":24,"text":128,"correct":26},"躲避硐",{"key":28,"text":130,"correct":26},"运物车",{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":28,"analysis":30},607176,"重大事故应急救援体系应实行分级响应机制，其中三级响应级别是指( )。",[135,137,139],{"key":20,"text":136,"correct":26},"需要多个政府部门协作解决的",{"key":24,"text":138,"correct":26},"需要国家的力量解决的",{"key":28,"text":140,"correct":22},"必须利用一个城市所有部门的力量解决的",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":20,"analysis":30},607177,"煤矿安全监控设备必须定期进行调试、校正，每月至少( )次。便携式甲烷检测报警仪，每7天必须使用校准气样和空气样调校1次。",[145,147,149],{"key":20,"text":146,"correct":22},"1",{"key":24,"text":148,"correct":26},"2",{"key":28,"text":150,"correct":26},"3",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":24,"analysis":30},607178,"独头掘进水平巷道发生火灾时，最难处理的是( )。",[155,157,159],{"key":20,"text":156,"correct":26},"迎头火灾",{"key":24,"text":158,"correct":22},"中部火灾",{"key":28,"text":160,"correct":26},"入口火灾",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":20,"analysis":30},607179,"发生在上行风流中的火灾，产生的火风压会使火源所在巷道风量( )。",[165,167,169],{"key":20,"text":166,"correct":22},"增加",{"key":24,"text":168,"correct":26},"减小",{"key":28,"text":170,"correct":26},"不变",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":28,"analysis":30},607180,"全矿井停电恢复供电后，应首先启动( )。",[175,177,179],{"key":20,"text":176,"correct":26},"主要水泵",{"key":24,"text":178,"correct":26},"副井提升",{"key":28,"text":180,"correct":22},"主要通风机",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":28,"analysis":30},607181,"发生煤与瓦斯突出事故后，应该( )。",[185,187,189],{"key":20,"text":186,"correct":26},"停风",{"key":24,"text":188,"correct":26},"反风",{"key":28,"text":190,"correct":22},"保持或立即恢复正常通风",{"id":192,"libraryId":5,"type":15,"typeLabel":16,"stem":193,"options":194,"answer":24,"analysis":30},607182,"掘进工作面迎头由于爆破发生火灾后，应( )。",[195,197,199],{"key":20,"text":196,"correct":26},"立即关闭局部通风机",{"key":24,"text":198,"correct":22},"立即切断附近设备电源进行洒水灭火",{"key":28,"text":200,"correct":26},"撤出所有人员",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":24,"analysis":30},607183,"在有两个回风井的矿井中，两个回风井是一大一小两种主要通风机，则该矿井反风时大小风机的启动顺序是( )。",[205,207,209],{"key":20,"text":206,"correct":26},"先大后小",{"key":24,"text":208,"correct":22},"先小后大",{"key":28,"text":210,"correct":26},"同时启动",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":28,"analysis":30},607184,"发生煤与瓦斯突出事故后，撤出灾区和( )的人员是抢险救灾的首要任务。",[215,217,219],{"key":20,"text":216,"correct":26},"进风流",{"key":24,"text":218,"correct":26},"回风流",{"key":28,"text":220,"correct":22},"受威胁区",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":20,"analysis":30},607185,"处理掘进巷道火灾时，( )的控制是关键。",[225,227,228],{"key":20,"text":226,"correct":22},"局部通风机",{"key":24,"text":180,"correct":26},{"key":28,"text":229,"correct":26},"火势",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":28,"analysis":30},607186,"重大灾害事故的共性之一是具有( )。",[234,236,238],{"key":20,"text":235,"correct":26},"可预见性",{"key":24,"text":237,"correct":26},"临时性",{"key":28,"text":239,"correct":22},"继发性",{"id":241,"libraryId":5,"type":15,"typeLabel":16,"stem":242,"options":243,"answer":24,"analysis":30},607187,"发生煤与瓦斯突出事故后，指挥人员应派人到进、回风井口及其( )m范围内检查瓦斯，设置警戒，熄灭警戒内的一切火源，严禁机动车辆进入警戒区。",[244,246,248],{"key":20,"text":245,"correct":26},"40",{"key":24,"text":247,"correct":22},"50",{"key":28,"text":249,"correct":26},"60",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":20,"analysis":30},607188,"处理煤尘爆炸的首要问题是( )。",[254,256,258],{"key":20,"text":255,"correct":22},"防止二次爆炸",{"key":24,"text":257,"correct":26},"防止火灾事故",{"key":28,"text":259,"correct":26},"防止引起瓦斯爆炸",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":20,"analysis":30},607189,"火势较大的明火火灾的处理关键是( )。",[264,266,268],{"key":20,"text":265,"correct":22},"正确调动风流",{"key":24,"text":267,"correct":26},"高强度灭火",{"key":28,"text":269,"correct":26},"封闭巷道",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":24,"analysis":30},607190,"在变压器中性点不接地系统中，将电气设备正常情况下不带电的金属外壳及构架等与大地作良好的电气连接称为( )接地。",[274,276,278],{"key":20,"text":275,"correct":26},"绝缘",{"key":24,"text":277,"correct":22},"保护",{"key":28,"text":279,"correct":26},"工作",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":20,"analysis":30},607191,"( )是指当电力网路中漏电电流达到危险值时，能自动切断电源的装置。",[284,286,288],{"key":20,"text":285,"correct":22},"检漏装置",{"key":24,"text":287,"correct":26},"接地装置",{"key":28,"text":289,"correct":26},"过流保护装置",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":20,"analysis":30},607192,"井下保护接地网接地电阻值测定，应每( )1次。",[294,296,298],{"key":20,"text":295,"correct":22},"季",{"key":24,"text":297,"correct":26},"6个月",{"key":28,"text":299,"correct":26},"年",{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":20,"analysis":30},607193,"井下固定敷设电缆的绝缘和外部检查，应每( )1次。",[304,305,306],{"key":20,"text":295,"correct":22},{"key":24,"text":297,"correct":26},{"key":28,"text":299,"correct":26},{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":28,"analysis":30},607194,"井下高压电缆的泄漏和耐压试验，应每( )1次。",[311,312,313],{"key":20,"text":295,"correct":26},{"key":24,"text":297,"correct":26},{"key":28,"text":299,"correct":22},{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":28,"analysis":30},607195,"井下配电系统继电保护装置整定检查，应每( )1次。",[318,320,322],{"key":20,"text":319,"correct":26},"月",{"key":24,"text":321,"correct":26},"3个月",{"key":28,"text":297,"correct":22},{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":24,"analysis":30},607196,"井下使用中的防爆电气设备的防爆性能检查，应( )1次。",[327,329,331],{"key":20,"text":328,"correct":26},"每周",{"key":24,"text":330,"correct":22},"每月",{"key":28,"text":332,"correct":26},"每季",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":24,"analysis":30},607197,"井下低压配电点或装有( )台以上电气设备的地点应装设局部接地极。",[337,338,339],{"key":20,"text":148,"correct":26},{"key":24,"text":150,"correct":22},{"key":28,"text":340,"correct":26},"4",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":24,"analysis":30},607198,"井下电气设备保护接地的主接地极应用耐腐蚀的钢板制成，其面积不得小于( )m、厚度不得小于5mm。",[345,347,349],{"key":20,"text":346,"correct":26},"0.5",{"key":24,"text":348,"correct":22},"0.75",{"key":28,"text":350,"correct":26},"0.8",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":24,"analysis":30},607199,"井下电气设备保护接地的主接地极应在( )各埋设1块。",[355,357,359],{"key":20,"text":356,"correct":26},"水仓、水沟中",{"key":24,"text":358,"correct":22},"主、副水仓中",{"key":28,"text":360,"correct":26},"水沟、潮湿处",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":20,"analysis":30},607200,"井下每一移动式和手持式电气设备至局部接地极之间的保护接地用的电缆芯线和接地连接导线的电阻值，不得超过( )Ω。",[365,366,367],{"key":20,"text":146,"correct":22},{"key":24,"text":148,"correct":26},{"key":28,"text":150,"correct":26},{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":24,"analysis":30},607201,"井下接地网上任一保护接地点的接地电阻值不应超过( )Ω。",[372,373,374],{"key":20,"text":146,"correct":26},{"key":24,"text":148,"correct":22},{"key":28,"text":150,"correct":26},{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":24,"analysis":30},607202,"井下电气设备，电压在( )V以上和由于绝缘损坏可能带有危险电压的电气设备的金属外壳、构架，铠装电缆的钢带(或钢丝)、铅皮或屏蔽护套等必须有保护接地。",[379,381,383],{"key":20,"text":380,"correct":26},"24",{"key":24,"text":382,"correct":22},"36",{"key":28,"text":384,"correct":26},"42",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":20,"analysis":30},607203,"井下照明和信号装置，应采用具有短路、过载和( )保护的照明信号综合保护装置配电。",[389,391,393],{"key":20,"text":390,"correct":22},"漏电",{"key":24,"text":392,"correct":26},"欠压",{"key":28,"text":394,"correct":26},"过压",{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":397,"options":398,"answer":28,"analysis":30},607204,"矿井中的电气信号，除信号集中闭塞外应能( )发声和发光。",[399,401,403],{"key":20,"text":400,"correct":26},"连续",{"key":24,"text":402,"correct":26},"交替",{"key":28,"text":404,"correct":22},"同时",{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":24,"analysis":30},607205,"井下防爆型的通信、信号和控制等装置，应优先采用( )型。",[409,411,413],{"key":20,"text":410,"correct":26},"隔爆",{"key":24,"text":412,"correct":22},"本质安全",{"key":28,"text":414,"correct":26},"防爆特殊",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":28,"analysis":30},607206,"矿灯的管理和使用要求，发出的矿灯，最低应能连续正常使用( )h。",[419,421,423],{"key":20,"text":420,"correct":26},"8",{"key":24,"text":422,"correct":26},"10",{"key":28,"text":424,"correct":22},"11",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":20,"analysis":30},607207,"井下电缆与压风管、供水管在巷道同一侧敷设时，必须敷设在管子上方，并保持( )m以上的距离。",[429,431,433],{"key":20,"text":430,"correct":22},"0.3",{"key":24,"text":432,"correct":26},"0.4",{"key":28,"text":346,"correct":26},{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":20,"analysis":30},607208,"井下电缆悬挂点的间距，在水平巷道或倾斜井巷内不得超过( )m，在立井井筒内不得超过6m。",[438,439,441],{"key":20,"text":150,"correct":22},{"key":24,"text":440,"correct":26},"5",{"key":28,"text":442,"correct":26},"7",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":28,"analysis":30},607209,"在水平巷道或倾角在( )以下的井巷中，电缆应用吊钩悬挂。",[447,449,451],{"key":20,"text":448,"correct":26},"10°",{"key":24,"text":450,"correct":26},"20°",{"key":28,"text":452,"correct":22},"30°",{"id":454,"libraryId":5,"type":15,"typeLabel":16,"stem":455,"options":456,"answer":24,"analysis":30},607210,"井下变电硐室长度超过( )m时，必须在硐室的两端各设1个出口。",[457,458,460],{"key":20,"text":440,"correct":26},{"key":24,"text":459,"correct":22},"6",{"key":28,"text":422,"correct":26},{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":24,"analysis":30},607211,"从井下机电设备硐室出口防火铁门起( )m内的巷道，应砌碹或用其他不燃性材料支护。",[465,466,467],{"key":20,"text":422,"correct":26},{"key":24,"text":440,"correct":22},{"key":28,"text":459,"correct":26},{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":24,"analysis":30},607212,"在煤矿井下，每班使用前，必须对煤电钻综合保护装置进行1次( )试验。",[472,474,476],{"key":20,"text":473,"correct":26},"合闸",{"key":24,"text":475,"correct":22},"跳闸",{"key":28,"text":477,"correct":26},"运行",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":20,"analysis":30},607213,"在煤矿井下，每天必须对低压检漏装置的运行情况进行( )次跳闸试验。",[482,483,484],{"key":20,"text":146,"correct":22},{"key":24,"text":148,"correct":26},{"key":28,"text":150,"correct":26},{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":28,"analysis":30},607214,"地面变电所和井下中央变电所的高压馈电线上，必须装设( )的单相接地保护装置。",[489,491,493],{"key":20,"text":490,"correct":26},"有漏电闭锁",{"key":24,"text":492,"correct":26},"有漏电保护",{"key":28,"text":494,"correct":22},"有选择性",[496,499,502,505,508,511],{"id":497,"name":498,"category":7,"favorite":8},22,"安全管理人员",{"id":500,"name":501,"category":7,"favorite":8},23,"海洋石油天然气开采",{"id":503,"name":504,"category":7,"favorite":8},258,"金属非金属-地下矿山",{"id":506,"name":507,"category":7,"favorite":8},259,"金属非金属-露天矿山",{"id":509,"name":510,"category":7,"favorite":8},260,"金属非金属-小型露天采石场",{"id":512,"name":513,"category":7,"favorite":8},261,"金属冶炼(黑色金属铸造)"]