[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-303-4":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":528},{"id":5,"name":6,"category":7,"favorite":8},303,"煤矿井下电气作业","安全生产",0,4,50,567,[13,31,41,51,61,71,81,91,101,111,121,131,144,154,163,173,183,195,205,217,227,237,247,257,267,279,289,299,309,319,329,339,350,360,370,382,392,402,412,422,432,442,452,462,469,479,488,498,508,518],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":30},604404,1,"单选题","采掘工作面及其他作业地点风流中,电动机或开关安设地点附近()以内风流中的瓦斯浓度达到()时,必须停止工作,切断电源,撤出人员,进行处理。",[19,23,27],{"key":20,"text":21,"correct":22},"A","20m,1.5%",true,{"key":24,"text":25,"correct":26},"B","10m,1.5%",false,{"key":28,"text":29,"correct":26},"C","20m,1.0%","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":28,"analysis":30},604405,"使用刨煤机采煤时,工作面至少每隔()应装设能随时停止刨头和刮板输送机的装置,或装设向刨煤机司机发送信号的装置。",[35,37,39],{"key":20,"text":36,"correct":26},"40m",{"key":24,"text":38,"correct":26},"35m",{"key":28,"text":40,"correct":22},"30m",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":28,"analysis":30},604406,"煤电钻综合保护装置安装时,应可靠接地,辅助接地应在主接地()以外处。",[45,47,49],{"key":20,"text":46,"correct":26},"3m",{"key":24,"text":48,"correct":26},"4m",{"key":28,"text":50,"correct":22},"5m",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":20,"analysis":30},604407,"过电流是指流过电气设备和电缆的电流()额定值。",[55,57,59],{"key":20,"text":56,"correct":22},"超过",{"key":24,"text":58,"correct":26},"等于",{"key":28,"text":60,"correct":26},"小于",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":20,"analysis":30},604408,"隔爆电气设备隔爆接合面的表面粗糙度不大于()。",[65,67,69],{"key":20,"text":66,"correct":22},"6.3μm",{"key":24,"text":68,"correct":26},"12.5μm",{"key":28,"text":70,"correct":26},"3.2μm",{"id":72,"libraryId":5,"type":15,"typeLabel":16,"stem":73,"options":74,"answer":20,"analysis":30},604409,"设置在水沟中的()接地极应用面积不小于0.6m2、厚度不小于3mm的钢板制成.",[75,77,79],{"key":20,"text":76,"correct":22},"局部",{"key":24,"text":78,"correct":26},"主",{"key":28,"text":80,"correct":26},"辅助",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":24,"analysis":30},604410,"每()必须对漏电继电器进行1次详细的检查和修理。",[85,87,89],{"key":20,"text":86,"correct":26},"日",{"key":24,"text":88,"correct":22},"月",{"key":28,"text":90,"correct":26},"周",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":20,"analysis":30},604411,"接地网上任一保护接地点的接地电阻值不得超过()。",[95,97,99],{"key":20,"text":96,"correct":22},"2Ω",{"key":24,"text":98,"correct":26},"1Ω",{"key":28,"text":100,"correct":26},"3Ω",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":20,"analysis":30},604412,"井下由采区变电所引出的馈电线上,应装设()。",[105,107,109],{"key":20,"text":106,"correct":22},"短路、过负荷、漏电保护装置",{"key":24,"text":108,"correct":26},"短路、过负荷、接地和欠压释放保护",{"key":28,"text":110,"correct":26},"短路、过负荷、单相断线、漏电闭锁保护装置及远程控制装置",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":20,"analysis":30},604413,"过负荷是指电气设备的实际电流值超过了该电气设备的()值,并超过允许过负荷时间。",[115,117,119],{"key":20,"text":116,"correct":22},"额定电流",{"key":24,"text":118,"correct":26},"启动电流",{"key":28,"text":120,"correct":26},"最高电流",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":28,"analysis":30},604414,"硐室入口处必须悬挂（）警示牌。",[125,127,129],{"key":20,"text":126,"correct":26},"有电危险",{"key":24,"text":128,"correct":26},"闲人免进",{"key":28,"text":130,"correct":22},"非工作人员禁止入内",{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":24,"analysis":30},604415,"对井下各水平中央变（配）电所、和采（盘）区变（配）电所、主排水泵房和下山开采的采区排水泵房供电线路，不得少于两回路。其供电线路应来自各自的变压器或母线段，线路上（ ）分接任何负荷。",[135,137,139,141],{"key":20,"text":136,"correct":26},"可以",{"key":24,"text":138,"correct":22},"不应",{"key":28,"text":140,"correct":26},"除照明负荷外不应",{"key":142,"text":143,"correct":26},"D","经批准可以",{"id":145,"libraryId":5,"type":15,"typeLabel":16,"stem":146,"options":147,"answer":20,"analysis":30},604416,"每一移动式和手持式电气设备至局部接地极之间保护接地用的电缆芯线和接地连接导线的电阻值,不得超过()。",[148,150,152],{"key":20,"text":149,"correct":22},"1.0Ω",{"key":24,"text":151,"correct":26},"1.5Ω",{"key":28,"text":153,"correct":26},"2.0Ω",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":24,"analysis":30},604417,"()由地面中性点直接接地的变压器或发电机直接向井下供电。",[158,159,161],{"key":20,"text":136,"correct":26},{"key":24,"text":160,"correct":22},"严禁",{"key":28,"text":162,"correct":26},"必要时可以",{"id":164,"libraryId":5,"type":15,"typeLabel":16,"stem":165,"options":166,"answer":24,"analysis":30},604418,"井下隔爆电气设备(如异步电动机)对地绝缘电阻和相间绝缘电阻应不小于()。",[167,169,171],{"key":20,"text":168,"correct":26},"3MΩ",{"key":24,"text":170,"correct":22},"5MΩ",{"key":28,"text":172,"correct":26},"4MΩ",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":28,"analysis":30},604419,"使用刨煤机采煤,工作面倾角在()以上时,与之配套的刮板输送机必须装设防滑、锚固装置。",[177,179,181],{"key":20,"text":178,"correct":26},"20°",{"key":24,"text":180,"correct":26},"15°",{"key":28,"text":182,"correct":22},"12°",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":24,"analysis":30},604420,"井下防爆型的通信、信号和控制装置,应优先采用()。",[187,189,191,193],{"key":20,"text":188,"correct":26},"增安型",{"key":24,"text":190,"correct":22},"本质安全型",{"key":28,"text":192,"correct":26},"特殊型",{"key":142,"text":194,"correct":26},"隔爆型",{"id":196,"libraryId":5,"type":15,"typeLabel":16,"stem":197,"options":198,"answer":28,"analysis":30},604421,"使用局部通风机的地点,必须实现()闭锁。",[199,201,203],{"key":20,"text":200,"correct":26},"甲烷电",{"key":24,"text":202,"correct":26},"瓦斯电",{"key":28,"text":204,"correct":22},"风电",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":28,"analysis":30},604422,"电气设备使用的绝缘油的物理、化学性能检测和电气耐压试验,()应进行1次试验。",[209,211,213,215],{"key":20,"text":210,"correct":26},"每3年",{"key":24,"text":212,"correct":26},"每季",{"key":28,"text":214,"correct":22},"每年",{"key":142,"text":216,"correct":26},"每半年",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":24,"analysis":30},604423,"低压隔爆开关的触头(铜触头)磨损至原厚度的()、超行程压力低于规定值时,应更换触头。",[221,223,225],{"key":20,"text":222,"correct":26},"1\u002F2",{"key":24,"text":224,"correct":22},"1\u002F3",{"key":28,"text":226,"correct":26},"1\u002F4",{"id":228,"libraryId":5,"type":15,"typeLabel":16,"stem":229,"options":230,"answer":28,"analysis":30},604424,"井下搬迁、检修电气设备前,必须切断电源,检查瓦斯,在其巷道风流中瓦斯浓度低于()时方可验电。",[231,233,235],{"key":20,"text":232,"correct":26},"0.5%",{"key":24,"text":234,"correct":26},"1.5%",{"key":28,"text":236,"correct":22},"1.0%",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":28,"analysis":30},604425,"风电闭锁是风机停转时,()电源也同时被切断。",[241,243,245],{"key":20,"text":242,"correct":26},"风机",{"key":24,"text":244,"correct":26},"所有",{"key":28,"text":246,"correct":22},"掘进工作面动力",{"id":248,"libraryId":5,"type":15,"typeLabel":16,"stem":249,"options":250,"answer":24,"analysis":30},604426,"高低压电力电缆敷设在巷道同一侧时,高低压电缆之间的距离应大于()。",[251,253,255],{"key":20,"text":252,"correct":26},"0.3m",{"key":24,"text":254,"correct":22},"0.1m",{"key":28,"text":256,"correct":26},"0.2m",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":20,"analysis":30},604427,"电源电压在1140V以上的插接装置,若()电气联锁装置,可以定为失爆。",[261,263,265],{"key":20,"text":262,"correct":22},"没有",{"key":24,"text":264,"correct":26},"有",{"key":28,"text":266,"correct":26},"有与无",{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":20,"analysis":30},604428,"自轨面算起电机车架空线的悬挂高度,在井底车场内,从井底到乘车场不小于()。",[271,273,275,277],{"key":20,"text":272,"correct":22},"2.2m",{"key":24,"text":274,"correct":26},"2.0m",{"key":28,"text":276,"correct":26},"1.0m",{"key":142,"text":278,"correct":26},"3.0m",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":24,"analysis":30},604429,"定期检查电缆和电气设备的绝缘,并按规定做()试验。",[283,285,287],{"key":20,"text":284,"correct":26},"阶段性",{"key":24,"text":286,"correct":22},"预防性",{"key":28,"text":288,"correct":26},"现场",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":28,"analysis":30},604430,"煤矿使用的涉及安全生产的产品,必须经过安全检验并取得煤矿矿用产品()。",[293,295,297],{"key":20,"text":294,"correct":26},"防爆标志",{"key":24,"text":296,"correct":26},"入井合格证",{"key":28,"text":298,"correct":22},"安全标志",{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":24,"analysis":30},604431,"转盖式或插盖式隔爆接合面的宽度小于()、间隙大于0.5mm以上为失爆。",[303,305,307],{"key":20,"text":304,"correct":26},"15mm",{"key":24,"text":306,"correct":22},"25mm",{"key":28,"text":308,"correct":26},"20mm",{"id":310,"libraryId":5,"type":15,"typeLabel":16,"stem":311,"options":312,"answer":20,"analysis":30},604432,"在地面热补或冷补的橡套电缆()耐压试验,应为2倍额定电压加1kV,持续5min不被击穿为合格。",[313,315,317],{"key":20,"text":314,"correct":22},"水浸",{"key":24,"text":316,"correct":26},"干燥",{"key":28,"text":318,"correct":26},"油浸",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":28,"analysis":30},604433,"高压电缆泄漏和耐压试验,每年进行()。",[323,325,327],{"key":20,"text":324,"correct":26},"3次",{"key":24,"text":326,"correct":26},"2次",{"key":28,"text":328,"correct":22},"1次",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":28,"analysis":30},604434,"安全电压取决于人体电阻和()的大小。",[333,335,337],{"key":20,"text":334,"correct":26},"电网绝缘电阻",{"key":24,"text":336,"correct":26},"工作电压",{"key":28,"text":338,"correct":22},"安全电流",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":24,"analysis":30},604435,"矿井供电系统接地网接地电阻值的测定,每()测定1次。",[343,344,346,348],{"key":20,"text":88,"correct":26},{"key":24,"text":345,"correct":22},"季",{"key":28,"text":347,"correct":26},"半年",{"key":142,"text":349,"correct":26},"年",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":20,"analysis":30},604436,"采用综合机械化采煤,煤层倾角大于()时,必须有防止煤(矸)窜出刮板输送机伤人的措施。",[354,356,358],{"key":20,"text":355,"correct":22},"25°",{"key":24,"text":357,"correct":26},"30°",{"key":28,"text":359,"correct":26},"35°",{"id":361,"libraryId":5,"type":15,"typeLabel":16,"stem":362,"options":363,"answer":20,"analysis":30},604437,"井下电气设备电压在36V以上就必须有()。",[364,366,368],{"key":20,"text":365,"correct":22},"保护接地",{"key":24,"text":367,"correct":26},"接地极",{"key":28,"text":369,"correct":26},"接地网",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":20,"analysis":30},604438,"瓦斯喷出区域、高瓦斯矿井及煤与瓦斯突出矿井中,掘进工作面的()应采用“三专供电”,即专用变压器、专用开关和专用线路。",[374,376,378,380],{"key":20,"text":375,"correct":22},"局部通风机",{"key":24,"text":377,"correct":26},"煤电钻",{"key":28,"text":379,"correct":26},"掘进机",{"key":142,"text":381,"correct":26},"刮板输送机",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":24,"analysis":30},604439,"井下架线电机车常用的是电压等级为250V或550V的()电源。",[386,388,390],{"key":20,"text":387,"correct":26},"交流",{"key":24,"text":389,"correct":22},"直流",{"key":28,"text":391,"correct":26},"高频",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":28,"analysis":30},604440,"转载机启动前一定要发出信号,确定无人在转载机上或附近工作后,先点动开机()次,然后正式启动。",[396,398,400],{"key":20,"text":397,"correct":26},"3至4",{"key":24,"text":399,"correct":26},"1至2",{"key":28,"text":401,"correct":22},"2至3",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":24,"analysis":30},604441,"密封圈内径与电缆外径差应小于()。",[406,408,410],{"key":20,"text":407,"correct":26},"2.5mm",{"key":24,"text":409,"correct":22},"1.0mm",{"key":28,"text":411,"correct":26},"2.0mm",{"id":413,"libraryId":5,"type":15,"typeLabel":16,"stem":414,"options":415,"answer":20,"analysis":30},604442,"因检修、停电或其他原因停止主要通风机运转时,必须制定()。",[416,418,420],{"key":20,"text":417,"correct":22},"停风措施",{"key":24,"text":419,"correct":26},"检查方案",{"key":28,"text":421,"correct":26},"停电措施",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":24,"analysis":30},604443,"井下低压馈电线上,必须装有()。",[426,428,430],{"key":20,"text":427,"correct":26},"选择性动作的单相接地保护装置",{"key":24,"text":429,"correct":22},"检漏保护装置或有选择性的漏电保护装置",{"key":28,"text":431,"correct":26},"漏电闭锁",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":28,"analysis":30},604444,"普通型携带式电气测量仪表,必须在瓦斯浓度为()以下的地点使用,并实时监测使用环境的瓦斯浓度。",[436,438,440],{"key":20,"text":437,"correct":26},"0.015",{"key":24,"text":439,"correct":26},"0.012",{"key":28,"text":441,"correct":22},"0.01",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":20,"analysis":30},604445,"低压配电点或装有()以上电气设备的地点,应装设局部接地极。",[446,448,450],{"key":20,"text":447,"correct":22},"3台",{"key":24,"text":449,"correct":26},"2台",{"key":28,"text":451,"correct":26},"4台",{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":454,"options":455,"answer":28,"analysis":30},604446,"在进行倒闸操作时,应由()填写操作票。",[456,458,460],{"key":20,"text":457,"correct":26},"监护人",{"key":24,"text":459,"correct":26},"负责人",{"key":28,"text":461,"correct":22},"操作人",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":28,"analysis":30},604447,"采用综合机械化采煤,煤层倾角大于()时,液压支架必须采取防倒、防滑措施。",[466,467,468],{"key":20,"text":357,"correct":26},{"key":24,"text":178,"correct":26},{"key":28,"text":180,"correct":22},{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":24,"analysis":30},604448,"井下机电设备硐室内,各种()之间应留出0.8m以上的距离。",[473,475,477],{"key":20,"text":474,"correct":26},"照明设备",{"key":24,"text":476,"correct":22},"设备相互",{"key":28,"text":478,"correct":26},"设备与墙壁",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":20,"analysis":30},604449,"在煤矿井下()使用矿灯的人员拆开、敲打、撞击矿灯。",[483,484,486],{"key":20,"text":160,"correct":22},{"key":24,"text":485,"correct":26},"允许",{"key":28,"text":487,"correct":26},"大巷里允许",{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":24,"analysis":30},604450,"刮板输送机与带式输送机搭接运输,搭接长度不小于500mm,机头、机尾高度差不大于()。",[492,494,496],{"key":20,"text":493,"correct":26},"300mm",{"key":24,"text":495,"correct":22},"500mm",{"key":28,"text":497,"correct":26},"400mm",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":28,"analysis":30},604451,"电动机断相是指三相交流电动机的()绕组断线。",[502,504,506],{"key":20,"text":503,"correct":26},"3相",{"key":24,"text":505,"correct":26},"2相",{"key":28,"text":507,"correct":22},"1相",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":24,"analysis":30},604452,"对使用中的防爆电气设备的防爆性能检查,检查周期为()1次。",[512,514,516,517],{"key":20,"text":513,"correct":26},"每周",{"key":24,"text":515,"correct":22},"每月",{"key":28,"text":212,"correct":26},{"key":142,"text":214,"correct":26},{"id":519,"libraryId":5,"type":15,"typeLabel":16,"stem":520,"options":521,"answer":20,"analysis":30},604453,"井下各级配电电压和各种电气设备的额定电压等级中,低压不超过()。",[522,524,526],{"key":20,"text":523,"correct":22},"1140V",{"key":24,"text":525,"correct":26},"660V",{"key":28,"text":527,"correct":26},"3300V",[529,532,535,538,541,544],{"id":530,"name":531,"category":7,"favorite":8},22,"安全管理人员",{"id":533,"name":534,"category":7,"favorite":8},23,"海洋石油天然气开采",{"id":536,"name":537,"category":7,"favorite":8},258,"金属非金属-地下矿山",{"id":539,"name":540,"category":7,"favorite":8},259,"金属非金属-露天矿山",{"id":542,"name":543,"category":7,"favorite":8},260,"金属非金属-小型露天采石场",{"id":545,"name":546,"category":7,"favorite":8},261,"金属冶炼(黑色金属铸造)"]