[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-197-9":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":577},{"id":5,"name":6,"category":7,"favorite":8},197,"电工类 (电网)","公务员",0,9,50,2675,[13,34,46,58,70,82,94,105,116,128,140,152,164,175,187,198,209,216,227,238,245,252,259,271,283,295,306,318,330,339,351,363,375,386,398,408,419,431,443,451,462,474,486,494,506,517,529,541,553,565],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},420385,1,"单选题","继电保护测量回路的作用（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","测量与被保护电气设备或线路工作状态有关的物理量的变化，如电流、电压等的变化，以确定电力系统是否发生了短路故障或出现不正常运行情况",true,{"key":24,"text":25,"correct":26},"B","当电力系统发生故障时，根据测量回路的输出信号，进行逻辑判断，以确定保护是否应该动作，并向执行元件发出相应的信号",false,{"key":28,"text":29,"correct":26},"C","执行逻辑回路的判断，发出切除故障的跳闸信号或指示不正常运行情况的信号",{"key":31,"text":32,"correct":26},"D","包括ABC","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},420386,"（ ）的作用是将系统的高电压转变为低电压。",[38,40,42,44],{"key":20,"text":39,"correct":26},"高电压断路器",{"key":24,"text":41,"correct":26},"隔离开关",{"key":28,"text":43,"correct":22},"电压互感器",{"key":31,"text":45,"correct":26},"电流互感器",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},420388,"使电流速断保护有最小保护范围的运行方式为系统（ ）",[50,52,54,56],{"key":20,"text":51,"correct":26},"最大运行方式",{"key":24,"text":53,"correct":22},"最小运行方式",{"key":28,"text":55,"correct":26},"正常运行方式",{"key":31,"text":57,"correct":26},"事故运行方式",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},420389,"当限时电流速断保护的灵敏系数不满足要求时，可考虑（ ）",[62,64,66,68],{"key":20,"text":63,"correct":26},"采用过电流保护",{"key":24,"text":65,"correct":26},"与下一级过电流保护相配合",{"key":28,"text":67,"correct":26},"与下一级电流速断保护相配合",{"key":31,"text":69,"correct":22},"与下一级限时电流速断保护相配合",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},420390,"双侧电源电网中，母线两侧方向过电流保护的方向元件在（ ）可以省略。",[74,76,78,80],{"key":20,"text":75,"correct":22},"该保护的时限较长时",{"key":24,"text":77,"correct":26},"该保护的时限较短时",{"key":28,"text":79,"correct":26},"两侧保护的时限相等时",{"key":31,"text":81,"correct":26},"两侧保护的时限不等时",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},420391,"电力系统的运行经验表明，架空线路的故障大部分是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"瞬时性故障",{"key":24,"text":89,"correct":26},"永久性故障",{"key":28,"text":91,"correct":26},"与线路的长度有关",{"key":31,"text":93,"correct":26},"以上都不对",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},420392,"发电厂接于110kV及以上双母线有三台及以上变压器时，则应（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":26},"有一台变压器中性点直接接地",{"key":24,"text":101,"correct":22},"每组母线有一台变压器中性点直接接地",{"key":28,"text":103,"correct":26},"三台及以上变压器均直接接地",{"key":31,"text":93,"correct":26},{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":20,"analysis":33},420393,"在变压器的零序等值电路中，（ ）的绕组端点与外电路断开，但与励磁支路并联。",[109,111,113,115],{"key":20,"text":110,"correct":22},"三角形接法",{"key":24,"text":112,"correct":26},"中性点不接地星形接法",{"key":28,"text":114,"correct":26},"中性点接地星形接法",{"key":31,"text":93,"correct":26},{"id":117,"libraryId":5,"type":15,"typeLabel":16,"stem":118,"options":119,"answer":20,"analysis":33},420394,"实现输电线路纵差保护必须考虑的中心问题是（ ）。",[120,122,124,126],{"key":20,"text":121,"correct":22},"差动电流",{"key":24,"text":123,"correct":26},"励磁涌流",{"key":28,"text":125,"correct":26},"不平衡电流",{"key":31,"text":127,"correct":26},"冲击电流",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":20,"analysis":33},420395,"在距离保护的Ⅰ段、Ⅱ段整定计算中乘一个小于1的可靠系数，目的是保证保护的（ ）。",[132,134,136,138],{"key":20,"text":133,"correct":22},"选择性",{"key":24,"text":135,"correct":26},"可靠性",{"key":28,"text":137,"correct":26},"灵敏性",{"key":31,"text":139,"correct":26},"速动性",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":24,"analysis":33},420396,"三种圆特效阻抗元件中，（ ）元件的动作阻抗与测量阻抗的阻抗角无关。",[144,146,148,150],{"key":20,"text":145,"correct":26},"方向阻抗",{"key":24,"text":147,"correct":22},"全阻抗",{"key":28,"text":149,"correct":26},"偏移特性阻抗",{"key":31,"text":151,"correct":26},"圆特效阻抗",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":24,"analysis":33},420397,"主变压器重瓦斯保护和轻瓦斯保护的正电源，正确接法是（ ）。",[156,158,160,162],{"key":20,"text":157,"correct":26},"使用同一保护正电源",{"key":24,"text":159,"correct":22},"重瓦斯保护接保护电源，轻瓦斯保护接信号电源",{"key":28,"text":161,"correct":26},"使用同一信号正电源",{"key":31,"text":163,"correct":26},"重瓦斯保护接信号电源，轻瓦斯保护接保护电源",{"id":165,"libraryId":5,"type":15,"typeLabel":16,"stem":166,"options":167,"answer":24,"analysis":33},420400,"系统发生振荡时，距离Ⅲ段保护不受振荡影响，其原因是（ ）。",[168,170,172,174],{"key":20,"text":169,"correct":26},"保护动作时限小于系统的振荡周期",{"key":24,"text":171,"correct":22},"保护动作时限大于系统的振荡周期",{"key":28,"text":173,"correct":26},"保护动作时限等于系统的振荡周期",{"key":31,"text":93,"correct":26},{"id":176,"libraryId":5,"type":15,"typeLabel":16,"stem":177,"options":178,"answer":31,"analysis":33},420401,"电力系统震荡时，（ ）可能会发生误动。",[179,181,183,185],{"key":20,"text":180,"correct":26},"电流差动保护",{"key":24,"text":182,"correct":26},"零序电流速断保护",{"key":28,"text":184,"correct":26},"纵差保护",{"key":31,"text":186,"correct":22},"过电流保护",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":189,"answer":24,"analysis":33},420402,[190,192,194,196],{"key":20,"text":191,"correct":26},"同名故障相中的超前相",{"key":24,"text":193,"correct":22},"同名故障相中的滞后相",{"key":28,"text":195,"correct":26},"非故障相",{"key":31,"text":197,"correct":26},"A相",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":200,"answer":28,"analysis":33},420403,[201,203,205,207],{"key":20,"text":202,"correct":26},"正序电流",{"key":24,"text":204,"correct":26},"零序电流",{"key":28,"text":206,"correct":22},"负序电流",{"key":31,"text":208,"correct":26},"相电流",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":211,"answer":24,"analysis":33},420404,[212,213,214,215],{"key":20,"text":191,"correct":26},{"key":24,"text":193,"correct":22},{"key":28,"text":195,"correct":26},{"key":31,"text":197,"correct":26},{"id":217,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":218,"answer":28,"analysis":33},420405,[219,221,223,225],{"key":20,"text":220,"correct":26},"滞后于C相电压一线路阻抗角",{"key":24,"text":222,"correct":26},"滞后于B相电压一线路阻抗角",{"key":28,"text":224,"correct":22},"滞后于BC相电压一线路阻抗角",{"key":31,"text":226,"correct":26},"滞后于A相电压一线路阻抗角",{"id":228,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":229,"answer":20,"analysis":33},420406,[230,232,234,236],{"key":20,"text":231,"correct":22},"30°",{"key":24,"text":233,"correct":26},"45°",{"key":28,"text":235,"correct":26},"60°",{"key":31,"text":237,"correct":26},"90°",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":240,"answer":28,"analysis":33},420407,[241,242,243,244],{"key":20,"text":220,"correct":26},{"key":24,"text":222,"correct":26},{"key":28,"text":224,"correct":22},{"key":31,"text":226,"correct":26},{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":247,"answer":28,"analysis":33},420408,[248,249,250,251],{"key":20,"text":231,"correct":26},{"key":24,"text":233,"correct":26},{"key":28,"text":235,"correct":22},{"key":31,"text":237,"correct":26},{"id":253,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":254,"answer":28,"analysis":33},420409,[255,256,257,258],{"key":20,"text":202,"correct":26},{"key":24,"text":204,"correct":26},{"key":28,"text":206,"correct":22},{"key":31,"text":208,"correct":26},{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":20,"analysis":33},420411,"在中性点非直接接地电网中，由同一变电所母线引出的两条并联运行线路上发生跨线异相两点接地短路时，若两条线路保护动作时限相同，则采用不完全星型接线的电流保护动作情况时（ ）。",[263,265,267,269],{"key":20,"text":264,"correct":22},"有2\u002F3机会只切一条线路",{"key":24,"text":266,"correct":26},"有1\u002F3机会只切一条线路",{"key":28,"text":268,"correct":26},"100%切除两条线路",{"key":31,"text":270,"correct":26},"不动作即两条都不切",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":28,"analysis":33},420412,"对于间接比较的高频保护，要求保护区内故障时保护动作行为不受通道破坏的影响，应该选择的间接比较信号是（ ）。",[275,277,279,281],{"key":20,"text":276,"correct":26},"允许信号",{"key":24,"text":278,"correct":26},"跳闸信号",{"key":28,"text":280,"correct":22},"闭锁信号",{"key":31,"text":282,"correct":26},"任意信号",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":24,"analysis":33},420413,"在中性点非直接接地系统中，为了提高供电的可靠性，电流保护的接线方式应采用（ ）",[287,289,291,293],{"key":20,"text":288,"correct":26},"三相星接线",{"key":24,"text":290,"correct":22},"两相星接线",{"key":28,"text":292,"correct":26},"0°接线方式",{"key":31,"text":294,"correct":26},"90°接线方式",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":20,"analysis":33},420414,"单相重合闸主要应用于（ ）。",[299,301,303,305],{"key":20,"text":300,"correct":22},"220～500kV的线路",{"key":24,"text":302,"correct":26},"110kV的线路",{"key":28,"text":304,"correct":26},"任何电压等级的线路",{"key":31,"text":93,"correct":26},{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":24,"analysis":33},420415,"纵联差动保护的通道最好选择（ ）。",[310,312,314,316],{"key":20,"text":311,"correct":26},"导引线",{"key":24,"text":313,"correct":22},"光纤",{"key":28,"text":315,"correct":26},"微波",{"key":31,"text":317,"correct":26},"电力线载波",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":20,"analysis":33},420416,"为了保证纵差保护的选择性，差动继电器的启动电流应躲过（ ）。",[322,324,326,328],{"key":20,"text":323,"correct":22},"最大不平衡电流",{"key":24,"text":325,"correct":26},"短路电流",{"key":28,"text":327,"correct":26},"励磁电流",{"key":31,"text":329,"correct":26},"精工电流",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":24,"analysis":33},420418,"三种圆特性阻抗元件中，（ ）元件的动作阻抗与测量阻抗的阻抗角无关。",[334,335,336,337],{"key":20,"text":145,"correct":26},{"key":24,"text":147,"correct":22},{"key":28,"text":149,"correct":26},{"key":31,"text":338,"correct":26},"圆特性阻抗",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":28,"analysis":33},420420,"当变压器外部故障时，有较大的穿越性短路电流流过变压器，这时变压器的差动保护（ ）。",[343,345,347,349],{"key":20,"text":344,"correct":26},"立即动作",{"key":24,"text":346,"correct":26},"延时动作",{"key":28,"text":348,"correct":22},"不应动作",{"key":31,"text":350,"correct":26},"视短路时间长短而定",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":24,"analysis":33},420423,"变压器励磁涌流汇总含有明显的（ ）分量，使波形偏向时间轴的一侧。",[355,357,359,361],{"key":20,"text":356,"correct":26},"周期",{"key":24,"text":358,"correct":22},"非周期",{"key":28,"text":360,"correct":26},"矩形波",{"key":31,"text":362,"correct":26},"基波",{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":24,"analysis":33},420424,"高频收发信机通过耦合电容器等设备接于一相导线与大地之间的发方式为（ ）。",[367,369,371,373],{"key":20,"text":368,"correct":26},"一相制",{"key":24,"text":370,"correct":22},"相地制",{"key":28,"text":372,"correct":26},"通信制",{"key":31,"text":374,"correct":26},"两相制",{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":28,"analysis":33},420425,"变压器比率制动差动保护设置制动线圈的主要原因是（ ）。",[379,381,383,385],{"key":20,"text":380,"correct":26},"为了躲避励磁涌流",{"key":24,"text":382,"correct":26},"为了在内部故障时提高保护的可靠性",{"key":28,"text":384,"correct":22},"为了在区外故障时提高保护的安全性",{"key":31,"text":93,"correct":26},{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":24,"analysis":33},420427,"综合重合闸与线路保护接口分M，N，R，Q等端子，其中M端子（ ）。",[390,392,394,396],{"key":20,"text":391,"correct":26},"供能躲非全相运行不误动保护接入",{"key":24,"text":393,"correct":22},"供非全相运行时会误动的保护接入",{"key":28,"text":395,"correct":26},"供直接三相跳闸不重合的保护接入",{"key":31,"text":397,"correct":26},"供相邻线路非全相运行时会误动的保护接入",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":31,"analysis":33},420428,"TV指的是（ ）。",[402,403,405,407],{"key":20,"text":45,"correct":26},{"key":24,"text":404,"correct":26},"电流继电器",{"key":28,"text":406,"correct":26},"信号继电器",{"key":31,"text":43,"correct":22},{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":410,"options":411,"answer":31,"analysis":33},420430,"当限时电流速断保护灵敏度不满足要求时，可考虑（ ）。",[412,413,415,417],{"key":20,"text":63,"correct":26},{"key":24,"text":414,"correct":26},"与下一级电流速断保护配合",{"key":28,"text":416,"correct":26},"与下一级过电流保护配合",{"key":31,"text":418,"correct":22},"与下一级限时电流速断保护配合",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":24,"analysis":33},420432,"过电流继电器的返回系数（ ）",[423,425,427,429],{"key":20,"text":424,"correct":26},"等于0",{"key":24,"text":426,"correct":22},"小于1",{"key":28,"text":428,"correct":26},"等于1",{"key":31,"text":430,"correct":26},"大于1",{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":20,"analysis":33},420433,"发电机横差保护的作用是（ ）",[435,437,439,441],{"key":20,"text":436,"correct":22},"保护定子绕组匝间短路",{"key":24,"text":438,"correct":26},"保护定子绕组相间短路",{"key":28,"text":440,"correct":26},"保护定子绕组接地短路",{"key":31,"text":442,"correct":26},"保护转子绕组一点接地故障",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":24,"analysis":33},420434,"y，d11接线的变压器低压三角形侧发生两相短路时，y侧有一相电流比另外两相电流大，该相是（ ）。",[447,448,449,450],{"key":20,"text":191,"correct":26},{"key":24,"text":193,"correct":22},{"key":28,"text":195,"correct":26},{"key":31,"text":197,"correct":26},{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":453,"answer":20,"analysis":33},420437,[454,456,458,460],{"key":20,"text":455,"correct":22},"≤4.5",{"key":24,"text":457,"correct":26},"≥4.5",{"key":28,"text":459,"correct":26},"＞3",{"key":31,"text":461,"correct":26},"＜3",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":24,"analysis":33},420438,"瓦斯保护是变压器的（ ）。",[466,468,470,472],{"key":20,"text":467,"correct":26},"主后备保护",{"key":24,"text":469,"correct":22},"内部故障的主保护",{"key":28,"text":471,"correct":26},"外部故障的主保护",{"key":31,"text":473,"correct":26},"外部故障的后备保护",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":24,"analysis":33},420439,"距离保护中阻抗继电器，需要加记忆回路和引入第三相电压的是（ ）。",[478,480,482,484],{"key":20,"text":479,"correct":26},"全阻抗继电器",{"key":24,"text":481,"correct":22},"方向阻抗继电器",{"key":28,"text":483,"correct":26},"偏移特性阻抗继电器",{"key":31,"text":485,"correct":26},"偏移阻抗继电器和方向阻抗继电器",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":20,"analysis":33},420441,"电力系统中变压器通常采用Y，d11接线方式，两侧线电流的相位差（ ）。",[490,491,492,493],{"key":20,"text":231,"correct":22},{"key":24,"text":233,"correct":26},{"key":28,"text":235,"correct":26},{"key":31,"text":237,"correct":26},{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":28,"analysis":33},420442,"自动重合闸的动作次数为（ ）。",[498,500,502,504],{"key":20,"text":499,"correct":26},"一次",{"key":24,"text":501,"correct":26},"三次",{"key":28,"text":503,"correct":22},"符合预先规定的次数",{"key":31,"text":505,"correct":26},"五次",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":20,"analysis":33},420443,"变压器过流保护采用低电压起动时，低电压继电器的起动电压应小于（ ）。",[510,512,514,516],{"key":20,"text":511,"correct":22},"正常运行时的最低电压",{"key":24,"text":513,"correct":26},"正常工作电压",{"key":28,"text":515,"correct":26},"正常工作最高电压",{"key":31,"text":93,"correct":26},{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":28,"analysis":33},420444,"变压器的电流速断保护与（ ）保护配合，以反应变压器绕组及变压器电源侧的引出线套管上的各种故障。",[521,523,525,527],{"key":20,"text":522,"correct":26},"过电流",{"key":24,"text":524,"correct":26},"过负荷",{"key":28,"text":526,"correct":22},"瓦斯",{"key":31,"text":528,"correct":26},"距离保护",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":20,"analysis":33},420445,"纵差动保护使用于（ ）线路。",[533,535,537,539],{"key":20,"text":534,"correct":22},"短",{"key":24,"text":536,"correct":26},"长",{"key":28,"text":538,"correct":26},"所有",{"key":31,"text":540,"correct":26},"中等长度线路",{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":20,"analysis":33},420446,"标识制动型差动继电器的灵敏性较比率制动型差动继电器灵敏性（ ）",[545,547,549,551],{"key":20,"text":546,"correct":22},"高",{"key":24,"text":548,"correct":26},"低",{"key":28,"text":550,"correct":26},"两相短路时高，三相短路时低",{"key":31,"text":552,"correct":26},"两相短路时低，三相短路时高",{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":20,"analysis":33},420447,"纵联差动保护不能适用于输电线路的原因是（ ）。",[557,559,561,563],{"key":20,"text":558,"correct":22},"不经济",{"key":24,"text":560,"correct":26},"不满足灵敏性要求",{"key":28,"text":562,"correct":26},"不能保护线路全长",{"key":31,"text":564,"correct":26},"灵敏性不高",{"id":566,"libraryId":5,"type":15,"typeLabel":16,"stem":567,"options":568,"answer":28,"analysis":33},420448,"高频阻波器的作用是（ ）",[569,571,573,575],{"key":20,"text":570,"correct":26},"限制短路电流",{"key":24,"text":572,"correct":26},"防止工频电流窜越",{"key":28,"text":574,"correct":22},"防止高频电流窜越",{"key":31,"text":576,"correct":26},"补偿接地电流",[578,582,586,589,592,596],{"id":579,"name":580,"category":7,"favorite":581},256,"综合应用能力",6,{"id":583,"name":584,"category":7,"favorite":585},194,"《公安》基础知识+专业",5,{"id":587,"name":588,"category":7,"favorite":585},195,"政法干警",{"id":590,"name":591,"category":7,"favorite":585},255,"职业能力倾向测验",{"id":593,"name":594,"category":7,"favorite":595},212,"国家公务员-行政能力测试",4,{"id":597,"name":598,"category":7,"favorite":595},254,"公共基础知识"]