[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-197-40":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":607},{"id":5,"name":6,"category":7,"favorite":8},197,"电工类 (电网)","公务员",0,40,50,2675,[13,35,48,61,74,87,100,112,124,136,148,161,173,185,197,206,217,229,241,254,267,275,287,299,311,318,329,341,353,365,372,380,392,404,416,428,440,452,464,476,486,498,510,522,534,546,558,570,582,595],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},422137,2,"多选题","电力系统高低压短路电流计算的区别有（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","高压短路电流的计算不考虑电阻，低压考虑",true,{"key":24,"text":25,"correct":26},"B","高压短路电流计算不考虑接地电阻，低压考虑",false,{"key":28,"text":29,"correct":22},"C","高压短路电流计算采用标幺值计算，低压采用有名值计算",{"key":31,"text":32,"correct":26},"D","高压认为系统的磁路元件都不饱和，满足叠加定理，低压认为饱和","AC","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},422138,"以下说法错误的是（ ）。",[39,41,43,45],{"key":20,"text":40,"correct":26},"真正的无限大功率电源是没有的，而只能是一个相对的概念",{"key":24,"text":42,"correct":22},"无限大功率电源存在",{"key":28,"text":44,"correct":26},"若供电电源的内阻抗小于短路回路总阻抗的10%时，则可认为供电电源为无限大功率电源",{"key":31,"text":46,"correct":22},"若供电电源的内阻抗小于短路回路总阻抗的15%时，则可认为供电电源为无限大功率电源","BD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},422139,"以下是对称阵的有（ ）。",[52,54,56,58],{"key":20,"text":53,"correct":26},"雅可比矩阵",{"key":24,"text":55,"correct":22},"节点导纳矩阵",{"key":28,"text":57,"correct":22},"节点阻抗矩阵",{"key":31,"text":59,"correct":26},"节点电压矩阵","BC",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":73,"analysis":34},422140,"对于无功补偿装置与电力网的连接，下列原则正确的是（ ）。",[65,67,69,71],{"key":20,"text":66,"correct":22},"无功补偿装置都可连接于变电所的母线上",{"key":24,"text":68,"correct":22},"无功补偿装置都可连接于直流输电换流站的母线上",{"key":28,"text":70,"correct":22},"配电网中，根据无功就地补偿原则，安装中小型电容器就地补偿",{"key":31,"text":72,"correct":22},"负荷密集的供电中心集中安装大中型无功补偿装置","ABCD",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":86,"analysis":34},422141,"关于同步发电机机端三相短路的分析，下述说法中正确的是（ ）。",[78,80,82,84],{"key":20,"text":79,"correct":22},"派克变换的目的是将描述发电机电磁暂态过程的原始电压方程由变系数微分方程变为常系数微分方程",{"key":24,"text":81,"correct":22},"将派克变换后的同步发电机基本方程进行拉普拉斯变换的目的是将基本方程由微分方程变为代数方程",{"key":28,"text":83,"correct":22},"对同步发电机机端三相短路进行定量分析的基本方法是，利用象函数表示的发电机基本方程和边界条件，求出待求量的象函数，再进行拉普拉斯变换求待求量的原函数（d、q、0等效绕组系统中的电气量）",{"key":31,"text":85,"correct":26},"派克变换仅适用于同步发电机三相对称短路的分析计算","ABC",{"id":88,"libraryId":5,"type":15,"typeLabel":16,"stem":89,"options":90,"answer":99,"analysis":34},422143,"下列无功电源中，电压调节效应是正的有（ ）。",[91,93,95,97],{"key":20,"text":92,"correct":22},"调相机",{"key":24,"text":94,"correct":26},"TSC型静止无功补偿器",{"key":28,"text":96,"correct":22},"SR型静止无功补偿器",{"key":31,"text":98,"correct":22},"TCR型静止无功补偿器","ACD",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":73,"analysis":34},422145,"抑制谐波主要措施有（ ）。",[104,106,108,110],{"key":20,"text":105,"correct":22},"变压器采用星、三角接线",{"key":24,"text":107,"correct":22},"加装调谐波器",{"key":28,"text":109,"correct":22},"并联补偿电容器，串联电抗器",{"key":31,"text":111,"correct":22},"增加整流器的脉冲次数",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":73,"analysis":34},422149,"同步发电机的基本方程是以理想电机模型为基础进行讨论的。理想电机有哪些基本假设（ ）。",[116,118,120,122],{"key":20,"text":117,"correct":22},"电机铁芯部分的导磁系数是常数，忽略磁饱和的影响，可以运用叠加原理",{"key":24,"text":119,"correct":22},"转子在结构上本身的交、直轴完全对称，定子绕组三相对称空间上差120。",{"key":28,"text":121,"correct":22},"定子电流在空气隙中产生正弦分布的磁势，转子与定子之间的互感磁通亦如此",{"key":31,"text":123,"correct":22},"定子和转子铁芯的槽和通风沟不影响其电感，即认为定子、转子铁芯的表面是光滑的",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":99,"analysis":34},422151,"分析单机无穷大系统暂态稳定性时，假设条件有（ ）。",[128,130,132,134],{"key":20,"text":129,"correct":22},"网络频率为50Hz",{"key":24,"text":131,"correct":26},"不考虑网络负序参数和零序参数",{"key":28,"text":133,"correct":22},"不考虑非周期分量",{"key":31,"text":135,"correct":22},"不计原动机调速器作用",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":73,"analysis":34},422152,"关于短路电流的影响，下列说法正确的是（ ）。",[140,142,144,146],{"key":20,"text":141,"correct":22},"短路电流是正常负荷电流的十多倍，产生的热量影响设备",{"key":24,"text":143,"correct":22},"短路还会引起电网中电压降低",{"key":28,"text":145,"correct":22},"电力负荷异步电动机，它的电磁转矩与外施电压的平方成正比，转矩受影响较大",{"key":31,"text":147,"correct":22},"导体也会受到很大的电动力的冲击，致使导体变形，甚至损坏",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":160,"analysis":34},422153,"衡量电力系统运行经济性的指标是（ ）。",[152,154,156,158],{"key":20,"text":153,"correct":26},"电能质量",{"key":24,"text":155,"correct":22},"比耗量",{"key":28,"text":157,"correct":22},"线损率",{"key":31,"text":159,"correct":22},"输电效率","BCD",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":86,"analysis":34},422154,"下列属于无功补偿装置的有（ ）。",[165,167,169,171],{"key":20,"text":166,"correct":22},"并联电容",{"key":24,"text":168,"correct":22},"并联电抗",{"key":28,"text":170,"correct":22},"静止无功补偿器",{"key":31,"text":172,"correct":26},"以上都不对",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":47,"analysis":34},422155,"当无功分布不合理而造成电压偏差过大时，采用的措施有（ ）。",[177,179,181,183],{"key":20,"text":178,"correct":26},"发电机端电压调压",{"key":24,"text":180,"correct":22},"改变变压器分接头",{"key":28,"text":182,"correct":26},"并联补偿设置",{"key":31,"text":184,"correct":22},"改变线路参数",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":86,"analysis":34},422159,"在分析机电过程中，一般采用以下假设（ ）。",[189,191,193,195],{"key":20,"text":190,"correct":22},"略去发电机定子绕组电阻",{"key":24,"text":192,"correct":22},"设机组转速接近同步转速",{"key":28,"text":194,"correct":22},"不计定子绕组的电磁暂态过程",{"key":31,"text":196,"correct":26},"略去发电机转子绕组电阻",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":205,"analysis":34},422160,"在变压器τ形等值电路中，可变损耗包括（ ）。",[201,202,203,204],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},"CD",{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":86,"analysis":34},422161,"下列关于静稳储备系数的定义正确的是（ ）。",[210,211,213,215],{"key":20,"text":34,"correct":22},{"key":24,"text":212,"correct":22},"正常运行方式下应不小于15%～20%",{"key":28,"text":214,"correct":22},"事故运行方式下应不小于10%",{"key":31,"text":216,"correct":26},"为输送功率的极限最大值",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":73,"analysis":34},422162,"同步发电机并联合闸的条件有（ ）。",[221,223,225,227],{"key":20,"text":222,"correct":22},"发电机频率等于电网的频率",{"key":24,"text":224,"correct":22},"发电机的电压幅值等于电网电压的幅值，且波形一致",{"key":28,"text":226,"correct":22},"发电机的电压相序与电网的电压相序相同",{"key":31,"text":228,"correct":22},"在合闸时，发电机的电压相位与电网电压的相位一样",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":205,"analysis":34},422163,"下列措施中，能够提高同步大电机并列运行静态稳定性的有（ ）。",[233,235,237,239],{"key":20,"text":234,"correct":26},"线路装设重合闸装置",{"key":24,"text":236,"correct":26},"快速切除故障",{"key":28,"text":238,"correct":22},"架空线路采用分裂导线",{"key":31,"text":240,"correct":22},"发电机装设自动励磁调节装置",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":253,"analysis":34},422164,"分裂导线的主要目的是（ ）。",[245,247,249,251],{"key":20,"text":246,"correct":22},"减小线路电抗",{"key":24,"text":248,"correct":22},"减小电晕损耗",{"key":28,"text":250,"correct":26},"增大线路电阻",{"key":31,"text":252,"correct":22},"提高输电能力","ABD",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":266,"analysis":34},422166,"有功功率最优分配包括（ ）。",[258,260,262,264],{"key":20,"text":259,"correct":22},"有功功率电源的最优组合",{"key":24,"text":261,"correct":22},"有功功率负荷的最优分配",{"key":28,"text":263,"correct":26},"有功功率线路的最小损耗",{"key":31,"text":265,"correct":26},"有功功率电阻的最优分布","AB",{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":86,"analysis":34},422168,"对称分量法，正序负序零序的特点正确的是（ ）。",[271,272,273,274],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":276,"libraryId":5,"type":15,"typeLabel":16,"stem":277,"options":278,"answer":73,"analysis":34},422169,"架空线由（ ）、金具组成。",[279,281,283,285],{"key":20,"text":280,"correct":22},"导线",{"key":24,"text":282,"correct":22},"避雷线",{"key":28,"text":284,"correct":22},"杆塔",{"key":31,"text":286,"correct":22},"绝缘子",{"id":288,"libraryId":5,"type":15,"typeLabel":16,"stem":289,"options":290,"answer":253,"analysis":34},422170,"电能质量包括（ ）。",[291,293,295,297],{"key":20,"text":292,"correct":22},"电压质量",{"key":24,"text":294,"correct":22},"频率质量",{"key":28,"text":296,"correct":26},"电流质量",{"key":31,"text":298,"correct":22},"波形质量",{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":73,"analysis":34},422171,"电压质量的指标有（ ）。",[303,305,307,309],{"key":20,"text":304,"correct":22},"电压降落",{"key":24,"text":306,"correct":22},"电压损耗",{"key":28,"text":308,"correct":22},"电压偏移",{"key":31,"text":310,"correct":22},"电压调整",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":313,"answer":253,"analysis":34},422172,[314,315,316,317],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":86,"analysis":34},422173,"下列选项中，对电力系统静态稳定判据正确的是（ ）。",[322,323,325,327],{"key":20,"text":34,"correct":22},{"key":24,"text":324,"correct":22},"δ＜90°",{"key":28,"text":326,"correct":22},"曲线的上升部分",{"key":31,"text":328,"correct":26},"δ＜180°",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":33,"analysis":34},422175,"要增加并联在电网上运行的发电机的稳定性，可以（ ）。",[333,335,337,339],{"key":20,"text":334,"correct":22},"增大励磁电流",{"key":24,"text":336,"correct":26},"减小励磁电流",{"key":28,"text":338,"correct":22},"减小原动机输出功率",{"key":31,"text":340,"correct":26},"增大原动机输出功率",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":60,"analysis":34},422176,"线路电压超过220kV时，为减小电晕损耗或线路电抗，应采用（ ）。",[345,347,349,351],{"key":20,"text":346,"correct":26},"粗导线",{"key":24,"text":348,"correct":22},"分裂导线",{"key":28,"text":350,"correct":22},"扩径导线",{"key":31,"text":352,"correct":26},"铜导线",{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":33,"analysis":34},422177,"一台额定电压为13.8kV，额定功率为125mW，功率因数为0.85的发电机，其电抗标幺值为0.18（以发电机额定电压和功率为基准值）。则以13.8kV和100mVA为电压和功率基准值的电抗标幺值为（ ）实际值为（ ）。",[357,359,361,363],{"key":20,"text":358,"correct":22},"0.122",{"key":24,"text":360,"correct":26},"0.132",{"key":28,"text":362,"correct":22},"0.233",{"key":31,"text":364,"correct":26},"0.333",{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":367,"answer":253,"analysis":34},422178,[368,369,370,371],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":373,"libraryId":5,"type":15,"typeLabel":16,"stem":374,"options":375,"answer":73,"analysis":34},422179,"对于二无功补偿装置与电力网的连接，下列原则正确的是（ ）。",[376,377,378,379],{"key":20,"text":66,"correct":22},{"key":24,"text":68,"correct":22},{"key":28,"text":70,"correct":22},{"key":31,"text":72,"correct":22},{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":60,"analysis":34},422180,"有功功率流过线路电抗时，产生的是（ ）。",[384,386,388,390],{"key":20,"text":385,"correct":26},"有功损耗",{"key":24,"text":387,"correct":22},"无功损耗",{"key":28,"text":389,"correct":22},"可变损耗",{"key":31,"text":391,"correct":26},"不变损耗",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":253,"analysis":34},422181,"关于短路故障时的负序电流，下述说法中错误的是（ ）。",[396,398,400,402],{"key":20,"text":397,"correct":22},"任何短路情况下，短路电流中都包含有负序分量",{"key":24,"text":399,"correct":22},"任何相间短路情况下，短路电流中都包含负序分量",{"key":28,"text":401,"correct":26},"只有在发生不对称短路时，短路电流中才会出现负序分量",{"key":31,"text":403,"correct":22},"只有在中性点接地系统发生接地短路时，短路电流中才会出现负序分量",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":60,"analysis":34},422182,"变压器的零序阻抗与（ ）有关。",[408,410,412,414],{"key":20,"text":409,"correct":26},"是油变压器还是干式变压器",{"key":24,"text":411,"correct":22},"变压器三相绕组的接线方式",{"key":28,"text":413,"correct":22},"变压器的结构",{"key":31,"text":415,"correct":26},"是单相变压器还是三相变压器",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":86,"analysis":34},422183,"标幺值的优点是（ ）。",[420,422,424,426],{"key":20,"text":421,"correct":22},"计算结果清晰",{"key":24,"text":423,"correct":22},"便于判断计算结果正确性",{"key":28,"text":425,"correct":22},"可大量简化计算",{"key":31,"text":427,"correct":26},"无量纲，概念不清",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":266,"analysis":34},422184,"过渡电阻对单相阻抗继电器（Ⅰ类）的影响有（ ）",[432,434,436,438],{"key":20,"text":433,"correct":22},"稳态超越；",{"key":24,"text":435,"correct":22},"失去方向性；",{"key":28,"text":437,"correct":26},"暂态超越；",{"key":31,"text":439,"correct":26},"振荡时易发生误动；",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":73,"analysis":34},422185,"高频通道的基本构成元件有（ ）",[444,446,448,450],{"key":20,"text":445,"correct":22},"阻波器",{"key":24,"text":447,"correct":22},"结合电容器",{"key":28,"text":449,"correct":22},"连接滤波器",{"key":31,"text":451,"correct":22},"高频收、发信机",{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":454,"options":455,"answer":266,"analysis":34},422186,"自耦变压器的接地保护应装设：（ ）",[456,458,460,462],{"key":20,"text":457,"correct":22},"零序过电流；",{"key":24,"text":459,"correct":22},"零序方向过电流；",{"key":28,"text":461,"correct":26},"零序过电压；",{"key":31,"text":463,"correct":26},"零序间隙过流；",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":86,"analysis":34},422187,"变压器励磁涌流描述正确的是（ ）。",[468,470,472,474],{"key":20,"text":469,"correct":22},"数值可能达到变压器额定电流的6～8倍。",{"key":24,"text":471,"correct":22},"包含有大量的非周期分量",{"key":28,"text":473,"correct":22},"波形之间出现间断",{"key":31,"text":475,"correct":26},"包含有大量的高次谐波，以5次谐波为主",{"id":477,"libraryId":5,"type":15,"typeLabel":16,"stem":478,"options":479,"answer":60,"analysis":34},422188,"不需要振荡闭锁的继电器有：（ ）",[480,482,484],{"key":20,"text":481,"correct":26},"极化量带记忆的阻抗继电器；",{"key":24,"text":483,"correct":22},"工频变化量距离继电器；",{"key":28,"text":485,"correct":22},"多相补偿距离继电器；",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":160,"analysis":34},422190,"用熔断器保护的电压互感器，需要进行（ ）。",[490,492,494,496],{"key":20,"text":491,"correct":26},"动稳定与热稳定",{"key":24,"text":493,"correct":22},"电压选择",{"key":28,"text":495,"correct":22},"精度校验",{"key":31,"text":497,"correct":22},"绝缘类型",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":253,"analysis":34},422191,"在电流互感器的选择与检验中，需选择或校验（ ）。",[502,504,506,508],{"key":20,"text":503,"correct":22},"额定电压",{"key":24,"text":505,"correct":22},"二次负荷",{"key":28,"text":507,"correct":26},"机械负荷",{"key":31,"text":509,"correct":22},"动稳定",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":86,"analysis":34},422192,"绝缘子按材料分包括（ ）。",[514,516,518,520],{"key":20,"text":515,"correct":22},"瓷绝缘子",{"key":24,"text":517,"correct":22},"玻璃绝缘子",{"key":28,"text":519,"correct":22},"复合绝缘子",{"key":31,"text":521,"correct":26},"水泥绝缘子",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":73,"analysis":34},422193,"为减小短路电流，可选用计算阻抗较大的接线和运行方式是（ ）。",[526,528,530,532],{"key":20,"text":527,"correct":22},"大容量发电机用单元接线",{"key":24,"text":529,"correct":22},"降压变电站中用变压器低压分列运行方式",{"key":28,"text":531,"correct":22},"双回路电路采用单回路运行",{"key":31,"text":533,"correct":22},"环形供电网络在环网穿越功率最小处开环运行",{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":73,"analysis":34},422194,"电气主接线指一次设备的连接电路，又叫一次电路或主电路，表示了电能（ ）的关系。",[538,540,542,544],{"key":20,"text":539,"correct":22},"产生",{"key":24,"text":541,"correct":22},"汇集",{"key":28,"text":543,"correct":22},"分配",{"key":31,"text":545,"correct":22},"传输",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":86,"analysis":34},422196,"对电力系统运行的基本要求有（ ）。",[550,552,554,556],{"key":20,"text":551,"correct":22},"保证对用户供电的可靠性",{"key":24,"text":553,"correct":22},"保证电能的良好质量",{"key":28,"text":555,"correct":22},"保证运行的最大经济性",{"key":31,"text":557,"correct":26},"必须有大量的电力存储",{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":73,"analysis":34},422197,"影响输电电压等级发展的主要原因有（ ）。",[562,564,566,568],{"key":20,"text":563,"correct":22},"长距离输送电能",{"key":24,"text":565,"correct":22},"大容量输送电能",{"key":28,"text":567,"correct":22},"节省基建投资和运行费用",{"key":31,"text":569,"correct":22},"电力系统互联",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":33,"analysis":34},422200,"下列属于电力系统的二次设备的是（ ）。",[574,576,578,580],{"key":20,"text":575,"correct":22},"测量表计，如电压表、电流表、功率表和电能表等，用于测量电路中的电气参数",{"key":24,"text":577,"correct":26},"接通或断开电路的开关电器，如断路器、隔离开关、负荷开关、熔断器、接触器等",{"key":28,"text":579,"correct":22},"直流电源设备，包括直流发电机组、蓄电池组和硅整流装置等，供给控制、保护用的直流电源和厂用直流负荷、事故照明用电等",{"key":31,"text":581,"correct":26},"接地装置，电力系统中性点的工作接地、保护人身安全的保护接地，均同埋入地中的接地装置相连",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":594,"analysis":34},422202,"导体运行中的状态包括（ ）。",[586,588,590,592],{"key":20,"text":587,"correct":22},"正常工作状态",{"key":24,"text":589,"correct":26},"不正常工作状态",{"key":28,"text":591,"correct":26},"断路工作状态",{"key":31,"text":593,"correct":22},"短路工作状态","AD",{"id":596,"libraryId":5,"type":15,"typeLabel":16,"stem":597,"options":598,"answer":86,"analysis":34},422204,"关于厂用负荷分类，正确的描述是（ ）。",[599,601,603,605],{"key":20,"text":600,"correct":22},"凡是属于短时（手动切换恢复供电所需要的时间）停电会造成主辅设备损坏、危及人身安全、主机停运及影响大量出力的厂用负荷，都属于Ⅰ类负荷",{"key":24,"text":602,"correct":22},"允许短时停电（几秒至几分钟），恢复供电后，不致造成生产混乱的厂用负荷称为Ⅱ类厂用负荷",{"key":28,"text":604,"correct":22},"较长时间停电（几个小时），不会直接影响生产，仅造成生产上不方便的负荷为Ⅲ类厂用负荷",{"key":31,"text":606,"correct":26},"直流保安负荷属于事故保安负荷，而交流保安负荷不属于事故保安负荷",[608,612,616,619,622,626],{"id":609,"name":610,"category":7,"favorite":611},256,"综合应用能力",6,{"id":613,"name":614,"category":7,"favorite":615},194,"《公安》基础知识+专业",5,{"id":617,"name":618,"category":7,"favorite":615},195,"政法干警",{"id":620,"name":621,"category":7,"favorite":615},255,"职业能力倾向测验",{"id":623,"name":624,"category":7,"favorite":625},212,"国家公务员-行政能力测试",4,{"id":627,"name":628,"category":7,"favorite":625},254,"公共基础知识"]