[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-197-39":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":593},{"id":5,"name":6,"category":7,"favorite":8},197,"电工类 (电网)","公务员",0,39,50,2675,[13,34,47,60,73,85,97,108,120,133,145,157,169,181,193,205,217,230,242,254,267,279,291,304,316,328,339,350,361,369,380,388,395,402,409,416,428,440,452,464,477,489,501,513,525,537,549,557,569,581],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":21},422074,2,"多选题","下列关于静态稳定储备系数的定义正确的是（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","",true,{"key":24,"text":25,"correct":22},"B","正常运行方式下应不小于15%～20%",{"key":27,"text":28,"correct":22},"C","事故运行方式下应不小于10%",{"key":30,"text":31,"correct":32},"D","为输送功率的极限最大值",false,"ABC",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":46,"analysis":21},422076,"下列哪些元件的参数是以本身额定容量为基准的标幺值？（ ）",[38,40,42,44],{"key":20,"text":39,"correct":32},"线路",{"key":24,"text":41,"correct":22},"发电机",{"key":27,"text":43,"correct":22},"变压器",{"key":30,"text":45,"correct":22},"电抗器","BCD",{"id":48,"libraryId":5,"type":15,"typeLabel":16,"stem":49,"options":50,"answer":59,"analysis":21},422077,"目前，我国的输电方式有（ ）。",[51,53,55,57],{"key":20,"text":52,"correct":22},"以交流为主",{"key":24,"text":54,"correct":22},"直流输电",{"key":27,"text":56,"correct":22},"灵活交流输电",{"key":30,"text":58,"correct":22},"特高压交流输电","ABCD",{"id":61,"libraryId":5,"type":15,"typeLabel":16,"stem":62,"options":63,"answer":72,"analysis":21},422078,"中性点运行方式有（ ）。",[64,66,68,70],{"key":20,"text":65,"correct":22},"不接地",{"key":24,"text":67,"correct":22},"直接接地",{"key":27,"text":69,"correct":32},"经电容接地",{"key":30,"text":71,"correct":22},"经阻抗接地","ABD",{"id":74,"libraryId":5,"type":15,"typeLabel":16,"stem":75,"options":76,"answer":46,"analysis":21},422079,"电缆线主要由（ ）构成。",[77,79,81,83],{"key":20,"text":78,"correct":32},"避雷线",{"key":24,"text":80,"correct":22},"绝缘层",{"key":27,"text":82,"correct":22},"导线",{"key":30,"text":84,"correct":22},"保护层",{"id":86,"libraryId":5,"type":15,"typeLabel":16,"stem":87,"options":88,"answer":59,"analysis":21},422080,"下列措施能够提高电力系统暂态稳定性的是（ ）。",[89,91,93,95],{"key":20,"text":90,"correct":22},"快速切除故障",{"key":24,"text":92,"correct":22},"采用自动重合闸",{"key":27,"text":94,"correct":22},"强行励磁装置和电气制动措施",{"key":30,"text":96,"correct":22},"控制原动机输出的机械功率",{"id":98,"libraryId":5,"type":15,"typeLabel":16,"stem":99,"options":100,"answer":33,"analysis":21},422081,"提高电力系统静态稳定性的措施有（ ）。",[101,103,105,107],{"key":20,"text":102,"correct":22},"提高系统电压",{"key":24,"text":104,"correct":22},"采用自动励磁调节装置",{"key":27,"text":106,"correct":22},"减小元件的电抗",{"key":30,"text":92,"correct":32},{"id":109,"libraryId":5,"type":15,"typeLabel":16,"stem":110,"options":111,"answer":72,"analysis":21},422083,"下列表述正确的是（ ）。",[112,114,116,118],{"key":20,"text":113,"correct":22},"中性点不接地系统发生单相接地短路时，中性点电位升至相电压",{"key":24,"text":115,"correct":22},"中性点不接地系统发生单相接地故障时，非故障相电压升至线电压",{"key":27,"text":117,"correct":32},"两相短路不接地没有零序分量且正序和负序电流大小相等，方向相同",{"key":30,"text":119,"correct":22},"两相短路，非故障相电压等于故障前电压，故障相电压幅值降低一半",{"id":121,"libraryId":5,"type":15,"typeLabel":16,"stem":122,"options":123,"answer":132,"analysis":21},422084,"无限大电源供电情况下突然发生三相短路时，短路电流中有（ ）。",[124,126,128,130],{"key":20,"text":125,"correct":22},"基频交流",{"key":24,"text":127,"correct":32},"倍频交流",{"key":27,"text":129,"correct":22},"非周期分量",{"key":30,"text":131,"correct":32},"前三种都包含","AC",{"id":134,"libraryId":5,"type":15,"typeLabel":16,"stem":135,"options":136,"answer":59,"analysis":21},422085,"电子系统的扰动可以分为大扰动和小扰动。小扰动是指由（ ）。",[137,139,141,143],{"key":20,"text":138,"correct":22},"负荷正常波动",{"key":24,"text":140,"correct":22},"功率及潮流控制",{"key":27,"text":142,"correct":22},"变压器分接头调整",{"key":30,"text":144,"correct":22},"联络线功率自然波动",{"id":146,"libraryId":5,"type":15,"typeLabel":16,"stem":147,"options":148,"answer":33,"analysis":21},422086,"调度操作指令形式有：（ ）。",[149,151,153,155],{"key":20,"text":150,"correct":22},"单项指令",{"key":24,"text":152,"correct":22},"逐项指令",{"key":27,"text":154,"correct":22},"综合指令",{"key":30,"text":156,"correct":32},"遥控指令",{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":59,"analysis":21},422088,"关于阻尼功率系数，下列说法正确的是（ ）。",[161,163,165,167],{"key":20,"text":162,"correct":22},"快速励磁调节系统可能会产生阻尼功率系数为负的情况",{"key":24,"text":164,"correct":22},"励磁调节系统配置适当时系统不可能发生低频自发振荡",{"key":27,"text":166,"correct":22},"阻尼功率系数为正且整步功率系数为正时系统才是静态稳定的",{"key":30,"text":168,"correct":22},"一般发电机的阻尼功率系数为正",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":72,"analysis":21},422090,"降低线损的技术措施有（ ）。",[173,175,177,179],{"key":20,"text":174,"correct":22},"电网改造",{"key":24,"text":176,"correct":22},"停运空载变",{"key":27,"text":178,"correct":32},"查窃电",{"key":30,"text":180,"correct":22},"无功补偿",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":59,"analysis":21},422092,"电力系统由（ ）、用电构成。",[185,187,189,191],{"key":20,"text":186,"correct":22},"发电",{"key":24,"text":188,"correct":22},"输电",{"key":27,"text":190,"correct":22},"变电",{"key":30,"text":192,"correct":22},"配电",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":59,"analysis":21},422094,"影响架空线的零序电抗的因素有（ ）。",[197,199,201,203],{"key":20,"text":198,"correct":22},"架空线路的架设方式",{"key":24,"text":200,"correct":22},"架空线路的架设结构",{"key":27,"text":202,"correct":22},"架空线路的材料",{"key":30,"text":204,"correct":22},"架空回路有无地线",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":132,"analysis":21},422095,"无功功率的最优分布包括（ ）。",[209,211,213,215],{"key":20,"text":210,"correct":22},"无功功率电源的最优分布",{"key":24,"text":212,"correct":32},"无功功率变压器的最优分布",{"key":27,"text":214,"correct":22},"无功功率负荷的最优补偿",{"key":30,"text":216,"correct":32},"无功功率线路的最优补偿",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":229,"analysis":21},422096,"借补偿设备调压大体可分为（ ）。",[221,223,225,227],{"key":20,"text":222,"correct":22},"支路补偿",{"key":24,"text":224,"correct":22},"干路补偿",{"key":27,"text":226,"correct":32},"串联补偿",{"key":30,"text":228,"correct":32},"并联补偿","AB",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":59,"analysis":21},422098,"关于大扰动后的系统暂态过程的3个阶段，说法正确的是（ ）。",[234,236,238,240],{"key":20,"text":235,"correct":22},"起始阶段指的是故障后约1s内的时间段",{"key":24,"text":237,"correct":22},"中间阶段发电机组的调节系统已经发挥作用",{"key":27,"text":239,"correct":22},"后期阶段中动力设备将影响到电力系统的暂态过程",{"key":30,"text":241,"correct":22},"后期阶段中系统会由于频率和电压的下降自动切除部分负荷",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":253,"analysis":21},422099,"以下属于电力系统元件的是（ ）。",[246,248,250,251],{"key":20,"text":247,"correct":32},"汽轮机",{"key":24,"text":249,"correct":32},"水轮机",{"key":27,"text":41,"correct":22},{"key":30,"text":252,"correct":22},"电力变压器","CD",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":266,"analysis":21},422100,"统计线损电量包括（ ）。",[258,260,262,264],{"key":20,"text":259,"correct":22},"管理线损",{"key":24,"text":261,"correct":32},"可变损耗",{"key":27,"text":263,"correct":22},"理论线损",{"key":30,"text":265,"correct":22},"不明线损","ACD",{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":72,"analysis":21},422101,"电压\u002F无功控制是通过调整（ ），并满足全网各节点的电压要求，保证全网网损达到最少。",[271,273,275,277],{"key":20,"text":272,"correct":22},"发电机及调相机无功出力",{"key":24,"text":274,"correct":22},"各电容器组及电抗器的投切",{"key":27,"text":276,"correct":32},"电阻投入组数",{"key":30,"text":278,"correct":22},"变压器分接头位置",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":253,"analysis":21},422102,"变压器的等值电路中产生的是不变损耗的有（ ）。",[283,285,287,289],{"key":20,"text":284,"correct":32},"电阻",{"key":24,"text":286,"correct":32},"电抗",{"key":27,"text":288,"correct":22},"电导",{"key":30,"text":290,"correct":22},"电纳",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":303,"analysis":21},422103,"有下列情形的，不经批准即可对用户中止供电，但事后应报告本单位负责人。（ ）《供规》第六十六条。",[295,297,299,301],{"key":20,"text":296,"correct":22},"不可抗力和紧急避险",{"key":24,"text":298,"correct":32},"对危害供用电安全，扰乱供用电秩序，拒绝检查者",{"key":27,"text":300,"correct":32},"受电装置经检验不合格，在指定期间未改善者",{"key":30,"text":302,"correct":22},"确有窃电行为。","AD",{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":46,"analysis":21},422104,"电抗器的额定电压是6kV，额定电流时是0.3kA电抗百分数为5%，以100MVA为基准，电压取平均额定电压，其电抗标幺值错误的是（ ）。",[308,310,312,314],{"key":20,"text":309,"correct":32},"1.456",{"key":24,"text":311,"correct":22},"1.476",{"key":27,"text":313,"correct":22},"2.12",{"key":30,"text":315,"correct":22},"1.556",{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":266,"analysis":21},422105,"国家电网公司承诺，供电方案答复期限为：居民客户不超过（ ）个工作日，低压电力客户不超过（ ）个工作日，高压单电源客户不超过（ ）个工作日。",[320,322,324,326],{"key":20,"text":321,"correct":22},"3",{"key":24,"text":323,"correct":32},"5",{"key":27,"text":325,"correct":22},"7",{"key":30,"text":327,"correct":22},"15",{"id":329,"libraryId":5,"type":15,"typeLabel":16,"stem":330,"options":331,"answer":338,"analysis":21},422106,"电力网主要设备是（ ）。",[332,333,334,336],{"key":20,"text":41,"correct":32},{"key":24,"text":43,"correct":22},{"key":27,"text":335,"correct":22},"电力线路",{"key":30,"text":337,"correct":32},"用户","BC",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":46,"analysis":21},422107,"下面各项措施中，能够提高电力系统大电机并列运行暂态稳定性的有（ ）。",[343,345,346,348],{"key":20,"text":344,"correct":32},"架空线路装设避雷线",{"key":24,"text":90,"correct":22},{"key":27,"text":347,"correct":22},"采用自动重合闸装置",{"key":30,"text":349,"correct":22},"强行励磁装置",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":59,"analysis":21},422108,"电力系统可采取的限流措施有（ ）。",[354,356,357,359],{"key":20,"text":355,"correct":22},"提高电力系统的电压等级",{"key":24,"text":54,"correct":22},{"key":27,"text":358,"correct":22},"在电力系统主网加强联系后，将次级电网解环运行",{"key":30,"text":360,"correct":22},"在允许的范围内，增大系统的零序阻抗，如采用不带第三绕组或第三绕组为Y接线全星形自耦变压器，减少变压器的接地点等",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":229,"analysis":21},422110,"在变压器等值参数计算中，空载试验求的是（ ）。",[365,366,367,368],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":32},{"key":30,"text":30,"correct":32},{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":371,"answer":72,"analysis":21},422113,[372,374,376,378],{"key":20,"text":373,"correct":22},"三相短路、单相接地短路、两相短路、两相短路接地",{"key":24,"text":375,"correct":22},"单相接地短路、三相短路、两相短路、两相短路接地",{"key":27,"text":377,"correct":32},"两相接地短路、单相短路接地、两相短路、三相短路",{"key":30,"text":379,"correct":22},"两相短路接地、两相短路、单相接地短路、三相短路",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":33,"analysis":21},422114,"关于各种金属性短路情况下的边界条件方程，正确的是（ ）。",[384,385,386,387],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":32},{"id":389,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":390,"answer":266,"analysis":21},422115,[391,392,393,394],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":32},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":22},{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":397,"answer":266,"analysis":21},422116,[398,399,400,401],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":32},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":22},{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":404,"answer":72,"analysis":21},422117,[405,406,407,408],{"key":20,"text":373,"correct":22},{"key":24,"text":375,"correct":22},{"key":27,"text":377,"correct":32},{"key":30,"text":379,"correct":22},{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":411,"answer":72,"analysis":21},422118,[412,413,414,415],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":32},{"key":30,"text":30,"correct":22},{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":59,"analysis":21},422119,"500kV线路装设高压并联电抗器应考虑的条件有（ ）。",[420,422,424,426],{"key":20,"text":421,"correct":22},"在500kV电网中，正常及检修运行方式下，发生故障或任一处无故障三相跳闸时，必须采取措施限制母线侧及线路侧的过电压",{"key":24,"text":423,"correct":22},"需要采用高压并联电抗器并带中性点小电抗作为解决潜供电流的措施时",{"key":27,"text":425,"correct":22},"发电厂为无功平衡需要，而又无法装设低压电抗器时",{"key":30,"text":427,"correct":22},"系统运行操作（如同期并列）需要时",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":46,"analysis":21},422120,"既可以提高静态稳定性又可以提高暂态稳定性的是（ ）。",[432,434,436,438],{"key":20,"text":433,"correct":32},"故障的快速切除和采用重合闸措施",{"key":24,"text":435,"correct":22},"发电机强行励磁",{"key":27,"text":437,"correct":22},"线路串补电容",{"key":30,"text":439,"correct":22},"采用多回线路输电",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":46,"analysis":21},422122,"以下系统适用于P-Q分解法的有（ ）。",[444,446,448,450],{"key":20,"text":445,"correct":32},"35kV电压等级",{"key":24,"text":447,"correct":22},"110kV电压等级",{"key":27,"text":449,"correct":22},"220kV电压等级",{"key":30,"text":451,"correct":22},"500kV电压等级",{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":454,"options":455,"answer":229,"analysis":21},422124,"变压器模型中不能体现变压器电压变换功能的模型是（ ）。",[456,458,460,462],{"key":20,"text":457,"correct":22},"T形",{"key":24,"text":459,"correct":22},"Γ形",{"key":27,"text":461,"correct":32},"π形",{"key":30,"text":463,"correct":32},"这种模型不存在",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":476,"analysis":21},422125,"变压器等值电路中无功功率消耗包括（ ）。",[468,470,472,474],{"key":20,"text":469,"correct":32},"串联电阻的损耗",{"key":24,"text":471,"correct":22},"励磁（导纳）支路损耗",{"key":27,"text":473,"correct":32},"并联电导的损耗",{"key":30,"text":475,"correct":22},"绕组漏抗中无功损耗","BD",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":253,"analysis":21},422126,"变压器中性点经小电阻接地在提高电力系统并列运行暂态稳定性方面的作用是（ ）。",[481,483,485,487],{"key":20,"text":482,"correct":32},"提高电力系统在电力系统三相短路情况下的暂态稳定性",{"key":24,"text":484,"correct":32},"提高电力系统在电力系统两相短路情况下的暂态稳定性",{"key":27,"text":486,"correct":22},"提高电力系统在发生单相接地短路情况下的暂态稳定性",{"key":30,"text":488,"correct":22},"提高电力系统在两相接地短路情况下的暂态稳定性",{"id":490,"libraryId":5,"type":15,"typeLabel":16,"stem":491,"options":492,"answer":33,"analysis":21},422127,"标幺制的优点是（ ）。",[493,495,497,499],{"key":20,"text":494,"correct":22},"计算结果清晰",{"key":24,"text":496,"correct":22},"便于判断计算结果正确性",{"key":27,"text":498,"correct":22},"可大量简化计算",{"key":30,"text":500,"correct":32},"无量纲，概念不清",{"id":502,"libraryId":5,"type":15,"typeLabel":16,"stem":503,"options":504,"answer":266,"analysis":21},422128,"并联补偿可分为（ ）。",[505,507,509,511],{"key":20,"text":506,"correct":22},"并联电容器",{"key":24,"text":508,"correct":32},"并联电动机",{"key":27,"text":510,"correct":22},"并联静止补偿器",{"key":30,"text":512,"correct":22},"并联调相机",{"id":514,"libraryId":5,"type":15,"typeLabel":16,"stem":515,"options":516,"answer":33,"analysis":21},422129,"当采用制动电阻提高电力系统中同步发电机并列运行的暂态稳定性时，下述说法中正确的是（ ）。",[517,519,521,523],{"key":20,"text":518,"correct":22},"制动电阻提高电力系统并列运行暂态稳定性的原理是增加了故障情况下发电机输出的电磁功率，减小了发电机的过剩功率",{"key":24,"text":520,"correct":22},"采用串联制动时制动电阻越大，制动作用越大",{"key":27,"text":522,"correct":22},"采用并联制动时制动电阻越小，制动作用越大",{"key":30,"text":524,"correct":32},"为提高制动效果，应采用过制动方式",{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":46,"analysis":21},422130,"冲击电流不会出现在短路电流发生后（ ）。",[529,531,533,535],{"key":20,"text":530,"correct":32},"1\u002F2周期",{"key":24,"text":532,"correct":22},"1周期",{"key":27,"text":534,"correct":22},"1\u002F3周期",{"key":30,"text":536,"correct":22},"2周期",{"id":538,"libraryId":5,"type":15,"typeLabel":16,"stem":539,"options":540,"answer":33,"analysis":21},422131,"理论上线损计算的常用方法有（ ）。",[541,543,545,547],{"key":20,"text":542,"correct":22},"最大负荷损耗时间法",{"key":24,"text":544,"correct":22},"最大负荷损失因数法",{"key":27,"text":546,"correct":22},"均方根电流法",{"key":30,"text":548,"correct":32},"最小损耗法",{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":552,"answer":33,"analysis":21},422132,"理沦上线损计算的常用方法有（ ）。",[553,554,555,556],{"key":20,"text":542,"correct":22},{"key":24,"text":544,"correct":22},{"key":27,"text":546,"correct":22},{"key":30,"text":548,"correct":32},{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":303,"analysis":21},422133,"电力系统的接线图包括（ ）。",[561,563,565,567],{"key":20,"text":562,"correct":22},"电气接线图",{"key":24,"text":564,"correct":32},"架空线接线图",{"key":27,"text":566,"correct":32},"变电站接线图",{"key":30,"text":568,"correct":22},"地理接线图",{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":338,"analysis":21},422134,"关于调频厂，下列说法正确的有（ ）。",[573,575,577,579],{"key":20,"text":574,"correct":32},"频率偏移不超过±0.2Hz时，主调频厂无须调频",{"key":24,"text":576,"correct":22},"频率偏移不超过±0.2Hz时，由主调频厂调频",{"key":27,"text":578,"correct":22},"频率偏移超过±0.2Hz时，辅助调频厂也将参与调频",{"key":30,"text":580,"correct":32},"频率偏移超过±0.5Hz时，系统内所有电厂都将参与调频",{"id":582,"libraryId":5,"type":15,"typeLabel":16,"stem":583,"options":584,"answer":59,"analysis":21},422135,"短路电流的影响下列说法正确的是（ ）。",[585,587,589,591],{"key":20,"text":586,"correct":22},"短路电流是正常负荷电流的十多倍产生的热量影响设备",{"key":24,"text":588,"correct":22},"短路还会引起电网中电压降低",{"key":27,"text":590,"correct":22},"电力负荷异步电动机，它的电磁转矩与外施电压的平方成正比，转矩受影响较大",{"key":30,"text":592,"correct":22},"导体也会受到很大的电动力的冲击，致使导体变形，甚至损坏",[594,598,602,605,608,612],{"id":595,"name":596,"category":7,"favorite":597},256,"综合应用能力",6,{"id":599,"name":600,"category":7,"favorite":601},194,"《公安》基础知识+专业",5,{"id":603,"name":604,"category":7,"favorite":601},195,"政法干警",{"id":606,"name":607,"category":7,"favorite":601},255,"职业能力倾向测验",{"id":609,"name":610,"category":7,"favorite":611},212,"国家公务员-行政能力测试",4,{"id":613,"name":614,"category":7,"favorite":611},254,"公共基础知识"]