[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-197-34":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":612},{"id":5,"name":6,"category":7,"favorite":8},197,"电工类 (电网)","公务员",0,34,50,2675,[13,34,46,58,70,82,94,106,117,127,138,150,161,173,185,196,208,220,232,244,255,267,279,290,302,314,326,338,350,362,374,386,397,409,421,433,445,457,469,481,493,505,517,529,541,553,564,576,588,600],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},421786,1,"单选题","若规定功率正方向为母线流向线路，区内故障时两侧功率（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","方向相同，均与正方向一致",true,{"key":24,"text":25,"correct":26},"B","方向相同，均与正方向相反",false,{"key":28,"text":29,"correct":26},"C","方向相同，有的与正方向一致，有的不一致",{"key":31,"text":32,"correct":26},"D","方向不同，有的与正方向一致，有的不一致","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},421787,"高频保护的适用范围为（ ），是一种无时限快速原理保护。",[38,40,42,44],{"key":20,"text":39,"correct":26},"低压输电线路",{"key":24,"text":41,"correct":22},"高压和超高压输电线路",{"key":28,"text":43,"correct":26},"任何电压等级的输电线路",{"key":31,"text":45,"correct":26},"以上都不对",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},421788,"相差高频保护是比较线路两侧（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"短路电流相位",{"key":24,"text":53,"correct":26},"高频电路相位",{"key":28,"text":55,"correct":26},"负荷电流相位",{"key":31,"text":57,"correct":26},"I1+KI2的相位",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},421789,"闭锁式纵联保护跳闸的必要条件是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"正向元件动作，反向元件不动作，没有收到闭锁信号",{"key":24,"text":65,"correct":26},"正向元件动作，反向元件不动作，收到闭锁信号然后又消失",{"key":28,"text":67,"correct":22},"正反向元件均动作，没有收到闭锁信号",{"key":31,"text":69,"correct":26},"正反向元件不动作，收到闭锁信号而信号又消失",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},421790,"电力系统中发生母线和变压器发生故障，一般（ ）重合闸。",[74,76,78,80],{"key":20,"text":75,"correct":26},"必须采用",{"key":24,"text":77,"correct":22},"不采用",{"key":28,"text":79,"correct":26},"根据实际情况采用",{"key":31,"text":81,"correct":26},"不确定",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},421791,"自动重合闸按照重合闸作用断路器的方式可分为（ ）、单相重合闸和综合重合闸。",[86,88,90,92],{"key":20,"text":87,"correct":26},"一次重合闸",{"key":24,"text":89,"correct":22},"三相重合闸",{"key":28,"text":91,"correct":26},"二次重合闸",{"key":31,"text":93,"correct":26},"单侧电源重合闸",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},421792,"下列不属于“瞬时性故障”的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":26},"雷电引起的绝缘子表面闪络",{"key":24,"text":101,"correct":26},"大风引起的碰线",{"key":28,"text":103,"correct":26},"鸟类在线路上引起的短路",{"key":31,"text":105,"correct":22},"由于线路倒杆引起的故障",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},421793,"对空气断路器或者液压传动的油短路器，当气压或液压低至不允许实行重合闸时，应将重合闸（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":26},"开放保护",{"key":24,"text":113,"correct":22},"闭锁保护",{"key":28,"text":115,"correct":26},"延时动作",{"key":31,"text":45,"correct":26},{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":20,"analysis":33},421794,"重合闸后加速保护的适用范围是（ ）。",[121,123,125,126],{"key":20,"text":122,"correct":22},"35KV以上的网络及对重要负荷供电的送电线路",{"key":24,"text":124,"correct":26},"35KV及以下的发电厂或变电所的直配线路",{"key":28,"text":43,"correct":26},{"key":31,"text":45,"correct":26},{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":20,"analysis":33},421795,"当发生单相接地短路时，对综合重合闸的动作描述正确的是（ ）。",[131,133,135,137],{"key":20,"text":132,"correct":22},"跳开单相，然后进行单相重合，重合不成功则跳开三相而不再重合",{"key":24,"text":134,"correct":26},"跳开三相不再重合",{"key":28,"text":136,"correct":26},"跳开三相，重合三相",{"key":31,"text":45,"correct":26},{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":20,"analysis":33},421796,"阻抗选相元件为（ ）。",[142,144,146,148],{"key":20,"text":143,"correct":22},"低阻抗继电器",{"key":24,"text":145,"correct":26},"过阻抗继电器",{"key":28,"text":147,"correct":26},"电流互感器",{"key":31,"text":149,"correct":26},"电压互感器",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":20,"analysis":33},421797,"重合闸后加速保护的特点是（ ）。",[154,156,158,160],{"key":20,"text":155,"correct":22},"第一次动作有选择性",{"key":24,"text":157,"correct":26},"第一次动作没有选择性",{"key":28,"text":159,"correct":26},"使用设备复杂不经济",{"key":31,"text":45,"correct":26},{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":31,"analysis":33},421798,"单相自动重合闸中的选相元件应满足选择性，下列不属于其具体要求的是（ ）。",[165,167,169,171],{"key":20,"text":166,"correct":26},"发生故障时只跳开发生故障的那一相，而另外两相上的选相元件不应动作",{"key":24,"text":168,"correct":26},"只跳开与故障点相近的断路器",{"key":28,"text":170,"correct":26},"动作越快越好",{"key":31,"text":172,"correct":22},"动作越慢越好",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":31,"analysis":33},421799,"关于励磁涌流说法，错误的是（ ）。",[177,179,181,183],{"key":20,"text":178,"correct":26},"大小可达额定电流的4~8倍",{"key":24,"text":180,"correct":26},"与变压器额定容量有关",{"key":28,"text":182,"correct":26},"变压器电压突增时变压器严重饱和而产生",{"key":31,"text":184,"correct":22},"不会造成保护误动",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":28,"analysis":33},421800,"具有二次谐波制动的差动保护，为了可靠躲过励磁涌流，可以（ ）。",[189,191,193,195],{"key":20,"text":190,"correct":26},"增大“差动速断”动作电流的整定值",{"key":24,"text":192,"correct":26},"适当增大差动保护的二次谐波制动比",{"key":28,"text":194,"correct":22},"适当减小差动保护的二次谐波制动比",{"key":31,"text":45,"correct":26},{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":28,"analysis":33},421801,"对于中性点可能接地或不接地的变压器，应装设（ ）接地保护。",[200,202,204,206],{"key":20,"text":201,"correct":26},"零序电流",{"key":24,"text":203,"correct":26},"零序电压",{"key":28,"text":205,"correct":22},"零序电流和零序电压",{"key":31,"text":207,"correct":26},"距离保护",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":24,"analysis":33},421802,"关于三相变压器励磁涌流的特点，下列说法正确的是（ ）。",[212,214,216,218],{"key":20,"text":213,"correct":26},"某相励磁涌流可能不再偏离时间轴的一侧变成对称性涌流，对称性涌流的数值比较大",{"key":24,"text":215,"correct":22},"三相励磁涌流不会相同，任何情况下空载投入变压器，至少在两相中出现不同程度的励磁涌流",{"key":28,"text":217,"correct":26},"励磁涌流的波形仍然是间断的，但间断角显著增大",{"key":31,"text":219,"correct":26},"对称性涌流的间断角最大",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":20,"analysis":33},421803,"关于单相变压器励磁涌流的特点，下列说法正确的是（ ）。",[224,226,228,230],{"key":20,"text":225,"correct":22},"波形完全偏离时间轴的一侧，并出现间断",{"key":24,"text":227,"correct":26},"涌流越大，间断角越大",{"key":28,"text":229,"correct":26},"间断角越小，二次谐波越大",{"key":31,"text":231,"correct":26},"间断角越小，非周期分量越小",{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":31,"analysis":33},421804,"关于母线保护中电流互感器饱和问题，下列说法不正确的是（ ）。",[236,238,240,242],{"key":20,"text":237,"correct":26},"中阻抗母线差动保护利用TA饱和时励磁阻抗降低的特点防止差动保护误动作",{"key":24,"text":239,"correct":26},"具有制动特性的母线差动保护在TA饱和不是很严重时，比率制动特性可以保证母线差动保护不误动作",{"key":28,"text":241,"correct":26},"谐波制动原理利用了TA饱和时差电流波形畸变的特点，根据差电流中谐波分量的波形特征检测TA是否发生饱和",{"key":31,"text":243,"correct":22},"以上都不正确",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":20,"analysis":33},421805,"电流比相式母线保护的工作原理是（ ）。",[248,250,252,254],{"key":20,"text":249,"correct":22},"比较电流相位的变化",{"key":24,"text":251,"correct":26},"比较电流大小的变化",{"key":28,"text":253,"correct":26},"比较功率因数角的变化",{"key":31,"text":45,"correct":26},{"id":256,"libraryId":5,"type":15,"typeLabel":16,"stem":257,"options":258,"answer":20,"analysis":33},421806,"当发电厂采用单母线，母线上发生故障时，应由（ ）来动作跳闸。",[259,261,263,265],{"key":20,"text":260,"correct":22},"发电机的过电流保护",{"key":24,"text":262,"correct":26},"母线的过电流保护",{"key":28,"text":264,"correct":26},"母线的电流速断保护",{"key":31,"text":266,"correct":26},"母线的限时电流速断保护",{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":20,"analysis":33},421807,"完全电流差动保护中，对灵敏度系数的要求是不低于（ ）。",[271,273,275,277],{"key":20,"text":272,"correct":22},"2",{"key":24,"text":274,"correct":26},"1",{"key":28,"text":276,"correct":26},"1.5",{"key":31,"text":278,"correct":26},"1.3",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":20,"analysis":33},421808,"母线运行方式的切换对母线保护的影响是（ ）。",[283,285,287,289],{"key":20,"text":284,"correct":22},"母线运行方式变化时，母线上各种连接元件在运行中需要经常在两条母线上切换",{"key":24,"text":286,"correct":26},"母线运行方式切换时需要把保护退出",{"key":28,"text":288,"correct":26},"母线运行方式的切换会导致母线保护误动",{"key":31,"text":243,"correct":26},{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":24,"analysis":33},421809,"电气主接线设计中的灵活性要求指（ ）。",[294,296,298,300],{"key":20,"text":295,"correct":26},"调度方便，年运行损耗低，使用设备少",{"key":24,"text":297,"correct":22},"操作简便，调度方便，易于扩建",{"key":28,"text":299,"correct":26},"操作简便，结构合理，检修便捷",{"key":31,"text":301,"correct":26},"易于扩建，检修便捷，运行可靠",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":31,"analysis":33},421810,"根据对电气主接线的基本要求，设计电气主接线时首先要考虑（ ）。",[306,308,310,312],{"key":20,"text":307,"correct":26},"采用有母线的接线形式",{"key":24,"text":309,"correct":26},"采用无母线的接线形式",{"key":28,"text":311,"correct":26},"尽量降低投资、少占耕地",{"key":31,"text":313,"correct":22},"保证必要的可靠性和电能质量要求",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":31,"analysis":33},421811,"电气主接线是指（ ）。",[318,320,322,324],{"key":20,"text":319,"correct":26},"发电厂或变电所一、二次设备间的连接关系",{"key":24,"text":321,"correct":26},"发电厂或变电所重要设备的连接关系",{"key":28,"text":323,"correct":26},"发电厂或变电所的一次设备按照设计要求连接而成的电路",{"key":31,"text":325,"correct":22},"发电厂或变电所的一次设备按照运行方式要求连接而成的电路",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":31,"analysis":33},421812,"下列哪种情况宜采用一台半断路器接线（ ）。",[330,332,334,336],{"key":20,"text":331,"correct":26},"10~35KV出线回路数为10回以上",{"key":24,"text":333,"correct":26},"35~110KV出线回路数为8回以上",{"key":28,"text":335,"correct":26},"110~229KV出线回路数为6回以上",{"key":31,"text":337,"correct":22},"330~500KV出线回路数为6回以上",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":31,"analysis":33},421813,"采用双母线同时运行的双母线接线，具有单母线分段接线的特点。（ ）",[342,344,346,348],{"key":20,"text":343,"correct":26},"因此双母线接线与单母线分段接线是等效的",{"key":24,"text":345,"correct":26},"但单母线分段接线具有更大的运行灵活性",{"key":28,"text":347,"correct":26},"并且两者的设备数量一样",{"key":31,"text":349,"correct":22},"但双母线接线具有更大的运行灵活性",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":28,"analysis":33},421814,"属于有母线接线的是（ ）。",[354,356,358,360],{"key":20,"text":355,"correct":26},"桥形接线",{"key":24,"text":357,"correct":26},"角形接线",{"key":28,"text":359,"correct":22},"二分之三接线",{"key":31,"text":361,"correct":26},"单元接线",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":28,"analysis":33},421815,"下列选项中不属于多角形接线特点的是（ ）。",[366,368,370,372],{"key":20,"text":367,"correct":26},"接线简单清晰、经济性好",{"key":24,"text":369,"correct":26},"供电可靠性高、运行灵活",{"key":28,"text":371,"correct":22},"检修一台断路器时，需对有关支路停电",{"key":31,"text":373,"correct":26},"难以扩建",{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":376,"options":377,"answer":24,"analysis":33},421816,"下列选项中不属于单母线接线优点的是（ ）。",[378,380,382,384],{"key":20,"text":379,"correct":26},"便于扩建",{"key":24,"text":381,"correct":22},"可靠性高",{"key":28,"text":383,"correct":26},"接线简单",{"key":31,"text":385,"correct":26},"投资少",{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":28,"analysis":33},421817,"一台半断路器接线属于（ ）。",[390,392,393,395],{"key":20,"text":391,"correct":26},"多角形接线",{"key":24,"text":355,"correct":26},{"key":28,"text":394,"correct":22},"具有两组母线的接线",{"key":31,"text":396,"correct":26},"无母线接线",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":31,"analysis":33},421818,"导体和电器的动、热稳定以及电器的开断电流，按（ ）计算。",[401,403,405,407],{"key":20,"text":402,"correct":26},"三相导体",{"key":24,"text":404,"correct":26},"两相短路",{"key":28,"text":406,"correct":26},"单相短路",{"key":31,"text":408,"correct":22},"所用短路中最严重的情况",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":24,"analysis":33},421819,"断路器的开断时间是指从接收分闸命令瞬间起到（ ）。",[413,415,417,419],{"key":20,"text":414,"correct":26},"所有电弧触头均分离的瞬间为止",{"key":24,"text":416,"correct":22},"各级触头间电弧最终熄灭为止",{"key":28,"text":418,"correct":26},"首相触头电弧熄灭为止",{"key":31,"text":420,"correct":26},"主触头分离瞬间为止",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":24,"analysis":33},421820,"电气设备的额定电压就是铭牌上标出的（ ）。",[425,427,429,431],{"key":20,"text":426,"correct":26},"相电压",{"key":24,"text":428,"correct":22},"线电压",{"key":28,"text":430,"correct":26},"开路电压",{"key":31,"text":432,"correct":26},"短路电压",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":24,"analysis":33},421821,"选择电气设备时，应使所选电气设备最高工作电压（ ）电气设备装置点的电网最高允许电压。",[437,439,441,443],{"key":20,"text":438,"correct":26},"不高于",{"key":24,"text":440,"correct":22},"不低于",{"key":28,"text":442,"correct":26},"等于",{"key":31,"text":444,"correct":26},"无影响",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":28,"analysis":33},421822,"短路电流的计算按系统内（ ）。",[449,451,453,455],{"key":20,"text":450,"correct":26},"正常运行方式",{"key":24,"text":452,"correct":26},"最小运行方式",{"key":28,"text":454,"correct":22},"最大运行方式",{"key":31,"text":456,"correct":26},"满足负荷运行方式",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":28,"analysis":33},421823,"在下列电气设备选择中，不需要进行热稳定校验的电气设备有（ ）。",[461,463,465,467],{"key":20,"text":462,"correct":26},"断路器",{"key":24,"text":464,"correct":26},"母线",{"key":28,"text":466,"correct":22},"支撑绝缘子",{"key":31,"text":468,"correct":26},"电抗器",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":24,"analysis":33},421824,"水平排列、间距相同的三根导体，两边分别为流过A相、C相、中间B相电流。三相对称短路时，受力最大的一相为（ ）。",[473,475,477,479],{"key":20,"text":474,"correct":26},"A相",{"key":24,"text":476,"correct":22},"B相",{"key":28,"text":478,"correct":26},"C相",{"key":31,"text":480,"correct":26},"三者相同",{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":31,"analysis":33},421825,"不同故障类型，最大电动力是（ ）。",[485,487,489,491],{"key":20,"text":486,"correct":26},"单相接地短路时，线路受到的电动力",{"key":24,"text":488,"correct":26},"两相短路，线路中间相受到的电动力",{"key":28,"text":490,"correct":26},"两相接地短路时，线路中间相受到的电动力",{"key":31,"text":492,"correct":22},"三相短路接地时，线路中间相受到的电动力",{"id":494,"libraryId":5,"type":15,"typeLabel":16,"stem":495,"options":496,"answer":31,"analysis":33},421826,"短路故障通常会对设备产生（ ）主要影响。",[497,499,501,503],{"key":20,"text":498,"correct":26},"劣化、磁化",{"key":24,"text":500,"correct":26},"发热、老化",{"key":28,"text":502,"correct":26},"发热、增加接触电阻",{"key":31,"text":504,"correct":22},"发热、受力",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":24,"analysis":33},421827,"在选择仪用互感器时，电流互感器的准确级要（ ）所供测量仪表的准确级。",[509,511,513,515],{"key":20,"text":510,"correct":26},"低于",{"key":24,"text":512,"correct":22},"高于",{"key":28,"text":514,"correct":26},"略低于",{"key":31,"text":516,"correct":26},"都可以",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":28,"analysis":33},421828,"户外配电装置35KV以上软导线采用（ ）。",[521,523,525,527],{"key":20,"text":522,"correct":26},"多股铜绞线",{"key":24,"text":524,"correct":26},"多股铝绞线",{"key":28,"text":526,"correct":22},"钢芯铝绞线",{"key":31,"text":528,"correct":26},"钢芯多股绞线",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":31,"analysis":33},421829,"为提高导体的载流量，应采取措施中错误的是（ ）。",[533,535,537,539],{"key":20,"text":534,"correct":26},"采用电阻率较小的材料，如铝、铝合金等",{"key":24,"text":536,"correct":26},"改变导体的形状，增加导体散热表面积",{"key":28,"text":538,"correct":26},"导体布置采用散热效果最佳的方式",{"key":31,"text":540,"correct":22},"采用电磁屏蔽，进而降低导体发热",{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":28,"analysis":33},421830,"硬铝母线的短路时发热允许温度是（ ）℃。",[545,547,549,551],{"key":20,"text":546,"correct":26},"70",{"key":24,"text":548,"correct":26},"98",{"key":28,"text":550,"correct":22},"200",{"key":31,"text":552,"correct":26},"300",{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":24,"analysis":33},421831,"屋内配电装置220KV电压互感器接到母线上必须经（ ）。",[557,558,560,562],{"key":20,"text":462,"correct":26},{"key":24,"text":559,"correct":22},"隔离开关",{"key":28,"text":561,"correct":26},"熔断器",{"key":31,"text":563,"correct":26},"避雷器",{"id":565,"libraryId":5,"type":15,"typeLabel":16,"stem":566,"options":567,"answer":28,"analysis":33},421832,"对配电装置的基本要求不包括（ ）。",[568,570,572,574],{"key":20,"text":569,"correct":26},"运行可靠",{"key":24,"text":571,"correct":26},"便于操作、巡视和检修",{"key":28,"text":573,"correct":22},"布置美观",{"key":31,"text":575,"correct":26},"具有扩建的可能",{"id":577,"libraryId":5,"type":15,"typeLabel":16,"stem":578,"options":579,"answer":20,"analysis":33},421833,"在我国对110KV及以上的配电装置，一般（ ）。",[580,582,584,586],{"key":20,"text":581,"correct":22},"将避雷针装在构架上",{"key":24,"text":583,"correct":26},"安装独立避雷针",{"key":28,"text":585,"correct":26},"安装独立避雷线",{"key":31,"text":587,"correct":26},"安装接地线",{"id":589,"libraryId":5,"type":15,"typeLabel":16,"stem":590,"options":591,"answer":28,"analysis":33},421834,"变压器按用途可分为电力变压器、特种变压器和（ ）。",[592,594,596,598],{"key":20,"text":593,"correct":26},"干式变压器",{"key":24,"text":595,"correct":26},"自耦变压器",{"key":28,"text":597,"correct":22},"仪用互感器",{"key":31,"text":599,"correct":26},"有载调压变压器",{"id":601,"libraryId":5,"type":15,"typeLabel":16,"stem":602,"options":603,"answer":24,"analysis":33},421835,"用于两种电压等级之间交换功率的变压器称为（ ）。",[604,606,608,610],{"key":20,"text":605,"correct":26},"主变压器",{"key":24,"text":607,"correct":22},"联络变压器",{"key":28,"text":609,"correct":26},"厂用变压器",{"key":31,"text":611,"correct":26},"所用变压器",[613,617,621,624,627,631],{"id":614,"name":615,"category":7,"favorite":616},256,"综合应用能力",6,{"id":618,"name":619,"category":7,"favorite":620},194,"《公安》基础知识+专业",5,{"id":622,"name":623,"category":7,"favorite":620},195,"政法干警",{"id":625,"name":626,"category":7,"favorite":620},255,"职业能力倾向测验",{"id":628,"name":629,"category":7,"favorite":630},212,"国家公务员-行政能力测试",4,{"id":632,"name":633,"category":7,"favorite":630},254,"公共基础知识"]