[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-197-33":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":602},{"id":5,"name":6,"category":7,"favorite":8},197,"电工类 (电网)","公务员",0,33,50,2675,[13,34,46,58,70,82,94,104,116,128,140,152,164,176,188,200,212,224,236,248,260,272,283,295,307,319,330,342,353,360,372,384,396,408,420,432,443,451,462,473,485,495,507,519,531,543,555,567,579,590],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},421734,1,"单选题","分析电力系统静态稳定性的方法是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","小干扰法",true,{"key":24,"text":25,"correct":26},"B","改进欧拉法",false,{"key":28,"text":29,"correct":26},"C","运算曲线法",{"key":31,"text":32,"correct":26},"D","对称分量法","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},421735,"通过线路串联电容减小了线路电抗，发电机储备系数会有所（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"增大",{"key":24,"text":41,"correct":26},"减小",{"key":28,"text":43,"correct":26},"不变",{"key":31,"text":45,"correct":26},"不一定",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},421736,"在空载电动势保持不变的情况下，隐极机的最大电磁功率出现在（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"δ=90°",{"key":24,"text":53,"correct":26},"δ=180°",{"key":28,"text":55,"correct":26},"δ＜90°",{"key":31,"text":57,"correct":26},"δ＞90°",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},421737,"对同步发电机并列静态稳定储备系数的要求是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"正常运行时Kp（%）≥15~20，事故后运行情况下Kp（%）≥10",{"key":24,"text":65,"correct":26},"正常运行时Kp（%）≥10，事故后运行情况下Kp（%）≥20",{"key":28,"text":67,"correct":26},"正常运行时Kp（%）≥10，事故后运行情况下Kp（%）≥15~20",{"key":31,"text":69,"correct":22},"正常运行时，Kp（%）≥30，事故后运行情况下Kp（%）≥10",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},421738,"下述所给出的各个选相中，完全属于提高电力系统并列运行静态稳定性的一组是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"输电线路采用分裂导线，发电机装设先进励磁装置，提高输电电压等级",{"key":24,"text":77,"correct":26},"输电线路采用分裂导线，发电机装设先进励磁装置，输电线路装重合闸装置",{"key":28,"text":79,"correct":26},"输电线路采用分裂导线，发电机装设先进励磁装置，快速切除故障",{"key":31,"text":81,"correct":26},"快速切除故障，输电线路装重合闸装置，发电机装设先进励磁装置",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},421739,"电力系统暂态分析研究的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":26},"电力系统稳态运行",{"key":24,"text":89,"correct":22},"电磁暂态和机电暂态过程",{"key":28,"text":91,"correct":26},"电磁暂态过程和波过程",{"key":31,"text":93,"correct":26},"机电暂态过程和波过程",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},421740,"分析电力系统暂态稳定性主要应用（ ）。",[98,100,102,103],{"key":20,"text":99,"correct":26},"等耗量微增原则",{"key":24,"text":101,"correct":22},"等面积定则",{"key":28,"text":21,"correct":26},{"key":31,"text":32,"correct":26},{"id":105,"libraryId":5,"type":15,"typeLabel":16,"stem":106,"options":107,"answer":20,"analysis":33},421741,"关于等面积法则，不正确的是（ ）。",[108,110,112,114],{"key":20,"text":109,"correct":22},"可直接应用于多机电力系统中",{"key":24,"text":111,"correct":26},"最大可能的减速面积不小于加速面积，是保证暂态稳定的条件",{"key":28,"text":113,"correct":26},"应用等面积定则，可以方便地求出极限切除角",{"key":31,"text":115,"correct":26},"扩展等面积准则可用于多机系统",{"id":117,"libraryId":5,"type":15,"typeLabel":16,"stem":118,"options":119,"answer":28,"analysis":33},421743,"装于同一相变比相同且容量相同的电流互感器，在二次绕组串联使用时（ ）。",[120,122,124,126],{"key":20,"text":121,"correct":26},"容量和变比都增加一倍",{"key":24,"text":123,"correct":26},"变比增加一倍容量不变",{"key":28,"text":125,"correct":22},"变比不变，容量增加一倍",{"key":31,"text":127,"correct":26},"都不对",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":28,"analysis":33},421744,"电压互感器与电流互感器一次侧接入电力系统的方式是（ ）。",[132,134,136,138],{"key":20,"text":133,"correct":26},"串接、串接",{"key":24,"text":135,"correct":26},"并接、并接",{"key":28,"text":137,"correct":22},"并接、串接",{"key":31,"text":139,"correct":26},"串接、并接",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":28,"analysis":33},421745,"负荷功率因数低造成的影响是（ ）。",[144,146,148,150],{"key":20,"text":145,"correct":26},"线路电压损失增大",{"key":24,"text":147,"correct":26},"线路电压损失增大，有功损耗增大",{"key":28,"text":149,"correct":22},"线路电压损失增大，有功损耗增大，发电设备未能充分发挥作用",{"key":31,"text":151,"correct":26},"有功损耗增大",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":31,"analysis":33},421746,"电压互感器分为测量用电流互感器和（ ）用电流互感器",[156,158,160,162],{"key":20,"text":157,"correct":26},"实验",{"key":24,"text":159,"correct":26},"保护",{"key":28,"text":161,"correct":26},"跳闸",{"key":31,"text":163,"correct":22},"运行",{"id":165,"libraryId":5,"type":15,"typeLabel":16,"stem":166,"options":167,"answer":20,"analysis":33},421747,"（ ）可以将电力系统的一次电流按一定的变化变换成二次较小电流，供给测量表计和继电器。",[168,170,172,174],{"key":20,"text":169,"correct":22},"电流互感器",{"key":24,"text":171,"correct":26},"电压互感器",{"key":28,"text":173,"correct":26},"继电器",{"key":31,"text":175,"correct":26},"变压器",{"id":177,"libraryId":5,"type":15,"typeLabel":16,"stem":178,"options":179,"answer":20,"analysis":33},421748,"输电线路BC两相金属性短路时，短路IBC（ ）。",[180,182,184,186],{"key":20,"text":181,"correct":22},"滞后于BC相电压一线路阻抗角",{"key":24,"text":183,"correct":26},"滞后于B相电压一线路阻抗角",{"key":28,"text":185,"correct":26},"滞后于C相电压一线路阻抗角",{"key":31,"text":187,"correct":26},"滞后于A相电压一线路阻抗角",{"id":189,"libraryId":5,"type":15,"typeLabel":16,"stem":190,"options":191,"answer":20,"analysis":33},421749,"靠近线路电源端与靠近线路负荷端的定时限过流保护相比（ ）。",[192,194,196,198],{"key":20,"text":193,"correct":22},"靠近线路电源端整定值大",{"key":24,"text":195,"correct":26},"靠近线路负荷端整定值大",{"key":28,"text":197,"correct":26},"整定值相等",{"key":31,"text":199,"correct":26},"均可",{"id":201,"libraryId":5,"type":15,"typeLabel":16,"stem":202,"options":203,"answer":24,"analysis":33},421750,"继电保护后备保护逐级配合是指（ ）。",[204,206,208,210],{"key":20,"text":205,"correct":26},"时间配合",{"key":24,"text":207,"correct":22},"时间和灵敏度均配合",{"key":28,"text":209,"correct":26},"灵敏度配合",{"key":31,"text":211,"correct":26},"快速性配合",{"id":213,"libraryId":5,"type":15,"typeLabel":16,"stem":214,"options":215,"answer":28,"analysis":33},421752,"瞬时电流速断保护的主要优点是（ ）。",[216,218,220,222],{"key":20,"text":217,"correct":26},"可保护线路全长",{"key":24,"text":219,"correct":26},"可保护本线路及下级线路全长",{"key":28,"text":221,"correct":22},"动作迅速，简单可靠",{"key":31,"text":223,"correct":26},"可保护本线路及下级线路一部分",{"id":225,"libraryId":5,"type":15,"typeLabel":16,"stem":226,"options":227,"answer":24,"analysis":33},421753,"Y, d11接线的变压器低压三角形侧发生两相短路时，Y侧有一相电流比另外两相电流大，该相是。（ ）",[228,230,232,234],{"key":20,"text":229,"correct":26},"同名故障相中的超前相",{"key":24,"text":231,"correct":22},"同名故障相中的滞后相",{"key":28,"text":233,"correct":26},"非故障相",{"key":31,"text":235,"correct":26},"A相",{"id":237,"libraryId":5,"type":15,"typeLabel":16,"stem":238,"options":239,"answer":24,"analysis":33},421754,"对于反应故障时参数增大而动作的继电保护，计算继电保护灵敏性系数时应用（ ）。",[240,242,244,246],{"key":20,"text":241,"correct":26},"故障参数的最大计算值",{"key":24,"text":243,"correct":22},"故障参数的最小计算值",{"key":28,"text":245,"correct":26},"故障参数的最优解",{"key":31,"text":247,"correct":26},"三者均可",{"id":249,"libraryId":5,"type":15,"typeLabel":16,"stem":250,"options":251,"answer":28,"analysis":33},421755,"限时电流速断保护与相邻线路电流速断保护在定值上和时限上均要配合，若（ ）不满足要求，则要与相邻线路限时电流速断保护配合。",[252,254,256,258],{"key":20,"text":253,"correct":26},"选择性",{"key":24,"text":255,"correct":26},"速动性",{"key":28,"text":257,"correct":22},"灵敏性",{"key":31,"text":259,"correct":26},"可靠性",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":24,"analysis":33},421756,"当中性点采用经装设消弧线圈接地的运行方式后，如果接地故障时所提供的电感电流大于电容电流总和，则其补偿方式为（ ）。",[264,266,268,270],{"key":20,"text":265,"correct":26},"全补偿方式",{"key":24,"text":267,"correct":22},"过补偿方式",{"key":28,"text":269,"correct":26},"欠补偿方式",{"key":31,"text":271,"correct":26},"零补偿方式",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":24,"analysis":33},421757,"（ ）的出现是区分正常运行、过负荷、系统振荡及相间短路的基本特征。",[276,278,280,282],{"key":20,"text":277,"correct":26},"正序分量",{"key":24,"text":279,"correct":22},"负序分量",{"key":28,"text":281,"correct":26},"零序分量",{"key":31,"text":199,"correct":26},{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":20,"analysis":33},421758,"中性点不接地电网的单相接地故障出现较多时，为反应单相接地故障，常采用（ ）。",[287,289,291,293],{"key":20,"text":288,"correct":22},"绝缘监视装置",{"key":24,"text":290,"correct":26},"零序电流保护",{"key":28,"text":292,"correct":26},"零序功率方向保护",{"key":31,"text":294,"correct":26},"零序电压保护",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":28,"analysis":33},421759,"大电流接地系统中发生单相接地故障，故障点距母线远近与母线上零序电压值的关系是（ ）。",[299,301,303,305],{"key":20,"text":300,"correct":26},"与故障点位置无关",{"key":24,"text":302,"correct":26},"故障点越远零序电压越高",{"key":28,"text":304,"correct":22},"故障点越远零序电压越低",{"key":31,"text":306,"correct":26},"无法判断",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":20,"analysis":33},421760,"在中性点直接接地电网中，发生单相接地短路时，故障点的零序电流与零序电压的相位关系是（ ）。",[311,313,315,317],{"key":20,"text":312,"correct":22},"电流超前电压约90°",{"key":24,"text":314,"correct":26},"电压超前电流约90°",{"key":28,"text":316,"correct":26},"电流电压同相位",{"key":31,"text":318,"correct":26},"电压超前电流约180°",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":31,"analysis":33},421761,"距离保护采用三段式，分为相间距离保护和（ ）。",[323,324,326,328],{"key":20,"text":290,"correct":26},{"key":24,"text":325,"correct":26},"低电流保护",{"key":28,"text":327,"correct":26},"电流保护",{"key":31,"text":329,"correct":22},"接地距离保护",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":24,"analysis":33},421762,"距离保护是反应（ ）而动作的保护。",[334,336,338,340],{"key":20,"text":335,"correct":26},"测量阻抗增大",{"key":24,"text":337,"correct":22},"测量阻抗降低",{"key":28,"text":339,"correct":26},"电流增大",{"key":31,"text":341,"correct":26},"电压降低",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":344,"answer":24,"analysis":33},421763,[345,347,349,351],{"key":20,"text":346,"correct":26},"该相自阻抗",{"key":24,"text":348,"correct":22},"该相正序阻抗",{"key":28,"text":350,"correct":26},"该相零序阻抗",{"key":31,"text":352,"correct":26},"该相负序阻抗",{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":355,"answer":28,"analysis":33},421764,[356,357,358,359],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":361,"libraryId":5,"type":15,"typeLabel":16,"stem":362,"options":363,"answer":28,"analysis":33},421765,"当继电器刚好动作时，加入继电器中的电压和电流的比值称为继电器的（ ）。",[364,366,368,370],{"key":20,"text":365,"correct":26},"测量阻抗",{"key":24,"text":367,"correct":26},"整定阻抗",{"key":28,"text":369,"correct":22},"起动阻抗",{"key":31,"text":371,"correct":26},"零序阻抗",{"id":373,"libraryId":5,"type":15,"typeLabel":16,"stem":374,"options":375,"answer":28,"analysis":33},421766,"阻抗继电器通常采用0°接线方式，是因为（ ）。",[376,378,380,382],{"key":20,"text":377,"correct":26},"可以躲过振荡",{"key":24,"text":379,"correct":26},"可以提高阻抗继电器的灵敏性",{"key":28,"text":381,"correct":22},"在各种相间短路时，测量阻抗均ZM为Z1L",{"key":31,"text":383,"correct":26},"灵敏度高",{"id":385,"libraryId":5,"type":15,"typeLabel":16,"stem":386,"options":387,"answer":31,"analysis":33},421767,"距离保护反应保护安装处至故障点之间的（ ）。",[388,390,392,394],{"key":20,"text":389,"correct":26},"电压",{"key":24,"text":391,"correct":26},"电流",{"key":28,"text":393,"correct":26},"功率",{"key":31,"text":395,"correct":22},"阻抗",{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":20,"analysis":33},421768,"下列阻抗继电器没有方向性的是（ ）。",[400,402,404,406],{"key":20,"text":401,"correct":22},"全阻抗继电器",{"key":24,"text":403,"correct":26},"偏移阻抗继电器",{"key":28,"text":405,"correct":26},"方向阻抗继电器",{"key":31,"text":407,"correct":26},"圆特性阻抗继电器",{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":410,"options":411,"answer":24,"analysis":33},421769,"阻抗继电器的精确工作电流（ ）。",[412,414,416,418],{"key":20,"text":413,"correct":26},"大些好",{"key":24,"text":415,"correct":22},"小些好",{"key":28,"text":417,"correct":26},"为阻抗继电器的工作没有影响",{"key":31,"text":419,"correct":26},"为1A",{"id":421,"libraryId":5,"type":15,"typeLabel":16,"stem":422,"options":423,"answer":31,"analysis":33},421770,"方向阻抗继电器的最大灵敏度是可以调节的，调节方法是改变电抗继电器DKB（ ）。",[424,426,428,430],{"key":20,"text":425,"correct":26},"原边匝数",{"key":24,"text":427,"correct":26},"副边匝数",{"key":28,"text":429,"correct":26},"原边线圈中的电阻大小",{"key":31,"text":431,"correct":22},"副边线圈中的电阻大小",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":20,"analysis":33},421771,"距离三段保护，采用方向阻抗继电器比采用全阻抗继电器（ ）。",[436,437,439,441],{"key":20,"text":383,"correct":22},{"key":24,"text":438,"correct":26},"灵敏度低",{"key":28,"text":440,"correct":26},"灵敏度一样",{"key":31,"text":442,"correct":26},"保护范围小",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":24,"analysis":33},421772,"阻抗继电器的精确工作电流是指（ ）。",[447,448,449,450],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":24,"analysis":33},421773,"当系统频率高于定额频率时，方向阻抗继电器最大灵敏度（ ）。",[455,457,459,460],{"key":20,"text":456,"correct":26},"变大",{"key":24,"text":458,"correct":22},"变小",{"key":28,"text":43,"correct":26},{"key":31,"text":461,"correct":26},"与系统频率变化无关",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":24,"analysis":33},421774,"三种圆特性阻抗原件中（ ）元件的动作阻抗与测量阻抗的阻抗角无关。",[466,468,470,471],{"key":20,"text":467,"correct":26},"方向阻抗",{"key":24,"text":469,"correct":22},"全阻抗",{"key":28,"text":405,"correct":26},{"key":31,"text":472,"correct":26},"圆特效阻抗",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":24,"analysis":33},421775,"相间短路的电阻主要是电弧电阻，其特点是随时间而变化，在短路初始瞬间，其值（ ）。",[477,479,481,483],{"key":20,"text":478,"correct":26},"最大",{"key":24,"text":480,"correct":22},"最小",{"key":28,"text":482,"correct":26},"介于最大最小之间",{"key":31,"text":484,"correct":26},"不确定",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":24,"analysis":33},421776,"从减少系统振荡的影响出发，距离保护的测量元件应采用（ ）。",[489,490,491,493],{"key":20,"text":401,"correct":26},{"key":24,"text":405,"correct":22},{"key":28,"text":492,"correct":26},"偏移特性阻抗继电器",{"key":31,"text":494,"correct":26},"圆阻抗继电器",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":24,"analysis":33},421777,"单侧电源供电系统短路中的过渡电阻对距离保护的影响是（ ）。",[499,501,503,505],{"key":20,"text":500,"correct":26},"使保护范围伸长",{"key":24,"text":502,"correct":22},"使保护范围缩短",{"key":28,"text":504,"correct":26},"保护范围不变",{"key":31,"text":506,"correct":26},"保护范围不定",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":24,"analysis":33},421778,"当系统发生振荡时，距离III段保护不受振荡影响，其原因是（ ）。",[511,513,515,517],{"key":20,"text":512,"correct":26},"保护动作时限小于系统的振荡周期",{"key":24,"text":514,"correct":22},"保护动作时限大于系统的振荡周期",{"key":28,"text":516,"correct":26},"保护动作时限等于系统的振荡周期",{"key":31,"text":518,"correct":26},"以上都不对",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":521,"options":522,"answer":24,"analysis":33},421779,"能切除线路区内任意一点故障的主保护（ ）。",[523,525,527,529],{"key":20,"text":524,"correct":26},"相间保护",{"key":24,"text":526,"correct":22},"纵联保护",{"key":28,"text":528,"correct":26},"零序保护",{"key":31,"text":530,"correct":26},"接地距离",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":20,"analysis":33},421780,"电流互感器为了保证精确性，经常采用的是（ ）。",[535,537,539,541],{"key":20,"text":536,"correct":22},"10%误差曲线",{"key":24,"text":538,"correct":26},"20%误差曲线",{"key":28,"text":540,"correct":26},"磁化曲线",{"key":31,"text":542,"correct":26},"伏安特性曲线",{"id":544,"libraryId":5,"type":15,"typeLabel":16,"stem":545,"options":546,"answer":20,"analysis":33},421781,"纵差动保护不能适用于输电线路的原因是（ ）。",[547,549,551,553],{"key":20,"text":548,"correct":22},"不经济",{"key":24,"text":550,"correct":26},"不满足灵敏性要求",{"key":28,"text":552,"correct":26},"不能保护线路全长",{"key":31,"text":554,"correct":26},"灵敏性不高",{"id":556,"libraryId":5,"type":15,"typeLabel":16,"stem":557,"options":558,"answer":28,"analysis":33},421782,"纵联保护电力线路载波通道用（ ）方式来传送被保护线路两侧的比较信号。",[559,561,563,565],{"key":20,"text":560,"correct":26},"卫星传输",{"key":24,"text":562,"correct":26},"微波通道",{"key":28,"text":564,"correct":22},"相一地高频通道",{"key":31,"text":566,"correct":26},"电话线路",{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":24,"analysis":33},421783,"下面哪种高频保护在电压二次回路断线时可不退出工作（ ）。",[571,573,575,577],{"key":20,"text":572,"correct":26},"高频闭锁距离保护",{"key":24,"text":574,"correct":22},"相差高频保护",{"key":28,"text":576,"correct":26},"高频闭锁负序方向保护",{"key":31,"text":578,"correct":26},"以上均可",{"id":580,"libraryId":5,"type":15,"typeLabel":16,"stem":581,"options":582,"answer":24,"analysis":33},421784,"结合电容器的作用是（ ）。",[583,585,587,589],{"key":20,"text":584,"correct":26},"限制高频信号通过",{"key":24,"text":586,"correct":22},"限制低频信号通过",{"key":28,"text":588,"correct":26},"限制短路电流通过",{"key":31,"text":518,"correct":26},{"id":591,"libraryId":5,"type":15,"typeLabel":16,"stem":592,"options":593,"answer":20,"analysis":33},421785,"高频保护使用的频率，最低的是（ ）。",[594,596,598,600],{"key":20,"text":595,"correct":22},"50KHz",{"key":24,"text":597,"correct":26},"50Hz",{"key":28,"text":599,"correct":26},"100KHz",{"key":31,"text":601,"correct":26},"500Hz",[603,607,611,614,617,621],{"id":604,"name":605,"category":7,"favorite":606},256,"综合应用能力",6,{"id":608,"name":609,"category":7,"favorite":610},194,"《公安》基础知识+专业",5,{"id":612,"name":613,"category":7,"favorite":610},195,"政法干警",{"id":615,"name":616,"category":7,"favorite":610},255,"职业能力倾向测验",{"id":618,"name":619,"category":7,"favorite":620},212,"国家公务员-行政能力测试",4,{"id":622,"name":623,"category":7,"favorite":620},254,"公共基础知识"]