[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-197-32":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":575},{"id":5,"name":6,"category":7,"favorite":8},197,"电工类 (电网)","公务员",0,32,50,2675,[13,34,46,58,70,80,92,104,116,128,140,152,164,176,188,200,210,218,230,242,254,266,278,290,302,313,325,337,349,361,373,385,397,405,416,428,436,444,452,464,472,480,488,499,509,520,532,543,555,567],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},421683,1,"单选题","负荷在预计值附近随机变动的概率分布属于（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","正态分布",true,{"key":24,"text":25,"correct":26},"B","泊松分布",false,{"key":28,"text":29,"correct":26},"C","t分布",{"key":31,"text":32,"correct":26},"D","F分布","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},421684,"负荷备用一般为最大负荷的（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"2%~5%",{"key":24,"text":41,"correct":26},"4%~5%",{"key":28,"text":43,"correct":26},"5%~7%",{"key":31,"text":45,"correct":26},"5%~10%",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},421685,"（ ）指的是未运转的发电设备可能发的最大功率。",[50,52,54,56],{"key":20,"text":51,"correct":26},"热备用",{"key":24,"text":53,"correct":22},"冷备用",{"key":28,"text":55,"correct":26},"负荷备用",{"key":31,"text":57,"correct":26},"事故备用",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},421686,"要保证良好的频率质量，（ ）必须保持平衡。",[62,64,66,68],{"key":20,"text":63,"correct":22},"有功功率",{"key":24,"text":65,"correct":26},"无功功率",{"key":28,"text":67,"correct":26},"视在功率",{"key":31,"text":69,"correct":26},"波形质量",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},421687,"当发电设备发生偶然性事故时，为维持系统正常供电，频率不受影响，这种备用是（ ）。",[74,75,76,78],{"key":20,"text":55,"correct":26},{"key":24,"text":57,"correct":22},{"key":28,"text":77,"correct":26},"检修备用",{"key":31,"text":79,"correct":26},"国民经济备用",{"id":81,"libraryId":5,"type":15,"typeLabel":16,"stem":82,"options":83,"answer":28,"analysis":33},421688,"电力系统中有功功率的流向是（ ）。",[84,86,88,90],{"key":20,"text":85,"correct":26},"从电压高的节点流向电压低的节点",{"key":24,"text":87,"correct":26},"从电压低的节点流向电压高的节点",{"key":28,"text":89,"correct":22},"从相位超前的节点流向相位滞后的节点",{"key":31,"text":91,"correct":26},"从相位滞后的节点流向相位超前的节点",{"id":93,"libraryId":5,"type":15,"typeLabel":16,"stem":94,"options":95,"answer":20,"analysis":33},421689,"进行有功功率和频率的三次调整时，依据的是（ ）。",[96,98,100,102],{"key":20,"text":97,"correct":22},"有功功率日负荷曲线",{"key":24,"text":99,"correct":26},"有功功率月负荷曲线",{"key":28,"text":101,"correct":26},"有功功率季负荷曲线",{"key":31,"text":103,"correct":26},"有功功率年负荷曲线",{"id":105,"libraryId":5,"type":15,"typeLabel":16,"stem":106,"options":107,"answer":28,"analysis":33},421690,"有功功率负荷的变动一般分为三种，可预计的是（ ）。",[108,110,112,114],{"key":20,"text":109,"correct":26},"第一种",{"key":24,"text":111,"correct":26},"第二种",{"key":28,"text":113,"correct":22},"第三种",{"key":31,"text":115,"correct":26},"第四种",{"id":117,"libraryId":5,"type":15,"typeLabel":16,"stem":118,"options":119,"answer":24,"analysis":33},421691,"电力系统频率调整的基本原理是（ ）。",[120,122,124,126],{"key":20,"text":121,"correct":26},"根据负荷的变化，调整电力系统中无功电源的出力，将系统频率限制在允许的范围内",{"key":24,"text":123,"correct":22},"根据负荷的变化，调整发电机的有功出力，将系统频率限制在允许的范围内",{"key":28,"text":125,"correct":26},"根据系统频率的边哈，切除或投入负荷，将电力系统频率限制在允许范围之内",{"key":31,"text":127,"correct":26},"根据负荷的变化调整系统中变压器的分接头，将电力系统频率限制在允许范围之内",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":24,"analysis":33},421692,"我国工频电压为（ ）。",[132,134,136,138],{"key":20,"text":133,"correct":26},"25 Hz",{"key":24,"text":135,"correct":22},"50 Hz",{"key":28,"text":137,"correct":26},"60 Hz",{"key":31,"text":139,"correct":26},"220 Hz",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":28,"analysis":33},421693,"调差系数与机组的单位调节功率之间是（ ）关系。",[144,146,148,150],{"key":20,"text":145,"correct":26},"标幺值相同",{"key":24,"text":147,"correct":26},"相反数",{"key":28,"text":149,"correct":22},"倒数",{"key":31,"text":151,"correct":26},"负导数",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":20,"analysis":33},421694,"一般情况下，水电厂的可调容量（ ）火电厂。",[156,158,160,162],{"key":20,"text":157,"correct":22},"大于",{"key":24,"text":159,"correct":26},"小于",{"key":28,"text":161,"correct":26},"等于",{"key":31,"text":163,"correct":26},"以上情况都有可能",{"id":165,"libraryId":5,"type":15,"typeLabel":16,"stem":166,"options":167,"answer":31,"analysis":33},421695,"在系统运行中，调频厂最好由（ ）担任。",[168,170,172,174],{"key":20,"text":169,"correct":26},"核电厂",{"key":24,"text":171,"correct":26},"热电厂",{"key":28,"text":173,"correct":26},"高效率机组电厂",{"key":31,"text":175,"correct":22},"非洪水季节的水电厂",{"id":177,"libraryId":5,"type":15,"typeLabel":16,"stem":178,"options":179,"answer":24,"analysis":33},421696,"在无功电源并不缺乏的电力系统中，关于是否需要增加无功补偿装置，下列说法正确的是（ ）。",[180,182,184,186],{"key":20,"text":181,"correct":26},"绝对不应增加无功补偿设备",{"key":24,"text":183,"correct":22},"可以增加无功补偿设备，但应遵循最优网损微增率准则",{"key":28,"text":185,"correct":26},"可以增加无功补偿设备，但应遵循等网损微增率准则",{"key":31,"text":187,"correct":26},"应增加无功补偿设备，知道各节点的网损微增率均为正值为止",{"id":189,"libraryId":5,"type":15,"typeLabel":16,"stem":190,"options":191,"answer":28,"analysis":33},421697,"电力系统无功过剩时，会造成（ ）。",[192,194,196,198],{"key":20,"text":193,"correct":26},"频率升高",{"key":24,"text":195,"correct":26},"频率降低",{"key":28,"text":197,"correct":22},"电压升高",{"key":31,"text":199,"correct":26},"电压降低",{"id":201,"libraryId":5,"type":15,"typeLabel":16,"stem":202,"options":203,"answer":24,"analysis":33},421698,"“无损耗线路”，且负荷功率因数为1，当输送的有功功率小于自然功率时，线路消耗的是（ ）无功功率。",[204,206,208],{"key":20,"text":205,"correct":26},"感性",{"key":24,"text":207,"correct":22},"容性",{"key":28,"text":209,"correct":26},"不确定",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":24,"analysis":33},421699,"设n台相同的变压器并列运行，变压器运行电压为U（KV），通过的功率为S（MVA），n台变压器总无功损耗为（ ）。",[214,215,216,217],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":20,"analysis":33},421700,"逆调压是指（ ）。",[222,224,226,228],{"key":20,"text":223,"correct":22},"高峰负荷，将电压中枢点电压升高，低谷负荷时将其降低",{"key":24,"text":225,"correct":26},"高峰负荷，将电压中枢点电压降低，低谷负荷时将其升高",{"key":28,"text":227,"correct":26},"高峰负荷和低峰负荷时将其降低",{"key":31,"text":229,"correct":26},"高峰负荷和低峰负荷时将其升高",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":28,"analysis":33},421701,"对于有功电源过盛，但无功不足引起的电压水平偏低的电力系统，应优先采用的调压措施是（ ）。",[234,236,238,240],{"key":20,"text":235,"correct":26},"改变无励磁调节变压器变比",{"key":24,"text":237,"correct":26},"增加无功补偿装置",{"key":28,"text":239,"correct":22},"改变发电机无功出力",{"key":31,"text":241,"correct":26},"减少无功补偿装置",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":24,"analysis":33},421702,"利用发电机调压（ ）。",[246,248,250,252],{"key":20,"text":247,"correct":26},"需要附加设备",{"key":24,"text":249,"correct":22},"不需要附加设备",{"key":28,"text":251,"correct":26},"某些时候需要附加设备",{"key":31,"text":253,"correct":26},"某些时候不需要附加设备",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":28,"analysis":33},421703,"同步发电机电枢反应性质取决于（ ）。",[258,260,262,264],{"key":20,"text":259,"correct":26},"负载性质",{"key":24,"text":261,"correct":26},"发电机本身参数",{"key":28,"text":263,"correct":22},"负载性质和发电机本身参数",{"key":31,"text":265,"correct":26},"负载大小",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":20,"analysis":33},421704,"短路故障引起电力网络中电压降低，靠近短路点降的（ ）。",[270,272,274,276],{"key":20,"text":271,"correct":22},"多",{"key":24,"text":273,"correct":26},"少",{"key":28,"text":275,"correct":26},"电压不受短路点位置的影响",{"key":31,"text":277,"correct":26},"以上答案都不对",{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":280,"options":281,"answer":20,"analysis":33},421705,"运用运算曲线法计算任意时刻短路电流周期分量有效值时，对于负荷的处理方法是（ ）。",[282,284,286,288],{"key":20,"text":283,"correct":22},"不考虑负荷的影响",{"key":24,"text":285,"correct":26},"需要考虑负荷的影响",{"key":28,"text":287,"correct":26},"仅需要考虑短路点附近大容量电动机的影响",{"key":31,"text":289,"correct":26},"需要部分考虑负荷的影响",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":31,"analysis":33},421706,"冲击电流出现的时间为（ ）。",[294,296,298,300],{"key":20,"text":295,"correct":26},"0.2 s",{"key":24,"text":297,"correct":26},"0.02 s",{"key":28,"text":299,"correct":26},"0.1 s",{"key":31,"text":301,"correct":22},"0.01 s",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":304,"answer":24,"analysis":33},421707,[305,307,309,311],{"key":20,"text":306,"correct":26},"三相短路",{"key":24,"text":308,"correct":22},"两相短路",{"key":28,"text":310,"correct":26},"两相短路接地",{"key":31,"text":312,"correct":26},"单相接地短路",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":20,"analysis":33},421708,"无限大功率电源供电的三相对称系统，发生三相短路，短路电流的非周期分量的衰减速度（ ）。",[317,319,321,323],{"key":20,"text":318,"correct":22},"ABC三相相同",{"key":24,"text":320,"correct":26},"只有BC两相相同",{"key":28,"text":322,"correct":26},"只有AB两相相同",{"key":31,"text":324,"correct":26},"只有AC两相相同",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":28,"analysis":33},421709,"电力系统高压短路电流计算采用（ ）。",[329,331,333,335],{"key":20,"text":330,"correct":26},"有名值法",{"key":24,"text":332,"correct":26},"对称分量法",{"key":28,"text":334,"correct":22},"标幺值法",{"key":31,"text":336,"correct":26},"运算曲线法",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":31,"analysis":33},421710,"短路冲击电流是指短路电流的（ ）。",[341,343,345,347],{"key":20,"text":342,"correct":26},"有效值",{"key":24,"text":344,"correct":26},"平均值",{"key":28,"text":346,"correct":26},"方均根值",{"key":31,"text":348,"correct":22},"最大可能瞬时值",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":31,"analysis":33},421711,"根据对称量法，各相电流的正序分量与其零序分量的相位关系为（ ）。",[353,355,357,359],{"key":20,"text":354,"correct":26},"超前120°",{"key":24,"text":356,"correct":26},"滞后120°",{"key":28,"text":358,"correct":26},"同相位",{"key":31,"text":360,"correct":22},"尚难确定",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":24,"analysis":33},421712,"利用对称量法分析计算电力系统不对称故障时，应选（ ）作为分析计算的基本相。",[365,367,369,371],{"key":20,"text":366,"correct":26},"故障相",{"key":24,"text":368,"correct":22},"特殊相",{"key":28,"text":370,"correct":26},"A相",{"key":31,"text":372,"correct":26},"B相",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":31,"analysis":33},421713,"对称分量法各序分量具有独立性，则此电路应为（ ）。",[377,379,381,383],{"key":20,"text":378,"correct":26},"非线性、参数对称",{"key":24,"text":380,"correct":26},"线性、参数不对称",{"key":28,"text":382,"correct":26},"非线性、参数不对称",{"key":31,"text":384,"correct":22},"线性、参数对称",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":24,"analysis":33},421714,"越靠近短路点，负序电压的有效值（ ）。",[389,391,393,395],{"key":20,"text":390,"correct":26},"不变",{"key":24,"text":392,"correct":22},"越高",{"key":28,"text":394,"correct":26},"越低",{"key":31,"text":396,"correct":26},"不受影响",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":20,"analysis":33},421715,"Y0\u002Fd接线变压器的零序电抗为（ ）。",[401,402,403,404],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":24,"analysis":33},421716,"架空输电线路导线之间的几何平均距离越大，其正序电抗（负序电抗）越大，零序电抗（ ）。",[409,411,413,414],{"key":20,"text":410,"correct":26},"变大",{"key":24,"text":412,"correct":22},"变小",{"key":28,"text":390,"correct":26},{"key":31,"text":415,"correct":26},"以上都不对",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":24,"analysis":33},421717,"对于三相三柱式变压器，其正序参数、负序参数和零序参数的关系是（ ）。",[420,422,424,426],{"key":20,"text":421,"correct":26},"正序参数、负序参数和零序参数均相同",{"key":24,"text":423,"correct":22},"正序参数与负序参数相同，零序参数不同",{"key":28,"text":425,"correct":26},"正序参数、负序参数、零序参数各不相同",{"key":31,"text":427,"correct":26},"负序参数与零序参数相同，正序参数不同",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":20,"analysis":33},421718,"同步发电机的零序电抗 （ ）。",[432,433,434,435],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":20,"analysis":33},421719,"实用计算中，取同步发电机的负序电抗为（ ）。",[440,441,442,443],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":24,"analysis":33},421720,"越靠近短路点，零序电压的有效值（ ）。",[448,449,450,451],{"key":20,"text":390,"correct":26},{"key":24,"text":392,"correct":22},{"key":28,"text":394,"correct":26},{"key":31,"text":396,"correct":26},{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":454,"options":455,"answer":31,"analysis":33},421721,"异步电动机三相绕组通常接成△或Y不接地型，异步电动机的零序电抗（ ）。",[456,458,460,462],{"key":20,"text":457,"correct":26},"x（0）≈0",{"key":24,"text":459,"correct":26},"x（0）≈x",{"key":28,"text":461,"correct":26},"x（0）≈1\u002FIst",{"key":31,"text":463,"correct":22},"x（0）≈∞",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":28,"analysis":33},421722,"两相短路接地的边界条件是（ ）。",[468,469,470,471],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":24,"analysis":33},421723,"两相短路的边界条件是（ ）。",[476,477,478,479],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":28,"analysis":33},421724,"中性点不直接接地系统，发生单相短路故障，非故障相电压上升为（ ）。",[484,485,486,487],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":31,"analysis":33},421725,"对于两相短路接地的不对称短路，短路电流和正序电流的关系是（ ）。",[492,494,496,498],{"key":20,"text":493,"correct":26},"1.732倍",{"key":24,"text":495,"correct":26},"3倍",{"key":28,"text":497,"correct":26},"2倍",{"key":31,"text":33,"correct":22},{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":24,"analysis":33},421726,"当同步发电机供给纯电容性负荷时，电枢反应的作用是使其端电压（ ）。",[503,504,506,508],{"key":20,"text":390,"correct":26},{"key":24,"text":505,"correct":22},"增加",{"key":28,"text":507,"correct":26},"降低",{"key":31,"text":209,"correct":26},{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":20,"analysis":33},421727,"定子绕组短路电流的直流分量形成的磁场固定不变，在旋转的转子绕组中产生了（ ）。",[513,515,517,519],{"key":20,"text":514,"correct":22},"交流分量的电流",{"key":24,"text":516,"correct":26},"直流分量的电流",{"key":28,"text":518,"correct":26},"倍频分量的电流",{"key":31,"text":415,"correct":26},{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":24,"analysis":33},421728,"为简化同步发电机三相短路的分析计算，采用了一些假设条件，下面各组条件中属于同步发电机三相短路分析假设条件的一组是（ ）。",[524,526,528,530],{"key":20,"text":525,"correct":26},"发电机绕组阻抗为零、发电机频率保持不变",{"key":24,"text":527,"correct":22},"发电机磁路不饱和、发电机频率保持不变",{"key":28,"text":529,"correct":26},"发电机绕组阻抗为零、发电机磁路不饱和",{"key":31,"text":531,"correct":26},"发电机绕组电阻为零、发电机磁路已饱和",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":20,"analysis":33},421729,"同步发电机在过励时从电网吸收（ ）。",[536,538,540,541],{"key":20,"text":537,"correct":22},"容性功率",{"key":24,"text":539,"correct":26},"感性功率",{"key":28,"text":63,"correct":26},{"key":31,"text":542,"correct":26},"容性和感性功率",{"id":544,"libraryId":5,"type":15,"typeLabel":16,"stem":545,"options":546,"answer":31,"analysis":33},421730,"关于提高系统静态稳定性，下列说法正确的是（ ）。",[547,549,551,553],{"key":20,"text":548,"correct":26},"采用自动重合闸装置增加了减速面积，减小了加速面积",{"key":24,"text":550,"correct":26},"变压器中性点接小电阻可以提高系统静态稳定性",{"key":28,"text":552,"correct":26},"串补电容越大越好",{"key":31,"text":554,"correct":22},"系统具有足够的无功容量时有利于提高系统静态稳定性",{"id":556,"libraryId":5,"type":15,"typeLabel":16,"stem":557,"options":558,"answer":20,"analysis":33},421731,"系统参数在某一平均值附近做微小变化时，系统状态变量在某组平均值附近微小波动，此时电力系统运行状态属于（ ）。",[559,561,563,565],{"key":20,"text":560,"correct":22},"稳定运行",{"key":24,"text":562,"correct":26},"电磁暂态过程",{"key":28,"text":564,"correct":26},"机电暂态过程",{"key":31,"text":566,"correct":26},"波过程",{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":20,"analysis":33},421732,"判断同步发电机并列运行静态稳定性的实用判据是（ ）。",[571,572,573,574],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},[576,580,584,587,590,594],{"id":577,"name":578,"category":7,"favorite":579},256,"综合应用能力",6,{"id":581,"name":582,"category":7,"favorite":583},194,"《公安》基础知识+专业",5,{"id":585,"name":586,"category":7,"favorite":583},195,"政法干警",{"id":588,"name":589,"category":7,"favorite":583},255,"职业能力倾向测验",{"id":591,"name":592,"category":7,"favorite":593},212,"国家公务员-行政能力测试",4,{"id":595,"name":596,"category":7,"favorite":593},254,"公共基础知识"]