[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-197-31":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":579},{"id":5,"name":6,"category":7,"favorite":8},197,"电工类 (电网)","公务员",0,31,50,2675,[13,33,44,56,68,80,92,104,116,128,140,152,164,176,186,198,210,222,234,246,258,266,278,290,302,314,326,338,350,362,374,381,389,401,412,424,431,438,450,460,472,484,496,508,516,524,532,543,555,567],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":17},421632,1,"单选题","",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","U=US?R×I",false,{"key":24,"text":25,"correct":26},"B","U=US+R×I",true,{"key":28,"text":29,"correct":22},"C","U=?US?R×I",{"key":31,"text":32,"correct":22},"D","U=?US+R×I",{"id":34,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":35,"answer":28,"analysis":17},421633,[36,38,40,42],{"key":20,"text":37,"correct":22},"a点为高电位，电流由a至b",{"key":24,"text":39,"correct":22},"a点为高电位，电流由b至a",{"key":28,"text":41,"correct":26},"b点为高电位，电流由a至b",{"key":31,"text":43,"correct":22},"b点为高电位，电流由b至a",{"id":45,"libraryId":5,"type":15,"typeLabel":16,"stem":46,"options":47,"answer":24,"analysis":17},421634,"电压电流的关联参考方向是指电压、电流（ ）一致。",[48,50,52,54],{"key":20,"text":49,"correct":22},"实际方向",{"key":24,"text":51,"correct":26},"参考方向",{"key":28,"text":53,"correct":22},"电位降方向",{"key":31,"text":55,"correct":22},"电压升方向",{"id":57,"libraryId":5,"type":15,"typeLabel":16,"stem":58,"options":59,"answer":20,"analysis":17},421635,"衡量电力系统运行经济性的主要指标是（ ）。",[60,62,64,66],{"key":20,"text":61,"correct":26},"燃料耗损率、厂用电率、网损率",{"key":24,"text":63,"correct":22},"燃料耗损率、建设投资、网损率",{"key":28,"text":65,"correct":22},"网损率、建设投资、电压畸变率",{"key":31,"text":67,"correct":22},"网损率、占地面积、建设投资",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":28,"analysis":17},421636,"电网谐波的产生，主要因电力系统中存在（ ）。",[72,74,76,78],{"key":20,"text":73,"correct":22},"电感元件",{"key":24,"text":75,"correct":22},"三相参数不对称",{"key":28,"text":77,"correct":26},"非线性元件",{"key":31,"text":79,"correct":22},"电容元件",{"id":81,"libraryId":5,"type":15,"typeLabel":16,"stem":82,"options":83,"answer":24,"analysis":17},421637,"以高压甚至超高压将发电厂、变电所连接起来的送电网络称为（ ）。",[84,86,88,90],{"key":20,"text":85,"correct":22},"发电网",{"key":24,"text":87,"correct":26},"输电网",{"key":28,"text":89,"correct":22},"配电网",{"key":31,"text":91,"correct":22},"以上都对",{"id":93,"libraryId":5,"type":15,"typeLabel":16,"stem":94,"options":95,"answer":24,"analysis":17},421638,"构成电力网的主要设备有（ ）。",[96,98,100,102],{"key":20,"text":97,"correct":22},"变压器、用电设备",{"key":24,"text":99,"correct":26},"变压器、电力线路",{"key":28,"text":101,"correct":22},"电缆、架空线",{"key":31,"text":103,"correct":22},"电阻、电容",{"id":105,"libraryId":5,"type":15,"typeLabel":16,"stem":106,"options":107,"answer":31,"analysis":17},421639,"线损是指电能从发电厂到用户的输送过程中不可避免地发生（ ）的损失。",[108,110,112,114],{"key":20,"text":109,"correct":22},"电压",{"key":24,"text":111,"correct":22},"电流",{"key":28,"text":113,"correct":22},"电阻",{"key":31,"text":115,"correct":26},"功率和能量",{"id":117,"libraryId":5,"type":15,"typeLabel":16,"stem":118,"options":119,"answer":20,"analysis":17},421640,"10 KV三相供电电压允许偏差为额定电压的（ ）。",[120,122,124,126],{"key":20,"text":121,"correct":26},"±7%",{"key":24,"text":123,"correct":22},"±10%",{"key":28,"text":125,"correct":22},"+7%，?10%",{"key":31,"text":127,"correct":22},"+10%，?7%",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":28,"analysis":17},421641,"一般来说，在我国，高压电网的电压等级是（ ）。",[132,134,136,138],{"key":20,"text":133,"correct":22},"1 KV以下",{"key":24,"text":135,"correct":22},"1~35 KV",{"key":28,"text":137,"correct":26},"35 KV~330 KV",{"key":31,"text":139,"correct":22},"330~1000 KV",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":28,"analysis":17},421642,"220 KV降为110 KV的降压变压器，两侧均与线路相连，则变比为（ ）。",[144,146,148,150],{"key":20,"text":145,"correct":22},"220\u002F110",{"key":24,"text":147,"correct":22},"242\u002F110",{"key":28,"text":149,"correct":26},"220\u002F121",{"key":31,"text":151,"correct":22},"242\u002F121",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":24,"analysis":17},421643,"将一台220 KV电压降为35 KV的降压变压器联接两个网络，两侧均与线路相连，这台变压器的额定变比为（ ）。",[156,158,160,162],{"key":20,"text":157,"correct":22},"220\u002F35",{"key":24,"text":159,"correct":26},"220\u002F38.5",{"key":28,"text":161,"correct":22},"242\u002F35",{"key":31,"text":163,"correct":22},"242\u002F38.5",{"id":165,"libraryId":5,"type":15,"typeLabel":16,"stem":166,"options":167,"answer":24,"analysis":17},421644,"发电机作为电源一般将额定电压提高（ ）以补偿输电过程的电压损耗。",[168,170,172,174],{"key":20,"text":169,"correct":22},"3%",{"key":24,"text":171,"correct":26},"5%",{"key":28,"text":173,"correct":22},"10%",{"key":31,"text":175,"correct":22},"±5%",{"id":177,"libraryId":5,"type":15,"typeLabel":16,"stem":178,"options":179,"answer":28,"analysis":17},421645,"电力网某两条线路的额定电压为UN=110 KV，则它表示的是（ ）。",[180,182,183,185],{"key":20,"text":181,"correct":22},"相电压",{"key":24,"text":181,"correct":22},{"key":28,"text":184,"correct":26},"线电压",{"key":31,"text":184,"correct":22},{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":20,"analysis":17},421646,"500 KV系统的平均额定电压为（ ）。",[190,192,194,196],{"key":20,"text":191,"correct":26},"525 KV",{"key":24,"text":193,"correct":22},"520 KV",{"key":28,"text":195,"correct":22},"515 KV",{"key":31,"text":197,"correct":22},"500 KV",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":31,"analysis":17},421647,"关于各种电压等级在输配电网络中的应用，下列说法错误的是（ ）。",[202,204,206,208],{"key":20,"text":203,"correct":22},"交流500 KV通常用于区域电力系统的输电网络",{"key":24,"text":205,"correct":22},"交流220 KV通常用于地方电力系统的输电网络",{"key":28,"text":207,"correct":22},"交流35 KV及以下电压等级通常用于配电网络",{"key":31,"text":209,"correct":26},"除10 KV等级用于配电网络外，10 KV以上的电压等级都只用于输电网络",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":20,"analysis":17},421648,"中线点不直接接地系统是（ ）。",[214,216,218,220],{"key":20,"text":215,"correct":26},"35 KV及以下",{"key":24,"text":217,"correct":22},"35 KV及以上",{"key":28,"text":219,"correct":22},"110 KV及以下",{"key":31,"text":221,"correct":22},"110 KV及以上",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":20,"analysis":17},421650,"110 KV及以上的电力系统应采用中性点运行方式是（ ）。",[226,228,230,232],{"key":20,"text":227,"correct":26},"直接接地",{"key":24,"text":229,"correct":22},"不接地",{"key":28,"text":231,"correct":22},"经消弧线圈接地",{"key":31,"text":233,"correct":22},"不接地或经过消弧线圈接地",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":24,"analysis":17},421651,"中性点直接接地的运行方式适用于（ ）。",[238,240,242,244],{"key":20,"text":239,"correct":22},"60 KV及以下系统",{"key":24,"text":241,"correct":26},"110 KV及以上系统",{"key":28,"text":243,"correct":22},"35 KV及以下系统",{"key":31,"text":245,"correct":22},"35~60 KV",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":31,"analysis":17},421652,"变压器中性点经小电阻接地的主要目的是（ ）。",[250,252,254,256],{"key":20,"text":251,"correct":22},"调整电压",{"key":24,"text":253,"correct":22},"调整频率",{"key":28,"text":255,"correct":22},"调控潮流",{"key":31,"text":257,"correct":26},"电气制动",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":24,"analysis":17},421653,"变压器的电纳参数BT是由试验数据（ ）计算得出的。",[262,263,264,265],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":24,"analysis":17},421654,"关于变压器，下列说法错误的是（ ）。",[270,272,274,276],{"key":20,"text":271,"correct":22},"对电压进行变换，升压满足大容量远距离输电，降压满足用电需求",{"key":24,"text":273,"correct":26},"变压器不仅可以对电压大小进行调整，也可以对功率大小进行变换",{"key":28,"text":275,"correct":22},"当发电厂升压变压器原边绕组与发电机直接相连时，原边绕组的额定电压与发电机的额定电压相同",{"key":31,"text":277,"correct":22},"变压器的副边绕组额定电压一般应为用电设备额定电压的1.1倍",{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":280,"options":281,"answer":24,"analysis":17},421655,"将一台双绕组升压变压器作降压变压器使用，假设高压侧实际运行电压不变，其降压侧实际电压与使用升压变压器相比（ ）。",[282,284,286,288],{"key":20,"text":283,"correct":22},"不变",{"key":24,"text":285,"correct":26},"升高",{"key":28,"text":287,"correct":22},"降低",{"key":31,"text":289,"correct":22},"以上都有可能",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":31,"analysis":17},421656,"电力系统的等值模型中变压器模型（ ）。",[294,296,298,300],{"key":20,"text":295,"correct":22},"由它的端电压和输出功率来表示",{"key":24,"text":297,"correct":22},"由一个恒功率或负荷电压静态特性表示",{"key":28,"text":299,"correct":22},"是一个分布参数的电路，可用一个集中参数的Π形等值电路表示",{"key":31,"text":301,"correct":26},"通常用集中参数的Г形等值电路表示",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":31,"analysis":17},421657,"当负荷阻抗为波阻抗时，该负荷所消耗的功率称为（ ）。",[306,308,310,312],{"key":20,"text":307,"correct":22},"有功功率",{"key":24,"text":309,"correct":22},"无功功率",{"key":28,"text":311,"correct":22},"视在功率",{"key":31,"text":313,"correct":26},"自然功率",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":24,"analysis":17},421658,"中等长度的线路指架空线的长度在（ ）。",[318,320,322,324],{"key":20,"text":319,"correct":22},"不超过100 Km",{"key":24,"text":321,"correct":26},"100~300 Km",{"key":28,"text":323,"correct":22},"300~500 Km",{"key":31,"text":325,"correct":22},"超过500 Km",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":24,"analysis":17},421659,"500 KV超高压输电线路两端装设并联电抗器的目的是（ ）。",[330,332,334,336],{"key":20,"text":331,"correct":22},"防止输电线路重载时末端电压降低",{"key":24,"text":333,"correct":26},"防止输电线路轻载时末端电压升高",{"key":28,"text":335,"correct":22},"防止输电线路轻载时末端电压降低",{"key":31,"text":337,"correct":22},"防止输电线路重载时末端电压升高",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":31,"analysis":17},421660,"电力线路按结构分为两类，分别是（ ）。",[342,344,346,348],{"key":20,"text":343,"correct":22},"避雷线和架空线路",{"key":24,"text":345,"correct":22},"地线和架空线路",{"key":28,"text":347,"correct":22},"地线和电缆线路",{"key":31,"text":349,"correct":26},"架空线路和电缆线路",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":20,"analysis":17},421661,"110 KV及以上电力系统中，架空输电线路全线架设避雷线的目的是（ ）。",[354,356,358,360],{"key":20,"text":355,"correct":26},"减少线路雷击事故，提高供电质量",{"key":24,"text":357,"correct":22},"减少雷击事故，提高电能质量",{"key":28,"text":359,"correct":22},"减少雷击事故，降低输电线路对地电压",{"key":31,"text":361,"correct":22},"减少雷击事故，提高输电线路的耐压水平",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":20,"analysis":17},421662,"使用分裂导线的主要目的是（ ）。",[366,368,370,372],{"key":20,"text":367,"correct":26},"提高输电能力",{"key":24,"text":369,"correct":22},"增加线路电抗",{"key":28,"text":371,"correct":22},"减小线路导纳",{"key":31,"text":373,"correct":22},"提高电晕临界值",{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":376,"answer":20,"analysis":17},421663,[377,378,379,380],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":24,"analysis":17},421664,"在进行短路电流计算时采用标幺值计算电抗器的公式为（ ）。",[385,386,387,388],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":28,"analysis":17},421665,"对于多电压级网络，都需要将参数或变量归算至同一电压级--基本级。通常取网络中（ ）为基本级。",[393,395,397,399],{"key":20,"text":394,"correct":22},"最低电压级",{"key":24,"text":396,"correct":22},"中间电压级",{"key":28,"text":398,"correct":26},"最高电压级",{"key":31,"text":400,"correct":22},"一级电压",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":403,"answer":20,"analysis":17},421666,[404,406,408,410],{"key":20,"text":405,"correct":26},"0.453",{"key":24,"text":407,"correct":22},"1",{"key":28,"text":409,"correct":22},"0.54",{"key":31,"text":411,"correct":22},"0.263",{"id":413,"libraryId":5,"type":15,"typeLabel":16,"stem":414,"options":415,"answer":24,"analysis":17},421667,"三相短路电流计算中采用标幺值计算，只需选定两个基准，常选的是（ ）。",[416,418,420,422],{"key":20,"text":417,"correct":22},"电压、电流",{"key":24,"text":419,"correct":26},"电压、容量",{"key":28,"text":421,"correct":22},"电压、电路",{"key":31,"text":423,"correct":22},"电流、电抗",{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":426,"answer":31,"analysis":17},421668,[427,428,429,430],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":433,"answer":20,"analysis":17},421669,[434,435,436,437],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":31,"analysis":17},421670,"不属于调整控制潮流的手段是（ ）。",[442,444,446,448],{"key":20,"text":443,"correct":22},"串联电容",{"key":24,"text":445,"correct":22},"串联电抗",{"key":28,"text":447,"correct":22},"附加串联加压器",{"key":31,"text":449,"correct":26},"串联电阻",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":31,"analysis":17},421671,"某线路首端电压10.5 KV，末端电压10.2 KV，首端电压偏移百分数为（ ）。",[454,456,458,459],{"key":20,"text":455,"correct":22},"2.86%",{"key":24,"text":457,"correct":22},"2.94%",{"key":28,"text":169,"correct":22},{"key":31,"text":171,"correct":26},{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":20,"analysis":17},421672,"35 KV及以上系统允许的电压偏移为（ ）。",[464,466,468,470],{"key":20,"text":465,"correct":26},"?5%~+5%",{"key":24,"text":467,"correct":22},"?7%~+7%",{"key":28,"text":469,"correct":22},"?10%~+5%",{"key":31,"text":471,"correct":22},"?10%~+7.5%",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":31,"analysis":17},421673,"线路首端电压一定（ ）末端电压。",[476,478,480,482],{"key":20,"text":477,"correct":22},"高于",{"key":24,"text":479,"correct":22},"低于",{"key":28,"text":481,"correct":22},"等于",{"key":31,"text":483,"correct":26},"以上皆有可能",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":31,"analysis":17},421674,"潮流方程是（ ）。",[488,490,492,494],{"key":20,"text":489,"correct":22},"微分方程",{"key":24,"text":491,"correct":22},"微分方程组",{"key":28,"text":493,"correct":22},"代数方程",{"key":31,"text":495,"correct":26},"代数方程组",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":24,"analysis":17},421675,"调整控制潮流的手段中串联电抗的作用是（ ）。",[500,502,504,506],{"key":20,"text":501,"correct":22},"抵偿线路的感抗",{"key":24,"text":503,"correct":26},"限流",{"key":28,"text":505,"correct":22},"产生一环流或强制循环功率",{"key":31,"text":507,"correct":22},"限压",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":24,"analysis":17},421676,"用功率和阻抗表示的电压降落横分量的表达式为（ ）。",[512,513,514,515],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":518,"options":519,"answer":20,"analysis":17},421677,"电压损耗公式正确的是（ ）。",[520,521,522,523],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":526,"answer":20,"analysis":17},421678,[527,528,529,530],{"key":20,"text":477,"correct":26},{"key":24,"text":479,"correct":22},{"key":28,"text":481,"correct":22},{"key":31,"text":531,"correct":22},"不能确定",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":28,"analysis":17},421679,"n个节点的电力系统，PQ节点的数目为m，平衡节点的数目为（ ）。",[536,538,540,541],{"key":20,"text":537,"correct":22},"n-m-1",{"key":24,"text":539,"correct":22},"n-m-2",{"key":28,"text":407,"correct":26},{"key":31,"text":542,"correct":22},"可能为0",{"id":544,"libraryId":5,"type":15,"typeLabel":16,"stem":545,"options":546,"answer":24,"analysis":17},421680,"有一定的无功功率电源的变电所母线可以看作（ ）。",[547,549,551,553],{"key":20,"text":548,"correct":22},"PQ节点",{"key":24,"text":550,"correct":26},"PV节点",{"key":28,"text":552,"correct":22},"QV节点",{"key":31,"text":554,"correct":22},"平衡节点",{"id":556,"libraryId":5,"type":15,"typeLabel":16,"stem":557,"options":558,"answer":20,"analysis":17},421681,"原网络节点增加一接地支路，节点导纳矩阵如何变化（ ）。",[559,561,563,565],{"key":20,"text":560,"correct":26},"节点导纳矩阵阶数不变，只有自导纳Yii发生变化",{"key":24,"text":562,"correct":22},"节点导纳矩阵阶数不变，互导纳、自导纳发生变化",{"key":28,"text":564,"correct":22},"节点导纳矩阵也增加一阶",{"key":31,"text":566,"correct":22},"节点导纳矩阵减少一阶",{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":24,"analysis":17},421682,"节点导纳矩阵是（ ）。",[571,573,575,577],{"key":20,"text":572,"correct":22},"对称的满阵",{"key":24,"text":574,"correct":26},"对称的系数矩阵",{"key":28,"text":576,"correct":22},"不对称的满阵",{"key":31,"text":578,"correct":22},"不对称的稀疏矩阵",[580,584,588,591,594,598],{"id":581,"name":582,"category":7,"favorite":583},256,"综合应用能力",6,{"id":585,"name":586,"category":7,"favorite":587},194,"《公安》基础知识+专业",5,{"id":589,"name":590,"category":7,"favorite":587},195,"政法干警",{"id":592,"name":593,"category":7,"favorite":587},255,"职业能力倾向测验",{"id":595,"name":596,"category":7,"favorite":597},212,"国家公务员-行政能力测试",4,{"id":599,"name":600,"category":7,"favorite":597},254,"公共基础知识"]