[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-197-20":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":584},{"id":5,"name":6,"category":7,"favorite":8},197,"电工类 (电网)","公务员",0,20,50,2675,[13,31,41,51,61,74,86,98,110,121,133,145,155,165,175,185,195,207,219,231,240,251,263,275,284,296,308,320,332,344,355,367,379,391,403,415,427,439,451,463,475,487,499,511,523,535,547,554,562,574],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":30},421028,1,"单选题","故障点零序综合阻抗大于正序综合阻抗时，与两相接地短路故障时的零序电流相比，单相接地故障的零序电流（ ）",[19,23,27],{"key":20,"text":21,"correct":22},"A","越大",true,{"key":24,"text":25,"correct":26},"B","越小",false,{"key":28,"text":29,"correct":26},"C","大小相同","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":20,"analysis":30},421029,"在一台Y\u002F△－11接线的变压器低压侧发生AB相两相短路，星形侧某相电流为其它两相短路电流的两倍，该相为：（ ）",[35,37,39],{"key":20,"text":36,"correct":22},"A相",{"key":24,"text":38,"correct":26},"B相",{"key":28,"text":40,"correct":26},"C相",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":28,"analysis":30},421030,"同期继电器是反应母线电压和线路电压的（ ）",[45,47,49],{"key":20,"text":46,"correct":26},"幅值之差",{"key":24,"text":48,"correct":26},"相位之差",{"key":28,"text":50,"correct":22},"矢量之差",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":24,"analysis":30},421031,"高频闭锁零序距离保护中，保护停信需带一短延时，这是为了（ ）",[55,57,59],{"key":20,"text":56,"correct":26},"防止外部故障时的暂态过程而误动；",{"key":24,"text":58,"correct":22},"等待对端闭锁信号到来，防止区外故障误动；",{"key":28,"text":60,"correct":26},"防止外部故障时功率倒向而误动；",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":20,"analysis":30},421032,"如果系统在遭受到外部扰动后，系统运行指标变化很大以致于不能保证对负荷的正常供电，则此时系统（ ）。",[65,67,69,71],{"key":20,"text":66,"correct":22},"不稳定",{"key":24,"text":68,"correct":26},"暂态稳定",{"key":28,"text":70,"correct":26},"稳态稳定",{"key":72,"text":73,"correct":26},"D","波动",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":28,"analysis":30},421033,"电力系统不对称短路包括几种短路类型（ ）。",[78,80,82,84],{"key":20,"text":79,"correct":26},"5",{"key":24,"text":81,"correct":26},"2",{"key":28,"text":83,"correct":22},"3",{"key":72,"text":85,"correct":26},"4",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":24,"analysis":30},421034,"分析电力系统暂态稳定主要应用（ ）。",[90,92,94,96],{"key":20,"text":91,"correct":26},"等耗量微增率原则",{"key":24,"text":93,"correct":22},"等面积原则",{"key":28,"text":95,"correct":26},"小干扰法",{"key":72,"text":97,"correct":26},"对称分量法",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":28,"analysis":30},421035,"对于两相接地短路其序网的连接是（ ）。",[102,104,106,108],{"key":20,"text":103,"correct":26},"正序和负序并联",{"key":24,"text":105,"correct":26},"正序负序零序串联",{"key":28,"text":107,"correct":22},"正序负序零序并联",{"key":72,"text":109,"correct":26},"正序负序并联再和零序串联",{"id":111,"libraryId":5,"type":15,"typeLabel":16,"stem":112,"options":113,"answer":20,"analysis":30},421036,"大于扰后，提高原动机出力的主要目的是为了提高系统的（ ）。",[114,115,117,119],{"key":20,"text":68,"correct":22},{"key":24,"text":116,"correct":26},"静态稳定",{"key":28,"text":118,"correct":26},"电压稳定",{"key":72,"text":120,"correct":26},"经济性",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":28,"analysis":30},421037,"某变电站电压互感器的开口三角形侧B相接反，则正常运行时，如一次侧运行电压为110KV，开口三角形的输出为（ ）",[125,127,129,131],{"key":20,"text":126,"correct":26},"0V",{"key":24,"text":128,"correct":26},"100V",{"key":28,"text":130,"correct":22},"200V",{"key":72,"text":132,"correct":26},"220V",{"id":134,"libraryId":5,"type":15,"typeLabel":16,"stem":135,"options":136,"answer":72,"analysis":30},421038,"故障点过渡电阻对距离保护的影响（ ）。",[137,139,141,143],{"key":20,"text":138,"correct":26},"对长线路大",{"key":24,"text":140,"correct":26},"对短线路大",{"key":28,"text":142,"correct":26},"与线路长度无关",{"key":72,"text":144,"correct":22},"一样",{"id":146,"libraryId":5,"type":15,"typeLabel":16,"stem":147,"options":148,"answer":28,"analysis":30},421039,"母线差动保护采用电压闭锁元件的主要目的：（ ）",[149,151,153],{"key":20,"text":150,"correct":26},"系统发生振荡时，母线差动保护不会误动；",{"key":24,"text":152,"correct":26},"区外发生故障时，母线差动保护不会误动；",{"key":28,"text":154,"correct":22},"由于误碰出口继电器而不至造成母线差动保护误动；",{"id":156,"libraryId":5,"type":15,"typeLabel":16,"stem":157,"options":158,"answer":20,"analysis":30},421040,"某一线路与两条平行线相邻，其距离保护正方向在相邻平行线中点故障时不会动作，在相邻平行线末端故障时（ ）",[159,161,163],{"key":20,"text":160,"correct":22},"可能动可能不动",{"key":24,"text":162,"correct":26},"能动",{"key":28,"text":164,"correct":26},"不动",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":24,"analysis":30},421041,"在区外故障时，阻抗继电器因过渡电阻影响发生超越现象，此时阻抗继电器的测量阻抗因过渡电阻影响而增加的附加分量是（ ）",[169,171,173],{"key":20,"text":170,"correct":26},"电阻性",{"key":24,"text":172,"correct":22},"电容性",{"key":28,"text":174,"correct":26},"电感性",{"id":176,"libraryId":5,"type":15,"typeLabel":16,"stem":177,"options":178,"answer":28,"analysis":30},421042,"在大电流接地系统中发生接地短路时，保护安装点的3U0和3I0之间的相位角取决于（ ）",[179,181,183],{"key":20,"text":180,"correct":26},"该点到故障点的线路零序阻抗角；",{"key":24,"text":182,"correct":26},"该点正方向到零序网络中性点之间的零序阻抗角；",{"key":28,"text":184,"correct":22},"该点背后到零序网络中性点之间的零序阻抗角；",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":24,"analysis":30},421043,"在母差保护中，中间变流器的误差要求，应比主电流互感器严格，一般要求误差电流不超过最大区外故障电流的（ ）",[189,191,193],{"key":20,"text":190,"correct":26},"3％",{"key":24,"text":192,"correct":22},"5%",{"key":28,"text":194,"correct":26},"10%",{"id":196,"libraryId":5,"type":15,"typeLabel":16,"stem":197,"options":198,"answer":24,"analysis":30},421044,"谐波制动的变压器差动保护中，设置差动速断元件的主要原因是（ ）。",[199,201,203,205],{"key":20,"text":200,"correct":26},"为了提高差动保护的速度",{"key":24,"text":202,"correct":22},"为了防止在区内故障较高短路电流水平时，由于电流互感器饱和产生的高次谐波量而导致差动保护元件误动",{"key":28,"text":204,"correct":26},"保护装置的双重化，互为备用",{"key":72,"text":206,"correct":26},"以上都不对",{"id":208,"libraryId":5,"type":15,"typeLabel":16,"stem":209,"options":210,"answer":20,"analysis":30},421045,"具有相同的保护范围的全阻抗继电器、方向阻抗继电器、偏移园阻抗继电器、四边形方向阻抗继电器，受系统振荡影响最大的是（ ）",[211,213,215,217],{"key":20,"text":212,"correct":22},"全阻抗继电器",{"key":24,"text":214,"correct":26},"方向阻抗继电器",{"key":28,"text":216,"correct":26},"偏移园阻抗继电器",{"key":72,"text":218,"correct":26},"四边形方向阻抗继电器",{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":221,"options":222,"answer":28,"analysis":30},421048,"对于500kV线路，一般悬挂瓷绝缘子的片数为（ ）。",[223,225,227,229],{"key":20,"text":224,"correct":26},"24",{"key":24,"text":226,"correct":26},"26",{"key":28,"text":228,"correct":22},"28",{"key":72,"text":230,"correct":26},"30",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":24,"analysis":30},421049,"水平排列、间距相同的三根导体，两边分别为流过A相、C相，中间B相电流。三相对称短路时，受力最大的一相为（ ）。",[235,236,237,238],{"key":20,"text":36,"correct":26},{"key":24,"text":38,"correct":22},{"key":28,"text":40,"correct":26},{"key":72,"text":239,"correct":26},"三者相同",{"id":241,"libraryId":5,"type":15,"typeLabel":16,"stem":242,"options":243,"answer":72,"analysis":30},421050,"SF6气体灭弧能力比空气大（ ）倍。",[244,245,247,249],{"key":20,"text":230,"correct":26},{"key":24,"text":246,"correct":26},"50",{"key":28,"text":248,"correct":26},"80",{"key":72,"text":250,"correct":22},"100",{"id":252,"libraryId":5,"type":15,"typeLabel":16,"stem":253,"options":254,"answer":72,"analysis":30},421051,"为保证发电厂厂用低压单个或成组电动机可靠启动，要求厂用母线电压不低于额定电压的（ ）。",[255,257,259,261],{"key":20,"text":256,"correct":26},"50%",{"key":24,"text":258,"correct":26},"60%",{"key":28,"text":260,"correct":26},"70%",{"key":72,"text":262,"correct":22},"80%",{"id":264,"libraryId":5,"type":15,"typeLabel":16,"stem":265,"options":266,"answer":20,"analysis":30},421052,"能断开正常工作电流和故障电流的开关电器是（ ）。",[267,269,271,273],{"key":20,"text":268,"correct":22},"断路器",{"key":24,"text":270,"correct":26},"隔离开关",{"key":28,"text":272,"correct":26},"负荷开关",{"key":72,"text":274,"correct":26},"熔断器",{"id":276,"libraryId":5,"type":15,"typeLabel":16,"stem":277,"options":278,"answer":24,"analysis":30},421054,"屋内配电装置220kV电压互感器接到母线上必须经（ ）。",[279,280,281,282],{"key":20,"text":268,"correct":26},{"key":24,"text":270,"correct":22},{"key":28,"text":274,"correct":26},{"key":72,"text":283,"correct":26},"避雷器",{"id":285,"libraryId":5,"type":15,"typeLabel":16,"stem":286,"options":287,"answer":20,"analysis":30},421055,"下列哪种接线方式是无母线接线中最简单的形式，也是所有主接线基本形式中最简单的一种（ ）。",[288,290,292,294],{"key":20,"text":289,"correct":22},"单元接线",{"key":24,"text":291,"correct":26},"桥形接线",{"key":28,"text":293,"correct":26},"多角形接线",{"key":72,"text":295,"correct":26},"二分之三接线",{"id":297,"libraryId":5,"type":15,"typeLabel":16,"stem":298,"options":299,"answer":72,"analysis":30},421056,"三相电动力计算公式中的形状系数K，决定于（ ）。",[300,302,304,306],{"key":20,"text":301,"correct":26},"导体的机械强度",{"key":24,"text":303,"correct":26},"导体的形状",{"key":28,"text":305,"correct":26},"导体的布置位置",{"key":72,"text":307,"correct":22},"导体的形状及相对位置",{"id":309,"libraryId":5,"type":15,"typeLabel":16,"stem":310,"options":311,"answer":20,"analysis":30},421057,"火电厂相对于其他发电厂的优点是（ ）。",[312,314,316,318],{"key":20,"text":313,"correct":22},"布局灵活",{"key":24,"text":315,"correct":26},"效率高",{"key":28,"text":317,"correct":26},"启停快",{"key":72,"text":319,"correct":26},"污染小",{"id":321,"libraryId":5,"type":15,"typeLabel":16,"stem":322,"options":323,"answer":28,"analysis":30},421061,"户外配电装置35kV以上软导线采用（ ）。",[324,326,328,330],{"key":20,"text":325,"correct":26},"多股铜绞线",{"key":24,"text":327,"correct":26},"多股铝绞线",{"key":28,"text":329,"correct":22},"钢芯铝绞线",{"key":72,"text":331,"correct":26},"钢芯多股绞线",{"id":333,"libraryId":5,"type":15,"typeLabel":16,"stem":334,"options":335,"answer":24,"analysis":30},421062,"两台变压器并联运行，空载时二次绕组中有一定大小的循环电流，其原因是（ ）。",[336,338,340,342],{"key":20,"text":337,"correct":26},"短路电压不相等",{"key":24,"text":339,"correct":22},"变比不相等",{"key":28,"text":341,"correct":26},"连接组别不同",{"key":72,"text":343,"correct":26},"容量不相等",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":20,"analysis":30},421063,"单母线接线在检修母线隔离开关时，（ ）。",[348,350,352,354],{"key":20,"text":349,"correct":22},"必须断开全部电源",{"key":24,"text":351,"correct":26},"必须断开部分电源",{"key":28,"text":353,"correct":26},"只断开要检修的隔离开关",{"key":72,"text":206,"correct":26},{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":20,"analysis":30},421065,"自耦变压器处于联合运行方式，且高压侧同时向中压侧和低压侧送电时，其绕组的负荷分布特点为（ ）",[359,361,363,365],{"key":20,"text":360,"correct":22},"串联绕组负荷较大",{"key":24,"text":362,"correct":26},"公共绕组负荷较大",{"key":28,"text":364,"correct":26},"一次侧绕组负荷较大",{"key":72,"text":366,"correct":26},"二次侧绕组负荷较大",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":24,"analysis":30},421068,"电气设备额定电流的选择条件是它的值要大于等于（ ）。",[371,373,375,377],{"key":20,"text":372,"correct":26},"短路时最大工作电流",{"key":24,"text":374,"correct":22},"最大持续工作电流",{"key":28,"text":376,"correct":26},"最大短路电流",{"key":72,"text":378,"correct":26},"持续短路电流",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":20,"analysis":30},421069,"为保证断路器具有足够的合闸速度，操纵机构必须具有（ ）。",[383,385,387,389],{"key":20,"text":384,"correct":22},"足够大的操作功",{"key":24,"text":386,"correct":26},"较高的可靠性",{"key":28,"text":388,"correct":26},"自由脱扣装置",{"key":72,"text":390,"correct":26},"视情况而定",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":20,"analysis":30},421070,"在110kV及以上中性点直接接地系统中，凡需选用三绕组变压器的场合，均可优先选用（ ）。",[395,397,399,401],{"key":20,"text":396,"correct":22},"自耦变压器",{"key":24,"text":398,"correct":26},"普通变压器",{"key":28,"text":400,"correct":26},"分裂绕组变压器",{"key":72,"text":402,"correct":26},"三相变压器组",{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":405,"options":406,"answer":20,"analysis":30},421073,"低压分裂绕组变压器的特点是（ ）。",[407,409,411,413],{"key":20,"text":408,"correct":22},"正常运行时穿越电抗小，短路时半穿越电抗、分裂电抗大",{"key":24,"text":410,"correct":26},"正常运行时分裂电抗小，短路时半穿越电抗、穿越电抗大",{"key":28,"text":412,"correct":26},"正常运行时半穿越电抗小，短路时穿越电抗、分裂电抗大",{"key":72,"text":414,"correct":26},"正常和短路时，分裂电抗、半穿越电抗、穿越电抗都很大",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":72,"analysis":30},421074,"联络变压器的台数（ ）。",[419,421,423,425],{"key":20,"text":420,"correct":26},"一般设为3台",{"key":24,"text":422,"correct":26},"一般设为5台",{"key":28,"text":424,"correct":26},"一般设为4台",{"key":72,"text":426,"correct":22},"一般设为1台，最多不超过2台",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":28,"analysis":30},421076,"既能发电，又能储存能量的是（ ）。",[431,433,435,437],{"key":20,"text":432,"correct":26},"火电厂",{"key":24,"text":434,"correct":26},"水电厂",{"key":28,"text":436,"correct":22},"抽水蓄能电厂",{"key":72,"text":438,"correct":26},"核电厂",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":28,"analysis":30},421078,"关于电磁式电流互感器的描述正确的是（ ）。",[443,445,447,449],{"key":20,"text":444,"correct":26},"二次侧电流由二次侧负载决定，与被测电路负载电流无关",{"key":24,"text":446,"correct":26},"二次侧电流由二次侧电路结构和一次侧电流共同决定",{"key":28,"text":448,"correct":22},"二次侧电流大小和二次回路负载无关，仅由一次侧电流决定",{"key":72,"text":450,"correct":26},"二次侧电流大小决定一次侧电流大小，故二次侧负载阻抗大小决定一次侧电流",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":28,"analysis":30},421080,"三绕组变压器的分接头是装在（ ）。",[455,457,459,461],{"key":20,"text":456,"correct":26},"高压绕组",{"key":24,"text":458,"correct":26},"高压绕组和低压绕组",{"key":28,"text":460,"correct":22},"高压绕组和中压绕组",{"key":72,"text":462,"correct":26},"中压绕组和低压绕组",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":24,"analysis":30},421081,"导体长期工作允许电流值的确定通常来自导体（ ）性态。",[467,469,471,473],{"key":20,"text":468,"correct":26},"机械强度",{"key":24,"text":470,"correct":22},"发热与散热能力",{"key":28,"text":472,"correct":26},"老化周期",{"key":72,"text":474,"correct":26},"抗腐蚀能力",{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":72,"analysis":30},421082,"多台变压器在并联运行时（ ）。",[479,481,483,485],{"key":20,"text":480,"correct":26},"容量较大的变压器首先满载",{"key":24,"text":482,"correct":26},"容量较小的变压器首先满载",{"key":28,"text":484,"correct":26},"短路阻抗百分数大的变压器首先满载",{"key":72,"text":486,"correct":22},"短路阻抗百分数小的变压器首先满载",{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":24,"analysis":30},421083,"三相导体短路的最大电动力不受（ ）影响。",[491,493,495,497],{"key":20,"text":492,"correct":26},"跨距",{"key":24,"text":494,"correct":22},"长期允许电流",{"key":28,"text":496,"correct":26},"相间距离",{"key":72,"text":498,"correct":26},"三相短路时的冲击电流",{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":24,"analysis":30},421084,"在二分之三接线中（ ）。",[503,505,507,509],{"key":20,"text":504,"correct":26},"仅用隔离开关进行倒闸操作，容易发生操作事故",{"key":24,"text":506,"correct":22},"隔离开关仅起电气隔离作用，误操作的可能性小",{"key":28,"text":508,"correct":26},"检修任何隔离开关，用户可不停电",{"key":72,"text":510,"correct":26},"检修任何隔离开关，用户都要停电",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":28,"analysis":30},421087,"变压器的额定容量是指（ ）。",[515,517,519,521],{"key":20,"text":516,"correct":26},"一、二次侧容量之和",{"key":24,"text":518,"correct":26},"二次绕组的额定电压和额定电流的乘积所决定的有功功率",{"key":28,"text":520,"correct":22},"二次绕组的额定电压和额定电流的乘积所决定的视在功率",{"key":72,"text":522,"correct":26},"一、二次侧容量之和的平均值",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":28,"analysis":30},421089,"SFPSZ型变压器冷却方式为（ ）。",[527,529,531,533],{"key":20,"text":528,"correct":26},"自然冷却",{"key":24,"text":530,"correct":26},"风吹冷却",{"key":28,"text":532,"correct":22},"强迫油循环风冷",{"key":72,"text":534,"correct":26},"水冷",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":28,"analysis":30},421090,"高压断路器的额定开断电流是指在规定条件下开断（ ）。",[539,541,543,545],{"key":20,"text":540,"correct":26},"最大短路电流最大值",{"key":24,"text":542,"correct":26},"最大冲击",{"key":28,"text":544,"correct":22},"最大短路电流有效值",{"key":72,"text":546,"correct":26},"负荷电流的2倍",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":549,"answer":72,"analysis":30},421091,[550,551,552,553],{"key":20,"text":301,"correct":26},{"key":24,"text":303,"correct":26},{"key":28,"text":305,"correct":26},{"key":72,"text":307,"correct":22},{"id":555,"libraryId":5,"type":15,"typeLabel":16,"stem":556,"options":557,"answer":28,"analysis":30},421092,"电磁式电流互感器的描述正确的是（ ）。",[558,559,560,561],{"key":20,"text":444,"correct":26},{"key":24,"text":446,"correct":26},{"key":28,"text":448,"correct":22},{"key":72,"text":450,"correct":26},{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":28,"analysis":30},421093,"采用特殊金属材料作灭弧触头的原理是（ ）。",[566,568,570,572],{"key":20,"text":567,"correct":26},"降温，进而抑制电弧",{"key":24,"text":569,"correct":26},"增强介质去游离能力",{"key":28,"text":571,"correct":22},"抑制游离作用",{"key":72,"text":573,"correct":26},"加快离子扩散和复合",{"id":575,"libraryId":5,"type":15,"typeLabel":16,"stem":576,"options":577,"answer":28,"analysis":30},421094,"（ ）的用途是保护电气设备免受过载和短路电流的损害。",[578,580,582,583],{"key":20,"text":579,"correct":26},"绝缘子",{"key":24,"text":581,"correct":26},"电流互感器",{"key":28,"text":274,"correct":22},{"key":72,"text":270,"correct":26},[585,589,593,596,599,603],{"id":586,"name":587,"category":7,"favorite":588},256,"综合应用能力",6,{"id":590,"name":591,"category":7,"favorite":592},194,"《公安》基础知识+专业",5,{"id":594,"name":595,"category":7,"favorite":592},195,"政法干警",{"id":597,"name":598,"category":7,"favorite":592},255,"职业能力倾向测验",{"id":600,"name":601,"category":7,"favorite":602},212,"国家公务员-行政能力测试",4,{"id":604,"name":605,"category":7,"favorite":602},254,"公共基础知识"]