[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-197-14":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":544},{"id":5,"name":6,"category":7,"favorite":8},197,"电工类 (电网)","公务员",0,14,50,2675,[13,34,46,58,70,82,94,106,118,130,142,154,164,176,188,198,208,218,228,238,246,253,261,269,280,288,296,307,319,331,343,354,366,374,381,396,406,416,424,432,439,451,463,473,482,492,502,512,522,532],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},420696,1,"单选题","关于电力系统的电压调整，下述说法中正确的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","只要保证电力系统在所要求的电压水平下的无功功率平衡，就可以将电力系统中所有用电设备的电压限制在允许的范围",false,{"key":24,"text":25,"correct":26},"B","要维持电力系统用电设备的电压在允许的范围，首要的条件是要满足在所要求的电压水平下的电力系统的无功率平衡",true,{"key":28,"text":29,"correct":22},"C","在任何情况下都可以通过改变变压器变比，将电力系统中所有用电设备的电压限制在允许范围",{"key":31,"text":32,"correct":22},"D","当无功负荷变化时，不必改变系统无功电源的总出力，只要调整电力系统的无功潮流分布总可以将电力系统用电设备的电压控制在允许范围","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},420697,"无功备用容量一般取最大无功功率负荷的（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"20%",{"key":24,"text":41,"correct":22},"15%",{"key":28,"text":43,"correct":22},"10%",{"key":31,"text":45,"correct":26},"7%～8%",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},420698,"一回1000kV特高压输电线路的输电能力可达到500kV常规输电线路输电能力的（ ）倍以上。在输送相同功率情况下，1000kV线路功率损耗约为500kV线路的（ ）左右。",[50,52,54,56],{"key":20,"text":51,"correct":22},"2倍、1\u002F4",{"key":24,"text":53,"correct":26},"4倍、1\u002F16",{"key":28,"text":55,"correct":22},"2倍、1\u002F16",{"key":31,"text":57,"correct":22},"4倍、1\u002F4",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},420699,"电流互感器二次绕组额定电流为（ ）正常运行时严禁开路。",[62,64,66,68],{"key":20,"text":63,"correct":26},"5",{"key":24,"text":65,"correct":22},"10",{"key":28,"text":67,"correct":22},"15",{"key":31,"text":69,"correct":22},"20",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},420700,"电力系统等值电路中，所有参数应为归算到同一电压等级（基本级）的参数，关于基本级的选择，下述说法中正确的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"必须选择最高电压等级作为基本级",{"key":24,"text":77,"correct":26},"在没有明确要求的情况下，选择最高电压等级作为基本级",{"key":28,"text":79,"correct":22},"在没有明确要求的情况下选择最低电压等级作为基本级",{"key":31,"text":81,"correct":22},"选择发电机电压等级作为基本级",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},420701,"在Y\u002F△-11接线变压器星形侧两相短路时，关于变压器三角形侧三相线路中的电流，下述说法中正确的是（ ）",[86,88,90,92],{"key":20,"text":87,"correct":26},"变压器三角形侧三相线路中都有电流流过，其中故障相中的滞后相电流为其它两相的两倍",{"key":24,"text":89,"correct":22},"变压器三角形侧三相线路中都有电流流过，其中故障相中的超前相电流为其它两相的两倍",{"key":28,"text":91,"correct":22},"变压器三角形侧仅故障相线路中有电流流过",{"key":31,"text":93,"correct":22},"变压器三角形侧三相线路中都有电流流过，其中非故障相线电流为其它两相线电流的两倍",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},420702,"若待计算处与短路点间有星形\u002F三角形连接的变压器，则正序电流三角形侧的较星形侧相位的（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":26},"超前30°",{"key":24,"text":101,"correct":22},"相位相同",{"key":28,"text":103,"correct":22},"滞后30°",{"key":31,"text":105,"correct":22},"不存在相位关系",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},420703,"利用特高压输电技术，实现远距离、大规模的电力输送，有利于减少电力损耗、节约土地资源、保护环境、节约投资，促进我国（ ）基地的集约化开发。",[110,112,114,116],{"key":20,"text":111,"correct":22},"大电网、大机组、大用户",{"key":24,"text":113,"correct":26},"大煤电、大水电、大核电",{"key":28,"text":115,"correct":22},"大电网、大火电、大水电",{"key":31,"text":117,"correct":22},"大能源、大容量、大用户",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":31,"analysis":33},420704,"电力系统中出现概率最小的故障类型是（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"单相接地",{"key":24,"text":125,"correct":22},"两相接地",{"key":28,"text":127,"correct":22},"两相相间",{"key":31,"text":129,"correct":26},"三相接地",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":28,"analysis":33},420705,"下列故障形式中对称的短路故障为（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":22},"单相接地短路",{"key":24,"text":137,"correct":22},"两相短路",{"key":28,"text":139,"correct":26},"三相短路",{"key":31,"text":141,"correct":22},"两相接地短路",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":28,"analysis":33},420707,"关于同步发电机机端发生三相短路时短路电流中各分量的变化，下述说法中错误的是（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":22},"定子短路电流中的非周期分量和倍频分量以同一时间常数逐渐衰减到零",{"key":24,"text":149,"correct":22},"定子绕组中的基频周期分量有效值从短路瞬间的数值逐渐衰减到稳态值",{"key":28,"text":151,"correct":26},"定子绕组的基频周期分量保持不变，其他分量逐渐衰减到零",{"key":31,"text":153,"correct":22},"定子绕组中的基频周期电流分量在短路发生后开始阶段衰减速度快，后阶段衰减速度慢",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":20,"analysis":33},420709,"并联电容器能向系统提供（ ）无功功率。",[158,160,162],{"key":20,"text":159,"correct":26},"感性",{"key":24,"text":161,"correct":22},"容性",{"key":28,"text":163,"correct":22},"不确定",{"id":165,"libraryId":5,"type":15,"typeLabel":16,"stem":166,"options":167,"answer":20,"analysis":33},420710,"110kV及以上电力系统中，架空输电线路全线假设避雷线的目的是（ ）。",[168,170,172,174],{"key":20,"text":169,"correct":26},"减少线路雷击事故，提高供电质量",{"key":24,"text":171,"correct":22},"减少雷击事故，提高电能质量",{"key":28,"text":173,"correct":22},"减少雷击事故，降低输电线路对地电压",{"key":31,"text":175,"correct":22},"减少雷击事故，提高输电线路的耐压水平",{"id":177,"libraryId":5,"type":15,"typeLabel":16,"stem":178,"options":179,"answer":31,"analysis":33},420711,"运行中的电流互感器运行在（ ）。",[180,182,184,186],{"key":20,"text":181,"correct":22},"空载状态",{"key":24,"text":183,"correct":22},"近似空载状态",{"key":28,"text":185,"correct":22},"短路状态",{"key":31,"text":187,"correct":26},"近似短路状态",{"id":189,"libraryId":5,"type":15,"typeLabel":16,"stem":190,"options":191,"answer":24,"analysis":33},420712,"电流互感器二次侧开路所引起的后果，一是电流互感器铁芯烧坏，二是电流互感器产生高电压严重危及（ ）安全。",[192,194,196],{"key":20,"text":193,"correct":22},"设备",{"key":24,"text":195,"correct":26},"工作人员人身",{"key":28,"text":197,"correct":22},"电网",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":24,"analysis":33},420713,"变压器油质变坏，对油质的简易鉴别可从油的（ ）加以判断。",[202,204,206],{"key":20,"text":203,"correct":22},"使用日期、颜色、油量",{"key":24,"text":205,"correct":26},"颜色、透明度、气味",{"key":28,"text":207,"correct":22},"气味、透明度、使用日期",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":28,"analysis":33},420714,"集成电路型、微机型保护装置的电流、电压引入线应采用屏蔽电缆，同时（ ）。",[212,214,216],{"key":20,"text":213,"correct":22},"电缆的屏蔽层应在开关场可靠接地",{"key":24,"text":215,"correct":22},"电缆的屏蔽层应在控制室可靠接地",{"key":28,"text":217,"correct":26},"电缆的屏蔽层应在开关场和控制室两端可靠接地",{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":20,"analysis":33},420715,"短路电流运算曲线编制时，计算电抗仅编制到3.5，其原因是（ ）。",[222,224,226],{"key":20,"text":223,"correct":26},"对于计算电抗大于3.5的电源可以视为无限大功率电源，其任意时刻的短路电流周期分量有效值，就是短路瞬间短路电流周期分量的起始有效值",{"key":24,"text":225,"correct":22},"实际工程上不存在计算电抗大于3.5的情况",{"key":28,"text":227,"correct":22},"由于计算电抗大于3.5的电源，其向短路点提供的短路电流很小，实际计算时可以忽略",{"id":229,"libraryId":5,"type":15,"typeLabel":16,"stem":230,"options":231,"answer":28,"analysis":33},420716,"电网装机容量在300万千瓦及以上的，电力系统正常频率偏差允许值为（ ）。",[232,234,236],{"key":20,"text":233,"correct":22},"±0.5HZ",{"key":24,"text":235,"correct":22},"±0.3HZ",{"key":28,"text":237,"correct":26},"±0.2HZ",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":24,"analysis":33},420717,"在进行短路电流计算时采用标幺值计算电抗器的计算公式为（ ）。",[242,243,244,245],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":248,"answer":31,"analysis":33},420718,[249,250,251,252],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":20,"analysis":33},420719,"判断同步发电机并列运行静态稳定性的实用判据是（ ）。",[257,258,259,260],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":20,"analysis":33},420720,"对同步发电机并列运行静态稳定储备系数的要求是（ ）。",[265,266,267,268],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":271,"answer":20,"analysis":33},420721,[272,274,276,278],{"key":20,"text":273,"correct":26},"2.69",{"key":24,"text":275,"correct":22},"3.52",{"key":28,"text":277,"correct":22},"1.55",{"key":31,"text":279,"correct":22},"3.46",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":31,"analysis":33},420722,"对于两相短路接地短路附加阻抗M为（ ）。",[284,285,286,287],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":289,"libraryId":5,"type":15,"typeLabel":16,"stem":290,"options":291,"answer":28,"analysis":33},420723,"关于各种金属性短路情况下的边界条件方程，错误的是（ ）。",[292,293,294,295],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":297,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":298,"answer":31,"analysis":33},420724,[299,301,303,305],{"key":20,"text":300,"correct":22},"1号机组",{"key":24,"text":302,"correct":22},"2号机组",{"key":28,"text":304,"correct":22},"3号机组",{"key":31,"text":306,"correct":26},"4号机组",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":20,"analysis":33},420725,"电力系统稳定分析的最终目的是（ ）。",[311,313,315,317],{"key":20,"text":312,"correct":26},"求发电机转子摇摆曲线，并根据摇摆曲线判断系统运行的稳定性",{"key":24,"text":314,"correct":22},"求发电机的功角特性曲线，并根据发电机的功角特性曲线判断系统运行的稳定性",{"key":28,"text":316,"correct":22},"求发电机定子电流的变化曲线，并根据电流变化曲线判断系统运行的稳定性",{"key":31,"text":318,"correct":22},"求发电机端电压变化曲线，并根据电压变化曲线判断系统运行的稳定性",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":24,"analysis":33},420728,"真空断路器大修周期是（ ）。",[323,325,327,329],{"key":20,"text":324,"correct":22},"一年",{"key":24,"text":326,"correct":26},"两年",{"key":28,"text":328,"correct":22},"200次操作",{"key":31,"text":330,"correct":22},"100次操作",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":31,"analysis":33},420729,"在电力系统分析和计算中，功率和阻抗一般分别是指（ ）。",[335,337,339,341],{"key":20,"text":336,"correct":22},"一相功率，一相阻抗",{"key":24,"text":338,"correct":22},"三相功率，一相阻抗",{"key":28,"text":340,"correct":22},"三相功率，三相阻抗",{"key":31,"text":342,"correct":26},"三相功率，一相等值阻抗",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":20,"analysis":33},420731,"电力系统受扰动后处于（ ）。",[347,349,351,353],{"key":20,"text":348,"correct":26},"暂态过程",{"key":24,"text":350,"correct":22},"稳态过程",{"key":28,"text":352,"correct":22},"故障状态",{"key":31,"text":163,"correct":22},{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":28,"analysis":33},420732,"当采用制动电阻提高电力系统中同步发电机并列运行的暂态稳定性时，下述说法中错误的是（ ）。",[358,360,362,364],{"key":20,"text":359,"correct":22},"制动电阻提高电力系统并列运行暂态稳定性的原理是增大了故障情况下发电机输出的电磁功率，减小了发电机的过剩功率",{"key":24,"text":361,"correct":22},"采用串联制动时制动电阻越大，制动作用越大",{"key":28,"text":363,"correct":26},"采用串联制动时制动电阻越大，制动作用越小",{"key":31,"text":365,"correct":22},"为提高串联制动效果，应采用过制动方式",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":368,"answer":24,"analysis":33},420734,[369,370,371,373],{"key":20,"text":139,"correct":22},{"key":24,"text":137,"correct":26},{"key":28,"text":372,"correct":22},"两相短路接地",{"key":31,"text":135,"correct":22},{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":376,"answer":20,"analysis":33},420735,[377,378,379,380],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":394,"analysis":33},420736,"高压导线断落地面，救护人员要进入距落地点8-10米范围内抢救触电者救护人员必须（ ）。",[385,387,389,391,393],{"key":20,"text":386,"correct":22},"快步进入",{"key":24,"text":388,"correct":22},"戴绝缘手套",{"key":28,"text":390,"correct":22},"小步迈进",{"key":31,"text":392,"correct":22},"戴安全帽",{"key":394,"text":395,"correct":26},"E","穿绝缘靴、双脚并拢、稳步跃进",{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":28,"analysis":33},420737,"电价构成应包括价格执行期内电力成本、（ ）和合理收益。",[400,402,404],{"key":20,"text":401,"correct":22},"维修费",{"key":24,"text":403,"correct":22},"折旧费",{"key":28,"text":405,"correct":26},"税金",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":28,"analysis":33},420738,"发、供电设备容量是按系统最大负荷需求量安排的，它对应电力成本中的容量成本，是以（ ）计算基本电费。",[410,412,414],{"key":20,"text":411,"correct":22},"用户实际用电量",{"key":24,"text":413,"correct":22},"用户实际用电量\u002F功率因数",{"key":28,"text":415,"correct":26},"用户用电的最高需求量或变压器容量",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":28,"analysis":33},420739,"对于三相短路附加阻抗M为（ ）。",[420,421,422,423],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":28,"analysis":33},420740,"要增加并联在电网上运行的发电机的有功输出，可以（ ）。",[428,429,430,431],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":434,"answer":24,"analysis":33},420741,[435,436,437,438],{"key":20,"text":139,"correct":22},{"key":24,"text":137,"correct":26},{"key":28,"text":372,"correct":22},{"key":31,"text":135,"correct":22},{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":20,"analysis":33},420742,"电力系统静态稳定性是指（ ）。",[443,445,447,449],{"key":20,"text":444,"correct":26},"正常运行的电力系统受到小干扰作用后，不发生自发振荡或失步，自动恢复到初始运行状态的能力",{"key":24,"text":446,"correct":22},"正常运行的电力系统受到小于扰作用后，保持同步运行的能力",{"key":28,"text":448,"correct":22},"正常运行的电力系统受到大于扰作用后，保持同步运行的能力",{"key":31,"text":450,"correct":22},"正常运行的电力系统受到大于扰作用后，不发生自发振荡或失步，自动恢复到初始运行状态的能力",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":20,"analysis":33},420743,"对于两相短路其序网络的连接是（ ）。",[455,457,459,461],{"key":20,"text":456,"correct":26},"正序和负序并联",{"key":24,"text":458,"correct":22},"正序负序零序串联",{"key":28,"text":460,"correct":22},"正序负序零序并联",{"key":31,"text":462,"correct":22},"负序正序并联再和零序串联",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":28,"analysis":33},420744,"在公共场所施工，应有安全措施，悬挂施工单位标志，（ ），并配有礼貌用语。",[467,469,471],{"key":20,"text":468,"correct":22},"安全警示",{"key":24,"text":470,"correct":22},"安全标示",{"key":28,"text":472,"correct":26},"安全标志",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":24,"analysis":33},420745,"变压器小修周期（ ）。",[477,479,480],{"key":20,"text":478,"correct":22},"半年",{"key":24,"text":324,"correct":26},{"key":28,"text":481,"correct":22},"五年",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":20,"analysis":33},420746,"用户在供电企业规定的期限内未交清电费时，应承担电费滞纳的违约责任。电费违约金从逾期之日计算至交纳日止，居民用户每日按欠费总额的（ ）计算",[486,488,490],{"key":20,"text":487,"correct":26},"1‰",{"key":24,"text":489,"correct":22},"2‰",{"key":28,"text":491,"correct":22},"3‰",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":24,"analysis":33},420747,"防止系统谐波的影响当电网背景谐波为5次及以上时，可配电抗率为（ ）的串联电抗器。",[496,498,500],{"key":20,"text":497,"correct":22},"4～6%",{"key":24,"text":499,"correct":26},"4.5～6%",{"key":28,"text":501,"correct":22},"5～6%",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":20,"analysis":33},420748,"处理事故时，为了迅速切出故障，限制事故发展，迅速恢复供电，并使系统频率、电压恢复正常，可以不用（ ）操作。",[506,508,510],{"key":20,"text":507,"correct":26},"操作票进行",{"key":24,"text":509,"correct":22},"两人进行",{"key":28,"text":511,"correct":22},"填写操作记录薄中",{"id":513,"libraryId":5,"type":15,"typeLabel":16,"stem":514,"options":515,"answer":28,"analysis":33},420749,"以实现全社会电力资源优化配置为目标，开展（ ）和服务活动，减少客户用电成本，提高电网用电负荷率。",[516,518,520],{"key":20,"text":517,"correct":22},"节约用电",{"key":24,"text":519,"correct":22},"用电管理",{"key":28,"text":521,"correct":26},"电力需求侧管理",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":24,"analysis":33},420750,"双母线接线形式的变电站，当某一联接元件发生故障且断路器拒动时，失灵保护动作应首先跳开（ ）。",[526,528,530],{"key":20,"text":527,"correct":22},"拒动断路器所在母线上的所有开关",{"key":24,"text":529,"correct":26},"母联断路器",{"key":28,"text":531,"correct":22},"故障元件的其它断路器",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":20,"analysis":33},420751,"大扰动后，减少原动机出力的主要目的是为了提高系统的（ ）。",[536,538,540,542],{"key":20,"text":537,"correct":26},"暂态稳定",{"key":24,"text":539,"correct":22},"静态稳定",{"key":28,"text":541,"correct":22},"电压稳定",{"key":31,"text":543,"correct":22},"经济性",[545,549,553,556,559,563],{"id":546,"name":547,"category":7,"favorite":548},256,"综合应用能力",6,{"id":550,"name":551,"category":7,"favorite":552},194,"《公安》基础知识+专业",5,{"id":554,"name":555,"category":7,"favorite":552},195,"政法干警",{"id":557,"name":558,"category":7,"favorite":552},255,"职业能力倾向测验",{"id":560,"name":561,"category":7,"favorite":562},212,"国家公务员-行政能力测试",4,{"id":564,"name":565,"category":7,"favorite":562},254,"公共基础知识"]