[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-197-13":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":599},{"id":5,"name":6,"category":7,"favorite":8},197,"电工类 (电网)","公务员",0,13,50,2675,[13,34,46,58,70,82,94,106,118,130,142,152,164,176,188,200,212,224,236,246,256,266,276,285,295,310,320,334,344,356,368,380,392,403,415,427,439,451,463,471,481,493,505,517,529,541,553,563,575,587],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},420636,1,"单选题","关于有功备用容量，下列说法错误的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","检修备用应该是冷备用",false,{"key":24,"text":25,"correct":26},"B","事故备用必须全部是热备用",true,{"key":28,"text":29,"correct":22},"C","负荷备用应为热备用",{"key":31,"text":32,"correct":22},"D","国民经济备用应为冷备用","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},420638,"电力线路中，电阻R主要反映线路带压运行后产生的（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":26},"热效应",{"key":24,"text":41,"correct":22},"电场效应",{"key":28,"text":43,"correct":22},"磁场效应",{"key":31,"text":45,"correct":22},"电晕效应",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},420640,"变压器等值电路中，电纳的物理意义表征的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"铁损",{"key":24,"text":53,"correct":22},"漏磁通",{"key":28,"text":55,"correct":22},"铜损",{"key":31,"text":57,"correct":26},"激磁阻抗",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},420641,"为了能及时向增加的负荷供电而设置的备用容量应是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"事故备用",{"key":24,"text":65,"correct":22},"检修备用",{"key":28,"text":67,"correct":22},"冷备用",{"key":31,"text":69,"correct":26},"热备用",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},420642,"电力系统并列运行暂态稳定性的分析计算过程，求解发电机转子摇摆曲线的计算方法是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"小干扰法",{"key":24,"text":77,"correct":22},"对称分量法",{"key":28,"text":79,"correct":26},"数值解法",{"key":31,"text":81,"correct":22},"牛顿-拉夫逊法",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},420644,"在多电压等级电磁环网中，改变变压器的变比（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":26},"主要是改变无功功率分布",{"key":24,"text":89,"correct":22},"主要是改变有功功率分布",{"key":28,"text":91,"correct":22},"功率分布不变",{"key":31,"text":93,"correct":22},"变比和功率分布无关",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},420645,"电力生产与电网运行应当遵循（ ）的原则。",[98,100,102,104],{"key":20,"text":99,"correct":22},"自主经营、自负盈亏",{"key":24,"text":101,"correct":26},"安全、优质、经济",{"key":28,"text":103,"correct":22},"服务市场经济规律",{"key":31,"text":105,"correct":22},"诚实守信、秉公办事",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},420647,"-台并联在电网上运行的三相同步发电机，输出一0.5（滞后）的额定电流，现在要让它输出-0.8（滞后）的额定电流，则可以（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"输入功率不变，增加励磁电流",{"key":24,"text":113,"correct":26},"增加输入功率，励磁电流不变",{"key":28,"text":115,"correct":22},"减少输入功率，增加励磁电流",{"key":31,"text":117,"correct":22},"增加输入功率，减少励磁电流",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":20,"analysis":33},420648,"节点导纳矩阵为方阵，其阶数等于（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":26},"网络中除参考节点以外的节点数",{"key":24,"text":125,"correct":22},"网络中所有节点数",{"key":28,"text":127,"correct":22},"网络中所有节点数+1",{"key":31,"text":129,"correct":22},"网络中所有节点数+2",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":20,"analysis":33},420650,"发电机在某一运行点运行时，受到小于扰后，发电机输出电磁功率随功角增大而增大，则该运行点是否稳定（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":26},"稳定",{"key":24,"text":137,"correct":22},"不稳定",{"key":28,"text":139,"correct":22},"处于稳定边界",{"key":31,"text":141,"correct":22},"以上都不是",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":24,"analysis":33},420652,"“无损耗线路”，且负荷功率因数为1，当输送的有功功率小于自然功率时，线路消耗的（ ）无功功率。",[146,148,150],{"key":20,"text":147,"correct":22},"感性",{"key":24,"text":149,"correct":26},"容性",{"key":28,"text":151,"correct":22},"不确定",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":20,"analysis":33},420653,"同步发电机三相短路实用计算中在发电机方面所采取的假设条件是（ ）。",[156,158,160,162],{"key":20,"text":157,"correct":26},"发电机用次暂态电动势和直轴次暂态电抗表示，系统中所有发电机电动势相位相同",{"key":24,"text":159,"correct":22},"发电机用空载电动势和直轴同步电抗表示，系统中所有发电机的电动势相位相同",{"key":28,"text":161,"correct":22},"发电机用次暂态电动势和直轴同步电抗表示，系统中所有发电机的电动势相位相同",{"key":31,"text":163,"correct":22},"发电机用次暂态电动势和交轴次暂态电抗表示，系统中所有发电机的电动势相位相同",{"id":165,"libraryId":5,"type":15,"typeLabel":16,"stem":166,"options":167,"answer":20,"analysis":33},420654,"频率的一次调整是由（ ）。",[168,170,172,174],{"key":20,"text":169,"correct":26},"发电机组的调速系统完成的",{"key":24,"text":171,"correct":22},"负荷的频率特性来完成的",{"key":28,"text":173,"correct":22},"发电机组的调频系统完成的",{"key":31,"text":175,"correct":22},"有功功率的经济分配完成的",{"id":177,"libraryId":5,"type":15,"typeLabel":16,"stem":178,"options":179,"answer":20,"analysis":33},420655,"单机无穷大系统中，假设自动调节励磁装置使E′q恒定，则隐极发电机的功率极限出现的功角在（ ）90°处。",[180,182,184,186],{"key":20,"text":181,"correct":26},"大于",{"key":24,"text":183,"correct":22},"小于",{"key":28,"text":185,"correct":22},"等于",{"key":31,"text":187,"correct":22},"不一定",{"id":189,"libraryId":5,"type":15,"typeLabel":16,"stem":190,"options":191,"answer":24,"analysis":33},420656,"当额定电压为220\u002F230kV时，自然功率标准值为（ ）。",[192,194,196,198],{"key":20,"text":193,"correct":22},"100MW",{"key":24,"text":195,"correct":26},"175MW",{"key":28,"text":197,"correct":22},"300MW",{"key":31,"text":199,"correct":22},"80MW",{"id":201,"libraryId":5,"type":15,"typeLabel":16,"stem":202,"options":203,"answer":24,"analysis":33},420657,"定子各绕组间的互感系数是每过（ ）循环一次。",[204,206,208,210],{"key":20,"text":205,"correct":22},"90°",{"key":24,"text":207,"correct":26},"180°",{"key":28,"text":209,"correct":22},"270°",{"key":31,"text":211,"correct":22},"360°",{"id":213,"libraryId":5,"type":15,"typeLabel":16,"stem":214,"options":215,"answer":20,"analysis":33},420658,"原点和耗量特性曲线上某一点连线的斜率（ ）。",[216,218,220,222],{"key":20,"text":217,"correct":26},"比耗量",{"key":24,"text":219,"correct":22},"单位调节功率",{"key":28,"text":221,"correct":22},"耗量特性",{"key":31,"text":223,"correct":22},"耗量微增率",{"id":225,"libraryId":5,"type":15,"typeLabel":16,"stem":226,"options":227,"answer":20,"analysis":33},420660,"关于电力系统发生短路故障时的零序电流，下述说法中错误的是（ ）。",[228,230,232,234],{"key":20,"text":229,"correct":26},"不对称短路时，故障处三相电压不对称所分解出的零序电压是电力系统出现零序电流的充分必要条件",{"key":24,"text":231,"correct":22},"只有中性点直接接地系统中发生接地短路时才会产生零序电流",{"key":28,"text":233,"correct":22},"零序电流从短路点流向中性点接地变压器或中性点接地发电机的中性点",{"key":31,"text":235,"correct":22},"不对称短路时，故障处三相电压不对称所分解出的零序电压是电力系统出现零序电流的必要条件，但不是充分条件",{"id":237,"libraryId":5,"type":15,"typeLabel":16,"stem":238,"options":239,"answer":20,"analysis":33},420661,"减少用电容量的期限，应根据所提出的申请确定，但最短期限不得少于六个月，最长期限不得超过（ ）。",[240,242,244],{"key":20,"text":241,"correct":26},"二年",{"key":24,"text":243,"correct":22},"一年",{"key":28,"text":245,"correct":22},"六个月",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":20,"analysis":33},420662,"违约使用电费是指因违约用电或窃电行为承担相应违约的责任，向供电企业补交（ ）。",[250,252,254],{"key":20,"text":251,"correct":26},"违约费用",{"key":24,"text":253,"correct":22},"经济补偿",{"key":28,"text":255,"correct":22},"电费滞纳金",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":24,"analysis":33},420663,"对于160KVA及以上高压供电的电力用户，高功率负荷时变压器一次侧功率因数宜达到（ ）以上。",[260,262,264],{"key":20,"text":261,"correct":22},"0.85",{"key":24,"text":263,"correct":26},"0.90",{"key":28,"text":265,"correct":22},"0.95",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":28,"analysis":33},420664,"人与带电设备的安全距离60～110KV为（ ）米。",[270,272,274],{"key":20,"text":271,"correct":22},"1",{"key":24,"text":273,"correct":22},"1.2",{"key":28,"text":275,"correct":26},"1.5",{"id":277,"libraryId":5,"type":15,"typeLabel":16,"stem":278,"options":279,"answer":20,"analysis":33},420665,"当SF6气体钢瓶内压力降至（ ）个大气压时，应停止引出气体",[280,281,283],{"key":20,"text":271,"correct":26},{"key":24,"text":282,"correct":22},"2",{"key":28,"text":284,"correct":22},"3",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":28,"analysis":33},420666,"电容型验电器起动电压试验的试验周期为（ ）",[289,291,293],{"key":20,"text":290,"correct":22},"1月",{"key":24,"text":292,"correct":22},"1季度",{"key":28,"text":294,"correct":26},"1年",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":308,"analysis":33},420667,"触电急救的第一步是（ ）。",[299,301,303,305,307],{"key":20,"text":300,"correct":22},"迅速联系医疗部门救治",{"key":24,"text":302,"correct":22},"人工呼吸",{"key":28,"text":304,"correct":22},"胸外压",{"key":31,"text":306,"correct":22},"心肺复苏法",{"key":308,"text":309,"correct":26},"E","迅速脱离电源",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":28,"analysis":33},420668,"紧急事故抢修工作可不用工作票，但应履行（ ），并记录操作记录薄中。",[314,316,318],{"key":20,"text":315,"correct":22},"停电程序",{"key":24,"text":317,"correct":22},"操作顺序",{"key":28,"text":319,"correct":26},"工作许可手续",{"id":321,"libraryId":5,"type":15,"typeLabel":16,"stem":322,"options":323,"answer":308,"analysis":33},420669,"变压器在正常运行时，发出的声音是（ ）。",[324,326,328,330,332],{"key":20,"text":325,"correct":22},"“轰轰”声",{"key":24,"text":327,"correct":22},"“嘶嘶”声",{"key":28,"text":329,"correct":22},"“吱吱”声",{"key":31,"text":331,"correct":22},"大而沉闷的“嗡嗡”声",{"key":308,"text":333,"correct":26},"轻微、清晰而有规律的“嗡嗡”声",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":24,"analysis":33},420670,"负荷开关分闸后活门关闭，开关室设备与（ ）安全隔离，更换熔断器或维修非常安全。",[338,340,342],{"key":20,"text":339,"correct":22},"线路",{"key":24,"text":341,"correct":26},"母线",{"key":28,"text":343,"correct":22},"变压器",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":28,"analysis":33},420671,"在电力系统中，平衡节点的数目是（ ）。",[348,350,352,354],{"key":20,"text":349,"correct":22},"大量的",{"key":24,"text":351,"correct":22},"数量最多",{"key":28,"text":353,"correct":26},"只有一个",{"key":31,"text":355,"correct":22},"少量或没有",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":20,"analysis":33},420672,"无功功率流过线路电阻时（ ）。",[360,362,364,366],{"key":20,"text":361,"correct":26},"产生有功功率损耗",{"key":24,"text":363,"correct":22},"产生无功功率损耗",{"key":28,"text":365,"correct":22},"既产生有功功率损耗，又产生无功损耗",{"key":31,"text":367,"correct":22},"既不产生有功功率损耗，又不产生无功损耗",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":20,"analysis":33},420673,"有功功率最优分配的准则是（ ）。",[372,374,376,378],{"key":20,"text":373,"correct":26},"按等耗量微增率",{"key":24,"text":375,"correct":22},"按等比耗量",{"key":28,"text":377,"correct":22},"按效率相同",{"key":31,"text":379,"correct":22},"按消耗量",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":20,"analysis":33},420675,"在用户受电端，35kV及以上系统允许的电压偏移为（ ）。",[384,386,388,390],{"key":20,"text":385,"correct":26},"-5%～+5%",{"key":24,"text":387,"correct":22},"-7%～+7%",{"key":28,"text":389,"correct":22},"-10%～+5%",{"key":31,"text":391,"correct":22},"-10%～+7.5%",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":28,"analysis":33},420676,"在电力系统其他地点短路时冲击系数为（ ）。",[396,398,400,402],{"key":20,"text":397,"correct":22},"1.9",{"key":24,"text":399,"correct":22},"1.85",{"key":28,"text":401,"correct":26},"1.8",{"key":31,"text":282,"correct":22},{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":405,"options":406,"answer":24,"analysis":33},420677,"工作人员工作中正常活动范围与220KV带电设备的最小安全距离为（ ）",[407,409,411,413],{"key":20,"text":408,"correct":22},"1米",{"key":24,"text":410,"correct":26},"1.5米",{"key":28,"text":412,"correct":22},"2米",{"key":31,"text":414,"correct":22},"3米",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":31,"analysis":33},420678,"事故备用一般为最大负荷的（ ），但不得小于系统中最大机组容量。",[419,421,423,425],{"key":20,"text":420,"correct":22},"2%～5%",{"key":24,"text":422,"correct":22},"4%～5%",{"key":28,"text":424,"correct":22},"5%～7%",{"key":31,"text":426,"correct":26},"5%～10%",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":28,"analysis":33},420679,"引起停电或限电的原因消除后，供电企业应在（ ）内恢复供电。",[431,433,435,437],{"key":20,"text":432,"correct":22},"30分钟",{"key":24,"text":434,"correct":22},"24小时",{"key":28,"text":436,"correct":26},"3天",{"key":31,"text":438,"correct":22},"7天",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":28,"analysis":33},420680,"既能充当有功功率电源，又是最基本的无功功率电源的是（ ）。",[443,445,447,449],{"key":20,"text":444,"correct":22},"调相机",{"key":24,"text":446,"correct":22},"电容器",{"key":28,"text":448,"correct":26},"同步发电机",{"key":31,"text":450,"correct":22},"电抗器",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":28,"analysis":33},420681,"在下面所列出的各组无功电源中，完全具有正的电压调节效应的一组是（ ）。",[455,457,459,461],{"key":20,"text":456,"correct":22},"调相机、TCR型静止无功补偿器、并联电容器",{"key":24,"text":458,"correct":22},"TCR型静止无功补偿器、SR型静止无功补偿器、并联电容器",{"key":28,"text":460,"correct":26},"调相机、SR型静止无功补偿器、TSC型静止无功补偿器",{"key":31,"text":462,"correct":22},"调相机、SR型静止无功补偿器、TCR型静止无功补偿器",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":28,"analysis":33},420682,"频率的二次调整是由（ ）。",[467,468,469,470],{"key":20,"text":169,"correct":22},{"key":24,"text":171,"correct":22},{"key":28,"text":173,"correct":26},{"key":31,"text":175,"correct":22},{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":20,"analysis":33},420683,"调整计划外负荷增加而设置的备用是（ ）。",[475,477,478,479],{"key":20,"text":476,"correct":26},"负荷备用",{"key":24,"text":63,"correct":22},{"key":28,"text":65,"correct":22},{"key":31,"text":480,"correct":22},"国民经济备用",{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":28,"analysis":33},420685,"枯水季节承担调频任务的是（ ）。",[485,487,489,491],{"key":20,"text":486,"correct":22},"高温高压火电厂",{"key":24,"text":488,"correct":22},"中温中压火电厂",{"key":28,"text":490,"correct":26},"大水电厂",{"key":31,"text":492,"correct":22},"核电厂",{"id":494,"libraryId":5,"type":15,"typeLabel":16,"stem":495,"options":496,"answer":20,"analysis":33},420686,"短路电流中一定存在零序分量的短路类型是（ ）。",[497,499,501,503],{"key":20,"text":498,"correct":26},"接地短路",{"key":24,"text":500,"correct":22},"相间短路",{"key":28,"text":502,"correct":22},"不对称接地短路",{"key":31,"text":504,"correct":22},"三相短路",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":24,"analysis":33},420687,"分析电力系统短路电流的工程计算，在多数情况下只需要计算短路电流（ ）。",[509,511,513,515],{"key":20,"text":510,"correct":22},"稳态值",{"key":24,"text":512,"correct":26},"基频交流分量初始值",{"key":28,"text":514,"correct":22},"0.2s",{"key":31,"text":516,"correct":22},"冲击电流",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":24,"analysis":33},420688,"电网运行的客观规律包括（ ）。",[521,523,525,527],{"key":20,"text":522,"correct":22},"瞬时性、快速性、电网事故发生突然性。",{"key":24,"text":524,"correct":26},"同时性、平衡性、电网事故发生突然性。",{"key":28,"text":526,"correct":22},"变化性、快速性、电网事故发生突然性。",{"key":31,"text":528,"correct":22},"异步性、变化性、电网事故发生突然性。",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":20,"analysis":33},420689,"调节同步发电机励磁电流就能改变发电机输出的（ ）。",[533,535,537,539],{"key":20,"text":534,"correct":26},"无功功率",{"key":24,"text":536,"correct":22},"有功功率",{"key":28,"text":538,"correct":22},"频率",{"key":31,"text":540,"correct":22},"励磁阻抗",{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":24,"analysis":33},420690,"水、火电厂进行有功功率经济分配时，在丰水期水煤转换系数取值（ ）。",[545,547,549,551],{"key":20,"text":546,"correct":22},"上升",{"key":24,"text":548,"correct":26},"下降",{"key":28,"text":550,"correct":22},"不变",{"key":31,"text":552,"correct":22},"以上情况都有可能",{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":20,"analysis":33},420691,"系统发生短路故障后，越靠近短路点，电压（ ）。",[557,559,561,562],{"key":20,"text":558,"correct":26},"越低",{"key":24,"text":560,"correct":22},"越高",{"key":28,"text":550,"correct":22},{"key":31,"text":151,"correct":22},{"id":564,"libraryId":5,"type":15,"typeLabel":16,"stem":565,"options":566,"answer":20,"analysis":33},420693,"三相短路的短路电流只包含（ ）。",[567,569,571,573],{"key":20,"text":568,"correct":26},"正序分量",{"key":24,"text":570,"correct":22},"负序分量",{"key":28,"text":572,"correct":22},"零序分量",{"key":31,"text":574,"correct":22},"反分量",{"id":576,"libraryId":5,"type":15,"typeLabel":16,"stem":577,"options":578,"answer":28,"analysis":33},420694,"对于两相短路接地其序网络的连接是（ ）。",[579,581,583,585],{"key":20,"text":580,"correct":22},"正序和负序并联",{"key":24,"text":582,"correct":22},"正序负序零序串联",{"key":28,"text":584,"correct":26},"正序负序零序并联",{"key":31,"text":586,"correct":22},"负序正序并联再和零序串联",{"id":588,"libraryId":5,"type":15,"typeLabel":16,"stem":589,"options":590,"answer":20,"analysis":33},420695,"110kv及以上电力系统应采用的中性点运行方式为（ ）。",[591,593,595,597],{"key":20,"text":592,"correct":26},"直接接地",{"key":24,"text":594,"correct":22},"不接地",{"key":28,"text":596,"correct":22},"经消弧线圈接地",{"key":31,"text":598,"correct":22},"不接地或经消弧线圈接地",[600,604,608,611,614,618],{"id":601,"name":602,"category":7,"favorite":603},256,"综合应用能力",6,{"id":605,"name":606,"category":7,"favorite":607},194,"《公安》基础知识+专业",5,{"id":609,"name":610,"category":7,"favorite":607},195,"政法干警",{"id":612,"name":613,"category":7,"favorite":607},255,"职业能力倾向测验",{"id":615,"name":616,"category":7,"favorite":617},212,"国家公务员-行政能力测试",4,{"id":619,"name":620,"category":7,"favorite":617},254,"公共基础知识"]