[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-197-12":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":564},{"id":5,"name":6,"category":7,"favorite":8},197,"电工类 (电网)","公务员",0,12,50,2675,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,201,209,221,233,245,253,261,269,277,285,296,304,315,327,339,351,363,375,387,399,408,416,423,434,442,449,461,473,485,496,508,520,530,540,552],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},420574,1,"单选题","三绕组升压变压器，居中绕组为（ ）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","高压绕组",false,{"key":24,"text":25,"correct":22},"B","中压绕组",{"key":27,"text":28,"correct":29},"C","低压绕组",true,{"key":31,"text":32,"correct":22},"D","依据电压等级不同，绕组的排列情况不同","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},420575,"架空输电线路的电纳与导线之间的几何平均距离的关系为（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"几何平均距离越大，电纳越大",{"key":24,"text":41,"correct":29},"几何平均距离越大，电纳越小",{"key":27,"text":43,"correct":22},"输电线路的电纳与几何平均距离无关",{"key":31,"text":45,"correct":22},"改变导线的几何平均距离可以明显改变线路的电纳",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":27,"analysis":33},420576,"运行中的电压互感器工作在（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"空载状态",{"key":24,"text":53,"correct":22},"短路状态",{"key":27,"text":55,"correct":29},"近似空载状态",{"key":31,"text":57,"correct":22},"近似短路状态",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},420577,"供电负荷加上厂用电之和称为（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"农业负荷",{"key":24,"text":65,"correct":29},"发电负荷",{"key":27,"text":67,"correct":22},"工业负荷",{"key":31,"text":69,"correct":22},"综合用电负荷",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},420579,"电压损耗是指线路的（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"始末两端电压的向量差",{"key":24,"text":77,"correct":22},"端部母线实际电压与额定电压的数值差",{"key":27,"text":79,"correct":22},"末端空载电压与负载电压的数值差",{"key":31,"text":81,"correct":29},"始末端电压数值差",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},420580,"对于供电可靠性，下述说法正确的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"所有负荷都应当做到在任何情况下不中断供电",{"key":24,"text":89,"correct":22},"一级和二级负荷应当在任何情况下不中断供电",{"key":27,"text":91,"correct":22},"除一级负荷不允许中断供电外，其他负荷随时可以中断供电",{"key":31,"text":93,"correct":29},"一级负荷在任何情况下都不允许中断供电，二级负荷应尽可能不停电，三级负荷可以根据系统运行情况随时停电",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},420582,"电力系统频率主要取决于（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"系统中的无功功率平衡",{"key":24,"text":101,"correct":29},"系统中的有功功率平衡",{"key":27,"text":103,"correct":22},"各节点电压的高低",{"key":31,"text":105,"correct":22},"各节点注入电流的大小",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":20,"analysis":33},420583,"线路串联电容的作用是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":29},"以其容抗抵偿线路的感抗",{"key":24,"text":113,"correct":22},"限流，避免该线路过载",{"key":27,"text":115,"correct":22},"产生环流或强制循环功率",{"key":31,"text":117,"correct":22},"提高暂态稳定",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":27,"analysis":33},420584,"安装并联电容器减少了传输线路上的（ ），从而降低线损。",[122,124,126,128],{"key":20,"text":123,"correct":22},"有功功率",{"key":24,"text":125,"correct":22},"电压",{"key":27,"text":127,"correct":29},"电流",{"key":31,"text":129,"correct":22},"电阻",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":27,"analysis":33},420585,"环形网络中自然功率的分布规律是（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":22},"与支路电阻成反比",{"key":24,"text":137,"correct":22},"与支路电导成反比",{"key":27,"text":139,"correct":29},"与支路阻抗成反比",{"key":31,"text":141,"correct":22},"与支路导纳成反比",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":24,"analysis":33},420586,"发电机在某一运行点运行时，受到小干扰后，发电机整步功率系数随功角增大而（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":22},"增大",{"key":24,"text":149,"correct":29},"减小",{"key":27,"text":151,"correct":22},"不变",{"key":31,"text":153,"correct":22},"不一定",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":24,"analysis":33},420587,"电力系统的电压频率等指标虽然发生变化，但是仍然在容许范围内，则此时电力系统是（ ）的。",[158,160,162,164],{"key":20,"text":159,"correct":22},"振荡",{"key":24,"text":161,"correct":29},"稳定",{"key":27,"text":163,"correct":22},"波动",{"key":31,"text":165,"correct":22},"不稳定",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":31,"analysis":33},420588,"定子与转子各绕组之间的互感系数（ ）。",[170,172,174,176],{"key":20,"text":171,"correct":22},"周期90°",{"key":24,"text":173,"correct":22},"周期180°",{"key":27,"text":175,"correct":22},"常数",{"key":31,"text":177,"correct":29},"周期360°",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":24,"analysis":33},420589,"电力系统中校验继电保护灵敏度的是（ ）。",[182,184,186,188],{"key":20,"text":183,"correct":22},"最大短路电流",{"key":24,"text":185,"correct":29},"最小短路电流",{"key":27,"text":187,"correct":22},"冲击电流",{"key":31,"text":189,"correct":22},"短路电流周期分量",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":27,"analysis":33},420590,"三相架空线相间距离越大，线路的导纳（ ）。",[194,195,197,199],{"key":20,"text":151,"correct":22},{"key":24,"text":196,"correct":22},"越大",{"key":27,"text":198,"correct":29},"越小",{"key":31,"text":200,"correct":22},"以上都有可能",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":24,"analysis":33},420591,"同一型号的导线，用在电压等级高的线路中要比用在电压等级低的线路中，电抗值（ ）",[205,206,207,208],{"key":20,"text":151,"correct":22},{"key":24,"text":147,"correct":29},{"key":27,"text":149,"correct":22},{"key":31,"text":200,"correct":22},{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":20,"analysis":33},420593,"电力弹性系数是指（ ）。",[213,215,217,219],{"key":20,"text":214,"correct":29},"电能消费增长速度与国民经济增长速度的比值。",{"key":24,"text":216,"correct":22},"电能消费增长速度与工业总产值增长速度的比值。",{"key":27,"text":218,"correct":22},"国民经济增长速度与电能消费增长速度的比值。",{"key":31,"text":220,"correct":22},"工业总产值增长速度与电能消费增长速度的比值。",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":24,"analysis":33},420594,"衡量电能质量的技术标准是（ ）。",[225,227,229,231],{"key":20,"text":226,"correct":22},"电压偏移、频率偏移、网损率",{"key":24,"text":228,"correct":29},"电压偏移、频率偏移、电压畸变率",{"key":27,"text":230,"correct":22},"厂用电率、燃料损耗率、网损率",{"key":31,"text":232,"correct":22},"厂用电率、网损率、电压畸变率",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":31,"analysis":33},420595,"（ ）没有专门的灭弧装置，它不能带负荷关合或拉开。",[237,239,241,243],{"key":20,"text":238,"correct":22},"负荷开关",{"key":24,"text":240,"correct":22},"断路器",{"key":27,"text":242,"correct":22},"自动开关",{"key":31,"text":244,"correct":29},"隔离开关",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":20,"analysis":33},420597,"线路停电时，断开断路器后，应（ ）。",[249,251],{"key":20,"text":250,"correct":29},"先断开线路侧隔离开关，后断开母线侧隔离开关",{"key":24,"text":252,"correct":22},"先断开母线侧隔离开关，后断开线路侧隔离开关",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":24,"analysis":33},420598,"三相二元件电能表不能用于（ ），否则少计电能。",[257,259],{"key":20,"text":258,"correct":22},"三相三线制系统",{"key":24,"text":260,"correct":29},"三相四线制系统",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":24,"analysis":33},420599,"利器切断低压电源线时，应用（ ）。",[265,267],{"key":20,"text":266,"correct":22},"有绝缘手柄的刀、斧、剪一次切断",{"key":24,"text":268,"correct":29},"有绝缘手柄的刀、斧、剪逐相切断",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":20,"analysis":33},420600,"凡是中性点接地的变压器在运行状态、充电状态，其中性点都必须可靠接地，在停用时（ ）。",[273,275],{"key":20,"text":274,"correct":29},"也必须接地",{"key":24,"text":276,"correct":22},"可以不接地",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":24,"analysis":33},420601,"断路器、隔离开关、接地开关在电气设备（线路）与电源接通时的操作顺序为（ ）。",[281,283],{"key":20,"text":282,"correct":22},"先合隔离开关，再断开接地开关，最后合上断路器",{"key":24,"text":284,"correct":29},"先断开接地开关，再合上隔离开关，最后合断路器",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":287,"answer":20,"analysis":33},420602,[288,290,292,294],{"key":20,"text":289,"correct":29},"高于",{"key":24,"text":291,"correct":22},"低于",{"key":27,"text":293,"correct":22},"等于",{"key":31,"text":295,"correct":22},"不能确定",{"id":297,"libraryId":5,"type":15,"typeLabel":16,"stem":298,"options":299,"answer":27,"analysis":33},420603,"中性点不直接接地系统，发生单相短路故障，非故障相电压上升为（ ）。",[300,301,302,303],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":29},{"key":31,"text":31,"correct":22},{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":306,"answer":24,"analysis":33},420604,[307,309,311,313],{"key":20,"text":308,"correct":22},"三相短路",{"key":24,"text":310,"correct":29},"两相短路",{"key":27,"text":312,"correct":22},"两相短路接地",{"key":31,"text":314,"correct":22},"单相接地短路",{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":31,"analysis":33},420605,"电力电缆停电时间超过试验周期的，必须做（ ）。",[319,321,323,325],{"key":20,"text":320,"correct":22},"交流耐压试验",{"key":24,"text":322,"correct":22},"直流耐压试验",{"key":27,"text":324,"correct":22},"接地电阻试验",{"key":31,"text":326,"correct":29},"标准预防性试验",{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":24,"analysis":33},420606,"对于输电线路，当P2R+Q2X＜0时，首端电压与末端电压之间的关系是（ ）",[331,333,335,337],{"key":20,"text":332,"correct":22},"末端电压低于首端电压",{"key":24,"text":334,"correct":29},"末端电压高于首端电压",{"key":27,"text":336,"correct":22},"末端电压等于首端电压",{"key":31,"text":338,"correct":22},"不能确定首末端电压之间的关系",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":20,"analysis":33},420607,"衡量电力系统运行系统运行经济性的主要指标是（ ）。",[343,345,347,349],{"key":20,"text":344,"correct":29},"燃料消耗率、厂用电率、网损率",{"key":24,"text":346,"correct":22},"燃料消耗率、建设投资、网损率",{"key":27,"text":348,"correct":22},"网损率、建设投资、电压畸变率",{"key":31,"text":350,"correct":22},"网损率、占地面积、建设投资",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":20,"analysis":33},420609,"高峰负荷时，允许电压中枢点电压略低，低谷负荷时允许电压中枢点略高，这种调压方式为（ ）。",[355,357,359,361],{"key":20,"text":356,"correct":29},"顺调压",{"key":24,"text":358,"correct":22},"逆调压",{"key":27,"text":360,"correct":22},"常调压",{"key":31,"text":362,"correct":22},"恒调压",{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":20,"analysis":33},420610,"变压器等值电路中，电导的物理意义表征的是（ ）。",[367,369,371,373],{"key":20,"text":368,"correct":29},"铁损",{"key":24,"text":370,"correct":22},"漏磁通",{"key":27,"text":372,"correct":22},"铜损",{"key":31,"text":374,"correct":22},"激磁阻抗",{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":27,"analysis":33},420611,"电力系统有功负荷的最优分配是针对（ ）进行的。",[379,381,383,385],{"key":20,"text":380,"correct":22},"一级负荷",{"key":24,"text":382,"correct":22},"二级负荷",{"key":27,"text":384,"correct":29},"三级负荷",{"key":31,"text":386,"correct":22},"四级负荷",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":24,"analysis":33},420612,"当电力系统中发生不对称故障时，破坏三相系统运行状态的对称性，这时可采用（ ）。",[391,393,395,397],{"key":20,"text":392,"correct":22},"运算曲线法",{"key":24,"text":394,"correct":29},"对称分量法",{"key":27,"text":396,"correct":22},"功角特性法",{"key":31,"text":398,"correct":22},"静特性分析法",{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":20,"analysis":33},420613,"系统频率上升将使负荷所需要的有功功率（ ）。",[403,404,405,406],{"key":20,"text":147,"correct":29},{"key":24,"text":149,"correct":22},{"key":27,"text":151,"correct":22},{"key":31,"text":407,"correct":22},"以上情况都有可能",{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":410,"options":411,"answer":27,"analysis":33},420614,"转子各绕组的自感系数（ ）。",[412,413,414,415],{"key":20,"text":171,"correct":22},{"key":24,"text":173,"correct":22},{"key":27,"text":175,"correct":29},{"key":31,"text":177,"correct":22},{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":418,"answer":24,"analysis":33},420615,[419,420,421,422],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":425,"answer":24,"analysis":33},420616,[426,428,430,432],{"key":20,"text":427,"correct":22},"网络的潮流分布可以调控",{"key":24,"text":429,"correct":29},"网络的潮流分布不可以调控",{"key":27,"text":431,"correct":22},"网络的潮流分布由线路长度决定",{"key":31,"text":433,"correct":22},"网络的潮流分布由线路阻抗确定",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":24,"analysis":33},420617,"对于两相短路附加阻抗M为（ ）。",[438,439,440,441],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":444,"answer":20,"analysis":33},420618,[445,446,447,448],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":31,"analysis":33},420619,"严禁带（ ）断、接引线。",[453,455,457,459],{"key":20,"text":454,"correct":22},"地线",{"key":24,"text":456,"correct":22},"重合闸",{"key":27,"text":458,"correct":22},"拉线",{"key":31,"text":460,"correct":29},"负荷",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":27,"analysis":33},420620,"关于中等长度线路下述说法中错误的是（ ）",[465,467,469,471],{"key":20,"text":466,"correct":22},"长度为100km～300km的架空输电线路属于中等长度线路",{"key":24,"text":468,"correct":22},"潮流计算中中等长度线路采用集中参数π型等值电路作为数学模型",{"key":27,"text":470,"correct":29},"潮流计算中中等长度线路可以忽略电导和电纳的影响",{"key":31,"text":472,"correct":22},"潮流计算中中等长度线路可以不考虑分布参数的影响",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":20,"analysis":33},420621,"电网中无功功率的流向是（ ）。",[477,479,481,483],{"key":20,"text":478,"correct":29},"从电压高的节点流向电压低的节点",{"key":24,"text":480,"correct":22},"从电压低的节点流向电压高的节点",{"key":27,"text":482,"correct":22},"从相位超前的节点流向相位滞后的节点",{"key":31,"text":484,"correct":22},"从相位滞后的节点流向相位超前的节点",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":24,"analysis":33},420622,"当同步发电机供给纯电容性负载时，电枢反应的作用是使其端电压（ ）。",[489,490,492,494],{"key":20,"text":151,"correct":22},{"key":24,"text":491,"correct":29},"增加",{"key":27,"text":493,"correct":22},"降低",{"key":31,"text":495,"correct":22},"不确定",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":31,"analysis":33},420625,"下面各组中完全属于系统参数的一组是（ ）。",[500,502,504,506],{"key":20,"text":501,"correct":22},"Z、P、U、k",{"key":24,"text":503,"correct":22},"Z、U、δ、k",{"key":27,"text":505,"correct":22},"Z、ω、f、k",{"key":31,"text":507,"correct":29},"R、X、Y、k",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":27,"analysis":33},420626,"高压导线断裂落地，距落地点（ ）范围内，救护人员不采取安全措施不能入内。",[512,514,516,518],{"key":20,"text":513,"correct":22},"4M",{"key":24,"text":515,"correct":22},"6M",{"key":27,"text":517,"correct":29},"8～10M",{"key":31,"text":519,"correct":22},"20M",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":20,"analysis":33},420628,"变压器绕组为A级绝缘，其最高允许温度为（ ）。",[524,526,528],{"key":20,"text":525,"correct":29},"105℃",{"key":24,"text":527,"correct":22},"120℃",{"key":27,"text":529,"correct":22},"130℃",{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":27,"analysis":33},420629,"高压鼠笼型交流电动机启动过程中，当大电流通过电阻液时，会使电阻液温度上升，启动（ ）。",[534,536,538],{"key":20,"text":535,"correct":22},"能量不变",{"key":24,"text":537,"correct":22},"能量变小",{"key":27,"text":539,"correct":29},"能量消耗大",{"id":541,"libraryId":5,"type":15,"typeLabel":16,"stem":542,"options":543,"answer":20,"analysis":33},420633,"电力系统稳态分析时，用电设备的数字模型通常是采用（ ）。",[544,546,548,550],{"key":20,"text":545,"correct":29},"恒功率模型",{"key":24,"text":547,"correct":22},"恒电压模型",{"key":27,"text":549,"correct":22},"恒电流模型",{"key":31,"text":551,"correct":22},"恒阻抗模型",{"id":553,"libraryId":5,"type":15,"typeLabel":16,"stem":554,"options":555,"answer":20,"analysis":33},420635,"同步发电机机端发生三相短路时，短路电流中包含的分量为（ ）。",[556,558,560,562],{"key":20,"text":557,"correct":29},"基频周期分量、非周期分量、倍频分量",{"key":24,"text":559,"correct":22},"基频周期分量、非周期分量",{"key":27,"text":561,"correct":22},"基频周期分量、倍频分量",{"key":31,"text":563,"correct":22},"非周期分量、倍频分量",[565,569,573,576,579,583],{"id":566,"name":567,"category":7,"favorite":568},256,"综合应用能力",6,{"id":570,"name":571,"category":7,"favorite":572},194,"《公安》基础知识+专业",5,{"id":574,"name":575,"category":7,"favorite":572},195,"政法干警",{"id":577,"name":578,"category":7,"favorite":572},255,"职业能力倾向测验",{"id":580,"name":581,"category":7,"favorite":582},212,"国家公务员-行政能力测试",4,{"id":584,"name":585,"category":7,"favorite":582},254,"公共基础知识"]