[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-197-11":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":516},{"id":5,"name":6,"category":7,"favorite":8},197,"电工类 (电网)","公务员",0,11,50,2675,[13,34,46,57,67,78,90,100,110,120,130,142,154,164,174,186,196,207,215,223,231,239,246,254,261,268,275,282,290,297,304,312,320,328,338,348,358,366,378,390,400,412,424,434,446,456,468,480,492,504],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},420512,1,"单选题","电力系统中相与相之间或相与地之间，通过电弧或其他较小阻抗形成的一种非正常连接称为（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","开路",false,{"key":24,"text":25,"correct":26},"B","短路",true,{"key":28,"text":29,"correct":22},"C","断路",{"key":31,"text":32,"correct":22},"D","虚接","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},420514,"三段式电流保护中（ ）构成线路的后备保护。",[38,40,42,44],{"key":20,"text":39,"correct":22},"瞬时电流速断保护",{"key":24,"text":41,"correct":22},"限时电流速断保护",{"key":28,"text":43,"correct":26},"定时限过电流保护",{"key":31,"text":45,"correct":22},"均可",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},420517,"靠近线路电源端与靠近线路负荷端的定时限过电流保护，动作时间相比（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":26},"靠近线路电源端整定值大",{"key":24,"text":53,"correct":22},"靠近线路负荷端整定值大",{"key":28,"text":55,"correct":22},"整定值相等",{"key":31,"text":45,"correct":22},{"id":58,"libraryId":5,"type":15,"typeLabel":16,"stem":59,"options":60,"answer":28,"analysis":33},420518,"我国继电保护技术发展过了五个阶段，其发展顺序是（ ）",[61,63,65],{"key":20,"text":62,"correct":22},"机电型、晶体管型、整流型、集成电路型、微机型",{"key":24,"text":64,"correct":22},"机电型、整流型、集成电路型、晶体管型、微机型",{"key":28,"text":66,"correct":26},"机电型、整流型、晶体管型、集成电路型、微机型",{"id":68,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":69,"answer":24,"analysis":33},420519,[70,72,74,76],{"key":20,"text":71,"correct":22},"该相自阻抗",{"key":24,"text":73,"correct":26},"该相正序阻抗",{"key":28,"text":75,"correct":22},"该相零序阻抗",{"key":31,"text":77,"correct":22},"该相负序阻抗",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":28,"analysis":33},420520,"变压器差动保护的差动元件通常采用比率制动特性，引入外部（ ）作为制动量。",[82,84,86,88],{"key":20,"text":83,"correct":22},"电压",{"key":24,"text":85,"correct":22},"功率",{"key":28,"text":87,"correct":26},"短路电流",{"key":31,"text":89,"correct":22},"阻抗",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":28,"analysis":33},420521,"从减小系统振荡的影响出发，距离保护的测量元件应采用（ ）。",[94,96,98],{"key":20,"text":95,"correct":22},"全阻抗继电器",{"key":24,"text":97,"correct":22},"方向阻抗继电器",{"key":28,"text":99,"correct":26},"偏移阻抗继电器",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":20,"analysis":33},420523,"瓦斯保护是变压器油箱内部故障的（ ）保护。",[104,106,108],{"key":20,"text":105,"correct":26},"主",{"key":24,"text":107,"correct":22},"近后备",{"key":28,"text":109,"correct":22},"远后备",{"id":111,"libraryId":5,"type":15,"typeLabel":16,"stem":112,"options":113,"answer":28,"analysis":33},420524,"从减少系统振荡的影响出发，距离保护的测量原件应采用（ ）。",[114,115,116,118],{"key":20,"text":95,"correct":22},{"key":24,"text":97,"correct":22},{"key":28,"text":117,"correct":26},"偏移特性阻抗继电器",{"key":31,"text":119,"correct":22},"圆阻抗继电器",{"id":121,"libraryId":5,"type":15,"typeLabel":16,"stem":122,"options":123,"answer":24,"analysis":33},420526,"双侧电源线路中的电流速断保护为提高灵敏性，方向元件应装在（ ）",[124,126,128],{"key":20,"text":125,"correct":22},"动作电流大的一侧",{"key":24,"text":127,"correct":26},"动作电流小的一侧",{"key":28,"text":129,"correct":22},"两侧",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":20,"analysis":33},420527,"电流互感器的主要作用是（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":26},"变换电流",{"key":24,"text":137,"correct":22},"变换电压",{"key":28,"text":139,"correct":22},"变换功率",{"key":31,"text":141,"correct":22},"变换电阻",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":20,"analysis":33},420529,"差动保护只能在被保护元件的内部故障时动作，而不反应外部故障，具有绝对（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":26},"选择性",{"key":24,"text":149,"correct":22},"速动性",{"key":28,"text":151,"correct":22},"灵敏性",{"key":31,"text":153,"correct":22},"可靠性",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":28,"analysis":33},420530,"方向闭锁高频保护发信机启动后，当判断为外部短路时，（ ）",[158,160,162],{"key":20,"text":159,"correct":22},"两侧发信机立即停信",{"key":24,"text":161,"correct":22},"两侧发信机继续发信",{"key":28,"text":163,"correct":26},"反方向一侧发信机继续发信",{"id":165,"libraryId":5,"type":15,"typeLabel":16,"stem":166,"options":167,"answer":24,"analysis":33},420531,"外部短路时，方向闭锁高频保护是靠（ ）来将两侧保护闭锁。",[168,170,172],{"key":20,"text":169,"correct":22},"两侧的发信机不发信",{"key":24,"text":171,"correct":26},"近故障点侧的发信机发信",{"key":28,"text":173,"correct":22},"远故障点侧的发信机发信",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":28,"analysis":33},420532,"具有二次谐波制动的差动保护，为了可靠躲过励磁涌流，可（ ）。",[178,180,182,184],{"key":20,"text":179,"correct":22},"增大“差动速断”动作电流的整定值",{"key":24,"text":181,"correct":22},"适当增大差动保护的二次谐波制动比",{"key":28,"text":183,"correct":26},"适当减小差动保护的二次谐波制动比",{"key":31,"text":185,"correct":22},"以上都不对",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":20,"analysis":33},420533,"双侧电源线路的过电流保护加方向元件是为了（ ）",[190,192,194],{"key":20,"text":191,"correct":26},"解决选择性",{"key":24,"text":193,"correct":22},"提高灵敏性",{"key":28,"text":195,"correct":22},"提高可靠性",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":20,"analysis":33},420534,"变压器低电压起动的过电流保护的电流元件接在变压器（ ）的电流互感器二次侧。",[200,202,204,206],{"key":20,"text":201,"correct":26},"电源侧",{"key":24,"text":203,"correct":22},"负荷侧",{"key":28,"text":205,"correct":22},"电源侧或者负荷侧",{"key":31,"text":185,"correct":22},{"id":208,"libraryId":5,"type":15,"typeLabel":16,"stem":209,"options":210,"answer":28,"analysis":33},420535,"以下不属于功率方向继电器90°接线方式的是（ ）。",[211,212,213,214],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":216,"libraryId":5,"type":15,"typeLabel":16,"stem":217,"options":218,"answer":28,"analysis":33},420536,"Yd-11接线变压器纵差动保护采用电流相位补偿接线后，星形侧电流互感器流入差动臂的电流是电流互感器二次电流的（ ）倍。",[219,220,221,222],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":225,"options":226,"answer":31,"analysis":33},420537,"在中性点直接接地电网中，零序功率方向继电器采用的接线方式是（ ）",[227,228,229,230],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":24,"analysis":33},420538,"对于Y，d11接线变压器，为保证正常运行时差动回路两臂的电流相等，应使变压器Y侧电流互感器变比（ ）",[235,236,237,238],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":240,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":241,"answer":24,"analysis":33},420539,[242,243,244,245],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":28,"analysis":33},420540,"电磁型电流继电器的动作条件是（ ）",[250,251,252,253],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":256,"answer":24,"analysis":33},420541,[257,258,259,260],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":263,"answer":31,"analysis":33},420542,[264,265,266,267],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":270,"answer":28,"analysis":33},420543,[271,272,273,274],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":276,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":277,"answer":31,"analysis":33},420544,[278,279,280,281],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":31,"analysis":33},420545,"对于y，d11接线变压器为保证正常运行时差动回路两臂的电流相等，应使变压器Y侧电流互感器变比（ ）。",[286,287,288,289],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":292,"answer":28,"analysis":33},420546,[293,294,295,296],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":298,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":299,"answer":28,"analysis":33},420547,[300,301,302,303],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":24,"analysis":33},420548,"阻抗继电器的精确工作电流是指（ ）。",[308,309,310,311],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":313,"libraryId":5,"type":15,"typeLabel":16,"stem":314,"options":315,"answer":20,"analysis":33},420549,"架空线路相序排列：高压线路是面对负荷方向，从左到右为（ ）。",[316,318],{"key":20,"text":317,"correct":26},"L1，L2，L3",{"key":24,"text":319,"correct":22},"L3，L2，L1",{"id":321,"libraryId":5,"type":15,"typeLabel":16,"stem":322,"options":323,"answer":20,"analysis":33},420550,"电压互感器接于线路上，当A相断开时（ ）。",[324,326],{"key":20,"text":325,"correct":26},"B相和C相的全电压与断相前差别不大",{"key":24,"text":327,"correct":22},"B相和C相的全电压与断相前差别较大",{"id":329,"libraryId":5,"type":15,"typeLabel":16,"stem":330,"options":331,"answer":24,"analysis":33},420551,"接地线为多股软铜线，其截面积不少于（ ）平方毫米。",[332,334,336],{"key":20,"text":333,"correct":22},"16",{"key":24,"text":335,"correct":26},"25",{"key":28,"text":337,"correct":22},"35",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":28,"analysis":33},420552,"一个电费结算期内的功率因数是按（ ）确定的。",[342,344,346],{"key":20,"text":343,"correct":22},"功率因数表",{"key":24,"text":345,"correct":22},"有功功率表和无功功率表",{"key":28,"text":347,"correct":26},"有功用电量和无功用电量",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":20,"analysis":33},420553,"架空线路夜间巡视周期为公网及专线每半年一次，其他线路（ ）一次。",[352,354,356],{"key":20,"text":353,"correct":26},"每年",{"key":24,"text":355,"correct":22},"每半年",{"key":28,"text":357,"correct":22},"每季",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":20,"analysis":33},420554,"接地线应采用多股软铜线，其截面积应符合短路电流的要求，但不得小于（ ）平方毫米。",[362,363,365],{"key":20,"text":335,"correct":26},{"key":24,"text":364,"correct":22},"30",{"key":28,"text":337,"correct":22},{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":24,"analysis":33},420555,"冲击系数kim的数值变化范围是（ ）。",[370,372,374,376],{"key":20,"text":371,"correct":22},"0≤kim≤1",{"key":24,"text":373,"correct":26},"1≤kim≤2",{"key":28,"text":375,"correct":22},"0≤kim≤2",{"key":31,"text":377,"correct":22},"1≤kim≤3",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":31,"analysis":33},420557,"某线路首段电压10.5kV，末端电压10.2kV，首段电压偏移百分数（ ）。",[382,384,386,388],{"key":20,"text":383,"correct":22},"2.86%",{"key":24,"text":385,"correct":22},"2.94%",{"key":28,"text":387,"correct":22},"3%",{"key":31,"text":389,"correct":26},"5%",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":24,"analysis":33},420558,"发电机作为电源一般将额定电压提高（ ），以补偿输电过程的电压损耗。",[394,395,396,398],{"key":20,"text":387,"correct":22},{"key":24,"text":389,"correct":26},{"key":28,"text":397,"correct":22},"10%",{"key":31,"text":399,"correct":22},"±5%",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":20,"analysis":33},420560,"500kV系统的平均额定电压为（ ）。",[404,406,408,410],{"key":20,"text":405,"correct":26},"525kV",{"key":24,"text":407,"correct":22},"520kV",{"key":28,"text":409,"correct":22},"515kV",{"key":31,"text":411,"correct":22},"500kV",{"id":413,"libraryId":5,"type":15,"typeLabel":16,"stem":414,"options":415,"answer":24,"analysis":33},420562,"我国工频电压的频率为（ ）。",[416,418,420,422],{"key":20,"text":417,"correct":22},"25Hz",{"key":24,"text":419,"correct":26},"50Hz",{"key":28,"text":421,"correct":22},"60Hz",{"key":31,"text":423,"correct":22},"220Hz",{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":24,"analysis":33},420563,"电力线路导线接头过热，首先应设法（ ），同时增加夜间巡视。",[428,430,432],{"key":20,"text":429,"correct":22},"增加巡视次数",{"key":24,"text":431,"correct":26},"减少该线路的负荷",{"key":28,"text":433,"correct":22},"该线路停电处理",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":28,"analysis":33},420566,"将一台双绕组升压变压器作降压变压器使用，假设高压侧实际运行电压不变，其低压侧实际电压与使用升压变压器相比（ ）。",[438,440,442,444],{"key":20,"text":439,"correct":22},"不变",{"key":24,"text":441,"correct":22},"升高",{"key":28,"text":443,"correct":26},"降低",{"key":31,"text":445,"correct":22},"以上都有可能",{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":24,"analysis":33},420567,"同一型号导线，在电压等级越高的线路中，其电抗值（ ）。",[450,451,453,455],{"key":20,"text":439,"correct":22},{"key":24,"text":452,"correct":26},"越大",{"key":28,"text":454,"correct":22},"越小",{"key":31,"text":445,"correct":22},{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":20,"analysis":33},420568,"A系统运行于50Hz，B系统运行于49.5Hz，两系统互联，则联络线上功率是（ ）。",[460,462,464,466],{"key":20,"text":461,"correct":26},"从A流向B",{"key":24,"text":463,"correct":22},"从B流向A",{"key":28,"text":465,"correct":22},"不会有功率流动",{"key":31,"text":467,"correct":22},"有功率流动但方向不确定",{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":28,"analysis":33},420569,"与一相断线故障复合序网形式上相同的短路故障是（ ）。",[472,474,476,478],{"key":20,"text":473,"correct":22},"单相接地短路",{"key":24,"text":475,"correct":22},"两相短路",{"key":28,"text":477,"correct":26},"两相短路接地",{"key":31,"text":479,"correct":22},"三相短路",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":28,"analysis":33},420571,"网络中某些节点的功率是由两侧向其流动，这种节点称为（ ）。",[484,486,488,490],{"key":20,"text":485,"correct":22},"电压分点",{"key":24,"text":487,"correct":22},"电流分点",{"key":28,"text":489,"correct":26},"功率分点",{"key":31,"text":491,"correct":22},"电抗分点",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":24,"analysis":33},420572,"以高压甚至超高压将发电厂、变电所或变电所之间连接起来的送电网络称为（ ）。",[496,498,500,502],{"key":20,"text":497,"correct":22},"发电网",{"key":24,"text":499,"correct":26},"输电网",{"key":28,"text":501,"correct":22},"配电网",{"key":31,"text":503,"correct":22},"以上都对",{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":20,"analysis":33},420573,"输电线路空载运行时，末端电压比首端电压（ ）。",[508,510,512,514],{"key":20,"text":509,"correct":26},"高",{"key":24,"text":511,"correct":22},"低",{"key":28,"text":513,"correct":22},"相等",{"key":31,"text":515,"correct":22},"以上情况都有可能",[517,521,525,528,531,535],{"id":518,"name":519,"category":7,"favorite":520},256,"综合应用能力",6,{"id":522,"name":523,"category":7,"favorite":524},194,"《公安》基础知识+专业",5,{"id":526,"name":527,"category":7,"favorite":524},195,"政法干警",{"id":529,"name":530,"category":7,"favorite":524},255,"职业能力倾向测验",{"id":532,"name":533,"category":7,"favorite":534},212,"国家公务员-行政能力测试",4,{"id":536,"name":537,"category":7,"favorite":534},254,"公共基础知识"]