[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-197-10":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":562},{"id":5,"name":6,"category":7,"favorite":8},197,"电工类 (电网)","公务员",0,10,50,2675,[13,34,46,58,70,80,90,102,114,126,138,150,162,174,186,194,206,218,230,241,249,255,266,272,279,291,302,311,323,335,347,359,371,382,394,406,418,427,435,447,459,469,481,491,499,511,521,532,544,552],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},420449,1,"单选题","实现输电电线路纵差保护必须考虑的中心问题是（ ）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","差动电流",false,{"key":24,"text":25,"correct":22},"B","励磁涌流",{"key":27,"text":28,"correct":29},"C","不平衡电流",true,{"key":31,"text":32,"correct":22},"D","冲击电流","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},420450,"变压器过负荷保护动作后（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":29},"延时动作于信号",{"key":24,"text":41,"correct":22},"跳开变压器各侧断路器",{"key":27,"text":43,"correct":22},"给出轻瓦斯信号",{"key":31,"text":45,"correct":22},"不跳开变压器断路器",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},420451,"变压器内部故障时，由于故障电流同样也会存在一定非周期分量，在使用速饱和变流器BLH后，纵差保护的动作速度（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"加快了",{"key":24,"text":53,"correct":29},"延迟了",{"key":27,"text":55,"correct":22},"不改变",{"key":31,"text":57,"correct":22},"不确定",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},420452,"对于大型发电机，反应转子表层过热的主保护是（ ）",[62,64,66,68],{"key":20,"text":63,"correct":22},"低电压起动的过电流保护",{"key":24,"text":65,"correct":22},"复合电压起动的过电流保护",{"key":27,"text":67,"correct":29},"负序电流保护",{"key":31,"text":69,"correct":22},"阻抗保护",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},420454,"在计算距离Ⅱ段保护定值时，分支系数Kb应取（ ）。",[74,76,78],{"key":20,"text":75,"correct":22},"最大值",{"key":24,"text":77,"correct":29},"最小值",{"key":27,"text":79,"correct":22},"1",{"id":81,"libraryId":5,"type":15,"typeLabel":16,"stem":82,"options":83,"answer":20,"analysis":33},420455,"在中性点非直接接地电网中的串联线路上发生跨线不同相两点接地短路时，三相完全星接线电流保护只切除远离电源故障点的几率为（ ）",[84,86,88],{"key":20,"text":85,"correct":29},"100%",{"key":24,"text":87,"correct":22},"2\u002F3",{"key":27,"text":89,"correct":22},"1\u002F3",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":24,"analysis":33},420458,"正方向出口相间短路，存在动作“死区”的阻抗继电器是（ ）",[94,96,98,100],{"key":20,"text":95,"correct":22},"全阻抗继电器",{"key":24,"text":97,"correct":29},"方向阻抗继电器",{"key":27,"text":99,"correct":22},"偏移特性阻抗继电器",{"key":31,"text":101,"correct":22},"上抛圆阻抗继电器",{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":24,"analysis":33},420459,"瓦斯保护时变压器的（ ）。",[106,108,110,112],{"key":20,"text":107,"correct":22},"主.后备保护",{"key":24,"text":109,"correct":29},"内部故障的主保护",{"key":27,"text":111,"correct":22},"外部故障的主保护",{"key":31,"text":113,"correct":22},"外部故障的后备保护",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":20,"analysis":33},420460,"双侧电源网中，母线两侧方向过电流保护的方向元件在（ ）可以省略。",[118,120,122,124],{"key":20,"text":119,"correct":29},"该保护的时限较长时",{"key":24,"text":121,"correct":22},"该保护的时限较短时",{"key":27,"text":123,"correct":22},"两侧保护的时限相等时",{"key":31,"text":125,"correct":22},"两侧保护的时限不等时",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":24,"analysis":33},420461,"距离Ⅱ段的动作值应按分支系数Kfz为最小的运行方式来确定，目的是为了保证保护的（ ）。",[130,132,134,136],{"key":20,"text":131,"correct":22},"速动性",{"key":24,"text":133,"correct":29},"选择性",{"key":27,"text":135,"correct":22},"灵敏性",{"key":31,"text":137,"correct":22},"可靠性",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":20,"analysis":33},420462,"按照规定，凡是X0\u002FX1（ ）的属于大接地电流系统。",[142,144,146,148],{"key":20,"text":143,"correct":29},"≤4.5",{"key":24,"text":145,"correct":22},"≥4.5",{"key":27,"text":147,"correct":22},"＞3",{"key":31,"text":149,"correct":22},"＜3",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":31,"analysis":33},420463,"作为高灵敏度的线路接地保护，零序电流灵敏Ⅰ段保护在非全相运行时需（ ）。",[154,156,158,160],{"key":20,"text":155,"correct":22},"投入运行",{"key":24,"text":157,"correct":22},"有选择性的投入运行",{"key":27,"text":159,"correct":22},"有选择性的退出运行",{"key":31,"text":161,"correct":29},"退出运行",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":31,"analysis":33},420464,"方向阻抗继电器的最大灵敏角是可以调节的。调节方法是（ ）",[166,168,170,172],{"key":20,"text":167,"correct":22},"改变电抗变压器UV原边匝数",{"key":24,"text":169,"correct":22},"改变电抗变压器副边匝数",{"key":27,"text":171,"correct":22},"改变电压变换器UR原边匝数",{"key":31,"text":173,"correct":29},"改变电抗变压器UR副边线圈中的电阻大小",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":27,"analysis":33},420465,"发电机单继电器式横差保护为防止励磁回路一点接地后发生瞬时性第二点接地引起保护误动作，采取的措施是（ ）",[178,180,182,184],{"key":20,"text":179,"correct":22},"接入TA",{"key":24,"text":181,"correct":22},"接入TV",{"key":27,"text":183,"correct":29},"接入KT",{"key":31,"text":185,"correct":22},"接入KOF",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":24,"analysis":33},420466,"电流速断保护定值不能保证（ ）时，则电流速断保护要误动作，需要加装方向元件。",[190,191,192,193],{"key":20,"text":131,"correct":22},{"key":24,"text":133,"correct":29},{"key":27,"text":135,"correct":22},{"key":31,"text":137,"correct":22},{"id":195,"libraryId":5,"type":15,"typeLabel":16,"stem":196,"options":197,"answer":20,"analysis":33},420467,"当发电厂采用单母线时，当母线上发生故障时，应由（ ）来动作跳闸。",[198,200,202,204],{"key":20,"text":199,"correct":29},"发电机的过电流保护",{"key":24,"text":201,"correct":22},"母线的过电流保护",{"key":27,"text":203,"correct":22},"母线的电流速断保护",{"key":31,"text":205,"correct":22},"母线的限时电流速断保护",{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":24,"analysis":33},420468,"限时电流速断保护的灵敏系数要求（ ）",[210,212,214,216],{"key":20,"text":211,"correct":22},"大于2",{"key":24,"text":213,"correct":29},"大于1.3～1.5",{"key":27,"text":215,"correct":22},"大于1.2",{"key":31,"text":217,"correct":22},"大于0.85",{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":24,"analysis":33},420469,"短距离输电线路比长距离输电线路受过渡电阻的影响要（ ）",[222,224,226,228],{"key":20,"text":223,"correct":22},"小",{"key":24,"text":225,"correct":29},"大",{"key":27,"text":227,"correct":22},"一样",{"key":31,"text":229,"correct":22},"不受影响",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":232,"answer":27,"analysis":33},420470,[233,235,237,239],{"key":20,"text":234,"correct":22},"正序电流",{"key":24,"text":236,"correct":22},"零序电流",{"key":27,"text":238,"correct":29},"负序电流",{"key":31,"text":240,"correct":22},"相电流",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":243,"answer":20,"analysis":33},420471,[244,245,246,247],{"key":20,"text":143,"correct":29},{"key":24,"text":145,"correct":22},{"key":27,"text":147,"correct":22},{"key":31,"text":248,"correct":22},"\u003C3",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":251,"answer":24,"analysis":33},420472,[252,253,254],{"key":20,"text":75,"correct":22},{"key":24,"text":77,"correct":29},{"key":27,"text":79,"correct":22},{"id":256,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":257,"answer":24,"analysis":33},420473,[258,260,262,264],{"key":20,"text":259,"correct":22},"该相自阻抗",{"key":24,"text":261,"correct":29},"该相正序阻抗",{"key":27,"text":263,"correct":22},"该相零序阻抗",{"key":31,"text":265,"correct":22},"该相负序阻抗",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":268,"answer":24,"analysis":33},420474,[269,270,271],{"key":20,"text":75,"correct":22},{"key":24,"text":77,"correct":29},{"key":27,"text":79,"correct":22},{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":274,"answer":24,"analysis":33},420475,[275,276,277,278],{"key":20,"text":259,"correct":22},{"key":24,"text":261,"correct":29},{"key":27,"text":263,"correct":22},{"key":31,"text":265,"correct":22},{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":24,"analysis":33},420477,"电流保护Ⅰ段的灵敏系数通常用保护范围来衡量，其保护范围越长表明保护越（ ）。",[283,285,287,289],{"key":20,"text":284,"correct":22},"可靠",{"key":24,"text":286,"correct":29},"灵敏",{"key":27,"text":288,"correct":22},"不可靠",{"key":31,"text":290,"correct":22},"不灵敏",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":27,"analysis":33},420478,"在短路故障发生后经过大约半个周期的时间，将出现短路电流的最大瞬时值，它是校验电气设备机械应力的一个重要参数，称此电流为（ ）。",[295,297,299,300],{"key":20,"text":296,"correct":22},"暂态电流",{"key":24,"text":298,"correct":22},"次暂态电流",{"key":27,"text":32,"correct":29},{"key":31,"text":301,"correct":22},"稳态电流",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":27,"analysis":33},420480,"不属于继电保护基本要求的是（ ）。",[306,307,308,310],{"key":20,"text":137,"correct":22},{"key":24,"text":133,"correct":22},{"key":27,"text":309,"correct":29},"有效性",{"key":31,"text":131,"correct":22},{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":31,"analysis":33},420481,"下列不属于变压器差动电保护不平衡电流来源的是（ ）。",[315,317,319,321],{"key":20,"text":316,"correct":22},"计算变比与实际变比不一致",{"key":24,"text":318,"correct":22},"变压器带负荷调节分接头",{"key":27,"text":320,"correct":22},"电流互感器传变误差",{"key":31,"text":322,"correct":29},"电流互感器二次侧负载小",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":31,"analysis":33},420483,"关于励磁涌流间断角，下列说法不正确的是（ ）。",[327,329,331,333],{"key":20,"text":328,"correct":22},"间断角是区别励磁涌流和故障电流的重要特征",{"key":24,"text":330,"correct":22},"饱和越严重，间断角越小",{"key":27,"text":332,"correct":22},"检测差电流波形是否存在间断角，当间断角大于整定值时将差动保护闭锁",{"key":31,"text":334,"correct":29},"间断角鉴别方法属于频域特征鉴别",{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":31,"analysis":33},420484,"关于速饱和中间变流器，下列说法不正确的是（ ）。",[339,341,343,345],{"key":20,"text":340,"correct":22},"速饱和中间变流器采用很容易饱和的铁芯",{"key":24,"text":342,"correct":22},"速饱和中间变流器能够大大减少电流互感器的暂态不平衡电流",{"key":27,"text":344,"correct":22},"速饱和中间变流器无法识别对称性励磁涌流",{"key":31,"text":346,"correct":29},"速饱和原理的纵差动保护动作电流小，灵敏度高",{"id":348,"libraryId":5,"type":15,"typeLabel":16,"stem":349,"options":350,"answer":24,"analysis":33},420486,"关于励磁涌流谐波，下列说法不正确的是（ ）。",[351,353,355,357],{"key":20,"text":352,"correct":22},"励磁涌流含有大量二次谐波",{"key":24,"text":354,"correct":29},"谐波制动方法属于时域特征鉴别",{"key":27,"text":356,"correct":22},"三相励磁涌流中至少有一相励磁涌流谐波含量较高",{"key":31,"text":358,"correct":22},"检测差电流中谐波含量大于整定值时，将差动保护闭锁",{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":27,"analysis":33},420488,"当继电器刚好动作时，加入继电器中的电压和电流的比值成为继电器的（ ）。",[363,365,367,369],{"key":20,"text":364,"correct":22},"测量阻抗",{"key":24,"text":366,"correct":22},"整定阻抗",{"key":27,"text":368,"correct":29},"起动阻抗",{"key":31,"text":370,"correct":22},"零序阻抗",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":24,"analysis":33},420489,"电力系统中母线和变压器发生故障，一般（ ）重合闸。",[375,377,379,381],{"key":20,"text":376,"correct":22},"必须采用",{"key":24,"text":378,"correct":29},"不采用",{"key":27,"text":380,"correct":22},"根据实际情况采用",{"key":31,"text":57,"correct":22},{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":24,"analysis":33},420490,"对发电机、变压器、断路器、母线、输电线路等用电设备的状态进行监视、测量、控制和保护的设备，称为电力系统的（ ）。",[386,388,390,392],{"key":20,"text":387,"correct":22},"一次设备",{"key":24,"text":389,"correct":29},"二次设备",{"key":27,"text":391,"correct":22},"用电设备",{"key":31,"text":393,"correct":22},"多元设备",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":27,"analysis":33},420491,"关于对称性励磁涌流，下列说法不正确的是（ ）。",[398,400,402,404],{"key":20,"text":399,"correct":22},"三相变压器中才可能出现对称性励磁涌流",{"key":24,"text":401,"correct":22},"对称性励磁涌流中无非周期分量",{"key":27,"text":403,"correct":29},"对称性励磁涌流的波宽为180°",{"key":31,"text":405,"correct":22},"对称性励磁涌流的间断角最小",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":31,"analysis":33},420492,"短路的类型不包括（ ）。",[410,412,414,416],{"key":20,"text":411,"correct":22},"单相接地短路",{"key":24,"text":413,"correct":22},"两相短路",{"key":27,"text":415,"correct":22},"两相短路接地",{"key":31,"text":417,"correct":29},"三相短路接地",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":31,"analysis":33},420493,"对称短路的类型包括（ ）。",[422,423,424,425],{"key":20,"text":411,"correct":22},{"key":24,"text":413,"correct":22},{"key":27,"text":415,"correct":22},{"key":31,"text":426,"correct":29},"三相短路",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":27,"analysis":33},420494,"继电保护的基本要求不包括（ ）。",[431,432,433,434],{"key":20,"text":137,"correct":22},{"key":24,"text":133,"correct":22},{"key":27,"text":309,"correct":29},{"key":31,"text":131,"correct":22},{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":20,"analysis":33},420495,"在自动重合闸中，后记忆元件的作用是（ ）。",[439,441,443,445],{"key":20,"text":440,"correct":29},"将脉冲展宽",{"key":24,"text":442,"correct":22},"减小测量误差",{"key":27,"text":444,"correct":22},"有延时作用",{"key":31,"text":446,"correct":22},"以上都不对",{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":27,"analysis":33},420496,"在给方向阻抗继电器的电流、电压线圈接入电流电压时，一定要注意不要接错极性，如果接错极性，会发生方向阻抗继电器（ ）的后果。",[451,453,455,457],{"key":20,"text":452,"correct":22},"拒动",{"key":24,"text":454,"correct":22},"误动",{"key":27,"text":456,"correct":29},"正向故障拒动或反向故障误动",{"key":31,"text":458,"correct":22},"损坏",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":20,"analysis":33},420497,"电流速断保护的动作电流应大于（ ）",[463,465,467],{"key":20,"text":464,"correct":29},"被保护线路末端短路时的最大短路电流",{"key":24,"text":466,"correct":22},"线路的最大负载电流",{"key":27,"text":468,"correct":22},"相邻下一段路末端短路时的最大短路电流",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":20,"analysis":33},420498,"当系统频率高于额定频率时，方向阻抗继电器最大灵敏度（ ）。",[473,475,477,479],{"key":20,"text":474,"correct":29},"变大",{"key":24,"text":476,"correct":22},"变小",{"key":27,"text":478,"correct":22},"不变",{"key":31,"text":480,"correct":22},"与系统频率变化无关",{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":20,"analysis":33},420501,"距离保护第Ⅲ段不加振荡闭锁是因为（ ）",[485,487,489],{"key":20,"text":486,"correct":29},"Ⅲ段带较长延时，可躲过振荡",{"key":24,"text":488,"correct":22},"电力系统振荡对Ⅲ段没有影响",{"key":27,"text":490,"correct":22},"Ⅲ段在电力系统振荡时不会启动",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":20,"analysis":33},420503,"在距离保护中，加入继电器中的电压U和电流I的比值成为阻抗继电器的（ ）。",[495,496,497,498],{"key":20,"text":364,"correct":29},{"key":24,"text":366,"correct":22},{"key":27,"text":368,"correct":22},{"key":31,"text":370,"correct":22},{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":20,"analysis":33},420504,"由于过渡电阻的存在，一般情况下使阻抗继电器的（ ）",[503,505,507,509],{"key":20,"text":504,"correct":29},"测量阻抗增大，保护范围减小",{"key":24,"text":506,"correct":22},"测量阻抗增大，保护范围增大",{"key":27,"text":508,"correct":22},"测量阻抗减小，保护范围减小",{"key":31,"text":510,"correct":22},"测量阻抗减小，保护范围增大",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":20,"analysis":33},420505,"变压器的励磁涌流中，含有大量的直流分量及高次谐波分量，其中以（ ）次谐波所占的比例最大。",[515,517,519],{"key":20,"text":516,"correct":29},"二",{"key":24,"text":518,"correct":22},"三",{"key":27,"text":520,"correct":22},"五",{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":523,"answer":27,"analysis":33},420507,[524,526,528,530],{"key":20,"text":525,"correct":22},"滞后于C相电压一线路阻抗角",{"key":24,"text":527,"correct":22},"滞后于B相电压一线路阻抗角",{"key":27,"text":529,"correct":29},"滞后于BC相电压一线路阻抗角",{"key":31,"text":531,"correct":22},"滞后于A相电压一线路阻抗角",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":27,"analysis":33},420508,"低压侧不带电源的降压变压器，（ ）装设自动重合闸。",[536,538,540,542],{"key":20,"text":537,"correct":22},"不需要",{"key":24,"text":539,"correct":22},"必须",{"key":27,"text":541,"correct":29},"视情况而定",{"key":31,"text":543,"correct":22},"参考其他数据",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":27,"analysis":33},420510,"在校验距离Ⅲ段保护远后备灵敏系数时，分支系数取最大值是为了满足保护的（ ）",[548,549,550,551],{"key":20,"text":133,"correct":22},{"key":24,"text":131,"correct":22},{"key":27,"text":135,"correct":29},{"key":31,"text":137,"correct":22},{"id":553,"libraryId":5,"type":15,"typeLabel":16,"stem":554,"options":555,"answer":24,"analysis":33},420511,"定时限过电流保护的动作电流需要考虑返回系数，是为了（ ）",[556,558,560],{"key":20,"text":557,"correct":22},"提高保护的灵敏性",{"key":24,"text":559,"correct":29},"外部故障切除后保护可靠返回",{"key":27,"text":561,"correct":22},"解决选择性",[563,567,571,574,577,581],{"id":564,"name":565,"category":7,"favorite":566},256,"综合应用能力",6,{"id":568,"name":569,"category":7,"favorite":570},194,"《公安》基础知识+专业",5,{"id":572,"name":573,"category":7,"favorite":570},195,"政法干警",{"id":575,"name":576,"category":7,"favorite":570},255,"职业能力倾向测验",{"id":578,"name":579,"category":7,"favorite":580},212,"国家公务员-行政能力测试",4,{"id":582,"name":583,"category":7,"favorite":580},254,"公共基础知识"]