[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-422952":3},{"question":4,"library":20},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":17,"analysis":19},422952,197,3,"判断题","变压器过励磁现象指的是，超高压远距离输电线路由于突然使其负荷而造成变压器过电压时铁芯饱和，励磁电流大大增加。与变压器励磁涌流时现象相同。（ ）",[11,15],{"key":12,"text":13,"correct":14},"A","正确",false,{"key":16,"text":17,"correct":18},"B","错误",true,"变压器过励磁现象与变压器空载合闸时励磁涌流不同，过励磁时变压器铁芯的饱和是对称的，励磁电流中有较大的五次等奇次谐波，没有间断和偶次谐波。",{"id":6,"name":21,"category":22,"favorite":23},"电工类 (电网)","公务员",0]