[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-168-7":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":614},{"id":5,"name":6,"category":7,"favorite":8},168,"(高级)网络规划设计师","职业资格",0,7,50,817,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,250,262,274,286,298,310,322,330,340,352,364,376,388,400,412,424,436,448,460,472,484,496,508,520,532,544,556,568,580,591,603],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},386676,1,"单选题","TCP协议在工作过程中存在死锁的可能，其发生的原因是（ ）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","多个进程请求未被释放的资源",false,{"key":24,"text":25,"correct":22},"B","一个连接还未释放，又请求新的连接",{"key":27,"text":28,"correct":29},"C","接收方发送0窗口的应答报文后，所发送的非0窗口应答报文丢失",true,{"key":31,"text":32,"correct":22},"D","定义RTT值为2倍的测量值不恰当","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},386677,"在Windows系统中监听发送给NT主机的陷入报文的程序是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"snmp.exe",{"key":24,"text":41,"correct":22},"mspaint.com",{"key":27,"text":43,"correct":22},"notepad.exe",{"key":31,"text":45,"correct":29},"snmptrap.exe",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":27,"analysis":33},386678,"TCP的标记部分包含的字段（请作答此空）表示含义是重新连接。",[50,52,54,56],{"key":20,"text":51,"correct":22},"ACK",{"key":24,"text":53,"correct":22},"SYN",{"key":27,"text":55,"correct":29},"RST",{"key":31,"text":57,"correct":22},"PSH",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},386679,"在一次TCP连接中，如果某方要关闭连接，这时应答方则应该在收到该报文后， （） 。",[62,64,66,68],{"key":20,"text":63,"correct":22},"在对该报文进行肯定确认后，同时马上发送关闭连接报文",{"key":24,"text":65,"correct":22},"只需对该报文进行肯定确认",{"key":27,"text":67,"correct":29},"在发该报文进行肯定确认后，应该收到应用程序通知后再发送关闭连接报文",{"key":31,"text":69,"correct":22},"无需对其做出任何应答",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},386680,"PGP提供的是( )安全。",[74,76,78,80],{"key":20,"text":75,"correct":22},"物理层",{"key":24,"text":77,"correct":22},"网络层",{"key":27,"text":79,"correct":22},"传输层",{"key":31,"text":81,"correct":29},"应用层",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},386681,"TCP 协议使用三次握手机制建立连接，其中被请求方在第二次握手时需应答的关键信息及其作用是（ ） 。",[86,88,90,92],{"key":20,"text":87,"correct":29},"确认号是发起方设定的初始序号加1之后的数值，确认被请求者的身份",{"key":24,"text":89,"correct":22},"确认号是发起方设定的初始序号+1，确认发起方的身份",{"key":27,"text":91,"correct":22},"确认号是被请求者设定的初始序号+1，同步将要接收的数据流编号",{"key":31,"text":93,"correct":22},"确认号是被请求者设定的初始序号+1，确认发起方的身份",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":27,"analysis":33},386682,"HDLC通信中，（ ）用于传送有效信息或数据，简称（ ）。SNRM属于HDLC帧中的（请作答此空）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"I帧",{"key":24,"text":101,"correct":22},"S帧",{"key":27,"text":103,"correct":29},"U帧",{"key":31,"text":105,"correct":22},"N帧",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},386683,"SNMPv2提供了3种访问管理信息的方法，这3种方法不包括（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"管理站向代理发出通信请求",{"key":24,"text":113,"correct":29},"代理向管理站发出通信请求",{"key":27,"text":115,"correct":22},"管理站与管理站之间的通信",{"key":31,"text":117,"correct":22},"代理向管理站发送陷入报文",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":31,"analysis":33},386684,"FTP客户上传文件时，通过服务器20端口建立的连接是 （ ） ，FTP客户端应用进程的端口可以为 （请作答此空） 。",[122,124,126,128],{"key":20,"text":123,"correct":22},"20",{"key":24,"text":125,"correct":22},"21",{"key":27,"text":127,"correct":22},"80",{"key":31,"text":129,"correct":29},"4155",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},386685,"搭建试验平台、进行网络仿真是网络生命周期中（ ）阶段的任务。",[134,136,138,140],{"key":20,"text":135,"correct":22},"需求规范",{"key":24,"text":137,"correct":29},"逻辑网络设计",{"key":27,"text":139,"correct":22},"物理网络设计",{"key":31,"text":141,"correct":22},"实施",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":20,"analysis":33},386686,"主机host1对host2进行域名查询的过程如下图所示，下列说法中正确的是( )",[146,148,150,152],{"key":20,"text":147,"correct":29},"本地域名服务器采用递归算法",{"key":24,"text":149,"correct":22},"中介域名服务器采用迭代算法",{"key":27,"text":151,"correct":22},"根域名服务器采用递归算法",{"key":31,"text":153,"correct":22},"本地域名服务器采用迭代算法,中介域名服务器采用迭代算法",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":24,"analysis":33},386687,"计算机网络机房建设中，为了屏蔽外界干扰、漏电及电火花等，要求所有计算机网络设备的机箱、机柜、机壳等都需接地，该接地系统称为安全地，安全地接地电阻要求小于（ ）。",[158,160,162,164],{"key":20,"text":159,"correct":22},"1Ω",{"key":24,"text":161,"correct":29},"4Ω",{"key":27,"text":163,"correct":22},"5Ω",{"key":31,"text":165,"correct":22},"10Ω",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":27,"analysis":33},386688,"RUP生命周期阶段中（ ）阶段是构件与应用集成为产品，并通过详细测试。",[170,172,174,176],{"key":20,"text":171,"correct":22},"初始阶段",{"key":24,"text":173,"correct":22},"细化阶段",{"key":27,"text":175,"correct":29},"构建阶段",{"key":31,"text":177,"correct":22},"交付阶段",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":27,"analysis":33},386689,"层次化编址是一种对地址进行结构化设计的模型，关于在编址和路由选择模型中使用层次化模型，以下说法不正确的是（ ）。",[182,184,186,188],{"key":20,"text":183,"correct":22},"易于排查故障",{"key":24,"text":185,"correct":22},"易于管理和性能优化",{"key":27,"text":187,"correct":29},"需占用较多资源",{"key":31,"text":189,"correct":22},"加快路由选择协议收敛",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":20,"analysis":33},386690,"以下关于敏捷方法的叙述中，错误的是（ ）。",[194,196,198,200],{"key":20,"text":195,"correct":29},"敏捷型方法是预设性而非适应性的开发方法",{"key":24,"text":197,"correct":22},"敏捷型方法最优先要做的是尽早地、持续地交付有价值的软件，让客户满意",{"key":27,"text":199,"correct":22},"敏捷型方法认为简单是最根本的要求",{"key":31,"text":201,"correct":22},"敏捷开发方法认为即使到了开发的后期，也欢迎改变需求",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":27,"analysis":33},386691,"网络生命周期的迭代模型的四阶段模型，顾名思义分为四个阶段，其中（ ）不属于该迭代模型。（请作答此空）的工作在于根据设计方案进行设备购置、安装、调试，形成可试用的网络环境。以下特点中，不属于该阶段模型优缺点的是（ ）。",[206,208,210,212],{"key":20,"text":207,"correct":22},"分析与设计阶段",{"key":24,"text":209,"correct":22},"需求与计划阶段",{"key":27,"text":211,"correct":29},"实施与构建阶段",{"key":31,"text":213,"correct":22},"运行与维护阶段",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":27,"analysis":33},386692,"甲公司承接了乙公司的网络建设工作。由于待建网络规模很大，为确保建设工作顺利进行，负责该项目的工程师在进行逻辑设计时提出了如下工作思路： ①明确逻辑设计工作的内容是：网络拓扑结构设计；物理层技术选择；局域网技术选择；广域网技术选择；地址设计；路由协议选择；网络管理模式与工具选择；撰写逻辑设计文档。 ②在进行地址设计时，确定的方案是：按乙公司各分支机构的地理位置划分地址块，并按10.n.X .Y \u002F16的模式分配，其中n为分支机构的序号（0表示公司总部，分支机构总数不会超过200）。 对该工程师确定的逻辑设计内容的评价，恰当的是应增加网络安全设计这一部分。 每个分支机构能连网的计算机的数量最多为（）",[218,220,222,224],{"key":20,"text":219,"correct":22},"16",{"key":24,"text":221,"correct":22},"256",{"key":27,"text":223,"correct":29},"65534",{"key":31,"text":225,"correct":22},"65536",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":20,"analysis":33},386693,"某政府机构拟建设一个网络，委托甲公司承建。甲公司的张工程师带队去进行需求调研，在与委托方会谈过程中记录了大量信息，其中主要内容有：用户计算机数量：80台；业务类型：政务办公，在办公时不允许连接Internet；分布范围：分布在一栋四层楼房内；最远距离：约80米；该网络通过专用光纤与上级机关的政务网相连；网络建设时间：三个月。 张工据此撰写了需求分析报告，与常规网络建设的需求分析报告相比，该报告的最大不同之处应该是（） 。为此，张工在需求报告中特别强调应增加预算，以采购性能优越的进口设备。",[230,232,234,236],{"key":20,"text":231,"correct":29},"网络隔离需求",{"key":24,"text":233,"correct":22},"网络速度需求",{"key":27,"text":235,"correct":22},"文件加密需求",{"key":31,"text":237,"correct":22},"邮件安全需求",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":20,"analysis":33},386694,"建筑物综合布线系统中工作区子系统是指（ ）。",[242,244,246,248],{"key":20,"text":243,"correct":29},"由终端到信息插座之间的连线系统",{"key":24,"text":245,"correct":22},"楼层接线间的配线架和线缆系统",{"key":27,"text":247,"correct":22},"各楼层设备之间的互连系统",{"key":31,"text":249,"correct":22},"连接各个建筑物的通信系统",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":24,"analysis":33},386695,"某单位在进行新园区网络规划设计时，考虑选用的关键设备都是国内外知名公司的产品，在系统结构化布线、设备安装、机房装修等环节严格按照现行国内外相关技术标准或规范来执行。该单位在网络设计时遵循了（ ）原则。",[254,256,258,260],{"key":20,"text":255,"correct":22},"先进性",{"key":24,"text":257,"correct":29},"可靠性与稳定性",{"key":27,"text":259,"correct":22},"可扩充",{"key":31,"text":261,"correct":22},"实用性",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":27,"analysis":33},386696,"以下关于网络规划设计过程叙述中，属于设计优化阶段任务是（ ）。",[266,268,270,272],{"key":20,"text":267,"correct":22},"通过与用户交流分析当前和未来网络的流量、负载",{"key":24,"text":269,"correct":22},"完成网络设备命名、交换及路由协议选择、网络管理等设计",{"key":27,"text":271,"correct":29},"通过召开专家研讨会、搭建试验平台、网络仿真等多种形式，找出设计方案中的缺陷，并改进方案",{"key":31,"text":273,"correct":22},"根据优化后的方案进行设备的购置、安装、调试与测试",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":24,"analysis":33},386697,"某公司主营证券与期货业务，有多个办公网点，要求企业内部用户能够高速地访问企业服务器，并且对网络的可靠性要求很高。工程师给出设计方案：①采用核心层、汇聚层、接入层三层结构；②骨干网使用千兆以太网；③为了不改变已有建筑的结构，部分网点采用WLAN组网；④根据企业需求，将网络拓扑设计为双核心来进行负载均衡，当其中一个核心交换机出现故障时，数据能够转换到另一台交换上，起到冗余备份的作用。网络拓扑如下图所示。 针对网络的拓扑设计，你的评价是（ ） 。",[278,280,282,284],{"key":20,"text":279,"correct":22},"恰当合理",{"key":24,"text":281,"correct":29},"不恰当，2个核心交换机都应直接上联到路由器上，保证网络的可靠性",{"key":27,"text":283,"correct":22},"不恰当，为保证高速交换，接入层应使用三层交换机",{"key":31,"text":285,"correct":22},"不恰当，为保证核心层高速交换，服务器应放在接入层",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":31,"analysis":33},386698,"工程师利用某种测试设备在每个信息点对已经连接好的网线进行测试时，发现每个UTP中都有几根线的长度不正确，以为是RJ45接头做得不好，于是重做RJ45接头，但现象依旧。经检查，测试设备无故障。其原因是（） 。",[290,292,294,296],{"key":20,"text":291,"correct":22},"测试设备与测试环境不符",{"key":24,"text":293,"correct":22},"测试人员不会使用测试设备",{"key":27,"text":295,"correct":22},"未连接计算机",{"key":31,"text":297,"correct":29},"对端连接了交换机",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":24,"analysis":33},386699,"对网络性能进行评估时，需要明确的主要性能指标是实际数据率，除了可用理论方法进行分析外，更多地需要进行实际测量，主要的测量方法是（）",[302,304,306,308],{"key":20,"text":303,"correct":22},"用速率测试仪，测试线路速率",{"key":24,"text":305,"correct":29},"运行测试程序，发送大量数据，观察实际性能值",{"key":27,"text":307,"correct":22},"收集网络上传输过程的全部信息，进行分析",{"key":31,"text":309,"correct":22},"将用户程序放在不同网络上运行，比较所需时间",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":20,"analysis":33},386701,"某机构拟建设一个网络，委托甲公司承建。甲公司的赵工程师带队去进行需求调研，在与委托方会谈过程中记录了大量信息，经过整理，归纳出如下主要内容：用户计算机数量：97台；业务类型：办公；连接Internet需要；分布范围：分布在一栋楼房的三层内（另附位置图一张）；最远距离：78米；需要的网络服务：邮件、Web；网络建设时间：三个月。 在撰写需求分析报告时，发现缺少了一些很重要的信息，其中包括（7）",[314,316,318,320],{"key":20,"text":315,"correct":29},"估计的通信量",{"key":24,"text":317,"correct":22},"计算机的性能",{"key":27,"text":319,"correct":22},"经费预算",{"key":31,"text":321,"correct":22},"应用系统的运行平台",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":31,"analysis":33},386702,"计算机网络机房建设过程中，独立的防雷保护接地电阻要求小于（ ）。",[326,327,328,329],{"key":20,"text":159,"correct":22},{"key":24,"text":161,"correct":22},{"key":27,"text":163,"correct":22},{"key":31,"text":165,"correct":29},{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":27,"analysis":33},386703,"在五阶段网络开发过程中，网络物理结构图和布线方案的确定是在（ ）阶段确定的。",[334,336,337,338],{"key":20,"text":335,"correct":22},"需求分析",{"key":24,"text":137,"correct":22},{"key":27,"text":139,"correct":29},{"key":31,"text":339,"correct":22},"通信规范设计",{"id":341,"libraryId":5,"type":15,"typeLabel":16,"stem":342,"options":343,"answer":24,"analysis":33},386704,"甲公司承接了乙公司的网络建设工作。由于待建网络规模很大，为确保建设工作顺利进行，负责该项目的工程师在进行逻辑设计时提出了如下工作思路： ①明确逻辑设计工作的内容是：网络拓扑结构设计；物理层技术选择；局域网技术选择；广域网技术选择；地址设计；路由协议选择；网络管理模式与工具选择；撰写逻辑设计文档。 ②在进行地址设计时，确定的方案是：按乙公司各分支机构的地理位置划分地址块，并按10.n.X .Y \u002F16的模式分配，其中n为分支机构的序号（0表示公司总部，分支机构总数不会超过200）。 对该工程师确定的逻辑设计内容的评价，恰当的是应增加网络安全设计这一部分。 每个分支机构能连网的计算机的数量最多为65534，配置IP地址时掩码是（3）。",[344,346,348,350],{"key":20,"text":345,"correct":22},"255.0.0.0",{"key":24,"text":347,"correct":29},"255.255.0.0",{"key":27,"text":349,"correct":22},"255.255.255.0",{"key":31,"text":351,"correct":22},"255.255.240.0",{"id":353,"libraryId":5,"type":15,"typeLabel":16,"stem":354,"options":355,"answer":31,"analysis":33},386705,"某政府机构拟建设一个网络，委托甲公司承建。甲公司的张工程师带队去进行需求调研，在与委托方会谈过程中记录了大量信息，其中主要内容有：用户计算机数量：80台；业务类型：政务办公，在办公时不允许连接Internet；分布范围：分布在一栋四层楼房内；最远距离：约80米；该网络通过专用光纤与上级机关的政务网相连；网络建设时间：三个月。 张工据此撰写了需求分析报告，与常规网络建设的需求分析报告相比，该报告的最大不同之处是 网络隔离需求。为此，张工在需求报告中特别强调应增加预算，以采购性能优越的进口设备。该需求分析报告（） 。",[356,358,360,362],{"key":20,"text":357,"correct":22},"恰当，考虑周全",{"key":24,"text":359,"correct":22},"不很恰当，因现有预算足够买国产设备",{"key":27,"text":361,"correct":22},"不恰当，因无需增加预算也能采购到好的进口设备",{"key":31,"text":363,"correct":29},"不恰当，因政务网的关键设备不允许使用进口设备",{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":31,"analysis":33},386706,"关于干线子系统的说法，正确的有（ ）",[368,370,372,374],{"key":20,"text":369,"correct":22},"对于旧式建筑，利用建筑物的线井进行铺设",{"key":24,"text":371,"correct":22},"对于新式建筑物，主要利用楼层牵引管进行铺设",{"key":27,"text":373,"correct":22},"干线子系统是建筑物内网络系统的中枢，只实现各楼层的工作区子系统之间的互联",{"key":31,"text":375,"correct":29},"干线子系统通常由垂直大对数铜缆或光缆组成，一端端接于设备机房的主配线架上，另一端通常端接在楼层接线间的各个管理分配线架上",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":24,"analysis":33},386707,"MPLS是一种更通用的QoS保证机制，其基本思想可简述为（）",[380,382,384,386],{"key":20,"text":381,"correct":22},"标记交换路由器为IP分组加上标记，其它路由器按优先级转发",{"key":24,"text":383,"correct":29},"边缘路由器对业务流进行分类并填写标志，核心路由器根据分组的标志将其放入不同的队列转发",{"key":27,"text":385,"correct":22},"在建立连接时根据优先级预留所需要的资源以提供所要求的QoS",{"key":31,"text":387,"correct":22},"根据IP分组中自带的优先级信息对IP分组进行排队，保证高优先的分组优先转发",{"id":389,"libraryId":5,"type":15,"typeLabel":16,"stem":390,"options":391,"answer":20,"analysis":33},386708,"网络的逻辑结构设计大致描述了设备的互联及分布，来自于用户需求中描述的网络行为、性能等要求，逻辑设计要根据网络用户的分类、分布，选择特定的技术，形成特定的网络结构。（ ）不属于网络的逻辑设计过程。",[392,394,396,398],{"key":20,"text":393,"correct":29},"确定设备物理位置",{"key":24,"text":395,"correct":22},"网络服务评价",{"key":27,"text":397,"correct":22},"技术选项评价",{"key":31,"text":399,"correct":22},"进行技术决策",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":20,"analysis":33},386709,"按照网络分级设计模型，通常把网络设计分为3层，即核心层、汇聚层和接入层。以下叙述中（ ）是不正确的。",[404,406,408,410],{"key":20,"text":405,"correct":29},"核心层实现访问控制列表检查功能",{"key":24,"text":407,"correct":22},"汇聚层实现网络的访问策略控制",{"key":27,"text":409,"correct":22},"工作组服务器，放置在接入层",{"key":31,"text":411,"correct":22},"在接入层可以用集线器代替交换机",{"id":413,"libraryId":5,"type":15,"typeLabel":16,"stem":414,"options":415,"answer":31,"analysis":33},386710,"在一个16000 m2建筑面积的八层楼里，没有任何现成网线，现有1200台计算机需要连网，对网络的响应速度要求较高，同时要求WLAN覆盖整栋楼满足临时连网的需要。设计师在进行物理网络设计时，提出了如下方案：设计一个中心机房，将所有的交换机、路由器、服务器放置在该中心机房，用UPS保证供电，用超5类双绞线电缆作为传输介质，在每层楼放置一个无线AP。该设计方案的致命问题之一是（）",[416,418,420,422],{"key":20,"text":417,"correct":22},"未计算UPS的负载",{"key":24,"text":419,"correct":22},"未明确线路的具体走向",{"key":27,"text":421,"correct":22},"交换机集中于机房浪费大量双绞线电缆",{"key":31,"text":423,"correct":29},"交换机集中于机房使得水平布线超过100米的长度限制",{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":20,"analysis":33},386711,"结构化布线系统分为六个子系统，由终端设备到信息插座的整个区域组成的是（ ）。",[428,430,432,434],{"key":20,"text":429,"correct":29},"工作区子系统",{"key":24,"text":431,"correct":22},"干线子系统",{"key":27,"text":433,"correct":22},"水平子系统",{"key":31,"text":435,"correct":22},"设备间子系统",{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":20,"analysis":33},386712,"关于网络资源命名的说法正确的是（ ）。",[440,442,444,446],{"key":20,"text":441,"correct":29},"交换机可以使用sw作为开头",{"key":24,"text":443,"correct":22},"名字不能包含位置代码",{"key":27,"text":445,"correct":22},"名字可以使用大小写来标记更多的资源",{"key":31,"text":447,"correct":22},"名字中可以使用连字符、下划线、空格等字符",{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":31,"analysis":33},386713,"工程师利用测试设备对某信息点己经连接好的网线进行测试时，发现有4根线不通，但计算机仍然能利用该网线连接上网。则不通的4根线是（ ）。",[452,454,456,458],{"key":20,"text":453,"correct":22},"1-2-3-4",{"key":24,"text":455,"correct":22},"5-6-7-8",{"key":27,"text":457,"correct":22},"1-2-3-6",{"key":31,"text":459,"correct":29},"4-5-7-8",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":20,"analysis":33},386714,"网络需求分析包括网络总体需求分析、综合布线需求分析、网络可用性和可靠性分析、网络安全需求分析，此外还需要进行 （ ） 。",[464,466,468,470],{"key":20,"text":465,"correct":29},"工程造价估算",{"key":24,"text":467,"correct":22},"工程进度安排",{"key":27,"text":469,"correct":22},"硬件设备选型",{"key":31,"text":471,"correct":22},"IP地址分配分析",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":20,"analysis":33},386715,"网络系统设计过程中，物理网络设计阶段的任务是（ ）",[476,478,480,482],{"key":20,"text":477,"correct":29},"依据逻辑网络设计的要求，确定设备的具体物理分布和运行环境",{"key":24,"text":479,"correct":22},"分析现有网络和新网络的各类资源分布，掌握网络所处的状态",{"key":27,"text":481,"correct":22},"根据需求规范和通信规范，实施资源分配和安全规划",{"key":31,"text":483,"correct":22},"理解网络应该具有的功能和性能，最终设计出符合用户需求的网络",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":31,"analysis":33},386716,"以下关于QoS说法不正确的是（ ）。",[488,490,492,494],{"key":20,"text":489,"correct":22},"对QoS进行分类和定义的目的是使网络可以根据不同类型的QoS进行管理和分配资源。",{"key":24,"text":491,"correct":22},"QoS可进行准入控制和协商",{"key":27,"text":493,"correct":22},"为了给用户提供满意的QoS，必须对端系统、路由器以及传输带宽等相应的资源进行预约，以确保这些资源不被其他应用所抢用。",{"key":31,"text":495,"correct":29},"为了快速释放资源，当资源进行预约以后，各类系统无需调度直接使用资源。",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":31,"analysis":33},386717,"工程师利用某种测试设备在每个信息点对已经连接好的网线进行测试时，发现每个UTP中都有几根线的长度不正确，以为是RJ45接头做得不好，于是重做RJ45接头，但现象依旧。经检查，测试设备无故障。更好的测试方案是（） 。",[500,502,504,506],{"key":20,"text":501,"correct":22},"选用更高级的测试设备",{"key":24,"text":503,"correct":22},"更换测试人员",{"key":27,"text":505,"correct":22},"每个信息点连接计算机看是否能上网",{"key":31,"text":507,"correct":29},"用户端不接计算机，在配线间反向测试",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":24,"analysis":33},386718,"网络设计过程包括逻辑网络设计和物理网络设计两个阶段，各个阶段都要产生相应的文档，以下选项中，（ ）属于物理网络设计文档。",[512,514,516,518],{"key":20,"text":513,"correct":22},"网络IP地址分配方案",{"key":24,"text":515,"correct":29},"设备列表清单",{"key":27,"text":517,"correct":22},"集中访谈的信息资料",{"key":31,"text":519,"correct":22},"网络内部的通信流量分布",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":20,"analysis":33},386719,"评估网络性能时，用户最关心的指标是（） 。",[524,526,528,530],{"key":20,"text":525,"correct":29},"实际数据率",{"key":24,"text":527,"correct":22},"丢包率",{"key":27,"text":529,"correct":22},"性价比",{"key":31,"text":531,"correct":22},"故障率",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":20,"analysis":33},386720,"下列叙述中，（ ）不属于综合布线系统的设计原则。",[536,538,540,542],{"key":20,"text":537,"correct":29},"综合布线系统与建筑物整体规划、设计和建设各自进行",{"key":24,"text":539,"correct":22},"综合考虑用户需求、建筑物功能、经济发展水平等因素",{"key":27,"text":541,"correct":22},"长远规划思想、保持一定的先进性",{"key":31,"text":543,"correct":22},"采用扩展性、标准化、灵活的管理方式",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":31,"analysis":33},386721,"结构化综合布线系统中的干线子系统是指（ ）。",[548,550,552,554],{"key":20,"text":549,"correct":22},"管理楼层内各种设备的子系统",{"key":24,"text":551,"correct":22},"连接各个建筑物的子系统",{"key":27,"text":553,"correct":22},"工作区信息插座之间的线缆子系统",{"key":31,"text":555,"correct":29},"实现楼层设备间连接的子系统",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":20,"analysis":33},386722,"三层网络模型是最常见的分层化网络设计模型，将数据分组从一个区域高速地转发到另一个区域属于（ ）的功能",[560,562,564,566],{"key":20,"text":561,"correct":29},"核心层",{"key":24,"text":563,"correct":22},"汇聚层",{"key":27,"text":565,"correct":22},"中间层",{"key":31,"text":567,"correct":22},"接入层",{"id":569,"libraryId":5,"type":15,"typeLabel":16,"stem":570,"options":571,"answer":31,"analysis":33},386723,"甲公司承接了乙公司的网络建设工作。由于待建网络规模很大，为确保建设工作顺利进行，负责该项目的工程师在进行逻辑设计时提出了如下工作思路： ①明确逻辑设计工作的内容是：网络拓扑结构设计；物理层技术选择；局域网技术选择；广域网技术选择；地址设计；路由协议选择；网络管理模式与工具选择；撰写逻辑设计文档。 ②在进行地址设计时，确定的方案是：按乙公司各分支机构的地理位置划分地址块，并按10.n.X .Y \u002F16的模式分配，其中n为分支机构的序号（0表示公司总部，分支机构总数不会超过200）。 对该工程师确定的逻辑设计内容的评价，恰当的是（）。",[572,574,576,578],{"key":20,"text":573,"correct":22},"内容全面，符合逻辑设计的工作准则",{"key":24,"text":575,"correct":22},"应去掉物理层技术选择这一部分",{"key":27,"text":577,"correct":22},"应去掉路由协议选择这一部分",{"key":31,"text":579,"correct":29},"应增加网络安全设计这一部分",{"id":581,"libraryId":5,"type":15,"typeLabel":16,"stem":582,"options":583,"answer":24,"analysis":33},386724,"DHCP客户端启动时会向网络发出一个Dhcpdiscover包来请求IP地址，其源IP地址为 （请作答此空） ；目标地址为（ ）。",[584,586,588,589],{"key":20,"text":585,"correct":22},"192.168.0.1",{"key":24,"text":587,"correct":29},"0.0.0.0",{"key":27,"text":349,"correct":22},{"key":31,"text":590,"correct":22},"255.255.255.255",{"id":592,"libraryId":5,"type":15,"typeLabel":16,"stem":593,"options":594,"answer":20,"analysis":33},386725,"点对点协议PPP中LCP的功能是( )。",[595,597,599,601],{"key":20,"text":596,"correct":29},"建立、释放和测试数据链路",{"key":24,"text":598,"correct":22},"网络控制协议",{"key":27,"text":600,"correct":22},"协商网络层参数",{"key":31,"text":602,"correct":22},"身份认证协议",{"id":604,"libraryId":5,"type":15,"typeLabel":16,"stem":605,"options":606,"answer":31,"analysis":33},386726,"在一个占地200*80m2生产大型机床的车间里布置网络，有200台计算机需要连网，没有任何现成网线，对网络的响应速度要求是能实时控制。设计师在进行物理网络设计时，提出了如下方案：设计一个中心机房，将所有的交换机、路由器、服务器放置在该中心机房，用UPS保证供电，用超5类双绞线电缆作为传输介质并用PVC 线槽铺设。该设计方案的最严重问题是（） 。",[607,609,611,612],{"key":20,"text":608,"correct":22},"未将机房与厂房分开",{"key":24,"text":610,"correct":22},"未给出机房的设计方案",{"key":27,"text":421,"correct":22},{"key":31,"text":613,"correct":29},"交换机集中于中心机房将使得水平布线超过100米的长度限制",[615,619,622,625,628,631],{"id":616,"name":617,"category":7,"favorite":618},136,"法律职业试卷二(客观题 )",2,{"id":620,"name":621,"category":7,"favorite":15},137,"法律职业试卷一(客观题 )",{"id":623,"name":624,"category":7,"favorite":15},176,"（初级）社会工作实务",{"id":626,"name":627,"category":7,"favorite":15},177,"（初级）社会综合能力",{"id":629,"name":630,"category":7,"favorite":8},28,"安全工程师",{"id":632,"name":633,"category":7,"favorite":8},112,"安全生产法律知识"]